Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “light detection and ranging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Geoscience Laser Altimeter System: Characteristics and Performance of the Altimeter Receiver

The Geoscience Laser Altimeter System (GLAS) on board ICESat spacecraft measures the surface height (altimetry) via the time of flight of its 1064 nm laser pulse. The GLAS laser transmitter produces 6 ns wide pulses with 70 mJ energy at 1064 nm at a 40 Hz rate. The altimeter receiver consists of a telescope, aft optics, a silicon avalanche photodiode, and electronic amplifiers. The transmitted and echo pulse waveforms are digitized at 1 GHz rate. The laser pulse time of flight is determined on the ground from the two digitized pulse waveforms and their positions in the full waveform record (about 5.4 ms ong) by computing the pulse centroids or by curve fitting. The GLAS receiver algorithms in on board software selects the two waveform segments containing the transmitted and the echo pulses and sends them to ground. The probability of echo pulse detection and the accuracy of time of flight measurement depend on the received signal level, the background light within the receiver field of view, the inherent detector and amplifier noise, the quantization of the digitizer, and some times by cloud obscurations. A receiver model has been developed to calculate the probability of detection and accuracy of the altimeter measurements with these noise sources. From prelaunch testing, the minimum detectable echo pulse energy for 90% detection probability was about 0.1 fj/pulse onto the detector. Such a receiver sensitivity allows GLAS to measure the surface height through clouds with optical density less than 2. The echo pulse energy required to achieve 10 cm ranging accuracy was found to be about 3 times higher than the minimum detectable signal level. The smallest single shot range measurement error, which was determined by ranging to a fixed target with strong echo pulses and no background light, was 2 to 3cm. The maximum linear response echo pulse energy was 10 fJ/pulse for the strongest echo signals, assuming a Lambertian scattering snow surface, clear sky atmosphere transmission, and no pulse width spreading due to surface slopes. Results from the initial 38 days of GLAS operation on-orbit with Laser 1, showed the echo pulse energies varied, as expected, over a wide dynamic range due to the variability of atmosphere transmission and Earth surface characteristics. The receiver was able to reliably detect the ground surface echoes and measure time of flight under such dynamic conditions, except when there were dense clouds. When over Antarctica, the echo pulse energies were several times stronger than predicted. This suggests that the 1064 nm backscattering from the snow pack and ice-sheet &ce are not completely Lambertian but is somewhat peaked at opposit.ion. With Laser 1, the peak amplitude of the echo pulses from flat ice sheets under clear sky conditions exceeded the linear response range of the receiver, causing some pulse waveform distortion due to saturation. We have characterized the effects of receiver saturation on the time of flight, pulse width, and pulse energy measurements for flat surface by testing a night spare detector in the lab with simulated echo pulses. A data processing algorithm that minimizes the errors due to saturation for these measurements are described.

Sun, Xiao-Li↗

Detection of H2O and Evidence for TiO VO in an Ultra Hot Exoplanet Atmosphere.

We present a primary transit observation for the ultra-hot (Teq approx. 2400 K) gas giant expolanet WASP-121b, made using the Hubble Space Telescope Wide Field Camera 3 in spectroscopic mode across the 1.12-1.64 micron wavelength range. The 1.4 microns water absorption band is detected at high confidence (5.4(sigma)) in the planetary atmosphere. We also reanalyze ground-based photometric light curves taken in the B, r′, and z′ filters. Significantly deeper transits are measured in these optical bandpasses relative to the near-infrared wavelengths. We conclude that scattering by high-altitude haze alone is unlikely to account for this difference and instead interpret it as evidence for titanium oxide and vanadium oxide absorption. Enhanced opacity is also inferred across the 1.12-1.3 micron wavelength range, possibly due to iron hydride absorption. If confirmed, WASP-121b will be the first exoplanet with titanium oxide, vanadium oxide, and iron hydride detected in transmission. The latter are important species in M/L dwarfs and their presence is likely to have a significant effect on the overall physics and chemistry of the atmosphere, including the production of a strong thermal inversion.

