Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “laser interference”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Saturated laser fluorescence in turbulent sooting flames at high pressure

The primary objective was to develop a quantitative, single pulse, laser-saturated fluorescence (LSF) technique for measurement of radical species concentrations in practical flames. The species of immediate interest was the hydroxyl radical. Measurements were made in both turbulent premixed diffusion flames at pressures between 1 and 20 atm. Interferences from Mie scattering were assessed by doping with particles or by controlling soot loading through variation of equivalence ratio and fuel type. The efficacy of the LSF method at high pressure was addressed by comparing fluorescence and adsorption measurements in a premixed, laminar flat flame at 1-20 atm. Signal-averaging over many laser shots is sufficient to determine the local concentration of radical species in laminar flames. However, for turbulent flames, single pulse measurements are more appropriate since a statistically significant number of laser pulses is needed to determine the probability function (PDF). PDFs can be analyzed to give true average properties and true local kinetics in turbulent, chemically reactive flows.

King, G. B.↗

Optical Link For Readout From Focal-Plane Array

Outputs of photodetectors modulate beam of light. Proposed optical link carries analog readout signals from photodetectors in focal-plane array to external signal-processing circuitry. Insensitive to electromagnetic interference at suboptical frequencies, and imposes smaller heat load on cryogenic apparatus because it does not include high-power electronic amplifier or laser transmitter within cold chamber.

Fossum, Eric R.↗

A range-resolved bistatic lidar using a high-sensitive CCD-camera

Until now monostatic type lidar systems have been mainly utilized in the field of lidar measurements of the atmosphere. We propose here a range-resolved bistatic lidar system using a high-sensitive cooled charge coupled device (CCD) camera. This system has the ability to measure the three dimensional distributions of aerosol, atmospheric density, and cloud by processing the image data of the laser beam trajectory obtained by a CCD camera. Also, this lidar system has a feature that allows dual utilization of continuous wave (CW) lasers and pulse lasers. The scheme of measurement with this bistatic lidar is shown. A laser beam is emitted vertically and the image of its trajectory is taken with a remote high-sensitive CCD detector using an interference filter and a camera lens. The specifications of the bistatic lidar system used in the experiments are shown. The preliminary experimental results of our range-resolved bistatic lidar system suggest potential applications in the field of lidar measurements of the atmosphere.

Yamaguchi, K.↗

A Fiber-Optic Coupled Telescope for Water Vapor DIAL Receivers

A fiber-optic coupled telescope of low complexity was constructed and tested. The major loss mechanisms of the optical system have been characterized. Light collected by the receiver mirror is focused onto an optical fiber, and the output of the fiber is filtered by an interference filter and then focused onto an APD detector. This system was used in lidar field measurements with a 532-nm Nd:YAG laser beam. The results were encouraging. A numerical model used for calculation of the expected return signal agreed with the lidar return signal obtained. The assembled system was easy to align and operate and weighed about 8 kg for a 30 cm (12") mirror system. This weight is low enough to allow mounting of the fiber-optic telescope receiver system in a UAV. Furthermore, the good agreement between the numerical lidar model and the performance of the actual receiver system, suggests that this model may be used for estimation of the performance of this and other lidar systems in the future. Such telescopes are relatively easy to construct and align. The fiber optic cable allows easy placement of the optical detector in any position. These telescope systems should find widespread use in aircraft and space home DIAL water vapor receiver systems.

DeYoung, Russell J.↗

Frame-Transfer Gating Raman Spectroscopy for Time-Resolved Multiscalar Combustion Diagnostics

Accurate experimental measurement of spatially and temporally resolved variations in chemical composition (species concentrations) and temperature in turbulent flames is vital for characterizing the complex phenomena occurring in most practical combustion systems. These diagnostic measurements are called multiscalar because they are capable of acquiring multiple scalar quantities simultaneously. Multiscalar diagnostics also play a critical role in the area of computational code validation. In order to improve the design of combustion devices, computational codes for modeling turbulent combustion are often used to speed up and optimize the development process. The experimental validation of these codes is a critical step in accepting their predictions for engine performance in the absence of cost-prohibitive testing. One of the most critical aspects of setting up a time-resolved stimulated Raman scattering (SRS) diagnostic system is the temporal optical gating scheme. A short optical gate is necessary in order for weak SRS signals to be detected with a good signal- to-noise ratio (SNR) in the presence of strong background optical emissions. This time-synchronized optical gating is a classical problem even to other spectroscopic techniques such as laser-induced fluorescence (LIF) or laser-induced breakdown spectroscopy (LIBS). Traditionally, experimenters have had basically two options for gating: (1) an electronic means of gating using an image intensifier before the charge-coupled-device (CCD), or (2) a mechanical optical shutter (a rotary chopper/mechanical shutter combination). A new diagnostic technology has been developed at the NASA Glenn Research Center that utilizes a frame-transfer CCD sensor, in conjunction with a pulsed laser and multiplex optical fiber collection, to realize time-resolved Raman spectroscopy of turbulent flames that is free from optical background noise (interference). The technology permits not only shorter temporal optical gating (down to <1 s, in principle), but also higher optical throughput, thus resulting in a substantial increase in measurement SNR.

