Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ion mobility”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Next Generation Chemical Agent Detection Architecture [Poster]

Sandia National Labs (SNL)-designed, portable chemical warfare agent (CWA) detection systems consist of three-stages: collection, separation, and detection. We use microfabrication technologies to miniaturize these stages and to reduce the overall size, weight, power, and (potentially) cost of the final system. Our newest system consists of a multi-dimensional separation stage and an miniature ion mobility spectrometer (IMS) detector for unprecedented system sensitivity, selectivity, and depth of target list.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Agilent AgileBioFoundry CRADA (Final Report)

The mission of this CRADA with Agilent was to couple powerful MS platforms (QQQ, IM-QTOF-MS) with Agilent’s novel Ultra-High-Performance Liquid Chromatography (UHPLC) fast metabolomic workflows and perform ABF Machine Learning (ML) to generated datasets. Agilent transferred UHPLC methods to PNNL and LBNL and methods were implemented and demonstrated in both labs, achieving total acquisition times of < 10 min. Metabolites analyzed using Agilent’s shared methods included metabolites from central carbon metabolism, common across hosts, and metabolites unique to engineered strains. Standards were acquired in an UHPLC-Drift Tube Ion Mobility Mass Spectrometer (DTIMS) system for the first time within the context of ABF and methods were optimized based on Agilent’s protocols. Samples from ABF hosts Pseudomonas putida, Aspergillus pseudoterreus, Aspergillus niger and Rhodosporidium toruloides were analyzed using the UHPLC-DTIMS platform for a total of 276 runs. A data analysis workflow compatible with the Experimental Data Depot (EDD) and completely shareable was developed for the acquired UHPLC-DTIMS data. Samples were analyzed using a Data Independent Acquisition Approach (DIA), which for most of the standards provided more transitions therefore increasing detection confidence. Using the data acquired by PNNL, LBNL, and Agilent’s specifications from previous ML projects, SNL applied an ensemble ML strategy to pick the best performing model for automated LC-method selection. Finally, with the contribution of the participant labs and Agilent, SNL developed an Automated Method Selection (AMS) software tool to predict the best liquid chromatography method for analysis of any new molecules of interest. Samples with novel pathways and new metabolite targets of interest are generated at a high pace in the ABF. Therefore, our accomplishment in this CRADA improved the efficiency and accuracy of strain testing by developing and implementing fast analytical methods, robust processing tools, and software for predicting the best methods for UHPLC analysis.

97 MATHEMATICS AND COMPUTING↗

Resolving Lipid Structures for Threat-Agnostic Signatures

Development of threat-agnostic biosignatures is critical for the detection of and response to biological threats that go beyond the historical list-based approach. Lipids are a class of structurally diverse biomolecules that hold great promise as relevant threat-agnostic biosignatures, yet the fundamental challenge of resolving and decoding structural differences among lipids remains an obstacle in the pursuit of signature development. Structural analysis of complex lipids remains stymied due to spectral complexity and the inability to resolve low abundance lipids. To address these challenges, we integrated ozonolysis with ion mobility mass spectrometry (IMS-MS) analysis to determine the structural information for complex lipid species and (2) reduced lipid sample complexity prior to introduction into the IMS-MS using normal phase high pressure liquid chromatography (HPLC) to enable the ozonolysis of low abundance lipids. We applied these new capabilities to define the lipid structures in antimicrobial resistant (AMR) and antimicrobial susceptible (AMS) biothreat organism Yersinia pestis and cells infected with Severe Acute Respiratory Syndrome coronavirus 2 (SARS-CoV-2) variants.