Spectroscopy↗

LSBGnet: an improved detection model for low-surface brightness galaxies

ABSTRACT The Chinese Space Station Telescope (CSST) is scheduled to launch soon, which is expected to provide a vast amount of image potentially containing low-surface brightness galaxies (LSBGs). However, detecting and characterizing LSBGs is known to be challenging due to their faint surface brightness, posing a significant hurdle for traditional detection methods. In this paper, we propose LSBGnet, a deep neural network specifically designed for automatic detection of LSBGs. We established LSBGnet-SDSS model using data set from the Sloan Digital Sky Survey (SDSS). The results demonstrate a significant improvement compared to our previous work, achieving a recall of 97.22 per cent and a precision of 97.27 per cent on the SDSS test set. Furthermore, we use the LSBGnet-SDSS model as a pre-training model, employing transfer learning to retrain the model with LSBGs from Dark Energy Survey (DES), and establish the LSBGnet-DES model. Remarkably, after retraining the model on a small DES sample, it achieves over 90 per cent precision and recall. To validate the model’s capabilities, we utilize the trained LSBGnet-DES model to detect LSBG candidates within a selected 5 sq. deg area in the DES footprint. Our analysis reveals the detection of 204 LSBG candidates, characterized by a mean surface brightness range of $23.5\ \mathrm{ mag}\ \mathrm{ arcsec}^{-2}\le \bar{\mu }_{\text{eff}}(g)\le 26.8\ \mathrm{ mag}\ \mathrm{ arcsec}^{-2}$ and a half-light radius range of 1.4 arcsec ≤ r1/2 ≤ 8.3 arcsec. Notably, 116 LSBG candidates exhibit a half-light radius ≥2.5 arcsec. These results affirm the remarkable performance of our model in detecting LSBGs, making it a promising tool for the upcoming CSST.

Su, Hao (ORCID:0009000778888301)↗

Signatures of vacuum birefringence in low-power flying focus pulses

Vacuum birefringence produces a differential phase between orthogonally polarized components of a weak electromagnetic probe in the presence of a strong electromagnetic field. Despite representing a hallmark prediction of quantum electrodynamics, vacuum birefringence remains untested in pure light configurations due to the extremely large electromagnetic fields required for a detectable phase difference. Here, we exploit the programmable focal velocity and extended focal range of a flying focus laser pulse to substantially lower the laser power required for detection of vacuum birefringence. In the proposed scheme, a linearly polarized x-ray probe pulse counterpropagates with respect to a flying focus pulse, whose focus moves at the speed of light in the same direction as the x-ray probe. The peak intensity of the flying focus pulse overlaps the probe over millimeter-scale distances and induces a polarization ellipticity on the order of 10 − 10 , which lies within the detection sensitivity of existing x-ray polarimeters. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Deeper, Wider, Faster programme: exploring stellar flare activity with deep, fast cadenced DECam imaging via machine learning

ABSTRACT We present our 500 pc distance-limited study of stellar flares using the Dark Energy Camera as part of the Deeper, Wider, Faster programme. The data were collected via continuous 20-s cadence g-band imaging and we identify 19 914 sources with precise distances from Gaia DR2 within 12, ∼3 deg2, fields over a range of Galactic latitudes. An average of ∼74 min is spent on each field per visit. All light curves were accessed through a novel unsupervised machine learning techniques designed for anomaly detection. We identify 96 flare events occurring across 80 stars, the majority of which are M dwarfs. Integrated flare energies range from ∼1031–1037 erg, with a proportional relationship existing between increased flare energy with increased distance from the Galactic plane, representative of stellar age leading to declining yet more energetic flare events. In agreement with previous studies we observe an increase in flaring fraction from M0 to M6 spectral types. Furthermore, we find a decrease in the flaring fraction of stars as vertical distance from the galactic plane is increased, with a steep decline present around ∼100 pc. We find that $\sim 70{{\ \rm per\ cent}}$ of identified flares occur on short time-scales of <8 min. Finally, we present our associated flare rates, finding a volumetric rate of 2.9 ± 0.3 × 10−6 flares pc−3 h−1.

