Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “isotope separation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Measurement of Plutonium Ratios for CRM 137A Recertification

This report documents the analytical methodologies used by the Chemical and Isotopics Mass Spectrometry (CIMS) Group at the US Department of Energy’s Oak Ridge National Laboratory (ORNL) for plutonium isotopic ratio characterizations on purified ~1 mg units prepared by Lawrence Livermore National Laboratory (LLNL) from a mother solution created from an existing 250 mg unit of certified reference material (CRM) 137. The analytical processes described are designed to maintain traceability of the final certified attributes and to eliminate sources of systematic bias for the measurements described. The measurands for certification are the plutonium isotope ratios: 238 Pu/ 239 Pu, 240 Pu/ 239 Pu, 241 Pu/ 239 Pu, and 242 Pu/ 239 Pu. The preparation and analytical process included the following activities: Preparation of reference materials to be used as calibrants to establish traceability to the SI unit of mass for the isotopic analyses and quality controls. For the plutonium isotopic analyses, CRM 128 (a CRM comprising equal atoms of 239 Pu and 242 Pu) was used as the primary calibrant; Each CRM 137A unit was reconstituted using dilute high-purity HNO3. From each, seven replicates were distributed for the isotopic characterizations by thermal ionization mass spectrometry (TIMS) using the total evaporation (TE) method for isotope ratio measurements and MC-ICP-MS using a dynamic peak hooping method for secondary isotope ratio measurements; Due to time delay in the analyses from the last purification of the original CRM 137 mother solution by LLNL, an aliquot of the three provided plutonium units was purified using Eichrom TEVA separation methods to remove americium in-growth and uranium impurities; Minimally corrected data were reported from each analysis using reporting templates provided by the New Brunswick Laboratory Program Office (NBL PO) for the specific methods used for isotopic measurements. In addition, a copy of the instrument exports, Excel templates for isotopic data corrections, and the uncertainty budgets completed with the GUM Workbench software package were submitted to NBL PO.

07 ISOTOPE AND RADIATION SOURCES↗

NorthStar Helium Cooling System. Final Report on LANL Contribution

From the beginning of NNSA support to the NorthStar development of a production facility for the medical isotope Molybdenum-99 (Mo99), LANL has been responsible for the design and testing of a target and its cooling. The target is comprised of a stack of Mo100 disks separated by coolant flow gaps between the disks and between the first disk and a housing window, which separates the target and its coolant from the vacuum of the beam line. The target, and therefore its cooling requirements, evolved steadily over the years of system development

07 ISOTOPE AND RADIATION SOURCES↗

Development of Nontargeted Workflow of Occupational Exposure by Infrared Ion Spectroscopy and Silicone Wristbands’ Passive Sampling

Monitoring chemical exposure has well-established protocols and procedures for occupational health and industrial hygiene across various career fields and in a variety of occupational and environmental conditions. Iterative analytical development has led to validated methods to provide employers and employees with safe working conditions in terms of industrial hygiene. These validated methods are commonly supported by commercial laboratories. Here, this workflow is explicitly a targeted approach in which sampling media, sample preparation, chemical separation, quantitative target detection, and post processing are well established. This workflow also relies on commercially available chemical surrogates, isotopically labeled internal standards, and certified/standard reference materials from reputable vendors. An untargeted workflow lacks many key ingredients of validated analytical methods to include the known chemical target.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Imaging and dosimetric characteristics of 67 Cu

In recent years the use of beta-emitting radiopharmaceuticals for cancer therapy has expanded rapidly following development of therapeutics for neuroendocrine tumors, prostate cancer, and other oncologic malignancies. One emerging beta-emitting radioisotope of interest for therapy is 67 Cu (t 1/2 : 2.6 d) due to its chemical equivalency with the widely-established positron-emitting isotope 64 Cu (t 1/2 : 12.7 h). Here we evaluate both the imaging and dosimetric characteristics of 67 Cu, as well as producing the first report of SPECT/CT imaging using 67 Cu. To this end, 67 Cu was produced by photon-induced reactions on isotopically-enriched 68 Zn at the Low-Energy Accelerator Facility (LEAF) of Argonne National Laboratory, followed by bulk separation of metallic 68 Zn by sublimation and radiochemical purification by column chromatography. Gamma spectrometry was performed by efficiency-calibrated high-purity germanium (HPGe) analysis to verify absolute activity calibration and establish radionuclidic purity. Absolute activity measurements corroborated manufacturer-recommended dose-calibrator settings and no radionuclidic impurities were observed. Using the Clinical Trials Network anthropomorphic chest phantom, SPECT/CT images were acquired. Medium Energy (ME) SPECT collimation was found to provide the best image quality from the primary 185 keV gamma emission of 67 Cu. Reconstructed images of 67 Cu were similar in quality to images acquired using 177 Lu. Recovery coefficients were calculated and compared against quantitative images of 99m Tc, 177 Lu, and 64 Cu within the same anthropomorphic chest phantom. Production and clinical imaging of 67 Cu appears feasible, and future studies investigating the therapeutic efficacy of 67 Cu-based radiopharmaceuticals are warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

