Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “injection test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Unbinned extraction of $γ$ from $B\to DK$ with normalizing flows

We introduce an unbinned method for extracting the CKM angle $γ$ from the decay chain $B^\pm \to (D \to K_S π^+ π^-) K^\pm$ using normalizing flows (NFs). The NFs, trained on $D$ decay data, learn a faithful continuous representation of the amplitude and strong phase variation over the $D\to K_Sπ^+π^-$ Dalitz plot whose fidelity improves with increased data sample sizes. With this input, the $B$ decay data can be used to extract the parameters $r_B$, $δ_B$, and $γ$. We test the method on Monte Carlo generated data, where it successfully recovers the injected value of $γ$ within uncertainties. The present implementation propagates statistical uncertainties from finite training data via an ensemble of independently trained flows, and does not attempt to capture the effects of systematic experimental errors. We explore two versions of the method that differ in how the trigonometric constraint on phase variation is encoded, and comment on the possible extension to Bayesian NFs, which would provide direct uncertainty estimates on the learned densities without requiring ensemble training.

Grossman, Yuval [Cornell U., LEPP]↗

Degradation Dynamics of Perovskite Solar Cells Under Fixed Reverse Current Injection

Previous studies of reverse-bias stability in perovskite solar cells have focused primarily on voltage controlled reverse-bias tests. Here we instead present an investigation of perovskite solar cell degradation under well-defined, constant reverse-current stress. We show that the choice of hole-transport layer dictates the dominant degradation pathway: cells using thick poly(triphenylamine) (PTAA) layers with better indium-doped tin oxide (ITO) coverage can tolerate high reverse bias but quickly undergo catastrophic breakdown under fixed reverse current near their one-sun maximum power-point. In contrast, cells modified with the phosphonic-acid interface layer MeO-2PACz, with poorer ITO coverage compared to PTAA, exhibit soft, gradual, and largely recoverable degradation, regardless of the shading conditions. For MeO-2PACz devices, degradation increases with both current magnitude and duration. Importantly, when normalized by injected charge (current times duration), lower currents applied over longer times cause more severe degradation than higher currents over shorter periods. Combining electrical measurements with spatially resolved photoluminescence imaging, we argue against shunt formation and instead support an ion- and charge-mediated interfacial electrochemical degradation mode.

Applied Physics (physics.app-ph)↗

Permeability-controlled migration of induced seismicity to deeper depths near Venus in North Texas

Abstract Migration of seismic events to deeper depths along basement faults over time has been observed in the wastewater injection sites, which can be correlated spatially and temporally to the propagation or retardation of pressure fronts and corresponding poroelastic response to given operation history. The seismicity rate model has been suggested as a physical indicator for the potential of earthquake nucleation along faults by quantifying poroelastic response to multiple well operations. Our field-scale model indicates that migrating patterns of 2015–2018 seismicity observed near Venus, TX are likely attributed to spatio-temporal evolution of Coulomb stressing rate constrained by the fault permeability. Even after reducing injection volumes since 2015, pore pressure continues to diffuse and steady transfer of elastic energy to the deep fault zone increases stressing rate consistently that can induce more frequent earthquakes at large distance scales. Sensitivity tests with variation in fault permeability show that (1) slow diffusion along a low-permeability fault limits earthquake nucleation near the injection interval or (2) rapid relaxation of pressure buildup within a high-permeability fault, caused by reducing injection volumes, may mitigate the seismic potential promptly.

58 GEOSCIENCES↗

Effects of a CFD-improved dimple stepped-lip piston on thermal efficiency and emissions in a medium-duty diesel engine