Webb, S.↗

SS Cygni as a hard X-ray source identified with the scanning modulation collimator on HEAO 1

Hard X-ray emission from a 15 min by 1.5 deg area containing SS Cygni had previously been reported and identified with SS Cygni. This paper reports a 0.4 sq arc min measurement of the position of the X-ray source with the HEAO 1 modulation collimator experiment which leads to an unequivocal identification of SS Cygni as an X-ray emitter in the 2-10 keV energy range. The historical light curve in hard X-rays was also investigated by analyzing relevant Uhuru data, and two instances of possible source detection in the 2-6 keV band were noted. From Ariel 5 observations it is calculated that the X-ray luminosity of SS Cygni in the 2-10 keV energy range is of the order of 10 to the 33rd erg/sec in the optical low state and probably at least an order of magnitude less in the high state. By contrast, the soft X-ray luminosity increases by an order of magnitude between the optical low and high states. A coronal model or accretion onto the white dwarf can account for the inverse correlation of the soft and hard X-rays.

Fabbiano, G.↗

Extending the dark matter reach of water Cherenkov detectors using Jupiter

We propose the first method for water Cherenkov detectors to constrain GeV-scale dark matter (DM) below the solar evaporation mass. While previous efforts have highlighted the Sun and Earth as DM capture targets, we demonstrate that Jupiter is a viable target. Jupiter’s unique characteristics, such as its lower core temperature and significant gravitational potential, allow it to capture and retain light DM more effectively than the Sun, particularly in the mass range below 4 GeV where direct detection sensitivity diminishes. Our calculations provide the first sensitivity estimates to GeV-scale annihilating DM within Jupiter, predicting Hyper-K can reach spin dependent cross sections as low as $𝜎^{SD}_{𝑝⁢𝜒}$ = 2×10 −35 cm 2 for DM masses below 2 GeV. This surpasses current solar limits and direct detection results. We additionally provide estimates for Super-K ORCA, and the IceCube-Upgrade, showing that these experiments could provide complimentary bounds to direct detection experiments.

79 ASTRONOMY AND ASTROPHYSICS↗

Real time pre-detection dynamic range compression

A real time, pre-detection optical dynamic range compression system uses a photorefractive crystal, such as BaTiO3 or LiNbO3, in which light induced scattering from crystal inhomogeneities of the optical input occurs as a nonlinear function of the input intensity. The greater the intensity, the faster random interference gratings are created to scatter the incident light. The unscattered portion of the optical signal is therefore reduced in dynamic range over time. The amount or range of dynamic range compression may be controlled by adjusting the time of application of the unscattered crystal output to the photodetector with regard to the time of application of the optical input to the crystal.

Liu, Hua-Kuang↗

Video Guidance Sensor System with Laser Rangefinder

A video guidance sensor system for use in automated docking of a chase vehicle with a target vehicle wherein the chase. vehicle includes a laser rangefinder that uses pulse or phase time of flight measurement to measure distance. The laser rangefinder includes a diode laser pulse or phase driver that produces an output signal to a timing element and simultaneously operates a laser diode. The laser diode produces an intense light beam of a predetermined wavelength which is directed to retroreflectors that are positioned on a passive target. The laser rangefinder includes an avalanche photodetector that produces a corresponding output signal when detecting light reflected from the retroreflectors. The timing element measures a time interval between the output of the laser diode and the detection of light and supplies a corresponding output signal to a computer in order to determine the range of the target vehicle relative to the chase vehicle.

