Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “level sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

CovS inactivation reduces CovR promoter binding at diverse virulence factor encoding genes in group A Streptococcus

The control of virulence gene regulator (CovR), also called caspsule synthesis regulator (CsrR), is critical to how the major human pathogen group A Streptococcus fine-tunes virulence factor production. CovR phosphorylation (CovR~P) levels are determined by its cognate sensor kinase CovS, and functional abrogating mutations in CovS can occur in invasive GAS isolates leading to hypervirulence. Presently, the mechanism of CovR-DNA binding specificity is unclear, and the impact of CovS inactivation on global CovR binding has not been assessed. Thus, we performed CovR chromatin immunoprecipitation sequencing (ChIP-seq) analysis in the emm1 strain MGAS2221 and its CovS kinase deficient derivative strain 2221-CovS-E281A. We identified that CovR bound in the promoter regions of nearly all virulence factor encoding genes in the CovR regulon. Additionally, direct CovR binding was observed for numerous genes encoding proteins involved in amino acid metabolism, but we found limited direct CovR binding to genes encoding other transcriptional regulators. The consensus sequence AATRANAAAARVABTAAA was present in the promoters of genes directly regulated by CovR, and mutations of highly conserved positions within this motif relieved CovR repression of the hasA and MGAS2221_0187 promoters. Analysis of strain 2221-CovS-E281A revealed that binding of CovR at repressed, but not activated, promoters is highly dependent on CovR~P state. CovR repressed virulence factor encoding genes could be grouped dependent on how CovR~P dependent variation in DNA binding correlated with gene transcript levels. Taken together, the data show that CovR repression of virulence factor encoding genes is primarily direct in nature, involves binding to a newly-identified DNA binding motif, and is relieved by CovS inactivation. These data provide new mechanistic insights into one of the most important bacterial virulence regulators and allow for subsequent focused investigations into how CovR-DNA interaction at directly controlled promoters impacts GAS pathogenesis.

59 BASIC BIOLOGICAL SCIENCES↗

Detecting outliers in streaming time series data from ARM distributed sensors

The Atmospheric Radiation Measurement (ARM) Data Center at ORNL collects data from a number of permanent and mobile facilities around the globe. The data is then ingested to create high level scientific products. High frequency streaming measurements from sensors and radar instruments at ARM sites require high degree of accuracy to enable rigorous study of atmospheric processes. Outliers in collected data are common due to instrument failure or extreme weather events. Thus, it is critical to identify and flag them. We employed multiple univariate, multivariate and time series techniques for outlier detection methods and studied their effectiveness. First, we examined Pearson correlation coefficient which is used to measure the pairwise correlations between variables. Singular Spectrum Analysis (SSA) was applied to detect outliers by removing the anticipated annual and seasonal cycles from the signal to accentuate anomalies. K-means was applied for multivariate examination of data from collection of sensors to identify any deviation from expected and known patterns and identify abnormal observation. The Pearson correlation coefficient, SSA and K-means methods were later combined together in a framework to detect outliers through a range of checks. We applied the developed method to data from meteorological sensors at ARM Southern Great Plains site and validated against existing database of known data quality issues.

Lu, Yuping↗

I&C System Sensors for Advanced Nuclear Reactors

As advanced reactor designers proceed with further research, design implementation, testing, and deployment, it is now time to address their instrumentation and control (I&C) needs. First, we must identify the process variables that must be measured to control an advanced reactor and monitor its safety. As with any nuclear power plant, it is safe to assume that temperature, pressure, flow, level, and neutron flux are the predominant variables to be measured. As a second step, the range of process values must be established as well as the level of accuracy, redundancy, and speed of response of sensors that must be deployed to measure these values. The harsh environments of advanced reactors such as high temperatures, high levels of nuclear radiation, potential for corrosion, and limited access to sensors for maintenance are just a few examples of instrumentation challenges. This is compounded by the relatively small market for new sensors that must be designed, developed, and qualified for advanced reactors. That is, the cost of these activities can deter major sensor manufacturers from entering the advanced reactor market. Furthermore, the operating cycles of most advanced reactors are expected to be much longer than conventional plants adding to the need for instrumentation that can maintain calibration and response time over extended intervals. The fact that there are now a variety of advanced reactors under design and development adds to the complexity of instrumentation that may differ for various types of advanced plants. A few examples of the most commonly discussed advanced reactors are reviewed in this paper followed by a brief discussion of their instrumentation needs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A ruthenium oxide thermometer for dilution refrigerators operating down to 5 mK

