Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “light emitting diode”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

The Effect of Luminance Pattern on Nighttime Discomfort Glare Response - CRADA 653 (Abstract)

Light Emitting Diode (LED) adoption is critical for widespread energy savings from commercial outdoor lighting systems. A complaint from the public, concerns glare from LED light fixtures especially those with exposed LED arrays. This human factor study will examine luminance uniformity of the fixture aperture to identify parameters related to this response. The outcome will inform optical design by lighting manufacturers, retaining LED energy efficiency while mitigating glare. The results may also lead to improved industry standard glare metrics for lighting. Pacific Northwest National Laboratory’s (PNNL) Lighting Science and Technology Lab in Portland OR has a purpose-built apparatus with exposed LED arrays that have been used for prior work. It can easily be adapted for use in this experiment. Interchangeable templates will allow changing patterns for the stimulus. Glare ratings from the recruited subjects will be analyzed and reported in a peer-reviewed journal for application by luminaire manufacturers for improved products. The McClung Foundation’s interest is to better understand human perception of lighting, leading to more comfortable and effective visual environments. Members of the Foundation’s Technical Review Committee will be instrumental in reviewing the experimental design, analysis, and the final report. They will also help disseminate information about the results within the lighting community.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Manual control in space research on perceptual-motor functions under zero gravity conditions (L-10)

Are human abilities to control vehicles and other machines the same in space as those on Earth? The L-10 Manual Control Experiment of the First Materials Processing Tests (FMPT) started from this question. Suppose a pilot has the task to align the head of a space vehicle toward a target. His actions are to look at the target, to determine the vehicle movement, and to operate the manipulator. If the activity of the nervous system were the same as on Earth, the movements, of the eye and hand would become excessive because the muscles do not have to oppose gravity. The timing and amount of movement must be arranged for appropriate actions. The sensation of motion would also be affected by the loss of gravity because the mechanism of the otolith, the major acceleration sensor, depends on gravity. The possible instability of the sensation of direction may cause mistakes in the direction of control of manipulator movement. Thus, the experimental data can be used for designing man-machine systems in space, as well as for investigation of physiological mechanisms. In this experiment, the direction of vehicle heading is expressed by a light spot on an array of light emitting diodes and the manipulator is of a finger stick type. As the light spot moves up and down, the Japanese Payload Specialist, and the subject, must move the manipulator forward and backward to keep the movement of the light spot within the neighborhood of the central point of the display. The position of the light spot is computed in such a manner that when the stick is kept at the neutral position, a motion whose acceleration is proportional to the angle of deflection is added to the movement of the light spot. The Operator Describing Function, which is an expression of human control characteristics, can be calculated from 2 minutes of raw data of the light spot position and stick deflection. The 2 minutes of operation is called a run, and 8 runs with resting periods composes a session. The on-orbit experiment will be conducted on the second, fourth, and seventh days. One session of experiment of each of these days is conducted following the L-4 experiment, which uses the same apparatus. The Payload Specialist, aided by a Mission Specialist, will take our apparatus from a rack container, set up the apparatus, attach electrodes for measurements of eye movement and muscle activity, conduct the L-4 Visual Stability Experiment, conduct one session of the manual control experiment, and then dissemble and stow the apparatus. In addition to the flight experiment, pre-flight and post-flight experiments will be conducted. The data of three sessions on orbit will reflect adaption of physiological systems to microgravity. The data of post-flight experiments, on the other hand, will reflect re-adaptation of physiological systems to the gravity condition on the ground. Control data collected with and without psychological tension will be scheduled just prior to and long before launch.

Tada, Akira↗

An Integrated, Evidence-Based Approach to Transitioning to Operations: Specifications for Future Replacement Lights on ISS