Richard T Howard↗

UV laser long-path absorption spectroscopy

Long path Differential Optical Absorption Spectroscopy (DOAS) using a picosecond UV laser as a light source was developed in our institute. Tropospheric OH radicals are measured by their rotational absorption lines around 308 nm. The spectra are obtained using a high resolution spectrograph. The detection system has been improved over the formerly used optomechanical scanning device by application of a photodiode array which increased the observed spectral range by a factor of 6 and which utilizes the light much more effectively leading to a considerable reduction of the measurement time. This technique provides direct measurements of OH because the signal is given by the product of the absorption coefficient and the OH concentration along the light path according to Lambert-Beers law. No calibration is needed. Since the integrated absorption coefficient is well known the accuracy of the measurement essentially depends on the extent to which the OH absorption pattern can be detected in the spectra. No interference by self generated OH radicals in the detection lightpath has been observed. The large bandwidth (greater than 0.15 nm) and the high spectral resolution (1.5 pm) allows absolute determination of interferences by other trace gas absorptions. The measurement error is directly accessible from the absorption-signal to baseline-noise ratio in the spectra. The applicability of the method strongly depends on visibility. Elevated concentrations of aerosols lead to considerable attenuation of the laser light which reduces the S/N-ratio. In the moderately polluted air of Julich, where we performed a number of OH measurement spectra. In addition absorption features of unidentified species were frequently detected. A quantitative deconvolution even of the known species is not easy to achieve and can leave residual structures in the spectra. Thus interferences usually increase the noise and deteriorate the OH detection sensitivity. Using diode arrays for sensitive absorption measurements some specific problems of those detectors have to be solved experimentally (i.e. fixed pattern noise, dark signal noise, nonuniform efficiency of individual elements, spatial sensitivity variations). In order to improve the low spatial resolution we performed laboratory studies using a multiple reflection cell to convert the long path technique to a real in situ point measurement. Under the conditions of field experiments in Julich residual absorbance signals at present are about 1.5x10(exp -4) corresponding to an OH detection sensitivity of 2x10(exp 6) OH/cm(exp 3) using a light path of 5.8 km. Total integration times for one measurement point vary between a few minutes and an hour.

Dorn, Hans-Peter↗

Resolving femtosecond photoinduced energy flow: capture of nonadiabatic reaction pathway topography and wavepacket dynamics from photoexcitation through the conical intersection seam (Final Technical Report)

The dynamics that take place within just tens to hundreds of femtoseconds following the absorption of light by a molecule can play a critical role in how the absorbed energy is directed, allowing it to be used for a specific function or dissipated harmlessly. The form of chemical change that occurs rapidly in these molecules is called a “nonadiabatic electronic transition.” Such transitions are known to mediate energy flow in natural biological systems such as the ultraviolet photoprotection mechanism of DNA and the first step of the human vision response. Understanding how these mechanisms work precisely may help scientists achieve controlled manipulation of solar energy or optical control of a wide range of energy management functions in artificial systems. Experimental methods, however, have not yet allowed a precisely resolved and complete measurement of nonadiabatic electronic transitions. This constitutes a major obstacle to progress in the field. For progress to occur that would inform a wide body of research aiming to efficiently harness the energy of light for practical purposes, it is especially important to benchmark computational models of the molecules undergoing these rapid changes with experimental measurements, in order to learn which models are accurate. With Dept. of Energy funding, we have made strong progress towards establishing a new optical method for experimentally detecting the full nonadiabatic electronic transition. This requires having coordinated pulses of light covering the visible through the mid-infrared range of the electromagnetic spectrum that last only ten femtoseconds. We have developed a new, relatively simple approach for generating such pulses of laser light, and have incorporated them into a time-resolved spectrometer for measuring rapid changes in molecules. These tools can provide the greater precision and new types of data that are needed to benchmark computational models of molecular change and thus to make progress in the field. Our tools were tested on graphene, an excellent solid-state sample for verifying the capabilities and limitations of our instrumentation. The investment made in these tools by the Dept. of Energy Office of Science will allow new fundamental scientific understanding of energy dynamics in molecules in future studies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Solar Neutrino Detection with a Pixelated Liquid-Argon Time Projection Chamber