At the lowest temperatures achieved in dilution refrigerators, ruthenium oxide resistance thermometers often saturate and therefore lose their sensitivity. In an effort to extend the range of such temperature sensors, we built a thermometer which maintains sensitivity to 5 mK. A key component of this thermometer is an in situ radio frequency filter which is based on a modern rf absorption material. Here, we show that the use of such a filter is only effective when it is encased in the same rf-tight enclosure as the ruthenium oxide sensor. Our design delivers an attenuation level that is necessary to mitigate the effects of parasitic heating of a fraction of pW present in our circuit. Furthermore, we show that the likely origin of this parasitic heating is the black body radiation present within the experimental space of the refrigerator. We found that the equilibration time of the thermometer increases rapidly as the temperature is lowered; below 5 mK this thermometer becomes impractical because of the prohibitively long equilibration times.

47 OTHER INSTRUMENTATION↗

A 10 nN resolution thrust-stand for micro-propulsion devices

We report on the development of a nano-Newton thrust-stand that can measure up to 100 μN thrust from different types of microthrusters with 10 nN resolution. The compact thrust-stand measures the impingement force of the particles emitted from a microthruster onto a suspended plate of size 45 mm × 45 mm and with a natural frequency over 50 Hz. Using a homodyne (lock-in) readout provides strong immunity to facility vibrations, which historically has been a major challenge for nano-Newton thrust-stands. A cold-gas thruster generating up to 50 μN thrust in air was first used to validate the thrust-stand. Better than 10 nN resolution and a minimum detectable thrust of 10 nN were achieved. Thrust from a miniature electrospray propulsion system generating up to 3 μN of thrust was measured with our thrust-stand in vacuum, and the thrust was compared with that computed from beam diagnostics, obtaining agreement within 50 nN to 150 nN. The 10 nN resolution obtained from this thrust-stand matches that from state-of-the-art nano-Newton thrust-stands, which measure thrust directly from the thruster by mounting it on a moving arm (but whose natural frequency is well below 1 Hz). The thrust-stand is the first of its kind to demonstrate less than 3 μN resolution by measuring the impingement force, making it capable of measuring thrust from different types of microthrusters, with the potential of easy upscaling for thrust measurement at much higher levels, simply by replacing the force sensor with other force sensors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Asi Nuclear Energy Sensors Data Portal Chatbot And Data Structuring Tool

The Idaho National Laboratory (INL) is advancing the development of an AI-powered chatbot and data structuring tool specifically designed to accelerate data mining processes for sensor-related information and seamlessly integrate the results into the ASI Sensors Data Portal (https://nes.energy.gov/). By doing so, the software aims to enhance the accessibility, usability, and organization of sensor data for nuclear energy applications. The software initial phase focuses on retrieving comprehensive datasets, prioritizing the past five years of publicly available information from the Office of Scientific and Technical Information (OSTI). These datasets will be meticulously processed to ensure compatibility, employing cleaning and preprocessing steps to eliminate irrelevant, incomplete, or corrupted information, thus establishing a robust foundation for subsequent AI use. The data will serve as the backbone for training an AI model and chatbot, which will act as an interactive tool enabling users to ask complex, context-specific questions and receive accurate, validated answers derived from constrained literature. In parallel, the project incorporates a data structuring process supported by AI to organize sensor information from multiple sources into a standardized format. This structured data will include detailed sensor specifications, such as measurement range, applications, accuracy, and operating conditions, generated and documented with AI. These specifications will be systematically integrated into the sensor portal. To maintain the highest levels of accuracy and relevance, all AI-generated outputs will be reviewed and validated by subject matter experts (SMEs), with additional fields or parameters added as needed. Future stages of the project aim to expand the dataset beyond OSTI to include other sources and potentially incorporate unclassified controlled information (UCI) with restricted access protocols to address security and confidentiality requirements.

