Measurements of the Van der Waals Na - lambda 5889 in He with a newly developed piston compressor light source
Measurements of Van der Waals Na 5889 A in He with piston compressor light source
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Measurements of Van der Waals Na 5889 A in He with piston compressor light source
Solid crystal ingot growth by traveling heater method for electroluminescent light sources
FACET at SLAC provides high charge, high peak current, low emittance electron beam that is bunched at THz wavelength scale during its normal operation. A THz light source based coherent transition radiation (CTR) from this beam would potentially be the brightest short-pulse THz source ever constructed. Efforts have been put into building this photon source together with a user area, to provide a platform to utilize this unique THz radiation for novel nonlinear and ultrafast phenomena researches and experiments. Being a long-time underutilized portion of the electromagnetic spectrum, terahertz (100 GHz {approx} 10 THz) spectral range is experiencing a renaissance in recent years, with broad interests from chemical and biological imaging, material science, telecommunication, semiconductor and superconductor research, etc. Nevertheless, the paucity of THz sources especially strong THz radiation hinders both its commercial applications and nonlinear processes research. FACET - Facilities for Accelerator science and Experimental Test beams at SLAC - provides 23 GeV electron beam with peak currents of {approx} 20 kA that can be focused down to 100 {mu}m{sup 2} transversely. Such an intense electron beam, when compressed to sub-picosecond longitudinal bunch length, coherently radiates high intensity EM fields well within THz frequency range that are orders of magnitude stronger than those available from laboratory tabletop THz sources, which will enable a wide variety of THz related research opportunities. Together with a description of the FACET beamline and electron beam parameters, this paper will report FACET THz radiation generation via coherent transition radiation and calculated photon yield and power spectrum. A user table is being set up along the THz radiation extraction sites, and equipped with various signal diagnostics including THz power detector, Michelson interferometer, sample stages, and sets of motorized optical components. This setup will also be presented. Potential THz research areas including studies of magnetism, ferroelectric switching dynamics, semiconductor devices and chemical reaction controls have already been proposed for the FACET THz area.
Conventional thermionic microwave and radiofrequency (RF) guns can offer high average beam current, which is important for synchrotron light and terahertz (THz) radiation source facilities, as well as for industrial applications. For example, the Advanced Photon Source at Argonne National Laboratory is a national synchrotron radiation light source research facility that utilizes thermionic RF guns. Yet, these existing thermionic guns are bulky, difficult to handle and install, easily detuned, very sensitive to thermal expansion, and are due for a major upgrade and replacement. Here, we present the design of a new, more stable and reliable gun with optimized electromagnetic performance, improved thermal engineering and a more robust cathode mounting technique, which is a critical step to improve the performance of existing and future light sources, industrial accelerators, and electron beam-driven terahertz sources. We will also present a fabricated gun prototype and show results of high-power and beam tests.
We study the feasibility of generating femtosecond duration Free-Electron Laser with a variable photon energy from 1.5 to 48 keV, using an electron bunch with the same characteristics of the LINAC Coherent Light Source (LCLS) bunch, and a planar undulator with additional focusing. We assume that the electron bunch energy can be changed, and the undulator has a variable gap, allowing a variable undulator parameter. It is assumed to be operated in an ultra-low charge and ultra-short pulse regime. We study the feasibility of a tunable, short pulse, X-ray FEL with photon energy from 1.5 to 48 keV, using an electron beam like the one in the LCLS and a 2:5 cm period, variable gap, planar undulator. The beam energy changes from 4.6 to 13.8 GeV, the electorn charge is kept at 10 pC, and the undulator parameter varies from 1 to 3. The undulator length needed to saturate the 48 keV FEL is about 55 m, with a peak power around 5 GW. At longer wavelength the saturation length is as short as 15 m, and the peak power around 20 GW. The results from the analytical models and the GENESIS simulations show that the system is feasible. The large wavelength range, full tunability and short, few femtosecond pulses, together with the large peak power, would provide a powerful research tool.
The Hard X-ray Nanoprobe (HXN) Beamline [1] of the National Synchrotron Light Source II (NSLS-II) is now available for general user experiments. This beamline was developed with the world’s most ambitious resolution goal for hard x-rays. Its initial performance target is to enable x-ray imaging experiments at a resolution of 10 nm, with an ultimate goal of reaching ~1 nm.
PTB has more than 20 years of experience in the calibration of space-based instruments using synchrotron radiation to cover the UV, VUV and X-ray spectral range. New instrumentation at the electron storage ring Metrology Light Source (MLS) opens up extended calibration possibilities within this framework. In particular, the set-up of a large vacuum vessel that can accommodate entire space instruments opens up new prospects. Moreover, a new facility for the calibration of radiation transfer source standards with a considerably extended spectral range has been put into operation. Besides, characterization and calibration of single components like e.g. mirrors, filters, gratings, and detectors is continued.