This thesis presents a study of low-energy solar neutrino detection using large-scale LArTPCs, focussing on novel pixelated readout technologies. Solar neutrinos offer a unique probe of fundamental neutrino properties and solar physics, but their detection in the MeV range is challenged by backgrounds. We investigate two complementary technologies: SoLAr, which integrates LArPix-based pixelated charge collection with Silicon Photomultipliers (SiPMs) in a hybrid anode design for simultaneous charge and light detection; and Q-Pix, a triggerless pixelated readout architecture based on charge integrate-reset circuits with local clocks, where Reset Time Differences encode ionisation waveforms via time-to-charge conversion. Two SoLAr prototypes were developed and operated, demonstrating VUV-sensitive SiPM performance in liquid argon and accurate charge-light signal matching with a charge detection threshold of $\sim 100 \mathrm{keV}$. We also implement a complete simulation and reconstruction framework, incorporating realistic detector geometry, electron transport, readout response, and detailed signal and background models, including intrinsic argon and radon progeny, as well as site-specific $\gamma$-ray and neutron fluxes. For Q-Pix, we demonstrate that with a pixel size of $4\times 4$ mm$^2$ and a reset threshold of 1 fC ($\sim 0.1475$ MeV), full-scale operation produces data volumes below 1 PB per 10 ktonne-year. For SoLAr, assuming a shielded DUNE-like detector and 100 ktonne-year exposure, we project uncertainties of $0.90\times 10^{-5}$ eV$^2$ on $\Delta m^2_{21}$ and 0.033 on $\sin^2\theta_{12}$, improving to $0.46\times 10^{-5}$ eV$^2$ and 0.025 with 400 kilotonne-year. At this higher exposure, we also obtain a day–night flux asymmetry at the level of $( -5.6 \pm 3.6 ) \%$. Combining Monte Carlo modelling, hardware validation, and advanced reconstruction techniques, this work establishes a path toward next-generation ktonne-scale LArTPCs as observatories for precision solar neutrino physics.

Ruiz Ferreira, Guilherme [Manchester U.] (ORCID:00↗

Aspects of clear air turbulence severity forecasting and detection

Factors influencing the accuracy of the forecasts of incidences of clear air turbulence (CAT) are discussed, along with techniques for improved verification. Descriptive ranking terms for the intensity of CAT events, ranging from light to extreme, are developed, and meteorological parameters used for predictions are reviewed, including jetstream core location, vertical and horizontal wind shears, stable layers, tropopause height, trough speed, 500-mb vorticity, surface fronts, pressure centers and cyclogenesis, and wind speeds near mountain ridges. Methods of remote detection of CAT, particularly by using radiometry sensitive to the IR water vapor band, are noted to have had some success in detecting actual CAT events and decreasing false alarms. Statistical aspects of CAT encounter severity are discussed, including the establishment of confidence intervals for thresholds of detection of CATs of varying intensities.

Ehernberger, L. J.↗

Evaporation barrier for dark matter in celestial bodies

The minimum testable dark matter (DM) mass for almost all DM signatures in celestial bodies is determined by the rate at which DM evaporates. DM evaporation has previously been calculated assuming a competition between the gravitational potential of the object, and thermal kicks from the celestial-body matter. We point out a new effect, where mediators with a range larger than the interparticle spacing induce a force proportional to the density gradient of celestial objects, forming an evaporation barrier for the DM. This effect can be so significant that evaporation does not occur even for sub-MeV DM, in stark contrast to previous calculations. This opens up a wide range of new light DM searches, many orders of magnitude in DM mass below the sensitivity of direct detection.

79 ASTRONOMY AND ASTROPHYSICS↗

A review of long drop tubes as a supplement/alternative to space experiments

A description of the 100-m drop tube at the Marshall Space Flight Center is presented, along with some undercooling observations and a discussion of some microstructural properties of deeply undercooled Nb-Ge alloys. The facility comprises two turbopumps which can evacuate the tube to 0.00001 torr, and three IR detectors at 15, 80, and 103-m levels which are sensitive to light in the range of 9660-2635 K (wavelength range of 0.2 to 1.1 microns), though recalescence events were detected at 1700 K. Finally, hypercooling regimes and maximum possible undercooling in vacuum are defined for several materials, including Al, Cu, Ni, Fe, Pt, and Nb.

Bayuzick, R. J.↗

Water Detection Based on Sky Reflections

This software has been designed to detect water bodies that are out in the open on cross-country terrain at mid- to far-range (approximately 20 100 meters), using imagery acquired from a stereo pair of color cameras mounted on a terrestrial, unmanned ground vehicle (UGV). Non-traversable water bodies, such as large puddles, ponds, and lakes, are indirectly detected by detecting reflections of the sky below the horizon in color imagery. The appearance of water bodies in color imagery largely depends on the ratio of light reflected off the water surface to the light coming out of the water body. When a water body is far away, the angle of incidence is large, and the light reflected off the water surface dominates. We have exploited this behavior to detect water bodies out in the open at mid- to far-range. When a water body is detected at far range, a UGV s path planner can begin to look for alternate routes to the goal position sooner, rather than later. As a result, detecting water hazards at far range generally reduces the time required to reach a goal position during autonomous navigation. This software implements a new water detector based on sky reflections that geometrically locates the exact pixel in the sky that is reflecting on a candidate water pixel on the ground, and predicts if the ground pixel is water based on color similarity and local terrain features