Mapes, NormanJ. [Idaho National Laboratory (INL), ↗

Signal Processing of Multiplexed Optical PWM Signals for Sensor Arrays in Nuclear Environments

Safe and effective generation of terrestrial nuclear power greatly benefits from the actionable data provided by the array of sensors located throughout a plant to provide a holistic online indication of reactor operation. This array includes sensors for monitoring coolant flow and pressure, temperature and heat transfer, radiation levels, structure health monitoring, and other critical parameters for reactor operation. While sensors capable of measuring these parameters have been developed, the electronics used in the pre-amplification and analog-to-digital conversion of the small signals they produce are extremely sensitive and susceptible to damage by high-temperatures and radiation environments nuclear reactors encounter while generating power. The small signals from sensors in nuclear power plants (NPPs) are transmitted over long cable runs which introduce dispersion artifacts into the signals of interest as well as electromagnetic interference (EMI) from lighting fixtures, pumps, mains electricity, and other equipment. To overcome these challenges, a front-end digitization (FREND) platform has been developed to use radiation-tolerant electronics to multiplex, amplify, and optically encode signals from an array of sensors for transmission over an optical fiber to mitigate dispersion and EMI artifacts from long runs of electrical cabling. To recover the optically transmitted data, a signal processing scheme based on 1-dimensional template matching to an indexing channel is described herein and demonstrated to have an effective bit-depth of 9.2 bits (1%). This scheme has been validated in proof-of-concept, non-nuclear testing and preliminary experimental results show good agreement between the measured optical output and and sensor input signals. The FREND system represents a low-loss data link between sensors in nuclear environments and data acquisition hardware which is aimed at improving the signal-to-noise ratio of the data acquired from these sensors to provide better information to operators and researchers.

Sweeney, Dan↗

Survey of Neutron Flux Sensors for Monitoring Advanced Reactor Concepts Operating with Low Neutron Fluence Rate and Extended Uninterrupted Lifespans

The purpose of this report is to provide a survey of neutron sensors applicable to the low power levels (low neutron fluence rate) for reactor monitoring and controls. A survey of detectors for reactor power monitoring and controls from various commercial vendors—Reuter Stokes, Framatome, Exosens, and Mirion—is presented in the following sections based on application of reactor power ranges. Detector specifications are provided where available per each of the vendor’s catalogues and specification sheets found on their websites. While this is not an all encompassing list, it provides an example of detector options. Fission chambers and self powered neutron detectors (SPNDs) for in-core application with changes to the neutron-sensitive materials—fissile depots for fission chambers and emitters for SPNDs—for regenerative capabilities will be discussed in the latter sections.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Passive hybrid sensing tag with flexible substrate saw device

The integration of surface acoustic wave (SAW) filters, microfabricated transmission lines, and sensors onto polymer substrates in order to enable a passive wireless sensor platform is described herein. Incident microwave pulses on an integrated antenna are converted to an acoustic wave via a SAW filter and transmitted to an impedance based sensor, which for this work is a photodiode. Changes in the sensor state induce a corresponding change in the impedance of the sensor resulting in a reflectance profile. Data collected at a calibrated receiver is used to infer the state of the sensor. Based on this principal, light levels were passively and wirelessly demonstrated to be sensed at distances of up to about 12 feet.

