Commercial and Residential Hourly Load Profiles for All Typical Meteorological Year 3 (TMY3) Locations in the United States

One way to achieve grid flexibility is to shed or shift demand to align with changing grid needs. To facilitate this, it is critical to understand how and when energy is used. High-quality end-use load profiles (EULPs) provide this information and can help cities, states, and utilities understand the time-sensitive value of energy efficiency, demand response, and distributed energy resources. Publicly available EULPs have traditionally had limited application because of age and incomplete geographic representation. To help fill this gap, the U.S. Department of Energy funded a 3-year project, End-Use Load Profiles for the U.S. Building Stock, that culminated in this publicly available dataset of calibrated and validated 15-minute-resolution load profiles for all major residential and commercial building types and end uses across all climate regions in the United States. These EULPs were created by calibrating the ResStock and ComStock physics-based building stock models using many different measured datasets, as described in the "Technical Report Documenting Methodology" linked in the submission.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

EV Hosting Capacity Analysis on Distribution Grids

The increasing trend in electric vehicle (EV) adoption can cause challenges to traditional electric grid operations if utilities are not equipped with tools and methods to effectively manage these fleets. Growing EV charging loads will alter the magnitude and duration of conventional peaks in demand profiles and even significantly shift them, potentially causing operational violations in the distribution grid. This paper presents the development and results of an EV hosting capacity tool to quantify the impacts of injecting large numbers of EV charging loads and to determine the available capacity of existing distribution feeders to continue providing reliable and affordable grid operations. Tools like the hosting capacity analysis would enable utilities to better prepare for grid operations in the near future while exploring the impact and effectiveness of strategies to manage these loads, such as peak pricing and smart charging. This paper evaluates the hosting capacity of some real-world feeders to accommodate EV charging loads, including extreme fast-charging options.

distribution grid↗

Design trade-offs for residential retail tariffs and virtual power plants

Retail rate design and virtual power plants (VPPs) have the potential to shift customer electricity demand and provide economic benefits to utility customers. As the adoption of distributed energy resources (DERs) and flexible loads increases, retail tariff and program design can impact Bonbright's rate design principles including affordability, fairness, and economic efficiency. We model the effects of residential retail rates and VPP programs on power system costs in Massachusetts under a potential future system with high renewable energy and DER adoption. We model interactions among retail rate design, demand flexibility, and utility costs and identify trade-offs across different rate designs and VPP programs. We estimate that time-of-use (TOU) rates and VPP programs designed to avoid critical peak rates can lower overall system costs by 3.5 %-4.8 %. These lower costs translate to lower electricity bills for 62 %-91 % of customers, depending on the scenario. Although TOU rates with a critical peak VPP program can benefit all customer segments and are economically efficient, a VPP program with flat rates leads to the lowest overall bills for customers. We find that customers with loads that align with peak demand and who participate in critical peak VPP programs can underpay for their contribution to utility costs and shift costs to other customers. While our assumptions about mandatory TOU and/or critical peak pricing likely impact the magnitude of the results, the results highlight the trade-offs of these tariffs and programs and the importance of tariff and program design as demand becomes more flexible and responsive.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A review of active probing-based system identification techniques with applications in power systems

System identification is becoming a relevant research area for numerous applications in power grids due to the increasing complexity of the system. A paradigm shift in power system infrastructure driven by renewable energy resources, controllable loads, and new power electronics technologies have given rise to new challenges in power systems operation and control. This increased complexity of power systems and unavailability of physics-based models of most inverter-based resources requires that traditional modeling of power systems approaches be complemented by system identification-based black or grey box modeling techniques. In light of the importance of system identification and little attention paid to the applications of these techniques in transforming power systems, this paper provides a comprehensive review of active probing-based system identification methods in the context of power system applications. It reviews applications of both linear and nonlinear system identification with discussion on their potential and key takeaways. To motivate a further practical use in power systems, the paper provides an example of system identification, to develop a state space model of an unknown plant with step-by-step details. The paper highlights the advantages of using modern power electronics-based sources in the identification process and discusses the emerging research directions for future.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Catalyzing deep decarbonization with federated battery diagnosis and prognosis for better data management in energy storage systems