The International Space Station (ISS) currently uses General Luminaire Assemblies (GLAs) as its primary light source. These GLAs are composed of fluorescent lighting and are integrated into the electrical system on Station. Seventy seven of these units are distributed throughout the vehicle, and many of the lights, having reached their lifespan, are no longer functional; while backup panels are available on orbit, it is anticipated that the supplies of fluorescents on the station will be exhausted by 2015. The ISS vehicle office is therefore preparing to replace all of the GLAs, with Solid State Light Assemblies (SSLAs) composed of white Light Emitting Diodes (LEDs). In the Spring of 2010, an announcement for the replacement lights was released. The announcement specified that proposed lighting systems should use LED technology, given certain power draw restrictions and no changes to how the lights are currently controlled (a central on/off switch per node, and a dial to turn on/off and increase brightness on each lighting unit). The replacement lights are to follow current specifications for brightness levels (lux) and color temperature (degrees Kelvin, or K). Reportedly, the lighting on orbit is dim and suboptimal. The average brightness of the lights (given all lights within a node are operational) is 291 lux; by comparison, recommended office lighting ranges from 200 to 500 lux, and daylight ranges on a typical overcast day, consists of 10,000 to 25,000 lux. Representatives from NASA Behavioral Health and Performance Element (BHP) and Human Factors and Habitability identified that maintaining current brightness levels limits visual acuity, work space, and the use of light as a countermeasure for improving circadian entrainment, hastening phase shifting, evoking acute alertness and enhancing performance. Revised lighting specifications are therefore needed to optimize the replacement lights for the ISS.

Leveton, Lauren↗

The Role of Competitions in Speeding Energy-Efficient Technology Development and Adoption

This conference paper, which will be submitted for publication in the 2020 ACEEE Summer Study on Energy Efficiency in Buildings, describes competition approaches used by the U.S. Department of Energy (DOE) Building Technologies Office (BTO) and other government agencies to encourage the development and adoption of innovative new energy-efficient, high-performing products while spurring external competition to maximize limited resources. The competition model helps to disrupt traditional thinking and introduce, expand, and evolve what’s possible within limited resource conditions. DOE BTO has sponsored technology competitions, including campaigns, challenges, prizes, and technology procurements to speed the uptake of more efficient refrigerators, clothes washers, air conditioners, and many types of highly efficient lighting technologies, including compact fluorescent lamps (CFLs) and light-emitting diode LED-based home and office luminaires, replacement lamps, and street lighting. In this paper, we will draw upon the technology competition frameworks employed by DOE BTO to support ongoing research and development efforts to illustrate the differences between the approaches and to identify which type is likely to be the most effective in a given technology status and market context. We’ll also share examples of the various technology competition types and results. A question-and-answer table helps readers compare and contrast the four competition types. The paper concludes with a summary of lessons learned from past DOE BTO competitions. The paper will be available in the ACEEE 2020 Summer Study proceedings and a related presentation will be given at the conference.

U.S. Department of Energy Building Technologies Of↗

Simulation of enhanced light extraction from periodic, disordered, and quasi-periodic OLED structures

Here we have developed a rigorous scattering matrix theory of light emission from periodically structured media using a Green’s function approach. We computationally simulate the spectral power inside the structure, incorporating Purcell factor enhancements, and find internal waveguiding modes and plasmonic losses. We simulate the light-outcoupling factor η out and describe how corrugations and structured media can enhance η out . We have extended our framework to describe non-periodic disordered arrays as well as aperiodic quasi-crystalline arrays. Flat organic light-emitting diodes (OLEDs) have low outcoupling with η out ~20% since most of the light is trapped in waveguided modes in higher index layers or lost to plasmonic excitations at the metal cathode. Periodically corrugated OLEDs can achieve highly enhanced η out ~65%-70% for pitch values between 1000 and 2000 nm, representing an enhancement factor >3 over planar structures. Periodic corrugations strongly diffract trapped waveguided and plasmonic modes to the emissive air cone. Disordered templates also can cause significant enhanced outcoupling with η out ~50%-55% for smaller nearest-neighbor separations of 300–400 nm. Quasi-crystalline tilings can also lead to enhancements of η out ~50%-55%. This framework can be utilized to design novel structured media that can generate high light extraction.

42 ENGINEERING↗

Literature Review of Optocouplers, Their polymer Components and Current Applicaitons

Optocouplers, also called optoisoloators and photocouplers, are devices that use a light emitting diode (LED) to conduct an electrical signal. The LED receives an electrical signal and emits light proportional to that signal. The light is then received by a photodetector and the signal is propagated. Optocouplers provide a high degree of electrical isolation and are therefore used extensively in commercial electronic equipment. Variations in optocouplers come from the type of photodetector used, the anatomy of the contents and the encapsulating polymers used. Current research involves investigating the tolerance of optocouplers to radiation for the purpose of improving spacecraft and satellites, as well as identifying failure mechanisms and improving design.