Rankin, Arturo L.↗

Developmental Hardware Testing Results and Forward Plans for the Spacecraft Water Impurity Monitor (SWIM) Organic Water Module (OWM)

We present testing results for developmental hardware of the Spacecraft Water Impurity Monitor (SWIM) Organic Water Module (OWM). SWIM-OWM will monitor spacecraft potable water and system water for trace organic contaminants. The system will detect and identify the specific organic chemical that makes up a given total organic carbon reading. We have built a first development unit (1DU) for SWIM-OWM, which directly injects aqueous water samples and detects chemicals with both a thermal conductivity detector and mass spectrometer sensor. The gas chromatography mass spectrometer (GCMS) system that comprises SWIM-OWM draws on the success of ISS-proven mass spectrometer hardware, and the demonstration of GCMS detection of trace organic contaminants in ISS cabin air. SWIM-OWM benefits from the excellent sensitivity and specificity afforded by GCMS. We have demonstrated detection of a set of chemicals relevant to both crew health and performance as well as system monitoring; these target chemicals range from light, volatile organics such as acetone and ethanol, to heavier, very non-volatile compounds such as dimethyl sulfone and o-phthalaldehyde. Direct aqueous injection was chosen for the general applicability of the technique to clean water sampling and to preclude sample pre-processing, which facilitates an on-line implementation of the SWIM-OWM when deployed in a spacecraft or habitation module. A specific advantage of direct aqueous injection when coupled with appropriate methods is that both the light, volatile organics and heavier non-volatiles can be detected from a single injection, in a single chromatogram. Results from 1DU testing will be discussed, and forward plans will be outlined for continued maturation of SWIM-OWM with the goal of implementing a technology demonstration for the purposes of maturing the engineering design and operations in an environment relevant to NASA’s future goals of exploring and setting up habitation on the Moon and Mars.

Water Monitoring↗

Developmental Hardware Testing Results and Forward Plans for Spacecraft Water Impurity Monitor (SWIM) Organic Water Module (OWM)

We present testing results for developmental hardware of the Spacecraft Water Impurity Monitor (SWIM) Organic Water Module (OWM). SWIM-OWM will monitor spacecraft potable water and system water for trace organic contaminants. The system will detect and identify the specific organic chemical that makes up a given total organic carbon reading. We have built a first development unit (1DU) for SWIM-OWM, which directly injects aqueous water samples and detects chemicals with both a thermal conductivity detector and mass spectrometer sensor. The gas chromatography mass spectrometer (GCMS) system that comprises SWIM-OWM draws on the success of ISS-proven mass spectrometer hardware, and the demonstration of GCMS detection of trace organic contaminants in ISS cabin air. SWIM-OWM benefits from the excellent sensitivity and specificity afforded by GCMS. We have demonstrated detection of a set of chemicals relevant to both crew health and performance as well as system monitoring; these target chemicals range from light, volatile organics such as acetone and ethanol, to heavier, very non-volatile compounds such as dimethyl sulfone and o-phthalaldehyde. Direct aqueous injection was chosen for the general applicability of the technique to clean water sampling and to preclude sample pre-processing, which facilitates an on-line implementation of the SWIM-OWM when deployed in a spacecraft or habitation module. A specific advantage of direct aqueous injection when coupled with appropriate methods is that both the light, volatile organics and heavier non-volatiles can be detected from a single injection, in a single chromatogram. Results from 1DU testing will be discussed, and forward plans will be outlined for continued maturation of SWIM-OWM with the goal of implementing a technology demonstration for the purposes of maturing the engineering design and operations in an environment relevant to NASA’s future goals of exploring and setting up habitation on the Moon and Mars.

Water Monitoring↗