Industrial data analytics methods play a central role in improving energy storage performance and efficiency, impacting the future of electrified transportation and renewable electricity generation. However, significant challenges hinder the large-scale deployment of batteries. Conventional methods rely on centralized collection and processing of fleet-level data, leading to database size issues and privacy concerns due to potential data breaches. To enable scalable deployment of battery management systems, this article proposes a federated battery diagnosis and prognosis model, which distributes the processing of battery standard current-voltage-time-usage data in a privacy-preserving manner. Instead of transferring the raw data, this approach communicates only the locally processed parameters, thus reducing communication load and preserving data confidentiality. The federated model offers a paradigm shift in battery health management through privacy-preserving distributed methods for battery data processing and lifetime prediction, ensuring the reliable and sustainable deployment of lithium-ion batteries in a rapidly evolving world.

asset health management↗

Mica filled polyetherketoneketones for material extrusion 3D printing

Polyetherketoneketone (PEKK) has superior physical properties to most available thermoplastics compatible with material extrusion-based 3D printing, including analogs in the polyaryletherketone (PAEK) family. To date, the performance of fused filament fabrication (FFF) compatible PEKK has been detailed primarily as a function of varying the isomer ratios composing the co-polymer structure. The strategy to form blends or composites with PEKK for FFF is attractive for further tailoring of performance in application, yet has received limited attention. Here, we report the integration of three grades of mica platelets into PEKK at 10% and 30% mass loadings to generate an array of filament feedstocks that were then used to print objects with a simple FFF machine. The effects of mica coating chemistry and surface treatment on the compatibility with PEKK and resulting properties are described. Mica fillers at both loadings have only subtle influence on the FFF relevant melt rheological properties inherent to PEKK. Pigment micas at high loadings can lower the melting temperature of PEKK (up to 19 ºC) without shifting its glass transition temperature and inhibit much of the undesirable crystallization occurring during processing with unfilled PEKK. The printed composites were effectively cold crystallized post-printing, affording crystalline fractions up to 90% relative to unfilled PEKK with increased dimensional stabilities. All micas, when used as fillers in low and high relative PEKK crystallinities, significantly increased the tensile modulus (as high as 126% or to 7.31 GPa) of parts in correlation to the loading. Furthermore, the underlying microstructural features of a printed composite were compared to unfilled PEKK by use of a high-resolution helical micro-computed tomography instrument. Practically, pigment micas can confer a wide range of rich colors to 3D-printed PEKK.

36 MATERIALS SCIENCE↗

The ever-evolving active site: transformation of single atoms to extended structures during the Rh-catalyzed reverse water–gas shift reaction

At low temperatures (< 400°C), single atoms of Rh supported on rutile TiO 2 (rTiO 2 ) are responsible for the formation of CO during the reverse water gas shift (RWGS), while methane production is associated with the Rh-TiO 2 interface due to the correlation between methane formation rates and the volume-averaged Rh nanoparticle diameter. As the temperature is increased to >540°C, there is a notable increase in CO selectivity and methane production rates tend towards zero. The time to reach zero depends on the temperature but independent of the initial Rh structure (single atoms and/or nanoparticles), which is controlled by the catalyst preparation method (wetness impregnation versus colloidal nanoparticles). At 600°C and > 4 h time on stream, the catalytic behaviour becomes completely agnostic to the initial Rh structure as well as weight loading, and the catalysts are highly selective for the reverse water gas-shift reaction. Post-reaction HR-TEM image analysis confirms Rh nanoparticles crystallize/order during the reaction; at 400°C, most of the Rh particles are disordered, while at 600°C, they are more ordered (i.e., development of defined faceting). Infrared spectroscopy of CO adsorption on Rh nanoparticles confirms the appearance of defined facets after annealing in nitrogen at high temperatures. Annealing the Rh/rTiO 2 catalysts prior to the RWGS reaction demonstrates the structural transformation of Rh depends only on time and temperature and not on reactant or product fugacity. Sites responsible for stabilizing Rh single atoms are no longer competent at higher temperatures, enabling their integration into existent nanoparticles. As the reaction temperature is increased to temperatures >540°C, the dominant active site for CO production evolves from single atoms to extended Rh structures.