59 BASIC BIOLOGICAL SCIENCES↗

Molecular Hypernetworks for Exploration of Multi-Dimensional Metabolomics Data (Chyper)

Orthogonal separations of data from high-resolution mass spectrometry can provide insight into sample composition and help address the challenge of complete annotation of molecules in untargeted metabolomics. “Molecular networks” (MNs), as used, for example, in the Global Natural Products Social Molecular Networking platform, are an increasingly popular computational strategy for exploring and visualizing molecular relationships and improving annotation. MNs use graph representations to show the relationships between measured multidimensional data features. MNs also show promise for using network science algorithms to automatically identify targets for annotation candidates and to dereplicate features associated to a single molecular identity. However, more advanced methods may better represent the complexity present in samples. Our work aims to increase confidence in annotation propagation by extending molecular network methods to include “molecular hypernetworks” (MHNs), able to natively represent multiway relationships among observations supporting both human and analytical processing. In this paper we first introduce MHNs illustrated with simple examples, and demonstrate how to build them from liquid chromatography- and ion mobility spectrometry- separated MS data. We then describe a method to construct MHNs directly from existing MNs as their “clique reconstructions”, demonstrating their utility by comparing examples of previously published graph-based MNs to their respective MHNs.

59 BASIC BIOLOGICAL SCIENCES↗

Agilent AgileBioFoundry CRADA

NTESS, LBNL, PNNL, and Agilent are collaborating to expand a prototype system that processes hundreds of samples per day by UHPLC-QTOF mass spectrometric-based target methods for both metabolomic and proteomic application sin support the needs of strain optimization. Extending this technology to targeted triple quadrupole and drift tube ion mobility spectrometry mass spectrometric analyses offers direct advantages.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Agilent CRADA (Abstract)

The CRADA between Agilent Technologies Inc. and Battelle will focus on five software components as listed below: Prototype 4D Feature Finding functionality with a particular focus on recovering low level features and extending the bottom end dynamic range of IM-MS technology. Compare and contrast developments to current 4D Feature Finding capabilities. Highlight important algorithmic aspects employed. Implement the PNNL saturation correction algorithm. Agilent will give PNNL the needed data file access API and assistance in understanding it implementation and any needed instrumental aspects. Supported high resolution products to include Agilent’s TOF, QTOF and IM-QTOF mass spectrometers. PNNL will then work with Agilent to benchmark performance. Implementation of the PNNL Hadamard de-multiplexing algorithm. Agilent will give provide PNNL the needed date file access API access and as needed assistance in understanding the current Agilent multiplexed IM offering. PNNL will then work with Agilent on benchmark performance. Add ion mobility collision cross sections to existing and new metabolomic libraries for data analysis with Agilent’s informatics program MPP/ID Browser. PNNL will work with Agilent to create a software pipeline that takes data from chemical and metabolic standards and properly formats it for inclusion in MPP accessible libraries, using the collision cross section as a new separation dimension. Improvements of MPP multidimensional matching to identify metabolomic features using multiple characteristics beyond retention time and accurate mass. Most significantly matching will include analyte collision cross section with proposed support for sample fraction or RapidFire cartridge and fragmentation spectra. PNNL will work with Agilent to modify and improve the current MPP analysis pipeline to allow for creating, aligning, and identifying MS features defined by accurate mass, collision cross section and chromatographic retention time. As additional criteria such as fraction or RapidFire cartridge type are supported in the identification process, then they also will become part of the automation workflow. This includes the automation of said system to work with command line program (i.e. not a GUI) sufficient for programmatic execution in a pipeline.

97 MATHEMATICS AND COMPUTING↗

FY24 Progress Report on Viscosity and Thermal Conductivity Measurements of Nuclear Industry Relevant Chloride Salts: An Experimental and Computational Study

As presented in this report, experimental and computational techniques were performed to assess the viscosity and thermal conductivity of key alkali and actinide chloride mixtures for molten salt reactor developers. These mixtures were pure LiCl, NaCl-KCl, LiCl-NaCl, LiCl-KCl, LiCl-NaCl-KCl, and NaCl-UCl 3 . Experimental measurements of viscosity were performed with a rolling ball viscometer, whereas experimental measurements of thermal conductivity were performed with a variable gap apparatus. Additional benchmarking work was performed using both property measurement systems to prepare for x-ray radiography in stainless-steel crucibles for viscosity and to ensure that calibration methods were accurate for thermal conductivity before assessing the NaCl-UCl 3 system. Validation data for the NaCl-UCl 3 in literature are minimal. Details on the calibration methods, salt measurement processes, and sources of error and uncertainty are discussed in detail for both property measurements. The computational methods described herein involved ab-initio molecular dynamics (AIMD) calculations using CP2K. The calculations were performed for the LiCl-KCl-NaCl and NaCl-UCl 3 systems. These calculations not only provided thermophysical property estimations for comparison to experimental data, but they also allowed for the determination of diffusion coefficients, coordination numbers, and radial distribution functions to provide insight into ion mobility and local coordination environments, which is linked to macroscopic property trends.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Molecular Vision - Multimodal, multitask retrieval of molecular structure from measured signatures for reference-free compound identification