47 OTHER INSTRUMENTATION↗

Pyroprocessing Monitoring Technology Development at Idaho National Laboratory

The Idaho National Laboratory (INL), with support from the U.S. Department of Energy, Office of Nuclear Energy, Nuclear Technology Research and Development program, has been developing advanced instrumentation and approaches for enhancing the effectiveness of nuclear material control and accounting for future reprocessing facilities with particular emphasis on pyroprocessing. Advanced modeling capabilities augment new instrumentation development, predict material flows, integrate process monitoring data, and assess overall system effectiveness of the safeguards and security system. In this paper we provide a brief overview of the Safeguards and Security by Design approach being pursued under the program and details of advanced process monitoring instrumentation under development at the INL, which includes a triple bubbler system for on-line monitoring of level and density of molten salt, sensors for monitoring actinide concentrations in molten salt, and thermal-couple instrumentation for near real time determination of Pu content in U/TRU ingots. Laboratory and field testing data will be presented, as well as integration of these sensors into a concept for utilization of process monitoring information in concert with traditional nuclear material accountancy data.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

AOI [3] High-Temperature Nano-Derived Micro-H 2 and - H 2 S Sensors

The emissions from coal-fired power plants remain a significant concern for air quality. This environmental challenge must be overcome by controlling the emission of sulfur dioxide (SO 2 ) and hydrogen sulfide (H 2 S) throughout the entire coal combustion process. One of the processes which could specifically benefit from robust, low cost, and high temperature compatible gas sensors is the coal gasification process which converts coal and/or biomass into syngas. Hydrogen (H 2 ), carbon monoxide (CO) and sulfur compounds make up 33%, 43% and 2% of syngas, respectively. Therefore, development of a high temperature (>500°C) chemical sensor for in-situ monitoring of H 2 , H 2 S and SO2 2 levels during coal gasification is strongly desired. The selective detection of SO 2 /H 2 S in the presence of H 2 , is a formidable task for a sensor designer. In order to ensure effective operation of these chemical sensors, the sensor system must inexpensively function within harsh temperature and chemical environment. Currently available sensing approaches, which are based on gas chromatography, electrochemistry, and IR-spectroscopy, do not satisfy the required cost and performance targets. This work focused on the development microsensors that can be applied to this application. In order to develop the high- temperature compatible microsensor, this work addressed various issues related to sensor stability, selectivity, and miniaturization. In the research project entitled “High-Temperature Nano-Derived Micro-H 2 and -H 2 S Sensors”, the team worked to develop micro-scale, chemical sensors and sensor arrays composed of nano-derived, metal-oxide composite materials to detect gases like H 2 , SO 2 , and H 2 S within high-temperature environments (>500°C). The research was completed in collaboration with NexTech Materials, Ltd. (Lewis Center, Ohio). NexTech assisted in the testing of the sensors in syngas with contaminate levels of H 2 S. The idea of including nanomaterials as the sensing material within resistive-type chemical sensor platforms was to increase the sensitivity (as shown for room temperature applications). Unfortunately, nanomaterials are not stable at high temperatures due to sintering and coarsening processes that are driven by their high surface to volume ratio. Therefore, new hydrogen and sulfur selective nanomaterial systems with high selectivity and stability properties in the proposed harsh environment were investigated. Different nano-morphologies of zirconate, molybdate, and tungstate compounds were investigated. The fabrication of the microsensors consisted of the deposition of the selective nanomaterial systems over metal based interconnects on an inert substrate. This work utilized the chemi-resistive (resistive- type) microsensor architecture where the chemically and structurally stable, high temperature compatible electrodes were sputtered onto a ceramic substrate. The nanomaterial sensing systems were deposited over the electrodes using a lost mold method patterned by conventional optical lithography. The microsensor configuration with optimized nanomaterial system was tested and compared to a millimeter-size sensor e outcomes of this research will contribute to the economical application of sensor arrays for simultaneous sensing of H 2 , H 2 S, and SO 2 .