36 MATERIALS SCIENCE↗

Electrification Futures Study Flexible Load Profiles

This data set includes hourly profiles for flexible load developed for the Electrification Futures Study (EFS). The load profiles represent projected end-use electricity demand that is assumed to be flexible (i.e., can be shifted throughout a day) for various scenarios of flexibility (Base, Enhanced), electrification (Reference, Medium, High), and technology advancement (Slow, Moderate, Rapid), and were developed as inputs into the ReEDS model. The quantity of flexible load is estimated using assumptions on the level of flexibility and customer participation within each subsector modeled in the EFS. Detailed assumptions and modeling implementation will be documented in ongoing EFS analyses. Flexible load profiles are provided for a subset of years (2018, 2020, 2024, 2030, 2040, 2050) and are aggregated to the state and sector level. Total electricity load profiles can be found in a related EFS data set (https://dx.doi.org/10.7799/1593122). NOTE: Due to the file size, Mac users may experience issues decompressing the zip files using the Mac Archive Utility. In those cases, decompressing using the command line is recommended. - Mai, Trieu, Paige Jadun, Jeffrey Logan, Colin McMillan, Matteo Muratori, Daniel Steinberg, Laura Vimmerstedt, Ryan Jones, Benjamin Haley, and Brent Nelson. 2018. Electrification Futures Study: Scenarios of Electric Technology Adoption and Power Consumption for the United States. National Renewable Energy Laboratory. NREL/TP-6A20-71500. https://doi.org/10.2172/1459351. - Murphy, Caitlin, Trieu Mai, Yinong Sun, Paige Jadun, Matteo Muratori, Brent Nelson, Ryan Jones. Forthcoming. Electrification Futures Study: Scenarios of Power System Evolution and Infrastructure Development for the United States. National Renewable Energy Laboratory. - Sun, Yinong, Paige Jadun, Brent Nelson, Matteo Muratori, Caitlin Murphy, Jeffrey Logan, and Trieu Mai. Forthcoming. Electrification Futures Study: Methodological Approaches for Assessing Long-Term Power System Impacts of End-Use Electrification. National Renewable Energy Laboratory.

buildings↗

Value of Geothermal Energy Storage for Supply-Side and Demand-Side Applications

This report presents the results of a study examining the value potential for geothermal energy storage (GES), a long-duration energy storage resource that stores thermal and/or geomechanical energy in the subsurface. GES could benefit the overall U.S. power system by temporally shifting electricity generation (supply-side) or meeting building heating and cooling load (demand-side). This report analyzes supply-side and demand-side opportunities independently because of differences in applications and models. Currently there is significant uncertainty about the development costs for GES, with only a limited number of demonstration plants for electric energy storage and building heating and cooling storage developments. In this report, we estimate the value of supply-side and demand-side GES to the bulk power system in the contiguous United States. Because of the significant uncertainty about GES development costs, this analysis does not consider GES deployment costs but instead focuses on the value of GES to the U.S. electricity system. The estimated values of GES provide reference points for economically competitive commercial cost targets. Supply-side GES is modeled as part of an enhanced geothermal system (EGS) generation plant in NREL's Regional Energy Deployment System (ReEDS) capacity expansion model (Ho et al. 2021). In contrast to conventional geothermal plants, which generate constant power, EGS plants have unique features that may allow for in-reservoir energy storage for flexible generation. Demand-side GES for heating and cooling, including seasonal hot and cold storage and short-duration heat pump storage, is incorporated into a price-taker model using Cambium electricity marginal cost projections. To establish an upper bound for the value of GES, analysis focused on favorable scenarios for storage with high generation from zero marginal cost, variable renewable energy resources. High penetrations of variable renewable energy generation can increase hourly electricity price variability, which increases the value of temporal energy arbitrage for storage technologies like GES.