LLNL International Working Group on Gamma Spectrometry - Preparation of IDB Dataset

The spectral information and associated metadata, including source information, detector setup, and shielding configuration is described in human readable, comma-separated text files (csv). Five csv files are associated with each material type and include the following information (where [Isotope] is U, Pu, and MOX): [Isotope]_measurement_metadata - Metadata of the measurement configuration, including material composition at time of acquisition (decay corrected from certificate date). Data that is unique to a measurement configuration e.g. detector geometry, source-detector distance, analyzer and other electronics used, attenuating materials are provided in this file. [Isotope]_spectrum_metadata - The information that is unique to the spectrum. This includes detector specifications (e.g. date of acquisition, number of channels, gain (keV/channel), energy range, real and live time, full width half-maximum (FWHM) of the 186 or 208 peak for uranium or plutonium measurements, respectively. [Isotope]_source_metadata - The source material used for the measurement, this includes the ratio and uncertainties of isotopes present and processing information of the material. In addition, the certificate information for the source material is listed. [Isotope]_spectrum_counts_metadata - The counts per channel for each spectrum. This data is linked via the UID.spectrum index to the measurement_metadata file. [Isotope]_spectrum_checksum_metadata The MD5 checksum for the original spectrum file. This data is linked via the UID.spectrum index to the measurement_metadata file. This information is provided to prevent duplication of entries in the database.

42 ENGINEERING↗

LLNL International Working Group on Gamma Spectrometry - Preparation of IDB Dataset [Slides]

The spectral information and associated metadata, including source information, detector setup, and shielding configuration is described in human readable, comma-separated text files (csv). Six csv files are associated with each material type and include the following information (where [Isotope] is U, Pu, and MOX): [Isotope]_measurement_metadata Metadata of the measurement configuration, including material composition at time of acquisition (decay corrected from certificate date). Data that is unique to a measurement configuration e.g. detector geometry, source-detector distance, analyzer and other electronics used, attenuating materials are provided in this file. [Isotope]_spectrum_metadata The information that is unique to the spectrum. This includes detector specifications (e.g. date of acquisition, number of channels, gain (keV/channel), energy range, real and live time, full width half-maximum (FWHM) of the 186 or 208 peak for uranium or plutonium measurements, respectively. [Isotope]_source_metadata The source material used for the measurement, this includes the ratio and uncertainties of isotopes present and processing information of the material. In addition, the certificate information for the source material is listed. [Isotope]_spectrum_counts_metadata The counts per channel for each spectrum. This data is linked via the UID.spectrum index to the measurement_metadata file. [Isotope]_spectrum_checksum_metadata The MD5 checksum for the original spectrum file. This data is linked via the UID.spectrum index to the measurement_metadata file. This information is provided to prevent duplication of entries in the database. [Isotope]_provenance Details on the csv data provider, including laboratory and contract information.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Mark-18A Loading Capacity and Dilute Acid Rinse of DGA Resin

Savannah River National Laboratory is developing a separations flowsheet for the recovery of valuable elements from irradiated 242 Pu targets. The primary impetus for this effort is to recover the rich amount of 244 Pu contained in the targets, however, the targets also contain other valuable isotopes such as heavy Cm and 241,243 Am. DGA Resin, developed by Eichrom Technologies Inc., was selected to recover these materials from the 7 – 9 M HNO 3 matrix raffinate of the anion exchange process used to separate Pu. The resin has a high affinity for trivalent actinides and rare earth elements (REEs) in moderate to strong nitric acid. After loading the resin, the extracted materials (including Cm and Am) are to be recovered as oxides in a two-step process by thermally drying and reducing the mass and volume of the resin in the process column followed by calcination of the resultant residue. It is desirable to reduce the amount of residual HNO 3 in the resin bed prior to these furnace operations, but the reduced acid concentration is known to lower the distribution coefficients of the components of interest to the extractant. The purpose of this study was to validate the loading capacity of the resin and determine losses to be expected from rinsing the loaded resin with dilute HNO 3 .