Diesel piston-bowl shape is a key design parameter that affects spray-wall interactions and turbulent flow development, and in turn affects the engine’s thermal efficiency and emissions. It is hypothesized that thermal efficiency can be improved by enhancing squish-region vortices as they are hypothesized to promote fuel-air mixing, leading to faster heat-release rates. However, the strength and longevity of these vortices decrease with advanced injection timings for typical stepped-lip (SL) piston geometries. Dimple stepped-lip (DSL) pistons enhance vortex formation at early injection timings. Previous engine experiments with such a bowl show 1.4% thermal efficiency gains over an SL piston. However, soot was increased dramatically [SAE 2022-01-0400]. In a previous study, a new DSL bowl was designed using non-combusting computational fluid dynamic simulations. This improved DSL bowl is predicted to promote stronger, more rotationally energetic vortices than the baseline DSL piston: it employs shallower, narrower, and steeper-curved dimples that are placed further out into the squish region. In the current experimental study, this improved bowl is tested in a medium-duty diesel engine and compared against the SL piston over an injection timing sweep at low-load and part-load operating conditions. No substantial thermal efficiency gains are achieved at the early injection timing with the improved DSL design, but soot emissions are lowered by 45% relative to the production SL piston, likely due to improved air utilization and soot oxidation. However, these benefits are lost at late injection timings, where the DSL piston renders a lower thermal efficiency than that of the SL piston. Energy balance analyses show higher wall heat transfer with the DSL piston than with the SL piston despite a 1.3% reduction in the piston surface area. Vortex enhancement may not necessarily lead to improved efficiency as more energetic squish-region vortices can lead to higher convective heat transfer losses.

42 ENGINEERING↗

Experimental Investigation of Polymer Induced Fouling of Heater Tubes in the First-Ever Polymer Flood Pilot on Alaska North Slope

Mineral fouling in heat exchangers has been extensively investigated by researchers in recent times. The oil and gas industry has a long history of fouling issues in production systems as a result of produced fluids treatment. Due to decline in production rates in oilfields new technologies are being developed and field tested in pilots. Polymer flooding is one such technology that involves addition of polymers to injection fluids to enhance oil production. A polymer flood pilot has been set up in the Schrader Bluff viscous oil reservoir at Milne Point field on the Alaska North Slope (ANS). The results from the pilot are encouraging, however a major concern of the operator is the influence of polymer on the production system after breakthrough, especially the fouling in heat exchangers. This study investigates the propensity of polymer fouling on the heater tubes as a function of different variables, with the ultimate goal of determining safe and efficient operating conditions. This work applies a multi-experimental approach to study the severity of polymer-induced fouling in both dynamic and static states of produced fluids as well as studying the stability of polymer solutions at different temperatures. A unique experimental setup was designed and developed in-house to simulate the fouling process on the heating tube. The influence of heating tube skin temperature, tube material, and polymer concentration on fouling tendency was investigated. Each test was run five times with the same tube, and in each run, the freshly prepared synthetic brine and polymer solution was heated from 77°F to 122°F to mimic field-operating conditions. The heating time and fouling amount were recorded for each run. Dynamic Scale Loop (DSL) tests were conducted to study fouling due to polymer at different temperatures (165°F to 350°F) in a dynamic state of fluid flow where the fluids mimic the residence time of fluids in the heat exchanger on the field pilot. Cloud point measurement has also been conducted to find the critical temperature at which the polymer in solution becomes unstable and precipitates out. The morphology and composition of the deposit samples were analyzed by environmental scanning electron microscopy (ESEM) and X-ray diffraction (XRD), respectively. It was found that the presence of polymer in produced fluids would aggravate the fouling issues on both carbon steel and stainless-steel surfaces at all tested skin temperatures. Only higher skin temperatures of 250°F and 350°F could cause polymer-induced fouling issues on the copper tube surface, and the fouling tendency increased with polymer concentration. At the lower skin temperatures of 165°F, no polymer-induced fouling was identified on the copper tube. A critical temperature that is related to the cloud point of the polymer solution was believed to exist, below which polymer-induced fouling would not occur, and only mineral scale was deposited but above which the polymer would aggravate the fouling issue. The cloud point of the tested polymer solution was determined to be between 220°F and 230°F. In the DSL tests it was found that at higher skin temperatures of 250°F and 350°F tube blocking was observed in the DSL tests whereas the tests at 165°F and 200°F did not show any tube blocking in the same time period. These experiments also manifested the influence of cloud point of the solution as deposit rate increased significantly in both carbon steel and stainless-steel tubes when the skin temperature was higher than the solution cloud point. The results of this study have provided guidance to the operator for the field-operations.

