Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “light sensitive materials”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Advanced inorganic halide ceramic scintillators

Research in ceramic scintillators has steadily progressed alongside the research in bulk single crystal scintillator growth. As interest in faster scintillation material production with lower cost increases, more research on scintillating ceramics is needed. Research targeting optimization of optically transparent ceramics that can rival bulk-grown crystals grown may lower cost, increase yield, increase volume, and improve energy resolution in applications and systems currently using sodium iodide and alike. Ceramic scintillators that are dense (>5 g/cm 3 ), have high effective Z (>60), are bright (>40,000 photons/MeV), and are not sensitive to moisture as well as those that can be handled without protection are desired. Ultra-fast ceramic materials are also of interest. This paper presents an equipment design and technique to produce inorganic halide ceramic scintillators Cs 2 HfCl 6 (CHC) and Tl 2 HfCl 6 (THC). Improvements and optimization of CHC and THC ceramic scintillator fabrication are gauged by monitoring the energy resolution and peak position of 137 Cs full energy peak at 662 keV. With a 1-inch diameter CHC ceramic scintillator, energy resolution of 5.4% (FWHM) and light yield of 20,700 ph/MeV are achieved, while with a 16-mm diameter THC ceramic scintillator, energy resolution of 5.1% (FWHM) and light yield of 27,800 ph/MeV are achieved. Decay times of 0.6 μs (21%) and 3.0 μs (79%) are measured for CHC and 0.3 μs (13%) and 1.0 μs (87%) for THC. Here, both ceramic CHC and THC scintillators have similarly good proportionality data when compared to their single crystal counterparts.

36 MATERIALS SCIENCE↗

Light-Flash Wind-Direction Indicator

Proposed wind-direction indicator read easily by distant observers. Indicator emits bright flashes of light separated by interval of time proportional to angle between true north and direction from which wind blowing. Timing of flashes indicates direction of wind. Flashes, from high-intensity stroboscopic lights seen by viewers at distances up to 5 miles or more. Also seen more easily through rain and fog. Indicator self-contained, requiring no connections to other equipment. Power demand satisfied by battery or solar power or both. Set up quickly to provide local surface-wind data for aircraft pilots during landing or hovering, for safety officers establishing hazard zones and safety corridors during handling of toxic materials, for foresters and firefighters conducting controlled burns, and for real-time wind observations during any of variety of wind-sensitive operations.

Zysko, Jan A.↗

Differential Radiometers Using Fabry-Perot Interferometric Technique for Remote Sensing Determination of Various Atmospheric Trace Gases

New type of remote sensing instrument based upon the Fabry-Perot inte rferometric technique has been developed at NASA's Goddard Space Flight Center. Fabry-Perot interferometry (FPI) is a well known, powerful spectroscopic technique and one of its many applications is to be use d to measure greenhouse gases and also some harmful species in the at mosphere. With this technique, absorption of particular species is me asured and related to its concentration. A solid Fabry-Perot etalon is used as a frequency filter to restrict the measurement to particular absorption bands of the gas of interest. With adjusting the thicknes s of the etalon that separation (in frequency) of the transmitted fri nges can be made equal to the almost constant separation of the gas a bsorption lines. By adjusting the temperature of the etalon, which changes the index of refi-action of its material, the transmission fring es can be brought into nearly exact correspondence with absorption li nes of the particular species. With this alignment between absorption lines and fringes, changes in the amount of a species in the atmosph ere strongly affect the amount of light transmitted by the etalon and can be related to gas concentration. The instrument that we have dev eloped detects the absorption of various atmospheric trace gases in d irect or reflected sunlight. Our instrument employing Fabry-Perot interferometer makes use of two features to achieve high sensitivity. The first is high spectral resolution enabling one to match the width of an atmospheric absorption feature by the instrumental band pass. The second is high optical throughput enabled by using multiple spectral lines simultaneously. For any species that one wishes to measure, thi s first feature is available while the use of multiple spectral features can be employed only for species with suitable spectra and freedom from interfering species in the same wavelength region. We have deve loped an instrument for use as ground based, airborne and satellite s ensor for gases such as carbon dioxide (1570 nm), oxygen (762 nm and 768 nm lines sensitive to changes in oxygen pressure and oxygen temper ature) and water vapor (940 nm). Our current goal is to develop an ul tra precise, inexpensive, ground based device suitable for wide deplo yment as a validation instrument for the Orbiting Carbon Observatory (OCO) satellite. We show sensitivity measurements for CO2, 02, and H2 O, compare our measurements to those obtained using other types of sensors and discuss some of the peculiarities that must be addressed in order to provide the very high quality column detection required for solving problems about global distribution of greenhouse gases and cl imatological models. In another area of research we are interested in developing a small-size channel for CO2 capable of doing simultaneous measurements with the AERONET (Aerosol Robotic Network) at NASA, God dard to study the hypothesis that atmospheric aerosols affect the reg ional terrestrial carbon cycle. We present recent data from our groun d based measurements of O2, CO2, H2O and (13)CO2 and discuss extensio n of the technique to new species and applications.