We present a dynamic monitoring method and monitoring system of grating angle, referred to as the Precise Angle Monitor (PAM), at U4B, a soft x-ray spherical grating monochromator (SGM) beam line at the National Synchrotron Light Source (NSLS). In an SGM, a photon energy scan is accomplished by rotating the grating angle precisely. After several decades of service, the monochromator at U4B developed instabilities that severely impacted the experimental program. Over several hours, either the spectral shape experienced distortions or the spectral peak shifted. In order to directly monitor the grating motion during scans, the optical head of a portable long trace profiler (PTLTP) was installed on U4B as the PAM. We find that the grating rotational motion is not ideal: (1) the scan steps are not smooth and there are high-frequency step angle errors; (2) there is also a low-frequency angle error; and (3) an unstable thermal expansion produces extra rotational error. Measurements of dynamic monitoring are presented, including grating rotation repeatability and thermal instability. The results illustrate the utility of dynamic monitoring of monochromator motion during actual operation.
We report on the beam dynamics studies and optimization methods for a high repetition rate (1 MHz) photoinjector based on a VHF normal conducting electron source. The simultaneous goals of beamcompression and reservation of 6-dimensional beam brightness have to be achieved in the injector, in order to accommodate a linac driven FEL light source. For this, a parallel, multiobjective optimization algorithm is used. We discuss the relative merits of different injector design points, as well as the constraints imposed on the beam dynamics by technical considerations such as the high repetition rate.
We present a description of a new goniospectroradiometric measurement system developed at the National Physical Laboratory (NPL). The instrument incorporates a modified array spectrometer and a series of rotary stages to allow measurement of the spectral radiant intensity distribution of a variety of different types of light source from 350 to 830 nm. Associated source properties such as chromaticity and correlated color temperature distributions and total spectral flux are then calculated from the radiant intensity data. A preliminary comparison with NPL's integrating sphere-based luminous flux scale shows agreement to within 0.4%, well within the combined measurement uncertainty. Measurements of the luminous intensity and color temperature distributions and the spectral total flux of a tungsten filament flux standard, a white LED cluster and a compact fluorescent source made using the goniospectroradiometer, are also presented.
Extreme ultraviolet (EUV) radiation from laser-produced plasma (LPP) has been thoroughly studied for application in mass production of next-generation semiconductor devices. One critical issue for the realization of an LPP-EUV light source for lithography is the conversion efficiency (CE) from incident laser power to EUV radiation of 13.5-nm wavelength (within 2% bandwidth). Another issue is solving the problem of damage caused when debris reaches an EUV collecting mirror. Here, we present an improved power balance model, which can be used for the optimization of laser and target conditions to obtain high CE. An integrated numerical simulation code has been developed for the target design. The code agrees well with experimental results not only for CE but also for detailed EUV spectral structure. We propose a two-pulse irradiation scheme for high CE, and reduced ion debris using a carbon dioxide laser and a droplet or a punch-out target. Using our benchmarked numerical simulation code, we find a possibility to obtain CE up to 6-7%, which is more than twice that achieved to date. We discuss the reduction of ion energy within the two-pulse irradiation scheme. The mitigation of energetic ions by a magnetic field is also discussed, and we conclude that no serious instability occurs due to large ion gyroradius.
Out-of-band (OOB) radiation, in contrast to the in-band radiation at 13.5 nm in a 2% bandwidth, emitted from dense tin plasmas generated by a laser was investigated for application as an extreme ultraviolet lithography light source. It was found that the continuum spectrum, which overwhelms the atomic and ionic line emissions, is responsible for the intense OOB radiation. The spectral distribution of the continuum emission matches that of blackbody radiation with a temperature of about 10 eV. The OOB radiation can be considerably suppressed by employing a minimum-mass target and short-pulse laser irradiation. Spectroscopic observations were made to examine the spatiotemporal behavior of the plasma immediately after laser irradiation. Prominent line broadening due to the Stark effect in the high-density plasma was observed, from which the variation of the electron density was deduced. The electron density and temperature on the target surface were 10{sup 17}-10{sup 18} cm{sup -3} and a few eV's, respectively, in the first 200 ns after laser illumination. In addition, the expansion velocities of neutral and singly ionized tin atoms were deduced from time-of-flight transients in the spectral emission.