Dhaliwal, Anshul↗

Experimental Studies of Low-Load Limit in a Stoichiometric Micro-Pilot Diesel Natural Gas Engine

While operating at light loads, diesel pilot-ignited natural gas engines with lean premixed natural gas suffer from poor combustion efficiency and high methane emissions. This work investigates the limits of low-load operation for a micro-pilot diesel natural gas engine that uses a stoichiometric mixture to enable methane and nitrogen oxide emission control. By optimizing engine hardware, operating conditions, and injection strategies, this study focused on defining the lowest achievable load while maintaining a stoichiometric equivalence ratio and with acceptable combustion stability. A multi-cylinder diesel 6.7 L engine was converted to run natural gas premix with a maximum diesel micro-pilot contribution of 10%. With a base diesel compression ratio of 17.3:1, the intake manifold pressure limit was 80 kPa(absolute). At a reduced compression ratio of 15:1, this limit increased to 85 kPa, raising the minimum stable load. Retarding the combustion phasing, typically used in spark-ignition engines to achieve lower loads, was also tested but found to be limited by degraded diesel ignition at later timings. Reducing the pilot injection pressure improved combustion stability, as did increasing pilot quantity at the cost of lower substitution ratios. The lean operation further reduced load but increased NOx and hydrocarbon emissions. At loads below the practical dual-fuel limit, a transition to lean diesel operation will likely be required with corresponding implications for the aftertreatment system.

03 NATURAL GAS↗

Design and Study of Inductively Coupled Plasma Chamber Components Using the SupRISE Test Device at DIII-D

The DIII-D National Fusion Facility aims to increase the auxiliary heating power for the tokamak by upgrading the Neutral Beam Injection (NBI) system. In collaboration with North Carolina State University, the conventional ‘arc and filament’ NBI ion sources will be converted to inductively coupled plasma (ICP) sources which utilize radio frequency (RF) coupling to maximize reliability for high power operation. In support of this initiative, a full scale test device (SupRISE, Superior Radiofrequency Ion Source Experiment) is currently under construction at the DIII-D Facility. In preparation for the construction of a full scale prototype that can be installed on the DIII-D NBI system, experiments on SupRISE will be conducted to determine the optimal RF frequency for high power coupling, Faraday shield slit configuration, and ICP chamber length. SupRISE is comprised of an approximately 30 x 70 cm quartz dielectric vessel with an internal Faraday shield enclosed in a secondary vacuum chamber to ensure structural stability of the dielectric. Actively cooled front and back plates are designed to reduce the thermal stresses on the plasma facing components and mate with the existing accelerator used by the NBI system at DIII-D. 50 kW of RF power will be coupled to the plasma through the quartz over a variable frequency range of 4-8 MHz to sustain a plasma density of ∼ 10 18 m −3 for a 10 s ON, 210 s OFF duty cycle. Various modelling efforts have been employed to simulate the thermal and stress profiles over the primary components of the SupRISE device as well as the inductance behavior of the RF antenna. These simulation results and the final design for SupRISE will be presented. An additional reduced-scale predecessor ICP source (called RISE) has been used to develop a predictive match model that will be applied to frequency optimization studies on SupRISE. Furthermore, the outcomes of this research and complementary efforts at North Carolina State University are essential for the incorporation of ICP NBI positive ion sources at the DIII-D facility.

DIII-D↗

Geophysical monitoring using active seismic techniques at the Citronelle Alabama CO 2 storage demonstration site