Georgieva, E. M.↗

Advanced Autonomous Welding for Refabrication and Follow-On Testing of Previously Irradiated Nuclear Fuel

The performance of follow-on experiments using irradiated nuclear fuel at any point in its lifecycle is a critical step in understanding phenomena and behavior. Transient experiments with high-burnup fuel can deepen the understanding of fuel fragmentation, relocations, and dispersal under loss-of-coolant accidents. An advanced autonomous welding process to refabricate commercial fuel rods inside a hot cell was created and tested to enable flexible experiment approaches on fuels irradiated in commercial and test reactors. Irradiated light water reactor fuel test pins from experiments performed at the Advanced Test Reactor (ATR) at Idaho National Laboratory were used to demonstrate the refabrication process. The welding process was found to be sensitive to welding parameters but flexible such that multiple passes could be performed on the same location until a hermetic weld was obtained. The refabrication of rodlets and successful welds was also found to be sensitive to the preparation of the irradiated cladding and endcaps. Thorough defueling of the fuel at the weld location and proper sizing of the endcaps and backing material mitigated these issues. The use of strategically located heat sinks in contact with the cladding and endcap materials also increased welding and refabrication success. For this work, the test pins were sectioned to remove the original endcaps and fuel was removed from both ends of each rodlet. The reassembly of the rodlets was then completed in four steps, which included the press fitting of new endcaps, the circumferential welding of rodlet endcaps to the cladding, rodlet pressurization in a pressure chamber, and seal welding the rodlet under pressure. The integrity of the refabricated rodlets was then verified via helium leak checking inside a vacuum chamber. The advanced welding system is capable of refabricating rodlets up to 380 mm in length, and repressurizing them up to 15 500 kPa. The refabricated lengths of the rodlets used in this work ranged from 149 to 165 mm and the refabricated fuel stack heights ranged from 70.4 to 79.8 mm. Here, the rodlets were pressurized with argon to an average pressure of 3617 kPa, and the average leak rate after refabrication was 6.7 • 10 -8 cm 3 • s -1 .

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Integrating collapsible plasmonic gaps on near-field probes for polarization-resolved mapping of plasmon-enhanced emission in 2D material

Scanning near-field optical microscopy (SNOM) is an important technique used to study the optical properties of material systems at the nanoscale. In previous work, we reported on the use of nanoimprinting to improve the reproducibility and throughput of near-field probes including complicated optical antenna structures such as the ‘campanile’ probe. However, precise control over the plasmonic gap size, which determines the near-field enhancement and spatial resolution, remains a challenge. Here, we present a novel approach to fabricating a sub-20 nm plasmonic gap in a near-field plasmonic probe through the controlled collapse of imprinted nanostructures using atomic layer deposition (ALD) coatings to define the gap width. The resulting ultranarrow gap at the apex of the probe provides a strong polarization-sensitive near-field optical response, which results in an enhancement of the optical transmission in a broad wavelength range from 620 to 820 nm, enabling tip-enhanced photoluminescence (TEPL) mapping of 2-dimensional (2D) materials. We demonstrate the potential of this near-field probe by mapping a 2D exciton coupled to a linearly polarized plasmonic resonance with below 30 nm spatial resolution. This work proposes a novel approach for integrating a plasmonic antenna at the apex of the near-field probe, paving the way for the fundamental study of light-matter interactions at the nanoscale.