Nguyen, Quang-Viet↗

In situ detection of tropospheric OH, HO2, NO2, and NO by laser-induced fluorescence in detection chambers at reduced pressures

For detection of OH and HO2, we have met or exceeded most of the goals of the proposal for this grant. We have succeeded in building a prototype instrument for the detection of OH and HO2 that has a detection sensitivity of about 2 x 10 exp 4 (OH molecules/cc)/(ct/s), about five times greater than proposed. The current minimum detectable OH of 1.4 x 10 exp 5 OH molecules/cc (S/N=2; 30 second integration) is less than half that proposed, and will be much lower once scattered light levels are reduced. The instrument displays other important properties. First, interfering signals from other gases and OH losses on the inlet appear to be small under laboratory and field conditions. Second, three different calibration methods, two external to the inlet, give similar results, to within 30 percent. Third, the chemical conversion efficiency of HO2 to OH by addition of reagent NO is better than 90 percent. All of these factors give us great confidence that this technique works. The instrument has gone through several variations that have not affected its potential performance but have affected its use. We were able to undergo the first field trials away from State College in June 1992, when we were able to participate informally in the ROSE experiment in rural Alabama, a year ahead of the proposed schedule for field studies. Because this field experiment was our first and the data analysis was complicated by instrument instabilities, we have not yet released the observations. None-the-less, we have gained insight into instrument design. We have not yet completed all of the proposed work. The calibration systems need to be improved to reduce the 50 percent to 100 percent uncertainties to less than 30 percent. Interference signals from ambient gases and possible losses on the inlet under field conditions need to be quantified. Finally, the detection of NO2 and NO with laser induced fluorescence is only now being seriously pursued.

Brune, William H.↗

Laser heating of ferroelectric cubes for tunable electromagnetic properties in metamaterials

In this experimental study, we demonstrate the feasibility of a thermally tunable, resonant dielectric microwave metasurface based on sub-wavelength Mie resonances of ferroelectric dielectric cubes (Calcium titanate, CaTiO 3 ) in which the temperature of the meta-atoms can be locally and dynamically controlled by heating with an optical laser beam over a large range of temperatures and, consequently, values of the dielectric constant of the cube and corresponding resonance frequency of the meta-atoms. Further, this avoids any interference of otherwise necessary heating elements or power supply wires with the propagation of the microwave signal and can be made spatially addressable. The concept scales at least to the THz domain. This contactless approach opens up an alternative avenue to tunability and active control of metamaterials.

36 MATERIALS SCIENCE↗

Magnetic functionalization and catalytic behavior of magnetic nanoparticles during laser photochemical graphitization of polyimide

We report laser-assisted photochemical graphitization of polyimides (PIs) into functional magnetic nanocomposites using laser irradiation of PI in the presence of magnetite nanoparticles (MNPs). PI Kapton sheets covered with MNP were photochemically treated under ambient conditions using a picosecond pulsed laser (1064 nm) to obtain an electrically conductive material. Scanning electron microscopy of the treated material revealed a layered magnetic nanoparticle/graphite (MNP/graphite) nanocomposite structure. Four probe conductivity measurements indicated that the nanocomposite has an electrical conductivity of 1550 ± 60 S/m. Superconducting quantum interference device magnetometer-based magnetic characterization of the treated material revealed an anisotropic ferromagnetic response in the MNP/graphite nanocomposite compared to the isotropic response of MNP. Raman spectroscopy of the MNP/graphite nanocomposite revealed a fourfold improvement in graphitization, suppression in disorder, and decreased nitrogenous impurities compared to the graphitic material obtained from laser treatment of just PI sheets. X-ray photoelectron spectroscopy, x-ray diffraction, and energy-dispersive x-ray spectroscopy were used to delineate the phase transformations of MNP during the formation of MNP/graphite nanocomposite. Post-mortem characterization indicates a possible photocatalytic effect of MNP during MNP/graphite nanocomposite formation. Under laser irradiation, MNP transformed from the initial Fe 3 O 4 phase to γ-Fe 2 O 3 and Fe 5 C 2 phases and acted as nucleation spots to catalyze the graphitization process of PI.