Between August 2012 and September 2014, about 114,000 metric tonnes of CO 2 was captured from the coal-fired Plant Barry Power Station at Bucks Alabama and injected into the Paluxy Formation above the oil pool in the southeast unit of the Citronelle Oilfield. Various monitoring methods were deployed at land surface and in project wells to measure system performance, comply with permit requirements and test new and innovative monitoring tools. The monitoring program relied heavily on active seismic methods for subsurface imaging of geologic structure and time-lapse seismic techniques to track the CO 2 migration in the injection interval. Both conventional geophone/hydrophone and fiber-optic based Distributed Acoustic Sensing (DAS) arrays were deployed and tested, allowing a side by side comparison of the equipment and techniques. Geophysical imaging of the subsurface was successful using DAS in the offset vertical seismic profile (OVSP) survey configuration. A high resolution OVSP image of the subsurface was obtained in 2014 with DAS, which exceeded project expectations in comparison to a lower resolution image obtained in 2012 using a conventional 80-level geophone array. A time-lapse image of the redistribution of CO 2 after injection ended in September 2014 was obtained with two DAS OVSP surveys from June 2014 and December 2015, thus successfully demonstrating its proof-of-concept. Unfortunately, a pre-injection baseline survey with DAS, which was in its initial stage of technology development in 2012, did not have sufficient quality for use, making it difficult to interpret the acquired DAS time-lapse difference. Additional research in this area has since demonstrated the utility of time-lapse DAS OVSP. DAS data were also acquired during a cross-well seismic survey conducted in 2014. Unfortunately, the DAS technique was not success in the cross-well survey configuration because the system noise level was too high in the crosswell frequency output range (100–1200 Hz) of the piezoelectric source (increasing by a factor of ten compared to VSP frequency band). Additionally, the cross-well geometry causes sub-horizontal (broadside) incidence on the vertical DAS fiber cable, which is known to be problematic. Current research is focused on improving the DAS cable response to broadside acoustic energy. Time-lapse seismic surveys using commercially available conventional arrays were also acquired. In contrast to the DAS acquired data, the cross-well seismic results obtained with the conventional array was highly successful and clearly showed the CO 2 remained in zone at the end of injection. Time-lapse differencing of the OSVP surveys acquired with the conventional arrays proved to be inconclusive. Finally, changes in wellbore conditions between surveys and unavoidable changes in equipment (the array used for the baseline survey was retired) affected data quality, making it difficult to interpret the OVSP results.

58 GEOSCIENCES↗

In-Situ Stress Measurements at the Utah Frontier Observatory for Research in Geothermal Energy (FORGE) Site

A scientific injection campaign was conducted at the Utah Frontier Observatory for Research in Geothermal Energy (FORGE) site in 2017 and 2019. The testing included pump-in/shut-in, pump-in/flowback, and step rate tests. Various methods have been employed to interpret the in-situ stress from the test dataset. This study focuses on methods to interpret the minimum in-situ stress from step rate, pump-in/extended shut-in tests data obtained during the stimulation of two zones in Well 58-32. This well was drilled in low-permeability granitoid. A temperature of 199 °C was recorded at the well’s total depth of 2297 m relative to the rotary Kelly bushing (RKB). The lower zone (Zone 1) consisted of 46 m of the openhole at the toe of the well. Fractures in the upper zone (Zone 2) were stimulated between 2123–2126 m measured depths (MD) behind the casing. The closure stress gradient variation depended on the depth and the injection chronology. The closure stress was found to increase with the pumping rate/volume. This stress variation could indicate that poroelastic effects (“back stress”) and the presence of adjacent natural fractures may play an important role in the interpretation of fracture closure stress. Further, progressively increasing local total stresses may, consequently, have practical applications when moderate volumes of fluid are injected in a naturally fractured or high-temperature reservoir. The alternative techniques that use pump-in/flowback tests and temperature signatures provide a valuable perspective view of the in-situ stress measurements.

15 GEOTHERMAL ENERGY↗

Splitting tensile strength of shale cores: intact versus fractured and sealed with ureolysis-induced calcium carbonate precipitation (UICP)

