Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “local oscillator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

EHF low-noise FET receiver

Extremely high frequency (EHF) receivers for military and NASA programs must be small, lightweight, and highly reliable. In connection with recent advances in the development of mm-wave FET devices and circuits, a basis has been obtained for the eventual replacement of diode mixer front-ends by FET preamplifiers in receivers up to 94 GHz. By placing a low noise amplifier in front of the mixer it is possible to achieve a lower system noise figure than that found in conventional mm-wave receivers. A broader bandwidth can also be provided. Attention is given to the receiver configuration, a low noise FET amplifier, an image rejection filter, a dual-gate FET mixer, a FET local oscillator, and a FET receiver.

Schellenberg, J. M.↗

Recovering Microwave Cross-Polarization Losses

Reception improved by adding normally discarded portion of signal. For signal enhancement, major and minor signals combined in slaved closedloop receiver channels. Both receiver channels served by common local oscillator controlled by phase-locked loop in main channel. 10-MHz intermediate-frequency (IF) signals of channels coherently summed. For polarization tracking, phasemeter added to measure phase difference between points A and B. With new circuit, low-level signal used at receiver to augment main signal.

Seidel, B. L.↗

Generating Tunable Far-Infrared Laser Sidebands

New tunable source extends infrared spectroscopy into far infrared wavelengths. Frequency-Tunable far-infrared radiation produced by mixing of fixed-frequency far-infrared laser beam with output of frequency-tunable klystron. By sweeping klystron frequency in synchronism with video display of detector output, one obtains direct presentation of absorption-cell spectrum. Immediate applications are local oscillator for heterodyne systems and tunable source for spectroscopy.

Pickett, H. M.↗

A 150 Micron Heterodyne Spectrometer for Airborne Astronomy

The advantages of heterodyne detection for high resolution spectroscopy were long known to radio astronomers. Heterodyne spectroscopy was productive at submillimeter wavelengths, but its extension to shorter submillimeter and far-infrared (FIR) wavelengths was hampered by inadequate mixers and local oscillators. A significant advance in FIR receiver technology was demonstrated using an optically-pumped FIR laser and a Schottky-diode mixer. Any similar spectrometer intended for airborne observations at shorter wavelengths must be compatible with the more restrictive aircraft environment. The effectiveness of the design of a FIR heterodyne spectrometer was verified in ground-based observations with a prototype version. The airborne successor is even more compact, and has a much broader spectral coverage. Flight tests are scheduled for the new instrument.

Betz, A.↗

Tunable Heterodyne Receiver from 100 Micron to 1,000 Micron for Airborne Observations

Interest in high resolution spectrometers for the submillimeter wavelength range from 100 micron to 1,000 micron is mostly stimulated by molecular spectroscopy in radioastronomy and atmospheric physics, and by plasma diagnostic experiments. Schottky diodes in waveguide mixer technology and InSb-hot electron bolometers are successfully used in the 0.5 to a few millimeter range whereas tandem Fabry-Perot spectrometers combined with photoconductive detectors (Ge:Sb and Ge:Ga) are used for the 100 micron range. Recent research on heterodyne spectrometers, with Schottky diodes in an open structure mixer and a molecular laser as local oscillators, which can be used over the whole wavelength range is summarized.

Roeser, H. P.↗

An infrared search for extraterrestrial laser signals

The focus of project SETI is on microwave frequencies, where receivers fundamentally have the best sensitivity for the detection of narrow band signals. Such receivers, when coupled to existing radio telescopes, form an optimum system for broad area searches over the sky. Detection of narrow band infrared signals is best done with a laser heterodyne reciever similar in function to a microwave spectral line receiver. A receiver was built for astrophysical observations at 30 THz (10 microns) and the spectrometer is being adapted for SETI work. The receiver uses a small CO2 laser as the local oscillator, a HgCdTe diode as the photomixer, and a multichannel intermediate frequency (IF) filterbank. An advanced multichannel IF processor is now being built to detect infrared line radiation in 1000 spectral channels each 1 MHz wide. When completed this processor will be used with a ground based telescope next year for a survey of several hundred selected stars for narrow band CO2 laser signals at 30 THz.