36 MATERIALS SCIENCE↗

GEOS-1 laser pulse return shape analysis

An attempt has been made to predict the shape of the laser return pulse from the corner cube retroreflectors on the GEOS-1 spacecraft. The study is geometrical only, and neglects factors such as optical interference, atmospheric perturbations, etc. A function giving the intensity of the return signal at any given time has been derived. In addition, figures are given which show the predicted return pulse shape as a function of time, the angle between the beam and the spin axis, and an in-plane angle (designating the orientation of the intersection of the planar waves with the plane of the corner cubes).

Felsentreger, T. L.↗

Holographic flow visualization of time-varying shock waves

Rapid-double-exposure, diffuse-illumination holography is evaluated analytically and experimentally as a flow visualization method for time-varying shock waves. Conditions are determined that minimize the distance (localization error) between the surface or curve of interference-fringe localization and the shock surface. Treated specifically are the cases of shock waves in a transonic compressor rotor for which there is laser anemometer data for comparison and shock waves in a flutter cascade.

Decker, A. J.↗

Raman scattering measurements in flames using a tunable KrF excimer laser

A narrow-band tunable KrF excimer laser is used as a spontaneous vibrational Raman scattering source to demonstrate that single-pulse concentration and temperature measurements, with only minimal fluorescence interference, are possible for all major species (O2, N2, H2O, and H2) at all stoichiometries (fuel-lean to fuel rich) of H2-air flames. Photon-statistics-limited precisions in these instantaneous and spatially resolved single-pulse measurements are typically 5 percent, which are based on the relative standard deviations of single-pulse probability distributions. In addition to the single-pulse N2 Stokes/anti-Stokes ratio temperature measurement technique, a time-averaged temperature measurement technique is presented that matches the N2 Stokes Raman spectrum to theoretical spectra by using a single intermediate state frequency to account for near-resonance enhancement. Raman flame spectra in CH4-air flames are presented that have good signal-to-noise characteristics and show promise for single-pulse UV Raman measurements in hydrocarbon flames.

Wehrmeyer, Joseph A.↗

Designing high-power, octave spanning entangled photon sources for quantum spectroscopy

Entangled photon spectroscopy is a nascent field that has important implications for measurement and imaging across chemical, biology, and materials fields. Entangled photon spectroscopy potentially offers improved spatial and temporal-frequency resolutions, increased cross sections for multiphoton and nonlinear measurements, and new abilities in inducing or measuring quantum correlations. A critical step in enabling entangled photon spectroscopies is the creation of high-flux entangled sources that can use conventional detectors as well as provide redundancy for the losses in realistic samples. Here, we report a periodically poled, chirped, lithium tantalate platform that generates entangled photon pairs with ~10 -7 efficiency. For a near watt level diode laser, this results in a near μW-level flux. The single photon per mode limit that is necessary to maintain non-classical photon behavior is still satisfied by distributing this power over up to an octave-spanning bandwidth. The spectral–temporal photon correlations are observed via a Michelson-type interferometer that measures the broadband Hong–Ou–Mandel two-photon interference. A coherence time of 245 fs for a 10 nm bandwidth in the collinear case and a coherence time of 62 fs for a 125 nm bandwidth in the non-collinear case are measured using a CW pump laser and, essentially, collecting the full photon cone. We outline in detail the numerical methods used for designing and tailoring the entangled photons source, such as changing center wavelength or bandwidth, with the ultimate aim of increasing the availability of high-flux UV–Vis entangled photon sources in the optical spectroscopy community.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

TOFHunter—unlocking rapid untargeted screening of inductively coupled plasma–time-of-flight–mass spectrometry data