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Electric dipole excitations near the neutron separation energies in 96 Mo

Electric dipole strength near the neutron separation energy significantly impacts nuclear structure properties and astrophysical scenarios. These excitations are complex in nature and may involve the so-called pygmy dipole resonance (PDR). Transition densities play a crucial role in understanding the nature of nuclear excited states, including collective excitations, as well as in constructing transition potentials in DWBA or coupled-channels equations. In this work, we focus on electric dipole excitations in spherical molybdenum isotopes, particularly 96 Mo, employing fully consistent Hartree-Fock-Bogoliubov (HFB) and Quasiparticle Random Phase Approximation (QRPA) methods. We analyze the dipole strength near the neutron separation energy, which represents the threshold for neutron capture processes, and examine the isospin characteristics of PDR states through transition density calculations. Examination of proton and neutron transition densities reveals distinctive features of each dipole state, indicating their isoscalar and isovector nature. We observe that the primary component in the enhanced low-energy region exhibits isovector character. The PDR displays a mixture of isoscalar and isovector nature, distinguishing it from the isovector giant dipole resonance (IVGDR). These findings lay the groundwork for future investigations into the role of transition densities in reaction models and for their application to inelastic scattering calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Discovery of the new isotope 251 Lr and the α-decay fine structure in 253 L

The products of the 203, 205 Tl ( 50 Ti, 2n) fusion-evaporation reactions were studied using the recently commissioned Argonne Gas-Filled Analyzer at Argonne National Laboratory. Two α-decay activities with energies of 9210(19) and 9246(19) keV and half-lives of $42^{+42}_{-14}$ and $24.4^{+7.0}_{-4.5}$ ms were observed which were followed by the known α decays of 247 Md and 243 Es . They are interpreted as originating from the 1/2 ⁻ [521] and 7/2 ⁻ [514] single-proton Nilsson states in the hitherto unknown isotope 251 Lr . From the measured Q α values the 1/2 ⁻ level was placed 117(27) keV above the 7/2 - level in 251 Lr in contrast to 255 Lr where the 1/2 ⁻ level is the lowest. Also, the α decay of 253 Lr was studied in more detail and a new α line at 8660(20) keV was found and a new half-life value of 2.46(32) s for an isomeric state in 253 Lr was measured. The 251, 253, 255 Lr Q α values were compared with predictions of various mass models. The relative energies of the 1/2 ⁻ [521] and 7/2 ⁻ [514] single-proton Nilsson states in 251, 253, 255 Lr isotopes were compared with results of the cranking shell model with pairing treated using the particle-number-conserving method. The level separation and, in particular, the level order change between 251 Lr and 255 Lr was reproduced only when the hexacontetrapole deformation ϵ 6 was included in the calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Developments and Challenges in the Design of the ITER DRGA

We report the ITER Diagnostic Residual Gas Analyzer (DRGA) will measure the distribution of gas species, i.e., deuterium (D), tritium (T), and impurities, in the divertor exhaust stream and in the plasma periphery, with time resolution relevant to fusion plasma–wall particle dynamics. The uniqueness of the DRGA, over previous implementations of plasma dynamics residual gas analysis, is an integrated approach, combining mass and low-temperature plasma-activated optical spectroscopy, in a differentially pumped analysis station. A further unique feature of the ITER divertor-specific DRGA is an ~8-m separation of the analysis station from the sampled pumping duct, while still maintaining a ~1-s response time for hydrogen isotopic concentrations. ITER DRGA final design activities are strongly benefiting from testing of prototypical DRGA components and methods on present fusion devices, most currently on JET and W7-X. DRGA systems are implemented on both these devices and include sensors (and pumping methods) that are directly relevant to the ITER DRGA design. The recent JET-DTE2 campaign has provided the first experience on operating the combined ITER DRGA sensors with D-T plasmas. While enhancing system design for ITER, this experience on operating devices has also revealed additional engineering challenges, which further guide the continuing final design project. Meanwhile, the recent determination that the ITER DRGA, with slight optimization, will resolve the helium isotopes well enough to support an ITER pre-DT, He-3-based heating scheme, has greatly increased ITER Research Program interest in the DRGA and its implementation well ahead of the DT phase.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Demonstration of a 228 Ra/ 228 Ac isotope generator