We are currently at risk of generating false conclusions based on limited methods to identify small molecules in biological systems and in chemical forensics. By definition, the chemical structures of novel small molecules have not been determined, let alone measured or synthesized. Currently, unambiguous structure determination of small molecules is constrained by the time and effort needed to isolate compounds and perform de novo structure elucidation using laboratory-based methods, significantly extending the time to inform mitigation strategies. To address this gap, we have developed a deep learning approach to directly map molecular structure to experimental signatures. We aim to unify measurement technologies employed in untargeted small molecule identification studies—such as infrared (IR) spectrometry, tandem mass spectrometry (MS/MS), ion mobility spectrometry-derived collision cross section (CCS)—through use of a multimodal, multitask deep learning architecture. Where existing methods require direct generation of information-rich spectra and/or properties, an inherently difficult task, we will simplify molecular signature-based identification by posing the problem as a recognition or retrieval task. The model is thus presented with relevant endpoints – structure and one or more molecular signatures – and need only determine whether they are semantically related. Thus, our approach offers the following advantages over existing techniques: (i) circumvents difficulties associated with direct generation of molecular signatures from structure and structure from signatures; (ii) incorporates multiple molecular signatures simultaneously, as available, to support identification; and (iii) enables rapid computation of structural embeddings toward broad coverage of known chemical space. Taken together, the approach removes the need to explicitly obtain or compute reference spectra, representing a powerful method for compound identification that requires only experimentally observed signatures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Tuning Solvation Dynamics of Electrolytes at Their Eutectic Point Through Halide Identity

Deep eutectic solvents (DESs) are regarded as highly promising solvent systems for redox flow batteries. DESs, composed of choline halides (ChX, X = F − , Cl − , Br − , I − ) and ethylene glycol (EG), exhibit distinct physicochemical properties at their eutectic points, including halide-dependent phase behavior, viscosity, polarity, conductivity, and solvation dynamics. In this study, we investigate the effects of the halide identity on the solvation properties of ChX:EG mixtures at varying mol % of ChX salt content. The solvatochromic polarity based on ET(30) measurements indicates higher polarity for larger halides (I − > Br − ) than for smaller halides (Cl − > F − ), which exhibit larger compensating solvation shells. The ionic conductivity follows the trend of the solvent fluidity (the inverse of the viscosity), namely ChCl > ChBr > ChI > ChF, influenced by the ion mobility and solvodynamic radii. Measurements of the liquidus temperatures (T L ) reveal that the system with ChCl exhibits the deepest eutectic point (at ~20 mol % ChCl), while ChBr and ChI have shallower minima at ~10 mol % ChBr and ~3 mol % ChI, respectively. ChF does not display a eutectic transition but instead appears to readily supercool at salt concentrations above 30 mol % ChF. Consistent with the phase transition measurements, femtosecond transient absorption spectroscopy shows that in the ChCl system, the solvation dynamics become faster with an increasing salt concentration up to ~16.67 mol %, after which the dynamics slow down with further increases in the salt content. The ChF-based system exhibits similar behavior, though with slower dynamics. In contrast, the solvation dynamics of the systems containing ChBr and ChI monotonously slow down with an increasing salt concentration, in agreement with the phase transition measurements, which show that the eutectic points occur at low salt concentrations. These measurements suggest that the solvent composition and, in particular, the identity of the halide anion play a significant role in the solvation behavior of these ethylene-glycol-based DESs, offering a foundation for tuning the DES properties for specific applications.