Betz, A.↗

A general numerical analysis program for the superconducting quasiparticle mixer

A user-oriented computer program SISCAP (SIS Computer Analysis Program) for analyzing SIS mixers is described. The program allows arbitrary impedance terminations to be specified at all LO harmonics and sideband frequencies. It is therefore able to treat a much more general class of SIS mixers than the widely used three-frequency analysis, for which the harmonics are assumed to be short-circuited. An additional program, GETCHI, provides the necessary input data to program SISCAP. The SISCAP program performs a nonlinear analysis to determine the SIS junction voltage waveform produced by the local oscillator. The quantum theory of mixing is used in its most general form, treating the large signal properties of the mixer in the time domain. A small signal linear analysis is then used to find the conversion loss and port impedances. The noise analysis includes thermal noise from the termination resistances and shot noise from the periodic LO current. Quantum noise is not considered. Many aspects of the program have been adequately verified and found accurate.

Hicks, R. G.↗

Imaging front-end systems for millimeter waves and submillimeter waves

Imaging (multi-beam) front-end systems utilize a reflector or a lens, as well as a focal-plane array of receptor elements (beams). To be practical, such systems must utilize focal plane arrays which can be fabricated using hybrid integrated (and eventually monolithic) technology. This paper reviews alternative approaches to focussing elements, auxiliary devices required for local oscillator injection and similar functions, and focal plane arrays. It also discusses general limitations and advantages of these approaches, as well as typical applications to millimeter and submillimeter astronomical instrumentation.

Yngvesson, K. S.↗

Far-infrared heterodyne spectroscopy

A new far-infrared heterodyne spectrometer has been built for ground-based observations at the Cassegrain focus. The receiver, which features a Schottky-diode mixer and a laser local oscillator, was used in January 1984, to detect the 809 GHz fine-structure line of neutral carbon in OMCl. A second-generation version of the spectrometer is now being constructed for airborne observations between 600 and 1500 GHz.

Betz, A. L.↗

Design and optimization of NbCN/PbBi mixer elements for heterodyne receivers

Superconductor-Insulator-Superconductor (SIS) quantum mixers provide a relatively new approach to millimeter wave mixing potentially offering conversion gain, a low local oscillator power demand and potential mixer temperatures near the quantum limit. This paper presents device modeling and fabrication development for NbCN lead-alloy submicron edge-contact SIS mixers for use at 115 GHz.

Lichtenberger, A. W.↗

Laser heterodyne system for obtaining height profiles of minor species in the atmosphere

An infrared laser heterodyne system for obtaining height profiles of minor constituents of the atmosphere was developed and erected. A brief discription of the system is given. The system consists of a tunable CO2 waveguide laser in the 9 to 11 micrometer band, that is used as a local oscillator and a heliostat that follows the sun and brings in solar radiation, that is mixed with the laser beam in a high speed liquid nitrogen cooled mercury cadmium telluride detector. The detected signal is analysed in a RF spectrum analyser that allows tracing absorption line profiles. Absorption lines of a number of minor constituents in the troposphere and stratosphere, such as O3, NH3, H2O, SO2, ClO, N2O, are in the 9 to 11 micrometer band and overlap with that of CO2 laser range. The experimental system has been made operational and trial observations taken. Current measurements are limited to ozone height profiles. Results are presented.

Jain, S. L.↗

Advanced infrared astronomy

The CO2 laser heterodyne spectrometer was used at the 3-m IRTF on Mauna Kea to make measurements of Mars during the 1984 opposition. Analysis of the observations of the mesospheric non-thermal emission demonstrated the existence of a warming of the Mars polar mesosphere, similar to the seasonal effects which are well known to occur at the Earth's mesopause. A search for CO2 and NH3 on Comet Halley was done with the new Kitt Peak system as well as with the IRTF heterodyne system. A Lamb-dip absorption cell was designed and constructed. Its use will allow extreme frequency stabilization of the laser local oscillator, which will greatly facilitate measurements of winds and dynamical phenomena. The Lamb-dip cell was used at Kitt Peak to study zonal and meridional winds in the atmosphere of Venus. Water vapor was detected in Comet Halley using Fourier transform spectrometer. The 2.65 micrometer upsilon sub 3 band was seen in emission, confirming non-thermal-equilibrium excitation models for comets. A study was made of the variability of Jovian ethane emission. The average volume mixing ratio of ethane in the Jovian stratosphere was found to be 3x10 to the -6 power, with the greatest variability seen in the auroral regions.