This study provides an overview of a newly developed open source program written in Python, TOFHunter, which permits the rapid and untargeted screening of inductively coupled plasma (ICP)-time-of-flight (TOF)-mass spectrometry (MS) datasets. ICP-TOF-MS is an analytical tool capable of providing quasi simultaneous detection of all nuclides from Li to Pu. This capability has triggered an increase in studies investigating single-particle analysis in which the TOF-MS provides correlated elemental/isotopic signatures on a particle basis in time. Similarly, laser ablation mapping has seen rapid growth owing to ICP-TOF-MS's capacity to handle fast washout times (<10 ms) while providing a broad nuclide coverage. The caveat to this broad mass coverage and high time resolution comes in the form of large, overwhelming datasets. With datasets typically on the scale of gigabytes, it is easy for a user to only focus on very targeted analytes; however, this focus diminishes the opportunity offered by the TOF-MS detector. TOFHunter applies chemometric methods, principal component analysis (PCA), and interesting features finder (IFF) on ICP-TOF-MS data, allowing for investigation of correlations, major and minor variance sources, and sample screening. The unique spectra identified by the (IFF) are used to generate a list of mass peaks, which are then matched with both nuclides and potential interferences before being exported for the user to investigate. Several case studies are discussed herein, demonstrating TOFHunter's ability to screen aqueous injections, single-particle/single-cell analysis, and probe laser ablation mapping files for unique regions of interest.

47 OTHER INSTRUMENTATION↗

Broadband rapid-scanning phase-modulated Fourier transform electronic spectroscopy

We present a phase-modulated approach for ultrabroadband Fourier transform electronic spectroscopy. To overcome the bandwidth limitations and spatial chirp introduced by acousto-optic modulators (AOMs), pulses from a 1 µm laser are modulated using AOMs prior to continuum generation. This phase modulation is transferred to the continuum generated in a yttrium aluminum garnet crystal. Separately generated phase-modulated continua in two arms of a Mach-Zehnder interferometer interfere with the difference of their modulation frequencies, enabling physical under-sampling of the signal and the suppression of low-frequency noise. By interferometrically tracking the relative time delay of the continua, we perform continuous, rapid-scanning Fourier transform electronic spectroscopy with a high signal-to-noise ratio and spectral resolution. As proof of principle, we measure the linear absorption and fluorescence excitation spectra of a laser dye and various biological samples.

Javed, Ariba↗

Overview of the LANL Multi-Probe Radiography Project [Slides]

Future radiographic facilities for the U.S. defense program will be required to provide more information as simulation codes improve in both physics’ fidelity and resolution. A possible approach is to use more types of probe beams in addition to, or instead of X-rays, generated by 20-MeV electron accelerators from a small number of directions. High power short-pulse laser systems can generate beams of protons, neutrons and electrons, as well as X-rays. The cost of these systems is falling rapidly. So, it can be imagined that deploying multiple short-pulse lasers along with other, more traditional probes, will become feasible. In this project, we are following three paths to determine if such an approach will succeed for cm-scale objects. The first is an experimental one to determine if the presence of multiple short-pulse probes cause interference with each other, especially while radiographing dynamic objects. The second leg of this project is to determine if having multiple types of probes really does give more information on composition. Finally, an overall assessment of the viability of this approach will be made. Examples from recent experiments at the Omega EP laser will be presented. The initial approach to evaluating radiographs with multiple probes using the Bayesian Inference Engine (BIE) also will be given.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electron-Nanobunch-Width-Dominated Spectral Power Law for Relativistic Harmonic Generation from Ultrathin Foils

Relativistic high-order harmonic generation from solid-density plasma offers a compact source of coherent ultraviolet and x-ray light. For solid targets much thinner than the laser wavelength, the plasma thickness can be tuned to increase conversion efficiency; a reduction in total charge allows for balancing the laser and plasma driving forces, producing the most effective interaction. Unlike for semi-infinite plasma surfaces, in this study we find that for ultrathin foil targets the dominant factor in the emission spectral shape is the finite width of the electron nanobunches, leading to a power-law exponent of approximately 10/3. Ultrathin foils produce higher-efficiency frequency conversion than solid targets for moderately relativistic (1 0 <40) interactions and also provide unique insight into how the trajectories of individual electrons combine and interfere to generate reflected attosecond pulses.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Lidar Technology at the Goddard Laser and Electro-Optics Branch