47 OTHER INSTRUMENTATION↗

EC MoDeRn Project: In-situ Demonstration of Innovative Monitoring Technologies for Geological Disposal - 12053

Monitoring to provide information on the evolution of geological disposal presents several challenges. The 4-year, euros M 5, EC MoDeRn Project (http://www.modern-fp7.eu/), which commenced in 2009, addresses monitoring processes, state-of-the-art technology and innovative research and development of monitoring techniques. This paper discusses some of the key drivers for the development of innovative monitoring techniques and provides outlines of the demonstration programmes being conducted within MoDeRn. The aim is to develop these innovative monitoring techniques and to demonstrate them under realistic conditions present in underground laboratories. These demonstration projects, applying a range of different monitoring techniques, are being carried out at underground research facilities in different geological environments at HADES URL in Belgium (plastic clay), Bure in France (indurated clay) and at Grimsel Test Site (granite) in Switzerland. These are either built upon existing infrastructure (EC ESDRED Low pH shotcrete and TEM experiments at Grimsel; and PRACLAY experiment and underground galleries in HADES) or will be attached to infrastructure that is being developed and financed by resources outside of this project (mock-up disposal cell in Bure). At Grimsel Test Site, cross-hole and hole-to-tunnel seismic methods are being employed as a means to monitor induced changes in an artificially saturated bentonite wall confined behind a shotcrete plug. Recognising the limitations for travel-time tomography for monitoring a disposal cell, full waveform inversion techniques are being employed to enhance the capacity to monitor remote from the excavation. At the same Grimsel location, an investigation will be conducted of the potential for using a high frequency wireless (HFW) sensor network embedded within the barrier system; this will include the possibility of providing energy remotely to isolated sensors. At the HADES URL, the monitoring programme will utilise the PRACLAY gallery equipped to simulate a disposal gallery for heat-generating high-level waste evaluating fibre-optic based sensing techniques, including distributed sensing for thermal distribution and long-term reliability in harsh conditions. It also includes the potential to improve the treatment of signals from micro-seismic monitoring to enable enhanced understanding of the evolution around the gallery following its excavation due to ventilation, saturation and heating, and to image a water-bearing concretion layer. HADES URL will also be used to test wireless techniques to transmit monitoring data from the underground to the surface. The main focus of this contribution is to evaluate magneto-inductive data transmission; and to optimise energy usage. At the Bure underground facility in France, monitoring systems have been developed and will be embedded into the steel liner for the mock-up high-level waste disposal tunnel. The aim of this programme is to establish the capacity to conduct integrated monitoring activities inside the disposal cell, on the cell liner and in the near-field and to assess the capability of the monitoring to withstand construction and liner emplacement procedures. These projects, which are supported by focused development and testing of the monitoring systems, will allow the testing of both the effectiveness of these techniques applied to disposal situations and to understand the limits of these monitoring technologies. This approach should also enhance the confidence of key stakeholders in the ability to understand/confirm the changes occurring within a disposal cell. In addition, remote or 'non-intrusive' monitoring technologies are evaluated to provide a means of enhancing understanding of what is occurring in an isolated disposal cell. The projects also test solutions for embedded monitoring systems in challenging (risk of damage) situations. The outputs from this work will lead to improved understanding of these state-of-the-art techniques and allow focused development of those techniques beneficial to future monitoring programmes. It is also planned, as part of the MoDeRn programme of stakeholder engagement to show some of these monitoring demonstrations to lay stakeholders in order to receive their feed-back on the approach taken and their views on the value of this work. This feedback will help improve our understanding of how this work and future work on monitoring can be more effectively communicated. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Experimental studies in magnetically induced transverse force-frequency effect in thin quartz microresonators