An isotope generator to produce 228 Ac from 228 Ra was developed using a cation exchange resin column eluted with an acetate-diethylenetriaminpentaacetic acid buffer. Here, the elution behavior of 228 Ac on the column was studied with solutions of various pHs to select the optimal conditions. Two identical isotope generators were eluted for 47 days with over 100 mL of eluant with no detectable 228 Ra breakthrough and high 228 Ac yields (∼95%). The separation requires only biocompatible reagents and is performed at pH 4.6, conditions suitable for radiopharmaceutical studies of Ac.

and nuclear chemistry↗

Round Robin Analysis of Uranium Isotopics on Cotton Swipes Measured Using Microextraction-Based Sampling Versus Conventional Bulk Analysis

A comparison of microextraction sampling methods to directly analyze uranium isotopics on cotton swipes was performed concurrently with traditional bulk-processing methods. For the microextraction sampling approach, two different detection platforms were evaluated, a quadrupole-based inductively coupled plasma mass spectrometer (ICP-MS) and the liquid sampling-atmospheric pressure glow discharge (LS-APGD) coupled to an Orbitrap mass spectrometer. Results presented from this innovative sampling approach (i.e., microextraction) are compared with a more traditional approach employed for analysis of cotton-based environmental swipes, namely bulk ashing/digestion, separation, and subsequent analysis by high-precision multi-collector ICP-MS. Overall, the microextraction approach proved to be a reliable and accurate means to determine isotopic ratios of uranium collected on cotton swipes. The ICP-MS-based detection had relative standard deviations of <0.65% for the major isotopic determinations, whereas the LS-APGD-Orbitrap method had relative standard deviations of <3%. The percent relative difference for the 235 U/ 238 U ratios, in comparison to the expected values, was <1% for ICP-MS and <4% for the microplasma-Orbitrap method. Additionally, the microextraction ICP-MS accurately (<2%) and precisely (<5%) determined the minor isotopic compositions (i.e., 234 U/ 238 U and 236 U/ 238 U).

ICP-MS↗

The Use of Silver Chloride Injection in Remediation of Iodine-129 by In Situ Capture as Silver Iodide at the F-Area Seepage Basin - 20225

The Savannah River Site (SRS) produced tritium, plutonium, and special nuclear materials for national defense, medicine, and the space programs. As part of operations, the F-Area Seepage Basins operated until 1988 for the disposition of deionized acidic wastewater from the F Separations Facility. The wastewater contained dilute nitric acid and low concentrations of non-radioactive metals, and radionuclides, with the major isotopes being Cs-137, Sr-90, U-235, U-238, Pu-239, Tc-99, I-129, and tritium. The seepage basins were closed in 1988 and backfilled and capped by 1991. The groundwater emanating from beneath the closed and capped seepage basins is acidic and contains elevated levels of both chemical and radiological contaminants. Releases from the groundwater plumes sourced from the F-Area Seepage Basins have impacted the water quality of Fourmile Branch, which is a small tributary to the Savannah River, a regional water source. A large pump-and-treat system was constructed in 1997 and operated until 2003 in an attempt to capture the releases to Fourmile Branch. The system in F Area and a similar system in H Area were expensive (∼$1.3 M/month) to operate and produced large quantities of radioactive waste, with concentrations of I- 129 too high to be disposed of at the SRS. In 2004, SRS replaced pump-and-treat with a funnel and gate system that along with operation of a base injection system at the gates reduces the flux of contaminants to the wetlands adjacent to Fourmile Branch. The alkaline solution injected into the aquifer neutralizes the acidic plume and immobilizes many of the cationic constituents. However, base injection is not effective in managing the release of iodine-129, an anionic contaminant. To address iodine-129 SRS and the Savannah River National Laboratory developed an in situ technology that uses ultra-fine ground silver chloride (AgCl) as an injectable capture medium for the sequestration of iodine-129. The AgCl amendment has a very small particle size and is designed to be injected into the contaminated aquifer to capture iodine-129. Dissolved iodine-129 forms a stable and highly insoluble solid (silver iodide) upon contact with AgCl. Laboratory studies, a field scale pilot test (2009), and three deployments (2011, 2015 and 2019) of AgCl have been successfully performed at the F-Area Seepage Basins. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Separating $${^{39}\hbox {Ar}}$$ from $${^{40}\hbox {Ar}}$$ by cryogenic distillation with Aria for dark-matter searches