The Laser and Electro-Optics Branch at Goddard Space flight Center was established about three years ago to provide a focused center of engineering support and technology development in these disciplines with an emphasis on spaced based instruments for Earth and Space Science. The Branch has approximately 15 engineers and technicians with backgrounds in physics, optics, and electrical engineering. Members of the Branch are currently supporting a number of space based lidar efforts as well as several technology efforts aimed at enabling future missions. The largest effort within the Branch is support of the Ice, Cloud, and land Elevation Satellite (ICESAT) carrying the Geoscience Laser Altimeter System (GLAS) instrument. The ICESAT/GLAS primary science objectives are: 1) To determine the mass balance of the polar ice sheets and their contributions to global sea level change; and 2) To obtain essential data for prediction of future changes in ice volume and sea-level. The secondary science objectives are: 1) To measure cloud heights and the vertical structure of clouds and aerosols in the atmosphere; 2) To map the topography of land surfaces; and 3) To measure roughness, reflectivity, vegetation heights, snow-cover, and sea-ice surface characteristics. Our efforts have concentrated on the GLAS receiver component development, the Laser Reference Sensor for the Stellar Reference System, the GLAS fiber optics subsystems, and the prelaunch calibration facilities. We will report on our efforts in the development of the space qualified interference filter [Allan], etalon filter, photon counting detectors, etalor/laser tracking system, and instrument fiber optics, as well as specification and selection of the star tracker and development of the calibration test bed. We are also engaged in development work on lidar sounders for chemical species. We are developing new lidar technology to enable a new class of miniature lidar instruments that are compatible with small Discovery-class orbiters now in the NASA planetary program. The purpose of the lidar is to continuously profile the water vapor and dust in the Mars atmosphere from orbit in order to quantify its dynamics, their relationship in the diurnal cycles, and to infer water vapor exchange with the Mars surface. To remotely measure the water-vapor height profiles, we will use the differential absorption lidar (DIAL) technique. We are also developing a laser sensor for measuring the total column content of CO2 in the atmosphere of the earth. CO2 is the principal greenhouse gas and has increased by roughly 80 ppm in the last century and a half. We will report our efforts in the development of the laser transmitter and photon counting detector components for a Mars Orbiting DIAL system and for the CO2 sounder.

Heaps, William S.↗

Online Rapid Analysis of Laser Heterodyne Radiometer (LHR) Data Using the Planetary Spectrum Generator (PSG)

One of the biggest challenges in developing scientific instruments is not just the build and testing of an instrument, but the method for processing the data and producing a consistent, well characterized data product that can be confidently used by the public and scientific community. Raw data products are frequently an array of numbers that are a read-out of voltages. The challenge is to convert these arrays into meaningful information as well as remove noise and interferences. Because this can be a tedious and time-consuming, the goal is to automate the process so that data ca be processed rapidly and be available in real-time for event monitoring. Here we present a rapid analysis method for Laser Heterodyne Radiometer (LHR) data that can be used to analyze data taken from a range of LHR observation modes (column, limb, etc.). This online tool uses the versatile Planetary Spectrum Generator (PSG) and allows LHR users to quickly analyze their own data using a NASA Goddard Space Flight Center (GSFC) monitored capability to ensure quality and reproducibility in the data products. Background: Development of a miniaturized LHR (mini-LHR) as a ground instrument for measuring carbon dioxide (CO 2 ) and methane (CH 4 ) in the atmospheric column started in 2009 with the commercial availability of distributive feedback lasers (DFB) in wavelengths that could measure absorption of gases in the near-IR. As new DFB lasers, detectors and hardware emerged at different wavelengths, additional gases were added to the capability. The mini-LHR was adapted into an occultation-viewing CubeSat with Lawrence Livermore National Laboratory (LLNL) for observing CO 2 , CH 4 , and H 2 O in the limb and was launched in 2019. Other versions of the LHR technology have been designed for observation of water vapor in the lunar exosphere as well as observations of trace gases in planetary atmospheres and plumes from icy moons. The PSG is an online tool developed at GSFC that can be used for synthesizing Earth and planetary spectra (atmospheres and surfaces) over a broad range of wavelengths (0.1 μm to 100 mm) for any observatory, orbiter or lander. Spectra are simulated by combining several state-of-the-art radiative transfer models, spectroscopic databases, planetary databases, as well as modern-era retrospective analysis for research and applications, version 2 (MERRA-2) data set which provides meteorological inputs such as modeled surface pressure for calculating dry-air columns.

Emily Wilson↗