In this work, the transverse force-frequency sensitivity of magnetostrictive Metglas{sup ®} (Fe{sub 85}B{sub 5}Si{sub 10}) thin film coated AT-cut thickness shear mode quartz thin plate microresonator (500 μm × 500 μm × 19 μm) is experimentally measured and modeled in Lagrangian formulation by coupling magnetostrictive deformation equations with the basic plate equations from the theory of small deformation. The quartz plate resonator is fabricated by micromachining techniques and released into fixed-free structure using focused ion beam milling. Application of a magnetic field results in the out-of-plane bending of the structure due to elastic coupling between the magnetostrictive Metglas{sup ®} and quartz resonator layers. As a result of the transverse loading and out-of-plane bending, the admittance characteristics of the resonator shifts, and these shifts are recorded in real time utilizing a network analyzer. The sensitivity is experimentally measured to be 162.3 mdeg/Oe for phase, corresponding to a frequency sensitivity of Δf/H = 11 Hz/Oe. The equivalent force-frequency sensitivity can then be calculated as 2.36 μN/Hz using the developed model. The coupled domain analysis fits well with the experimental data. Further reduction of quartz thickness and optimization of the thickness ratio of the magnetostrictive to quartz layers offers the possibility of exploiting the stress sensitivity of plate microresonators as sensitive magnetic field sensors capable of low nanoTesla to picoTesla level magnetic flux densities.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Temporal Study 2021-2022: Sensor-Based Time Series of Surface Water Temperature, Specific Conductance, Total Dissolved Solids, Turbidity, pH, and Dissolved Oxygen from across Multiple Watersheds in the Yakima River Basin in Washington, USA (v2)

This dataset supports a broader study examining the drivers of temporal variability in sediment respiration rates in the Yakima River Basin. The dataset provides periodic (weekly or biweekly) in situ hydrological and water chemistry sensor data, handheld sensor water chemistry data, general environmental context photos, and field metadata collected at six sites within multiple rivers in the Yakima River Basin in Washington, USA. In addition to the sensor data, there are plots of continuous in situ sensor data and R scripts used to generate the plots. Related sample-based water chemistry data are published separately at https://data.ess-dive.lbl.gov/datasets/doi:10.15485/1898912.The data package was originally published in September 2022. It was updated in June 2025 (v2; modified files). See the change history section in the readme for more details. For details on how to navigate data packages generated by this project, see https://data.ess-dive.lbl.gov/portals/PNNLRiverCorridorSFA/About. This dataset is comprised of one main data folder containing two sensor-specific subfolders, and one photographs folder. The main data folder includes file-level metadata (flmd), data dictionary (dd), installation methods, field metadata, handheld sensor data, field data collection protocols, international generic sample number (IGSN) mapping file, and a readme file. Each sensor subfolder (BarotrollAtm and MantaRiverData) contains a subfolder containing sensor timeseries data and plots. The BarotrollAtm Data subfolder contains In Situ Rugged BaroTROLL sensor pressure and air temperature data. The MantaRiverData subfolder contains Eureka Manta+ 35B multisonde temperature, specific conductance, and turbidity. The FieldPhotos folder contains environmental context photographs and videos. All files are .csv, .pdf, .R, .jpg, .jpeg, .heic, .mov, or .mp4.

54 ENVIRONMENTAL SCIENCES↗

Wearable sweat sensors

© 2018 Macmillan Publishers Limited, Part of Springer Nature. All Rights Reserved. Sweat potentially contains a wealth of physiologically relevant information, but has traditionally been an underutilized resource for non-invasive health monitoring. Recent advances in wearable sweat sensors have overcome many of the historic drawbacks of sweat sensing and such sensors now offer methods of gleaning molecular-level insight into the dynamics of our bodies. Here we review key developments in sweat sensing technology. We highlight the potential value of sweat-based wearable sensors, examine state-of-The-Art devices and the requirements of the underlying components, and consider ways to tackle data integrity issues within these systems. We also discuss challenges and opportunities for wearable sweat sensors in the development of personalized healthcare.