Zhou, Junze (ORCID:000000020682767X)↗

Deep HST/STIS Visible-Light Imaging of Debris Systems Around Solar Analog Hosts

We present new Hubble Space Telescope observations of three a priori known starlight-scattering circumstellar debris systems (CDSs) viewed at intermediate inclinations around nearby close-solar analog stars: HD 207129, HD202628, and HD 202917. Each of these CDSs possesses ring-like components that are more massive analogs of our solar systems Edgeworth Kuiper Belt. These systems were chosen for follow-up observations to provide imaging with higher fidelity and better sensitivity for the sparse sample of solar-analog CDSs that range over two decades in systemic ages, with HD 202628 and HD 207129 (both approx. 2.3 Gyr) currently the oldest CDSs imaged in visible or near-IR light. These deep (10-14 ks) observations, made with six-roll point-spread-function template visible-light coronagraphy using the Space Telescope Imaging Spectrograph, were designed to better reveal their angularly large debris rings of diffuse low surface brightness, and for all targets probe their exo-ring environments for starlight-scattering materials that present observational challenges for current ground-based facilities and instruments. Contemporaneously also observing with a narrower occulter position, these observations additionally probe the CDS endo-ring environments that are seen to be relatively devoid of scatterers. We discuss the morphological, geometrical, and photometric properties of these CDSs also in the context of other CDSs hosted by FGK stars that we have previously imaged as a homogeneously observed ensemble. From this combined sample we report a general decay in quiescent-disk F disk /F star optical brightness approx. t( exp.-0.8), similar to what is seen at thermal IR wavelengths, and CDSs with a significant diversity in scattering phase asymmetries, and spatial distributions of their starlight-scattering grains.

starlight-scattering circumstellar debris systems ↗

An Overview of the Patch Integral Method (PIM), a New Heat Transfer Analysis Tool for Hypersonic Wind Tunnel Facilities at NASA Langley

NASA Langley’s hypersonic wind tunnels are heavily leveraged for planetary missions. The data collection method in these tunnels is thermography, and surface temperature measurements of the model surface are collected and reduced to produce surface heating data, as seen in Fig 1. However, during model injection, no temperature data are collected, and thus conventional, integral heat transfer methods cannot be used to solve for surface heating. A method was developed in the 1990’s to reduce this data despite the data gap, known as the step approximation method. The method assumes that the film coefficient behaves as a step function, the model is semi-infinite, and thermal properties are constant. With these simplifying assumptions, a Laplace transform can be performed to result in an equation that takes the initial temperature of the model and a temperature at some point in time to back out the film coefficient at that time. This is the method that is used in the current thermographic data reduction software, IHEAT. While computationally light-weight, the step approximation has several issues associated with it. The time-history of temperature is not accounted for, which is vital as heat transfer is an integral process. Additionally, the required semi-infinite assumption is unnecessary and might be violated during runtime. Thermal variation of material properties can have a sizeable impact on heating results and are not modeled by the method. This method also takes multiple seconds to “collapse” to a steady state, which is undesirable from both a facility and data reduction standpoint. The method is also very sensitive to the “effective time” approximation, an approximation of when heating instantaneously starts (which is a nonphysical simplification), and a small variation in this value can result in an error in heating results.

J. S. Cheatwood↗

Development and validation of a gamma-ray detection response model for neutron-diagnosed subcritical experiments

In a neutron-diagnosed subcritical experiment, a highly sensitive and fast detector is required to accurately determine the true fission γ-ray emission rate from an object composed of special nuclear material under interrogation, in addition to a proper detector response model for use in forward modeling. We present the development of a detector response model that is based in GEANT4 and uses post-processing techniques to include photomultiplier tube time and pulse height response effects. We also define a set of detector performance evaluation metrics that emphasized our experimental objectives. A suite of time and pulse height response measurements for several diverse detector assemblies are described. These assemblies were simulated with this response model and benchmarked against the laboratory measurements. This response model reproduces the pulse height curve shapes and performance hierarchy of the measured detectors well. Additionally, the simulated time response curves exhibit reasonable agreement with counterpart measurements. These measurements and simulation results together suggest that a large volume EJ-299-49 plastic scintillator that is mated to an ultraviolet transmitting plastic light guide and relies on total internal reflection for light transport to the photocathode will provide significantly faster timing, increase pulse height by a factor of 3, and require 25% less γ rays to meet experimental needs, compared to the candidate detector design developed prior to the availability of this response model. Application of this response model and associated performance metrics in the context of large-scale design sensitivity studies is also discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Polymer Stabilized Paraboloid Liquid Crystal Microlenses with Integrated Pancharatnam–Berry Phase

Aspheric lenses reduce aberration and provide sharper images with improved spot size compared to spherical lenses. Here this paper demonstrates that applying shear flow can produce plano-concave liquid crystal (LC) lens arrays with paraboloid aspheric profiles. The focal length of individual lenses, with a 0.2 mm aperture, decreases from 0.67 to 0.45 mm as the chiral dopant increases from 0 to 6 wt%. The focal length is also sensitive to the polarization state of the incoming light. The lenses are stabilized by photopolymerizing with 6 wt% of reactive monomer added to the LC. A qualitative explanation for the flow-induced lens formation and the optical properties of the lenses is provided. The potential tunability of the lenses in various fields and their use as paraboloid reflectors are discussed.