Mumma, M. J.↗

Instrumentation for submillimeter spectroscopy; Proceedings of the Meeting, Cannes, France, December 5, 6, 1985

The design and performance of spectroscopic instruments for submm-wave astronomy are discussed in reviews and reports. Topics examined include superconducting mixers, Schottky-diode mixers, local oscillators, antennas and quasi-optical components, spectrometry, and systems aspects. Special emphasis is given to candidate components for the 8-m heterodyne FIR and Submm Space Telescope being developed by ESA.

Kollberg, Eric↗

Optimization of SIS mixer elements

Superconductor-Insulator-Superconductor (SIS) quantum mixers provide an approach to millimeter wave mixing - potentially offering conversion gain, a low local oscillator power demand, and potential mixer noise temperatures near the quantum limit. The development of a reliable fabrication technology for producing such high quality SIS devices for mixer applications in radio astronomy is the focus of the work.

Mattauch, Robert J.↗

Optimized tracking of RF carriers with phase noise, including Pioneer 10 results

The ability to track very weak signals from distant spacecraft is limited by the phase instabilities of the received signal and of the local oscillator employed by the receiver. These instabilities ultimately limit the minimum loop bandwidth that can be used in a phase-coherent receiver, and hence limit the ratio of received carrier power to noise spectral density which can be tracked phase coherently. A method is presented for near real time estimation of the received carrier phase and additive noise spectrum, and optimization of the phase locked loop bandwidth. The method was used with the breadboard Deep Space Network (DSN) Advanced Receiver to optimize tracking of very weak signals from the Pioneer 10 spacecraft, which is now more distant that the edge of the solar system. Tracking with bandwidths of 0.1 Hz to 1.0 Hz reduces tracking signal threshold and increases carrier loop signal to noise ratio (SNR) by 5 dB to 15 dB compared to the 3 Hz bandwidth of the receivers now used operationally in the DSN. This will enable the DSN to track Pioneer 10 until its power sources fails near the end of the century.

Vilnrotter, V. A.↗

Optically pumped submillimeter gas lasers and the prospects for constructing space-qualifiable LO systems

An optically pumped, submillimeter laser operating in the 500 micron (600 GHz) to 100 micron (3 THz) spectral range is the primary and, at present, the only available local oscillator (LO) source for laboratory and astronomical heterodyne applications for this wavelength region. A short review of the state-of-the-art of submillimeter lasers as LO sources, with an emphasis given to receiver systems designed for airborne heterodyne observations, is presented. The characteristics and prospects for constructing a space-qualifiable laser LO system will also be given.

Chin, Gordon↗

30-micron heterodyne receiver

Advantages and constraints of remote measurements using heterodyne spectroscopy near 30 microns are discussed. The state of the art of wideband HgCdTe photomixers and PbSnSe diode-laser local oscillators being developed for FIR heterodyne receivers is described. The first compact 30-micron heterodyne radiometer was built, and initial results at 28-microns show about 2-percent mixer efficiency for a 500-MHz-bandwidth receiver. Factors limiting receiver performance are discussed, along with the projected sensitivity of new interdigitated-electrode HgCdTe photoconductor mixers being developed for operation up to 200 microns.

Kostiuk, Theodor↗

The UCB/MPE Cassegrain Submillimeter Heterodyne Spectrometer

The UCB/MPE Submillimeter Heterodyne Spectrometer is a system for astronomical spectroscopy in the high-frequency atmospheric windows from 500 to 1000 GHz. It contains a molecular laser local oscillator, a cooled Schottky open structure mixer, a quasi-optical coupling system, and an acoustooptical spectrometer. The compact receiver mounts at the Cassegrain focus of large infrared astronomical telescopes. The receiver noise temperature on the telescope is approximately 3500 K (DSB) during observations of the CO J = 7-6 line at 806.652 GHz. The spectrometer's frequency resolution and instantaneous bandwidth (less than 2 MHz resolution across 1.1 GHz) are well suited for observations of molecular emission lines from a variety of astronomical sources.

Harris, A. I.↗