42 ENGINEERING↗

Optocouplers: Polymer Components, Current Applications and My Project Involvement [Slides]

Optocouplers, also called optoisolators and photocouplers, are devices that use a light emitting diode (LED) to conduct an electrical signal. The LED receives an electrical signal and emits light proportional to that signal. The light is then received by a phototransistor and the signal is propagated. Optocouplers provide a high degree of electrical isolation and are therefore used extensively in commercial electronic equipment. Variations in optocouplers come from the type of photodetector used, the anatomy of the contents and the encapsulating polymers used. Current research involves investigating the tolerance of optocouplers to radiation for the purpose of improving spacecraft and satellites, as well as identifying failure mechanisms and improving design. My project involvement at LANL includes conducting thermal and mechanical tests on three different cure profiles of epoxy to collect data about shrinkage, coefficient of thermal expansion, and degree of cure for a group wanting to produce their own optocoupler.

42 ENGINEERING↗

Cable Tester

NASA Tech Brief's provided Sonics Associates, Inc. with a method of saving many hours of testing time and money. James B. Cawthon, Sonics Vice-President, read about a device developed at Ames Research Center. Sonics adapted the device and produced an effective tester that uses a clocked shift register to apply a voltage to a cable under test. This is the active part of the Ames development, and the passive is a small box containing light emitting diodes (LEDs). When connected to the other end of the tested cable, the LEDs light in the same sequence as the generator. This procedure allows the technician to immediately identify a miswired cable.

Source record↗

Development of an optical sensor for measuring opacity changes in polyvinyl toluene scintillators

Polyvinyl toluene (PVT) based detectors are used in radiation portal monitors (RPMs) worldwide to detect the trafficking of illicit nuclear material. PVT scintillators, which are normally optically clear, have been observed to suffer internal fogging throughout their volume due to prolonged exposure to varying environmental conditions. These changes could lead to reduced performance for RPMs that utilize plastic scintillators. In this research, a proof of concept system, consisting of different color light emitting diodes (LEDs) and a single optical sensor (OS), were used to examine the change in light transmission through a PVT scintillator. This Optical Monitoring System (OMS), coupled with an environmentally exposed PVT detector, was tested in an environmental chamber where it was subjected to changes in temperature and humidity ranging from 55 °C at 100% relative humidity to –20 °C at 40% relative humidity. At temperatures below 10 °C, light transmission was reduced by 81% ± 8% for blue LEDs, 84% ± 5% for yellow LEDs, and 49% ± 4% for green LEDs. Similar reductions in detected light were not recorded when the OMS was tested with only air between the LEDs and OS. Therefore, the significant reductions in transmitted light were attributed to changes occurring within the PVT scintillator. These results indicate that a significant reduction in PVT opacity occurs due to wide environmental changes. A device such as the OMS could be used to track these changes and provide users an early indication that a portal monitor is suffering from reduced performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photoinitiator Selection and Concentration in Photopolymer Formulations towards Large-Format Additive Manufacturing

Photopolymers are an attractive option for large-format additive manufacturing (LFAM), because they can be formulated from structural thermosets and cure rapidly in ambient conditions under low-energy ultraviolet light-emitting diode (UV LED) lamps. Photopolymer cure is strongly influenced by the depth penetration of UV light, which can be limited in the 2–4 mm layer thicknesses typical of LFAM. Photoinitiator (PI) systems that exhibit photobleaching have proven useful in thick-section cure applications, because they generate a photoinitiation wavefront, but this effect is time-dependent. This study investigates the light transmission and through-thickness cure behavior in (meth)acrylate photopolymer formulations with the photobleaching initiator bis(2,4,6-trimethylbenzoyl)-phenylphosphine oxide (BAPO). Utilizing an optical model developed by Kenning et al., lower concentrations (0.1 wt% to 0.5 wt%) of BAPO were predicted to yield rapid onset of photoinitiation. In situ cure measurements under continuous UV LED irradiation of 380 mW/cm2 showed that a 0.1 wt% concentration of BAPO achieved peak polymerization rate within 2.5 s at a 3-mm depth. With only 1 s of irradiation at 1.7 W/cm2 intensity, the 0.1 wt% BAPO formulation also achieved the highest level of cure of the formulas tested. For an irradiation dose of 5.5 J/cm2 at a duration of 3.7 s, cured polymer specimens achieved a flexural strength of 108 MPa and a flexural modulus of 3.1 GPa. This study demonstrates the utility of optical modeling as a potential screening tool for new photopolymer formulations, primarily in identifying an upper limit to PI concentration for the desired cure depth. The results also show that photobleaching provides only a limited benefit for LFAM applications with short (1.0 s to 3.7 s) UV irradiation times and indicate that excess PI concentration can inhibit light transmission even under extended irradiation times up to 60 s.