Ureolysis-induced calcium carbonate precipitation (UICP) is a biomineral solution where the urease enzyme converts urea and calcium into calcium carbonate. The resulting biomineral can bridge gaps in fractured shale, reduce undesired fluid flow, limit fracture propagation, better store carbon dioxide, and potentially enhance well efficiency. The mechanical properties of shale cores were investigated using a modified Brazilian indirect tensile strength test. An investigation of intact shale using Eagle Ford and Wolfcamp cores was conducted at varying temperatures. Results show no significant difference between shale types (average tensile strength = 6.19 MPa). Eagle Ford displayed higher strength at elevated temperature, but temperature did not influence Wolfcamp. Comparatively, cores with a single, lengthwise heterogeneous fracture were sealed with UICP and further tested for tensile strength. UICP was delivered via a flow-through method which injected 20–30 sequential patterns of ureolytic microorganisms and UICP-promoting fluids into the fracture until permeability reduced by three orders of magnitude or with an immersion method which placed cores treated with guar gum and UICP-promoting fluids into a batch reactor, demonstrating that guar gum is a suitable inclusion and may reduce the number of flow-through injections required. Tensile results for both delivery methods were variable (0.15–8 MPa), and in some cores the biomineralized fracture split apart, possibly due to insufficient sealing and/or heterogeneity in the composite UICP-shale cores. Notably in other cores the biomineralized fracture remained intact, demonstrating more cohesion than the surrounding shale, indicating that UICP may produce a strong seal for subsurface application.

58 GEOSCIENCES↗

Water alternative gas (WAG) optimization for a heterogeneous Brazilian pre-salt carbonate reservoir

Water alternating gas (WAG) is a cyclical process that involves alternating water and gas injections with the primary goal to improve sweep efficiency by maintaining initial high pressure, slowing water and gas breakthrough, and lowering oil viscosity. The objective of this work is to apply and optimize a WAG strategy on a carbonate field with light oil, compare it to the initially planned water-flooding strategy, and investigate the capability of WAG to improve field production. In this research, a compositional reservoir simulator was used to model a WAG process by injecting produced gas into the reservoir, using the same well structure as an optimized water-flooding strategy. Subsequently, a WAG strategy was created, optimizing the number and locations of wells, to facilitate a comparative analysis of the two recovery methods. The WAG optimization involved a detailed assessment of variables such as bottom hole pressure (BHP), WAG cycle duration, maximum gas oil ratio (GOR), and well positioning, to achieve a high net present value (NPV). The study focuses on the application of WAG optimization modeling in unconventional reservoirs, specifically pre-salt carbonate reservoirs, and investigates its implications on production strategy and forecast, emphasizing its potential for maximizing NPV and oil recovery in a recently producing field. The results showed that WAG improved reservoir performance when compared to water injection and produced a greater amount of oil. This solution showed potential to be tested under uncertainties (reservoir heterogeneity, faults, fractures, karsts, vugs, etc.) as future steps.

54 ENVIRONMENTAL SCIENCES↗

Shifting Left for Machine Learning: An Empirical Study of Security Weaknesses in Supervised Learning-based Projects

Context: Supervised learning-based projects (SLPs), i.e., software projects that use supervised learning algorithms, such as decision trees are useful for performing classification-related tasks. Yet, security weaknesses, such as the use of hard-coded passwords in SLPs, can make SLPs susceptible to security attacks. A characterization of security weaknesses in SLPs can help practitioners understand the security weaknesses that are frequent in SLPs and adopt adequate mitigation strategies. Objective: The goal of this paper is to help practitioners se-curely develop supervised learning-based projects by conducting an empirical study of security weaknesses in supervised learning-based projects. Methodology: We conduct an empirical study by quantifying the frequency of security weaknesses in 278 open source SLPs. Results: We identify 22 types of security weaknesses that occur in SLPs. We observe ‘use of potentially dangerous function’ to be the most frequently occurring security weakness in SLPs. Of the identified 3,964 security weaknesses, 23.79 % and 40.49 % respectively, appear for source code files used to train and test models. We also observe evidence of co-location, e.g., instances of command injection co-locates with instances of potentially dangerous function. Conclusion: Based on our findings, we advocate for a shift left approach for SLP development with security-focused code reviews, and application of security static analysis.