Abstract Aria is a plant hosting a $${350}\,\hbox {m}$$ 350 m cryogenic isotopic distillation column, the tallest ever built, which is being installed in a mine shaft at Carbosulcis S.p.A., Nuraxi-Figus (SU), Italy. Aria is one of the pillars of the argon dark-matter search experimental program, lead by the Global Argon Dark Matter Collaboration. It was designed to reduce the isotopic abundance of $${^{39}\hbox {Ar}}$$ 39 Ar in argon extracted from underground sources, called Underground Argon (UAr), which is used for dark-matter searches. Indeed, $${^{39}\hbox {Ar}}$$ 39 Ar is a $$\beta $$ β -emitter of cosmogenic origin, whose activity poses background and pile-up concerns in the detectors. In this paper, we discuss the requirements, design, construction, tests, and projected performance of the plant for the isotopic cryogenic distillation of argon. We also present the successful results of the isotopic cryogenic distillation of nitrogen with a prototype plant.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Extraction of Pm-147 from savannah river site nuclear material management programs

The Savannah River Site (SRS) processes used-nuclear fuel to recover uranium. There are many interesting fission products lost in the raffinate from this separation including 147 Pm. Here, the goal of this work was to recover 147 Pm from SRS waste solutions. A radiochemical separation method typically used for the determination of 147 Pm and 151 Sm was modified to purify significant quantities of 147 Pm from the H Canyon waste solutions. The developed scheme was tested on a small aliquot of waste solution from the processing of used fuel from the High Flux Isotope Reactor at Oak Ridge National Laboratory.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Gross and Net Soil Methane Flux and Ancillary Data, Edgewater, MD, USA, summer 2022

This data package contains measurements used to quantify methane cycling and environmental conditions in coastal forest soils during the 2022 growing season. It includes time‑series data of soil methane flux, soil respiration, soil temperature, and volumetric water content collected from soil monoliths transplanted along an inundation and salinity gradient. The package also provides one‑time measurements from a stable‑isotope pool‑dilution incubation, including gravimetric water content, methane headspace concentrations, and ¹³CH₄ enrichment over time. Data files are provided in comma‑separated values (CSV) format, with accompanying metadata and readme documentation in PDF and plain‑text formats. All files can be opened with standard software such as R, Python, or spreadsheet programs capable of handling CSV files. The metadata file describes variable definitions, units, processing steps, and the structure of each data table to support reuse and integration with other datasets.

13-C↗

Mini-99 Experiment Design and Target Assembly

Qualification of nuclear fuels requires an understanding of a myriad of fuel performance variables, which requires time-consuming irradiations in test reactors. Accelerating burnup accumulation to reduce the irradiation time has historically been accomplished by increasing the 235 U enrichment in integral fuel tests, which inherently couples the fuel’s temperature and fission heat generation. Separate effects irradiation testing of nuclear fuel, using the MiniFuel target in the Oak Ridge National Laboratory’s (ORNL’s) High Flux Isotope Reactor (HFIR), offers an approach for decoupling fuel temperature and fission rate by reducing the quantity of the fuel and relying primarily on gamma heating in the surrounding components to drive fuel temperatures. However, if the fission rate is high enough, the fuel temperature will still vary over time as the fission heating changes, primarily due to poor heat conduction between the fuel and the surrounding components. This work details the design, analysis, and fabrication of a MiniFuel target which utilizes sodium bonding to improve the heat rejection from the fuel specimen, enabling the testing of higher 235 U enrichments (~8wt.%) to further accelerate burnup accumulation without prohibitively large temperature variations throughout the course of the irradiation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