36 MATERIALS SCIENCE↗

A measurement of the fast luminescent decays of the MV-50 LED.

The fast luminescent decay of the MV-50 GaAs doped Si light-emitting diode has been studied. This diode is found to provide a fast, inexpensive, bright, and convenient light source for the calibration of fast optical timing systems. A simple passive electronic module is described that allows driving the light source directly by a laboratory pulse generator.

Sutton, J. F.↗

Hand-Held Color Meters Based on Interference Filters

Small, inexpensive, hand-held optoelectronic color-measuring devices based on metal-film/dielectric-film interference filters are undergoing development. These color meters could be suitable for use in a variety of applications in which there are requirements to quantify or match colors for aesthetic purposes but there is no need for the high spectral resolution of scientific-grade spectrometers. Such applications typically occur in the paint, printing, and cosmetic industries, for example. The figure schematically depicts a color meter of this type being used to measure the color of a sample in terms of the spectrum of light reflected from the sample. Light from a white source (for example, a white light-emitting diode) passes through a collimating lens to the sample. Another lens collects some of the light reflected from the sample and focuses the light onto the input end of optical fiber. Light emerging from the output end of the optical fiber illuminates an array of photodetectors covered with metal/dielectric-film interference filters like those described in Metal/Dielectric-film Interference Color Filters (NPO-20217), NASA Tech Briefs, Vol. 23, No. 2 (February 1999), page 70. Typically, these are wide-band-pass filters, as shown at the bottom of the figure. The photodetector array need not be of any particular design: it could be something as simple as an assembly containing several photodiodes or something as elaborate as an active-pixel sensor or other imaging device. What is essential is that each of the photodetectors or each of several groups of photodetectors is covered with a metal/dielectric-film filter of a different color. In most applications, it would be desirable to have at least three different filters, each for a spectral band that contains one of the three primary additive red, green, and blue colors. In some applications, it may be necessary to have more than three different color filters in order to characterize subtle differences in color (or in the sensation of color) that cannot be characterized with sufficient precision by use of the primary colors alone.

Snyder, G. Jeffrey↗

Powerful Organic Molecular Oxidants and Reductants Enable Ambipolar Injection in a Large-Gap Organic Homojunction Diode

Doping has proven to be a critical tool for enhancing the performance of organic semiconductors in devices like organic light-emitting diodes. However, the challenge in working with high-ionization-energy (IE) organic semiconductors is to find p-dopants with correspondingly high electron affinity (EA) that will improve the conductivity and charge carrier transport in a film. Here, we use an oxidant that has been recently recognized to be a very strong p-type dopant, hexacyano-1,2,3-trimethylene-cyclopropane (CN6-CP). The EA of CN6-CP has been previously estimated via cyclic voltammetry to be 5.87 eV, almost 300 meV higher than other known high-EA organic molecular oxidants. We measure the frontier orbitals of CN6-CP using ultraviolet and inverse photoemission spectroscopy techniques and confirm a high EA value of 5.88 eV in the condensed phase. The introduction of CN6-CP in a film of large-band-gap, large-IE phenyldi(pyren-1-yl)phosphine oxide (POPy 2 ) leads to a significant shift of the Fermi level toward the highest occupied molecular orbital and a 2 orders of magnitude increase in conductivity. Using CN6-CP and n-dopant (pentamethylcyclopentadienyl)(1,3,5-trimethylbenzene)ruthenium (RuCp*Mes)2, we fabricate a POPy 2 -based rectifying p–i–n homojunction diode with a 2.9 V built-in potential. Blue light emission is achieved under forward bias. Furthermore, this effect demonstrates the dopant-enabled hole injection from the CN6-CP-doped layer and electron injection from the (RuCp*Mes) 2 -doped layer in the diode.