36 MATERIALS SCIENCE↗

Enantioselective Se lattices for stable chiroptoelectronic processing media

Chiroptoelectronic devices are crucial for applications in quantum computing, spin optical communications, and magnetic recording. However, the limited efficiency and low stability of conventional circularly polarized light (CPL)-sensing materials have restricted their broader use. Here, we introduce atomic chiral Se nanorod (NRs) films as broadband CPL detectors, leveraging the intrinsic chirality and stability of Se nanocrystals. We also perform incident circular polarization (ICP)-Raman optical activity (ROA) to explore the chiroptical activity of the large-area films. The Se NRs thin films detected CPL across a broad range from ultraviolet (UV) to short-wavelength infrared (SWIR), with a responsivity dissymmetry factor of up to 0.4, maintaining high stability under ambient conditions for longer than 13 months. CPL-sensitive Se NRs with intrinsic chirality have potential applications in chiral photonic synapses, chiral spin devices, and CPL-sensitive photocatalysts. ICP-ROA mapping also advances the analysis of 2D chiral materials.

Nanophotonics and plasmonics↗

Isotopic investigations in the area of the Tunguska catastrophe in 1908 year

The hypotheses of the annihilation and thermonuclear character of the Tunguska explosion have been tested by measuring inductive Ar-39 radioactivity from K and Ca in rocks and soil under the explosion epicentrum. Ar-39 was not detected though its estimated radioactivity was expected to be 100 times higher than the radio-metrical plant sensitivity. These results testify against the nuclear nature of the Tunguska explosion. The contents of 11 elements in the ultrasmall quantity of matter of the silicate microspherules isolated from catastrophe peat layer at the explosion site were measured by method of neutron activation analysis. It was demonstrated that the enrichment of microspherules by light and volatile elements (Al, Na, Zn, Cs) and the impoverishment by more heavy and hard volatile ones (Fe, Co, Sc). It was shown that the microspherules were not the product of differentiation of the terrestrial soil or of an ordinary meteorite material. It was demonstrated that Pb isotopic content in catastrophe peat layer had more Pb-204, Pb-207, Pb-208 than Pb-206 as compared with Pb isotopic content of other peat layers and common Pb in this area. In the peat column taken at the Ostraya hill area in three nearcatastrophe layers, small increases of isotopic C-13 was determined. Isotopic C effect in the peat layer is confirmed also for the North peatbog. Observed isotopic changes are not accounted for by climatic changes or other physico-chemical reasons. They seem to be related to preservation in the peat of matter resembling carbonaceous chrondrites of the Cl type or more probably of cometary matter enriched much more in volatile elements.

Kolesnikov, E. M.↗

New Active Optical Technique Developed for Measuring Low-Earth-Orbit Atomic Oxygen Erosion of Polymers