We demonstrate fully phase-matched high harmonic emission spanning the water window spectral region important for nano- and bioimaging and a breadth of materials and molecular dynamics studies. We also generate the broadest bright coherent bandwidth ({approx_equal}300 eV) to date from any light source, small or large, that is consistent with a single subfemtosecond burst. The harmonic photon flux at 0.5 keV is 10{sup 3} higher than demonstrated previously. This work extends bright, spatially coherent, attosecond pulses into the soft x-ray region for the first time.
Abstract Optical transmission and scattering spectroscopic microscopy at the visible and adjacent wavelengths denote one of the most informative and inclusive characterization methods in material research. Unfortunately, restricted by the diffraction limit of light, it cannot resolve the nanoscale variation in light absorption and scattering, diagnostics of the local inhomogeneity in material structure and properties. Moreover, a large quantity of nanomaterials has anisotropic optical properties that are appealing yet hard to characterize through conventional optical methods. There is an increasing demand to extend the optical hyperspectral imaging into the nanometer length scale. In this work, we report a super-resolution hyperspectral imaging technique that uses a nanoscale white light source generated by superfocusing the light from a tungsten-halogen lamp to simultaneously obtain optical transmission and scattering spectroscopic images. A 6-nm spatial resolution in the visible to near-infrared wavelength regime (415–980 nm) is demonstrated on an individual single-walled carbon nanotube (SW-CNT). Both the longitudinal and transverse optical electronic transitions are measured, and the SW-CNT chiral indices can be identified. The band structure modulation in a SW-CNT through strain engineering is mapped.
The more than a century-old technique of X-ray diffraction in either angle or energy dispersive mode has been used to probe materials’ microstructure in a number of ways, including phase identification, stress measurements, structure solutions, and the determination of physical properties such as compressibility and phase transition boundaries. The study of high-pressure and high-temperature materials has strongly benefitted from this technique when combined with the high brilliance source provided by third generation synchrotron facilities, such as the Advanced Light Source (ALS) (Berkeley, CA, USA). Here we present a brief review of recent work at this facility in the field of X-ray diffraction under extreme conditions, including an overview of diamond anvil cells, X-ray diffraction, and a summary of three beamline capabilities conducting X-ray diffraction high-pressure research in the diamond anvil cell.
Synchrotron polychromatic X-ray microdiffraction is a particularly suitable technique to study in situ the effect of electromigration in metal interconnects as add spatial resolution to grain orientation and strain sensitivity. This technique has been extensively used at the Advanced Light Source to monitor changes in aluminum and copper interconnect test structures while high-density current is passed into them during accelerated tests at elevated temperature. One of the principal findings is the observation of electromigration-induced plasticity in the metal lines that appear during the very early stages of electromigration. In some of the lines, high density of geometrically necessary dislocation are formed leading to additional diffusion paths causing an enhancement of electromigration effect at test temperature. This paper presents an overview of the principal results obtained from X-ray microdiffraction studies of electromigration effects on aluminum and copper interconnects at the ALS throughout continuous efforts that spanned over a decade (1998-2008) from approximately 40 weeks of combined beamtime.
The fifth international user workshop focusing on high-power lasers at the Linac Coherent Light Source (LCLS) was held in Menlo Park, CA, USA on September 27-28, 2017. The workshop was co-organized by SLAC National Accelerator Laboratory (SLAC) and Los Alamos National Laboratory, and it had approximately 100 scientists in attendance. For the first time, this year’s workshop was combined with the larger LCLS/SSRL User Meeting. Participants discussed the recent experiments that have been performed using high power lasers at the LCLS-Matter in Extreme Conditions (MEC) endstation. Ten journal articles have been published during the previous year from research at the MEC instrument, and research performed at MEC has also contributed to several PhD theses. This workshop provided an opportunity for the scientific community to learn about recent accomplishments, as well as to discuss future facility upgrades. SLAC has already begun construction for a major upgrade of the X-ray free electron laser LCLS to LCLS-II, which made the community feedback particularly timely at this workshop. LCLS will be closed during 2019 for the upgrade and will re-commission new and enhanced capabilities in early 2020.
We require a means of determining the minimum achievable bunch length at the Linac Coherent Light Source (LCLS) at SLAC National Accelerator Laboratory. Current methods of measurement in the time domain do not have the resolution to measure ultra-short bunch lengths below 10 fs. An alternative method has been designed, using a single-shot near- to mid-infrared prism spectrometer for bunch length diagnosis in the frequency domain. This design requires the precision alignment of sensitive optical equipment and complete understanding of the spectrum reaching the spectrometer's detector surface. This paper provides information on preliminary simulations designed to model beam behavior in the optical set-up and at the detector surface for comparison to measured values as an indication of the current achievable optical alignment and the study of optimal detector orientation. The results of these simulations indicate the necessity for a method of greater precision in optical alignment and further study of achievable spectrometer range!