36 MATERIALS SCIENCE↗

Room-temperature spin injection across a chiral perovskite/III–V interface

Spin accumulation in semiconductor structures at room temperature and without magnetic fields is key to enable a broader range of optoelectronic functionality. Current efforts are limited owing to inherent inefficiencies associated with spin injection across semiconductor interfaces. Here we demonstrate spin injection across chiral halide perovskite/III-V interfaces achieving spin accumulation in a standard semiconductor III-V (Al x Ga 1-x ) 0.5 In 0.5 P multiple quantum well light-emitting diode. The spin accumulation in the multiple quantum well is detected through emission of circularly polarized light with a degree of polarization of up to 15 ± 4%. The chiral perovskite/III-V interface was characterized with X-ray photoelectron spectroscopy, cross-sectional scanning Kelvin probe force microscopy and cross-sectional transmission electron microscopy imaging, showing a clean semiconductor/semiconductor interface at which the Fermi level can equilibrate. Finally, these findings demonstrate that chiral perovskite semiconductors can transform well-developed semiconductor platforms into ones that can also control spin.

14 SOLAR ENERGY↗

Design and optimization of high temperature optocouplers as galvanic isolation

The commercial InGaN-based (blue and green) and AlGaInP-based (red) multiple quantum well (MQW) lighting emitting diodes (LEDs) were studied in a wide range of temperatures up to 800 K for their light emission and detection (i.e., LEDs operated under reverse bias as photodiodes (PDs)) characteristics. The results indicate the feasibility of integrating a pair of selected LEDs to fabricate high temperature (HT) optocouplers, which can be utilized as galvanic isolation to replace the bulky isolation transforms in the high-density power modules. A detailed study on LEDs and PDs were performed. The external quantum efficiency (EQE) of the LED and PDs were calculated. Higher relative external quantum efficiency (EQE) and lower efficiency droops with temperatures are obtained from the blue and green LEDs for display compared with the blue one for lighting and red LED for display. The blue for lighting and red for display devices show superior responsivity, specific detectivity (D*), and EQE compared with blue and green for display when operated as PDs. The results suggest that red LED devices for display can be used to optimize HT optocouplers due to the highest wavelength overlapping compared with others.

42 ENGINEERING↗

Low-cost, portable optical sensors for critical mineral prospecting and process monitoring

A combination of projected demand increases for economically critical minerals and a monopolistic global marketplace for these minerals has caused concern over supply chain vulnerabilities, which would impact energy, national defense, and advanced technology production. Domestic production of critical minerals is hindered by expensive and non-portable methods for analyzing metal concentration, which is vital both for resource prospecting and process monitoring. Here, a suite of luminescent materials along with portable instrumentation is presented for fluorescence-based detection of trace concentrations of critical minerals (cobalt, rare earth elements, and aluminum) as well as common gangue metals that are removed during processing (iron and aluminum). A metal-organic framework comprised of zinc, adenine, and trimesic acid immobilized on a fiber optic tip is capable of sensing part-per-billion concentrations of terbium, europium, dysprosium, and samarium through a sensitization approach, in which individual elements produce characteristic emission bands enabling multiple rare earths to be simultaneously detected and distinguished. A deep-UV light emitting diode is used as the excitation source, while a portable spectrometer is used to detect the emitted light. A similar optical set-up is coupled with two different carbon dot materials, which can detect low part-per-million concentrations of cobalt and iron in acidic environments. Metal-organic framework thin films comprised of copper and 2-aminoterephthalic acid are used in tandem with a portable optical set-up to further detect aluminum, with successful deployment in real fly ash leachates. Taken together, these technologies provide an inexpensive and sensitive path towards characterizing economically critical metals.