15 GEOTHERMAL ENERGY↗

Impacts of COVID-19 related stay-at-home restrictions on residential electricity use and implications for future grid stability

“Stay-at-home” orders and other health precautions enacted during the COVID-19 pandemic have led to substantial changes in residential electricity usage. Here, we conduct a case study to analyze data from 390 apartments in New York City (NYC) to examine the impacts of two key drivers of residential electricity usage: COVID-19 case-loads and the outdoor temperature. We develop a series of regression models to predict two characteristics of residential electricity usage on weekdays: The average occupied apartment’s consumption (kWh) over a 9am-5pm window and the hourly peak demand (Watt) over a 12pm-5pm window. Via a Monte Carlo simulation, we forecast the two usage characteristics under a possible scenario in which stay-at-home orders in NYC, or a similar metropolitan region, coincide with warm summer weather. Under the scenario, the 9am-5pm residential electricity usage on weekdays is predicted to be 15% – 24% higher than under prior, pre-pandemic conditions. This could lead to substantially higher utility costs for residents. Additionally, we predict that the residential hourly peak demand between 12pm and 5pm on weekdays could be 35% – 53% higher than that under pre-pandemic conditions. We conclude that the projected increase in peak demand - which might arise if stay-at-home guidelines coincided with hot weather conditions - could pose grid management challenges, especially for residential feeders. We also note that, if there is a longer lasting shift towards work and study-from-home, utilities will have to rethink load profile considerations. The applications of our predictive models to managing future smart-grid technology are also highlighted.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimal Storage Response to Utility Tariff Structures and Potential Use of Capacity Charges

Energy storage is increasingly being deployed in behind-the-meter use cases, partially in response to falling lithium-ion prices and new utility tariff structures. Utilities are grappling with new tariff design in the presence of distributed energy resources (DER), trying to motivate, fairly price the contribution of, and, in some cases, discourage, certain operation of DER. There are opportunities for energy storage under emerging tariff structures, but utility net load management objectives for storage remain unclear. Diverse tariff structures motivate the use of energy storage to provide one or a combination of: energy arbitrage, energy shifting, solar self-consumption, and import shaving. This paper formulates a linear optimization to demonstrate the optimal storage tariff response, examining customer net load metrics under diverse utility tariff structures, such as time-of-use, net metering, feed-in tariffs, zero export tariffs, and demand charges. A key contribution of this paper is the introduction and examination of a capacity charge as mechanism that can both motivate reductions in both peak import, and exports, along with greater load levelling.

behind-the-meter↗

Harnessing peptide–cellulose interactions to tailor the performance of self-assembled, injectable hydrogels

Taking inspiration from natural systems, such as spider silk and mollusk nacre, that employ hierarchical assembly to attain robust material performance, we leveraged matrix–filler interactions within reinforced polymer–peptide hybrids to create self-assembled hydrogels with enhanced properties. Specifically, cellulose nanocrystals (CNCs) were incorporated into peptide–polyurea (PPU) hybrid matrices to tailor key hydrogel features through matrix–filler interactions. Herein, we examined the impact of peptide repeat length and CNC loading on hydrogelation, morphology, mechanics, and thermal behavior of PPU/CNC composite hydrogels. The addition of CNCs into PPU hydrogels resulted in increased gel stiffness; however, the extent of reinforcement of the nanocomposite gels upon nanofiller inclusion also was driven by PPU architecture. Temperature-promoted stiffening transitions observed in nanocomposite PPU hydrogels were dictated by peptide segment length. Analysis of the peptide secondary structure confirmed shifts in the conformation of peptidic domains (α-helices or β-sheets) upon CNC loading. Finally, PPU/CNC hydrogels were probed for their injectability characteristics, demonstrating that nanofiller–matrix interactions were shown to aid rapid network reformation (∼10 s) upon cessation of high shear forces. Overall, this research showcases the potential of modulating matrix–filler interactions within PPU/CNC hydrogels through strategic system design, enabling the tuning of functional hydrogel characteristics for diverse applications.