Bariya, M↗

Structural determination of Enzyme-Graphene Nanocomposite Sensor Material

State-of-the-art ultra-sensitive blood glucose-monitoring biosensors, based on glucose oxidase (GOx) covalently linked to a single layer graphene (SLG), will be a valuable next generation diagnostic tool for personal glycemic level management. We report here our observations of sensor matrix structure obtained using a multi-physics approach towards analysis of small-angle neutron scattering (SANS) on graphene-based biosensor functionalized with GOx under different pH conditions for various hierarchical GOx assemblies within SLG. We developed a methodology to separately extract the average shape of GOx molecules within the hierarchical assemblies. The modeling is able to resolve differences in the average GOx dimer structure and shows that treatment under different pH conditions lead to differences within the GOx at the dimer contact region with SLG. The coupling of different analysis methods and modeling approaches we developed in this study provides a universal approach to obtain detailed structural quantifications, for establishing robust structure-property relationships. This is an essential step to obtain an insight into the structure and function of the GOx-SLG interface for optimizing sensor performance.

59 BASIC BIOLOGICAL SCIENCES↗

Assessment of the Impact of Realistic Sensor Physics and the Integration of Ex-Core Sensors on Reactor Power Synthesis

In the work documented in this report, a weighting function–based core power synthesis method was applied to multiple Monte Carlo N-Particle (MCNP) reactor models, which are informed based on simulated self-powered neutron detector (SPND) responses. The weighting function method used has been coined the point-based iterative (PBI) method. The goal of this application is to assess the impact of considering realistic sensor physics in the generation of the simulated SPND outputs as well as to consider how the synthesis is impacted based on the inclusion of ex-core detectors in the model. The NuScale small modular reactor (SMR) and Westinghouse AP1000 pressurized water reactor (PWR) are the models that served as the testbeds for the assessment of realistic sensor physics; this was achieved by using Geant4 SPND models in comparison with analytical models, such that the effect of electron transport in realistic SPND geometries in the Geant4 model can be understood in terms of synthesis error and convergence time. The comparison was considered for fuel burnup–induced perturbations, for a range of sensor string densities and synthesized power distribution axial fidelities. The Texas A&M Testing, Research, Isotopes, General Atomics Reactor (TAMU TRIGA) reactor MCNP model was used to assess the impact of ex-core sensors; this was done by performing synthesis with and without the ex-core detectors and by quantifying the synthesis error and number of iterations associated with Gaussian-type perturbations in many locations in the core. The TAMU TRIGA model was particularly pertinent for this study because of the interest in future experimental tests with SPNDs in this reactor, as well as the ease of modifying the MCNP model to include ex-core detectors with heterogeneously described response functions. Results from the comparison between the Geant4 and analytical SPND models indicate that similar average and maximum synthesis errors were obtained for burnup-induced perturbations in both the NuScale SMR and the AP1000. This was true for a range of sensor string densities and axial fidelities. However, there were marked differences between both the Geant4 and analytically informed models in terms of the iterations required to converge on the synthesized power distribution. Namely, the Geant4-informed models tended to lead to fewer iterations, except for a few sensor–core configurations that had particularly numerous iterations. Results from the ex-core sensor assessment with the TAMU TRIGA model indicate that the inclusion of ex-core sensors drastically reduces the synthesis error of Gaussian-type perturbations close to the edge of the core, and it slightly reduces synthesis errors for perturbations closer to the center of the core. This was achieved with a minimal increase in computational cost—that is, the number of iterations required for convergence. The errors were identified to be in the same location as the perturbation in the core, indicating that the methodology remains robust for unperturbed regions of the core. A secondary result from this study with the TAMU TRIGA was yielded by analysis of the neutron flux levels in the in-core and ex-core sensor locations of the core; these flux levels indicate that SPNDs could be used as both in-core and ex-core sensors, so long as the emitter material is sensitive to thermal neutrons. The results from these studies provide a quantitative understanding of the importance of considering realistic sensor physics and including ex-core sensors to perform accurate and timely power distribution synthesis of a reactor core.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