Biochemistry & Molecular Biology↗

Photonitride passivating coating for IC's

Increased reliability and simplified fabrication result from postassembly preencapsulation passivation process. Photonitride reaction chamber receives silane, ammonia, and mercury from mixing manifold to form passivating coating on IC's. Photonitride layer is barrier to moisture and penetration by mobile ions, and helps to protect IC devices subjected to severe mechanical handling or circuit repair procedures. Process is compatible with variety of wire-bonded lead frame assemblies. Advantages over plasma and sputtering deposition processes are low deposition temperature and zero stray radiation and ion levels.

Hall, T. C.↗

Silicon nitride passivation of IC's

Feasibility study looks at effectiveness of silicon nitride passivation coating against moisture and mobile ions. Coating was tested on CMOS microcircuits. Tests included temperature cycling, high-temperature electrical stress, and temperature and humidity exposure. Report concludes plastic-encapsulated circuits with protective coating exhibit high survival rates; it includes tables summarizing test results and figures that show effects of flexing.

Erickson, J. J.↗

Improved Model for MOS Breakdown

With an improved model, accelerated high-field tests can be used to predict gate-oxide breakdown in metal-oxide-semi-conductor (MOS) structures. Principal mechanism in MOS breakdown is mobile-ion emission from metal/oxide interface, which occurs during application of positive gate-bias field. Breakdown is related to clustering of emitted ions at localized defect sites in oxide/silicon interface. Using new model to interpret data, tests that normally take several weeks at low fields to accumulate sufficient statistics can be completed in only a few hours at high fields.

Li, S. P.↗

Thin N-I-P radiation resistant solar cells

Several sets of N-I-P sola cells were fabricated from high resistivity silicon to test the effectiveness of various methods for hardening these devices against radiation. Different substrate materials were used to provide information on the effects of dopant concentration, silicon type, and the presence of oxygen. In some cells, P-type float-zone refined silicon of 800, 8000 and 15,000 omega-cm resistivity was used to provide a basis for studying resistivity and purity effects. In other cells, N-type silicon (approximately 800 omega-cm) was used to allow a comparison of dopant type. Oxygen-rich, crucible-grown, silicon (approximately 100 omega-cm, p-type) will provide information on purity effects and defect gettering. Lithium was introduced into different types of silicon to determine if mobile ions can reduce radiation induced defects in high resistivity material. Thin cells (2 mil) were fabricated to study the effects of cell thickness and carrier injection on radiation damage. The electrical characteristics of the different sets of cells were measured, analyzed, and compared prior to shipment of the cells to NASA/Lewis for irradiation.

Meulenberg, A.↗

Gas chromatography: Possible application of advanced instrumentation developed for solar system exploration to space station cabin atmospheres

Gas chromatography (GC) technology was developed for flight experiments in solar system exploration. The GC is a powerful analytical technique with simple devices separating individual components from complex mixtures to make very sensitive quantitative and qualitative measurements. It monitors samples containing mixtures of fixed gases and volatile organic molecules. The GC was used on the Viking mission in support of life detection experiments and on the Pioneer Venus Large Probe to determine the composition of the venusian atmosphere. A flight GC is under development to study the progress and extent of STS astronaut denitrogenation prior to extravehicular activity. Advanced flight GC concepts and systems for future solar system exploration are also studied. Studies include miniature ionization detectors and associated control systems capable of detecting from ppb up to 100% concentration levels. Further miniaturization is investigated using photolithography and controlled chemical etching in silicon wafers. Novel concepts such as ion mobility drift spectroscopy and multiplex gas chromatography are also developed for future flight experiments. These powerful analytical concepts and associated hardware are ideal for the monitoring of cabin atmospheres containing potentially dangerous volatile compounds.

Carle, G. C.↗

Wafer level reliability for high-performance VLSI design

As very large scale integration architecture requires higher package density, reliability of these devices has approached a critical level. Previous processing techniques allowed a large window for varying reliability. However, as scaling and higher current densities push reliability to its limit, tighter control and instant feedback becomes critical. Several test structures developed to monitor reliability at the wafer level are described. For example, a test structure was developed to monitor metal integrity in seconds as opposed to weeks or months for conventional testing. Another structure monitors mobile ion contamination at critical steps in the process. Thus the reliability jeopardy can be assessed during fabrication preventing defective devices from ever being placed in the field. Most importantly, the reliability can be assessed on each wafer as opposed to an occasional sample.

Root, Bryan J.↗