Bhuiyan, Farzana Ahamed↗

An Active Detection Scheme for Sensor Spoofing in Grid-tied PV Systems

In this paper an active detection scheme for sensor spoofing (manipulated externally via a cyber attack) in grid-tied PV systems is discussed. The core of the proposed active detection scheme is to introduce a private (secret) watermarking signal into the control inputs of the DC-DC converter and DC-AC inverter stages to detect any malicious spoofing (manipulation) of voltage/current sensor measurements controlling both the DC-DC converter maximum power point tracking (MPPT) stage and the DC-AC inverter of the grid-tied PV system. Several types of possible spoofing mechanisms (attack models) are discussed. The proposed sensor spoofing attack detector system consists of injecting a small magnitude of digital watermarking signal (DWS) and conduct three statistical watermark tests on the reported sensor measurements to determine if a) the proposed system is healthy and operating as expected b) if sensor signals were spoofed (manipulated) externally or c) if a particular sensor is malfunctioning due to a faulty hardware. It is shown via extensive simulations that the proposed DWS approach is robust in detecting malicious external manipulation of sensors controlling the grid tied PV system. A testing platform is currently under development and the experimental results will be discussed in the conference presentation.

Ibrahim, Hasan↗

Industry-Average Performance for Components and Initiating Events at U.S. Commercial Nuclear Power Plants: 2020 Update

This report documents the quantitative results of the current industry-average performance for components and initiating events (IEs) at U.S. commercial nuclear power plants (NPPs). It represents the third update of the original analysis in NUREG/CR-6928 with data through 2020. Continuous characterization and updating of current industry-average performance with the latest industry data available are important steps in maintaining up-to-date risk models. Typically, data from 1998–2002 were used in NUREG/CR-6928, data from 1998–2010 in the first update, data from 1998–2015 in the second update, and data from 2006–2020 in this update, although many IEs required longer periods for adequate characterization of frequencies in all these analyses. As with NUREG/CR-6928 and previous updates, four types of events are covered in this report: component unreliability (e.g., a pump that fails to start or fails to run), component or train unavailability resulting from test or maintenance outages, special event probabilities covering operational issues (e.g., pump restarts and injection valve re-openings during unplanned demands), and IE frequencies. Results (in the form of beta distributions for failure probabilities upon demand and gamma distributions for rates) are used as inputs to the U.S. Nuclear Regulatory Commission standardized plant analysis risk models covering U.S. commercial NPPs.

99 GENERAL AND MISCELLANEOUS↗

Hydraulic and Thermal Stimulation Program at Raft River Idaho, A DOE EGS

A Department of Energy Enhanced Geothermal System (EGS) stimulation program has injected over 254 million gallons of water into the well RRG-9 ST1 since the summer of 2013. Three major stimulations have been conducted during the program increasing injection flow rates from less than 20 gpm to 550 gpm. Geologic, water chemistry, microseismic activity, and borehole imaging data have been used to develop a conceptual model describing possible flow paths of this injected water. This model contains two major fracture zones one of which intersects the RRG-9 ST1 wellbore. Modified Hall and injectivity index plots constructed using injection flow rates, surface temperatures, and wellhead pressures show steady improvement in the injectivity of the well. Here, the injectivity index has risen from 0.15 gpm/psi to 2.0 gpm/ psi. A pressure falloff test conducted on April 28, 2015 indicates a reservoir permeability of 1,220 md and -5.38 skin factor. The well stimulation program was simulated numerically using an Idaho National Laboratory reservoir simulation code, FALCON. These simulations show a significant increase in the permeability of connecting fracture pathways after each stimulation event.