Polymers such as polyimide Kapton (DuPont) and Teflon FEP (DuPont, fluorinated ethylene propylene) are commonly used spacecraft materials because of desirable properties such as flexibility, low density, and in the case of FEP, a low solar absorptance and high thermal emittance. Polymers on the exterior of spacecraft in the low-Earth-orbit (LEO) environment are exposed to energetic atomic oxygen. Atomic oxygen reaction with polymers causes erosion, which is a threat to spacecraft performance and durability. It is, therefore, important to understand the atomic oxygen erosion yield E (the volume loss per incident oxygen atom) of polymers being considered in spacecraft design. The most common technique for determining E is a passive technique based on mass-loss measurements of samples exposed to LEO atomic oxygen during a space flight experiment. There are certain disadvantages to this technique. First, because it is passive, data are not obtained until after the flight is completed. Also, obtaining the preflight and postflight mass measurements is complicated by the fact that many polymers absorb water and, therefore, the mass change due to water absorption can affect the E data. This is particularly true for experiments that receive low atomic oxygen exposures or for samples that have a very low E. An active atomic oxygen erosion technique based on optical measurements has been developed that has certain advantages over the mass-loss technique. This in situ technique can simultaneously provide the erosion yield data on orbit and the atomic oxygen exposure fluence, which is needed for erosion yield determination. In the optical technique, either sunlight or artificial light can be used to measure the erosion of semitransparent or opaque polymers as a result of atomic oxygen attack. The technique is simple and adaptable to a rather wide range of polymers, providing that they have a sufficiently high optical absorption coefficient. If one covers a photodiode with a uniformly thick sheet of semitransparent polymer such as Kapton H polyimide, then as atomic oxygen erodes the polymer, the short-circuit current from the photodiode will increase in an exponential manner with fluence. This nonlinear response with fluence results in a lack of sensitivity for measuring low atomic oxygen fluences. However, if one uses a variable-thickness polymer or carbon sample, which is configured as shown in the preceding figure, then a linear response can be achieved for opaque materials using a parabolic well for a circular geometry detector or a V-shaped well for a rectangular-geometry detector. Variable-thickness samples can be fabricated using many thin polymer layers. For semitransparent polymers such as Kapton H polyimide, there is an initial short-circuit current that is greater than zero. This current has a slightly nonlinear dependence on atomic oxygen fluence in comparison to opaque materials such as black Kapton as shown in the graph. For this graph figure, the total thickness of Kapton H was assumed to be 0.03 cm. The photodiode short-circuit current shown in the graph was generated on the basis of preliminary measurements-a total reflectance rho of 0.0424 and an optical absorption coefficient a of 146.5 cm(sup -1). In addition to obtaining on-orbit data, the advantage of this active erosion and erosion yield measurement technique is its simplicity and reliance upon well-characterized fluence witness materials as well as a nearly linear photodiode short-circuit current dependence upon atomic oxygen fluence. The optical technique is useful for measuring either atomic oxygen fluence or erosion, depending on the information desired. To measure the atomic oxygen erosion yield of a test material, one would need to have two photodiode sensors, one for the test material and one that uses a known erosion yield material (such as Kapton) to measure the atomic oxygen fluence.

Banks, Bruce A.↗

Sensitivity analysis of high-efficiency silicon solar-cell design parameters

Silicon solar cell design parameters were investigated to determine their bearing on cell efficiency. Among the parameters reviewed were: (1) bulk resistivity, (2) minority carrier lifetime cell thickness, (3) front junction depth, (4) front surface doping concentration, (5) front surface recombination velocity, and (6) back surface contact. The following were concluded: (1) there is good agreement between experimental and simulation results; (2) sheet material quality improvement is needed for high efficiency cells; (3) 20% cell of this design is feasible with 10 ms bulk lifetime material; and (4) for achieving efficiencies higher than 20% new cell designs including thin cells with light trapping and back surface field should be considered.

Mokashi, A. R.↗

The Electron Spectro-Microscopy (ESM) Beamline at NSLS-II

Photoelectron spectroscopy is a primary tool for the study of the electronic structure of materials and the chemical composition of surfaces. High-resolution angle-resolved photoemission spectroscopy (ARPES) has the unique ability to map the energy bands in momentum space. Furthermore, going beyond the single particle picture, the self-energy corrections caused by correlations in solids can be extracted from the analysis of the emission line shape. The current level of refinement, in terms of energy and angular resolution (ΔE < 1 meV, Δθ < 0.1°), makes the technique sensitive to the lowest energy excitations and the dynamics of electrons, which in turn virtually determine all the macroscopic properties of any system and govern the chemical, electrical, magnetic, and physical processes. Similarly important, X-ray photoelectron microscopy (XPEEM), combined with the low-energy electron microscopy (LEEM), is indispensable in probing the complexity of chemical, structural, electronic and magnetic properties of surfaces and shallow interfaces, with the spatial resolution of few tens of nanometer (nm). The Electron-Spectro-Microscopy beamline (ESM) has been recently commissioned at NSLS-II and is now in operation. The primary spectroscopic technique is photoemission, performed over a wide energy range with control of light polarization and in a variety of flux/resolution conditions. The beamline has two experimental end stations that allow to perform ARPES and XPEEM/LEEM, separately. The ARPES end station focuses on high energy-resolution work, with spot-size of a few microns. The XPEEM/LEEM end station is a full-field microscope (XPEEM) operating either with the synchrotron generated X-rays (XPEEM), or with an internal electron gun (LEEM). Spatial resolution is crucial in studies of newly synthesized complex materials since they are often initially available only as small specimens (typically micron size). Furthermore, chemical inhomogeneities on surfaces are often an integral part of surface chemical processes. Finally, the ESM beamline with X-ray spots of few microns is optimized to study the electronic structure of novel materials with microscopy capabilities.