42 ENGINEERING↗

Catalyst-Specific Accelerated Stress Tests in Proton Exchange Membrane Low-Temperature Electrolysis for Intermittent Operation

Device-level stress tests are developed that focus on anode catalyst layer degradation and future anticipated operating conditions, including intermittent load and reduced platinum group metal content. Square-wave cycles with an upper load limit of 2.5 A cm -2 are utilized to screen commercial iridium (Ir) materials. Performance losses are primarily due to decreasing kinetics and are accompanied by catalyst migration into the membrane, worsening catalyst/ionomer integration, and weakening of the catalyst/membrane interface. For ruthenium-containing catalysts, the in situ performances are higher but durabilities lower than Ir baselines, and any performance advantage is lost within the test. Increased loss is likely due to the higher dissolution rate; microscopy confirmed greater degrees of ruthenium migration. For Ir metal or mixed oxides, ex situ activity improvements generally did not translate to in situ performance. The durability, however, is significantly lower and the loss rate increased from 3 (oxide) to 9 (metal) μ V cycle -1 . These results are consistent with historical findings in literature, rationalize the continued use of iridium oxide as a baseline catalyst, and demonstrate that traditional catalyst development approaches may not improve device-level durability when focused on low-cost applications. A shift in focus may therefore be more effective at improving catalyst utilization and lessening load requirements.

08 HYDROGEN↗

Study of the interplay between lower-order and higher-order energetic strain-gradient effects in polycrystal plasticity

in this report strain-gradient (SG) plasticity refers to a class of non-local theories in which gradients of plastic slip determine the storage of geometrically necessary dislocations, introducing a length-scale dependence in the mechanical behavior of crystalline materials, which is otherwise lacking in local theories. In this work, we incorporate lower-order (LO) and higher-order energetic (HOE) strain-gradient effects into a crystal plasticity fast Fourier transform (FFT)-based formulation to investigate the interplay of the length scale that each strain-gradient term introduces at the microscale, and the mechanical properties that result at the macroscale. For an applicable range of length scales, we consider two systems: a 1-D two-phase face centered cubic (FCC) laminate and a 3-D FCC polycrystal, and two uniaxial deformation modes: monotonic tension and cyclic tension–compression. We show that increases in the individual LO and HOE length scales increase the hardening rate and strength of the material, respectively. When combined, the strong LO hardening is less pronounced than the effect alone due to the lowering of the gradients due to the HOE microstress. We demonstrate that the LO and HOE hardening manifest as “isotropic” (yield surface expansion) and “kinematic” (yield surface shift) effects, respectively, consistent with their theoretical origins. We show that in cyclic loading, the Bauschinger effect emerges in both local and non-local calculations and link its origins and severity to the behavior in the strain field, slip-system rates, and the HOE microforce.

36 MATERIALS SCIENCE↗

Heavy-Duty Truck Electrification and the Impacts of Depot Charging on Electricity Distribution Systems

Major technological advancements and recent policy support are improving the outlook for heavy-duty truck electrification in the United States. In particular, short-haul operations (=200 miles (=322 km)) are prevalent and early candidates for plug-in electric vehicles (EVs) given their short, predictable routes and return-to-base applications, which allows vehicles to recharge when off shift at their depots. Although previous studies investigated the impacts of added electrical loads on distribution systems, which included light-duty EVs, the implications for heavy-duty EV charging are underexplored. Here we summarize the causes, costs and lead times of distribution system upgrades anticipated for depot charging. We also developed synthetic depot charging load profiles for heavy-duty trucks from real-world operating schedules, and found that charging requirements are met at common light-duty EV charging rates (=100 kW per vehicle). Finally, we applied depot charging load profiles to 36 distribution real-world substations, which showed that most can accommodate high levels of heavy-duty EV charging without upgrades.