characterization and extraction of rare earth elem↗

Enhanced Video-Oculography System

A previously developed video-oculography system has been enhanced for use in measuring vestibulo-ocular reflexes of a human subject in a centrifuge, motor vehicle, or other setting. The system as previously developed included a lightweight digital video camera mounted on goggles. The left eye was illuminated by an infrared light-emitting diode via a dichroic mirror, and the camera captured images of the left eye in infrared light. To extract eye-movement data, the digitized video images were processed by software running in a laptop computer. Eye movements were calibrated by having the subject view a target pattern, fixed with respect to the subject s head, generated by a goggle-mounted laser with a diffraction grating. The system as enhanced includes a second camera for imaging the scene from the subject s perspective, and two inertial measurement units (IMUs) for measuring linear accelerations and rates of rotation for computing head movements. One IMU is mounted on the goggles, the other on the centrifuge or vehicle frame. All eye-movement and head-motion data are time-stamped. In addition, the subject s point of regard is superimposed on each scene image to enable analysis of patterns of gaze in real time.

Moore, Steven T.↗

Computational Modeling to Limit the Impact Displays and Indicator Lights Have on Habitable Volume Operational Lighting Constraints

NASA has demonstrated an interest in improving astronaut health and performance through the installment of a new lighting countermeasure on the International Space Station. The Solid State Lighting Assembly (SSLA) system is designed to positively influence astronaut health by providing a daily change to light spectrum to improve circadian entrainment. Unfortunately, existing NASA standards and requirements define ambient light level requirements for crew sleep and other tasks, yet the number of light-emitting diode (LED) indicators and displays within a habitable volume is currently uncontrolled. Because each of these light sources has its own unique spectral properties, the additive lighting environment ends up becoming something different from what was planned or researched. Restricting the use of displays and indicators is not a solution because these systems provide beneficial feedback to the crew. The research team for this grant used computer-based computational modeling and real-world lighting mockups to document the impact that light sources other than the ambient lighting system contribute to the ambient spectral lighting environment. In particular, the team was focused on understanding the impacts of long-term tasks located in front of avionics or computer displays. The team also wanted to understand options for mitigating the changes to the ambient light spectrum in the interest of maintaining the performance of a lighting countermeasure. The project utilized a variety of physical and computer-based simulations to determine direct relationships between system implementation and light spectrum. Using real-world data, computer models were built in the commercially available optics analysis software Zemax Optics Studio(c). The team also built a mockup test facility that had the same volume and configuration as one of the Zemax models. The team collected over 1200 spectral irradiance measurements, each representing a different configuration of the mockup. Analysis of the data showed a measurable impact on ambient light spectrum. This data showed that obvious design techniques exist that can be used to bind the ambient light spectrum closer to the planned spectral operating environment for the observer's eye point. The following observations should be considered when designing an operational environment that is dominated by computer displays. When more light is directed into the field of view of the observer, the greater the impact it will make on various human factors issues that depend on spectral shape and intensity. Because viewing angle has a large part to play in the amount of light flux on the crewmember's retina, beam shape, combined with light source location is an important factor for determining percent probable incident flux on the observer from any combination of light sources. Computer graphics design and display lumen output are major factors influencing the amount of spectrally intense light projected into the environment and in the viewer's direction. Use of adjustable white point display software was useful only if the predominant background color was white and if it matched the ambient light system's color. Display graphics that used a predominantly black background had the least influence on unplanned spectral energy projected into the environment. Percent reflectance makes a difference in total energy reflected back into an environment, and within certain architectural geometries, reflectance can be used to control the amount of a light spectrum that is allowed to perpetuate in the environment. Data showed that room volume and distance from significant light sources influence the total spectrum in a room. Smaller environments had a homogenizing effect on total light spectrum, whereas light from multiple sources in larger environments was less mixed. The findings indicated above should be considered when making recommendations for practice or standards for architectural systems. The ambient lighting system, surface reflectance, and display and indicator implementation all factor into the users' spectral environment. A variety of low-cost solutions exist to mitigate the impact of light from non-architectural lighting systems, and much potential for system automation and integration of display systems with the ambient environment. This team believes that proper planning can be used to avoid integration problems and also believes that human-in-the-loop evaluations, real-world test and measurement, and computer modeling can be used to determine how changes to a process, display graphics, and architecture will help maintain the planned spectral operating lighting environment.

Clark, T. A.↗