47 OTHER INSTRUMENTATION↗

The DAMIC-M Low Background Chamber

The DArk Matter In CCDs at Modane (DAMIC-M) experiment isdesigned to search for light dark matter (m$_{χ}$ < 10 GeV/c$^{2}$)at the Laboratoire Souterrain de Modane (LSM) in France. DAMIC-Mwill use skipper charge-coupled devices (CCDs) as a kg-scale activedetector target. Its single-electron resolution will enable eV-scaleenergy thresholds and thus world-leading sensitivity to a range ofhidden sector dark matter candidates. A DAMIC-M prototype, the LowBackground Chamber (LBC), has been taking data at LSM since2022. The LBC provides a low-background environment, which has beenused to characterize skipper CCDs, study dark current, and measureradiopurity of materials planned for DAMIC-M. It also allows testingof various subsystems like readout electronics, data acquisitionsoftware, and slow control. This paper describes the technicaldesign and performance of the LBC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-energy synchrotron X-ray multimodal computed tomography: enabling multiscale materials characterization at NSLS-II

We report the commissioning of a multimodal computed tomography experimental setup at the 28-ID-2 (XPD) beamline of the National Synchrotron Light Source II. This high-energy (>60 keV) resource features a tunable X-ray beam size ranging from several millimetres to a few micrometres and enables comprehensive characterization of high-Z materials—an essential capability for nuclear and advanced materials research. It provides four complementary computed tomography modalities: X-ray absorption, X-ray fluorescence, X-ray diffraction, and pair distribution function tomography. A case study using a custom-made heterogeneous sample demonstrates these abilities to simultaneously capture atomic, elemental, and morphological information. This unique combination of imaging, structural, and chemical sensitive methods provides a holistic approach to study complex materials with amorphous and crystalline systems across multiple length scales.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Physics and applications of quantum dot lasers for silicon photonics

Abstract Photonic integrated circuits (PICs) have enabled numerous high performance, energy efficient, and compact technologies for optical communications, sensing, and metrology. One of the biggest challenges in scaling PICs comes from the parasitic reflections that feed light back into the laser source. These reflections increase noise and may cause laser destabilization. To avoid parasitic reflections, expensive and bulky optical isolators have been placed between the laser and the rest of the PIC leading to large increases in device footprint for on-chip integration schemes and significant increases in packaging complexity and cost for lasers co-packaged with passive PICs. This review article reports new findings on epitaxial quantum dot lasers on silicon and studies both theoretically and experimentally the connection between the material properties and the ultra-low reflection sensitivity that is achieved. Our results show that such quantum dot lasers on silicon exhibit much lower linewidth enhancement factors than any quantum well lasers. Together with the large damping factor, we show that the quantum dot gain medium is fundamentally dependent on dot uniformity, but through careful optimization, even epitaxial lasers on silicon can operate without an optical isolator, which is of paramount importance for the future high-speed silicon photonic systems.

36 MATERIALS SCIENCE↗

Comparison of Models for Ball Bearing Dynamic Capacity and Life

Generalized formulations for dynamic capacity and life of ball bearings, based on the models introduced by Lundberg and Palmgren and Zaretsky, have been developed and implemented in the bearing dynamics computer code, ADORE. Unlike the original Lundberg-Palmgren dynamic capacity equation, where the elastic properties are part of the life constant, the generalized formulations permit variation of elastic properties of the interacting materials. The newly updated Lundberg-Palmgren model allows prediction of life as a function of elastic properties. For elastic properties similar to those of AISI 52100 bearing steel, both the original and updated Lundberg-Palmgren models provide identical results. A comparison between the Lundberg-Palmgren and the Zaretsky models shows that at relatively light loads the Zaretsky model predicts a much higher life than the Lundberg-Palmgren model. As the load increases, the Zaretsky model provides a much faster drop off in life. This is because the Zaretsky model is much more sensitive to load than the Lundberg-Palmgren model. The generalized implementation where all model parameters can be varied provides an effective tool for future model validation and enhancement in bearing life prediction capabilities.

Rolling-element Fatigue↗