47 OTHER INSTRUMENTATION↗

Subcritical Multiplication Ex-Core Calculations with Shift

This report details the development and testing of Virtual Environment for Reactor Applications (VERA) as applied to full core subcritical multiplication ex-core calculations with Shift. The limiting factor in being able to run these detector calculations with Monte Carlo is the amount of computational memory used by a fully-loaded full core problem. The main development features added to VERA in this effort were enabling source biasing and separable weight windows and integrating multithreading in Shift. With these capabilities, a subcritical multiplication detector response calculation on a full core Watts Bar Nuclear Plant Unit 1 (WBN1) ex-core model was successfully run on a moderately sized computing cluster.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Supporting ARPA-E Power Grid Optimization (Final Report)

Pacific Northwest National Laboratory (PNNL), Arizona State University (ASU), Georgia Institute of Technology (Georgia Tech), Los Alamos National Laboratory (LANL), National Renewable Energy Laboratory (NREL), Texas A&M University (TAMU), The University of Texas at Austin (UT), and the University of Wisconsin-Madison (UW-M) supported the ARPA-E Grid Optimization (GO) Competition by providing a common problem formulation, data format, datasets, evaluation mechanism, scoring, rules, and results that resulted in the awarding of $\$9.24$ million dollars to teams from academia, industry, and national labs for solving three sets of increasingly difficult non-linear, security- constrained AC Optimal Powerflow (AC-OPF) optimization problems in order to increase the efficiency of the US Electric Grid. It is estimated that a 1% increase in efficiency can save $\$1$ billion. Current industry practices typically use a linear DC model (DC-OPF) in order solve the OPF problem within the time constraints of the operation schedule. The GO Competition challenges the best power engineers, mathematicians, and computer scientists to make possible operational decisions based on accurate physical models. To accomplish this, the GO Competition created a series of Challenges and funded teams to produce the best solver. Challenge 1 was to solve the security constrained Alternating Current Optimal Power Flow (ACOPF) problem. Challenge 2 extended that to by adding adjustable transformer tap ratios, phase shifting transformers, switchable shunts, price-responsive demand, ramp rate constrained generators and loads, and fast-start unit commitment (UC). Furthermore, Challenge 2 was a maximization problem while Challenge 1 was a minimization problem. While Challenge 3 was being developed, the entrants were invited to find better solutions to the Challenge 2 synthetic datasets with no restrictions on time, hardware, or algorithms. The Challenge 2 solutions turned out to be very good. Challenge 3 expanded the Challenge 2 problem further by using multiperiod dynamic markets, including advisory models for extreme weather events, day-ahead markets, and the real-time markets with an extended look-ahead. These problems included active bid-in demand and topology optimization. Together the Challenges used nearly 30 million CPU hours. Since each team was working on the same problem, using the same data, and running on the same hardware, fair comparisons could be drawn as to the best solver. The datasets were varied enough, however, that the best solver for one dataset was not necessarily the best at another, so cumulative scores were used. The process was managed by the PNNL maintained website https://GOCompetition.energy.gov, where Entrants could find information about the problem, the data, the rules, submit their solver for evaluation, and see the scores of all the competing teams on a Leaderboard. Interest was world-wide but only American teams were eligible for prizes. The Competition has produced 34 journal articles 115 papers and been cited over 500 times in the literature, including 12 dissertations (4 from foreign countries; Columbia (2), Germany, and Italy) and 3 from the DOE ExaScale project. Software developed by Pearl Street Technologies for Challenges 1 and 2 is now deployed by Southwest Power Pool (SPP) and Midcontinent Independent Service Operator (MISO). Other teams have received inquiries from venture capitalists. Google DeepMind has thanked the Competition for making the datasets developed for the Competition public. They are using it to train machine learning models. The larger datasets have billions of unknowns to be solved for, but only a small percent matter in the final solution. Knowing what unknowns are important can dramatically speedup the solution.

24 POWER TRANSMISSION AND DISTRIBUTION↗