Enhanced geothermal system↗

Building an EPA Class VI Permit Application

Summary To accelerate the commercialization of carbon capture and storage (CCS), the US Department of Energy (US DOE) is building on decades of characterization efforts and pilot-scale projects through their CarbonSAFE program. Administered through their National Energy Technology Laboratory, this program seeks to bring fully integrated projects to the sector that can store more than 50 million tonnes of CO2 over a 30-year period. The program, which was enacted before the enhancement of Internal Revenue Code Section 45Q, is in the capture assessment, characterization, and permitting phase. The objectives of this paper are to discuss (a) the injection permitting requirements of the CarbonSAFE projects; (b) information gathering in support of the permit; (c) the timelines of field development and permit-related activities; (d) the major technical components of the field development plan; and (e) early feedback from the regulators toward acceptance of the permit. In Mississippi, more than 30,000 acres have been characterized by six deep characterization wells, a deep groundwater well, and 92 line miles of 2D seismic as part of the CarbonSAFE Project ECO2S. During the acquisition of seismic data, all receiver lines were live, which resulted in the generation of a pseudo-3D seismic design. The incorporation of a 3D seismic survey was not included as part of this project due to logistical difficulties presented by the undulating, wooded surface terrain. A suite of openhole geophysical logs was taken from each well, allowing for a detailed interpretation of prospective storage reservoirs and confining intervals to complement the analysis carried out on the 290 ft of a whole core that was cut through the prospective confining zone and storage reservoir. The detailed geologic and reservoir data were assembled and entered into a 3D model to assess the injection capacity and the area of review (AoR). This information fed into the detailed corrective action, monitoring, testing, and postinjection site care (PISC) modeling. The results have been exceptional. The geologic assessment has revealed three primary storage targets, ranging in depth from 3,500 ft to 6,000 ft. These storage reservoirs net 1,300 ft of sandstone, with mean porosity and permeability of 29% and 3.6 darcies, respectively. Together, these reservoirs have storage capacities that may exceed 20 million tonnes per square mile, making this a gigatonne prospect. Forward modeling of the project resulted in an AoR of 16 sq miles, injecting about 8000 t/d, for 30 years, via two deep injection wells. The excellent confining characteristics of the caprock, relatively simple geologic structure, and lack of historical well drilling activity in this area provide excellent containment of the injected CO2. Based on this work, the project has proposed 20 years of PISC. To date, only two US CO2 injection permits have been granted. These projects relied on a singular capture point feeding a singular sequestration point (source to sink), and considerations have not been made to garner CO2 emissions from other industrial sources. The Kemper County Storage Complex is a first-of-its-kind storage hub concept that looks to develop an area capable of storing significant quantities of CO2 from the region. Also, this work will show how characterization efforts, geological and numerical modeling efforts, and plan development were constructed in support of permit and incentives acceptance.

Energy & Fuels↗

Parametric Study of SANSMIC Input and Resulting Impact on Predicted Cavern Geometry and Leaching Efficiency

The Sandia Solution Mining Code (SANSMIC) has been used for many years to examine the development of salt cavern geometry, both in a confirmatory manner with comparisons made to real-world sonar data and in a predictive manner when updated sonar data are not available. SANSMIC models require some modeling choices in order to incorporate real-world data. Key modeling choices include the vertical resolution of cavern geometry to implement, as well as how to incorporate daily raw water injection data into the SANSMIC model. This report documents five studies that address the impact of the modeling choices on the predicted cavern geometries and calculated leaching efficiencies. In most cases, hypothetical cylindrical initial cavern geometries are used to provide a common baseline against which to test the systematic variation of input variables including cavern radius, oil-brine-interface (OBI) depth, vertical cell size, raw water injection rate, raw water injection duration, workover time, and number of leaching stages. The use of smaller cell sizes is recommended moving forward to provide a better one-to-one relationship between sonar data and the modeled cavern. A new methodology for incorporating raw water injection data is also recommended, in order to more closely model real-world injection and workover times. Overall, the systematic studies performed here have increased our confidence in previous SANSMIC model results, as well future use of the code for predicting leaching effects on cavern geometries. Some minor changes to modeling choices are recommended, which can easily be applied with the version of SANSMIC currently under development.

42 ENGINEERING↗

Machine Learning-Based Process Control for Injection Molding of Recycled Polypropylene

The increased interest in artificial intelligence in manufacturing has driven the adoption of machine learning to optimize processes and improve efficiency. A key challenge in injection molding is the variability of recycled materials, which affects part quality and processing stability. This study presents a novel closed-loop process control approach for injection molding, leveraging machine learning to adaptively predict processing inputs and quality outcomes. The methodology was tested on five blends of recycled polypropylene (rPP), using artificial neural networks (ANNs), linear regression, and polynomial regression to model the relationships between material properties and process parameters. The dataset was split 80/20 into training and testing sets. The ANN model was implemented using TensorFlow and Keras, with six hidden layers of 32 neurons per layer, ReLU activation, and an Adam optimizer. Empirical tuning and early stopping were used to optimize performance and prevent overfitting. Predictions were evaluated based on mean absolute error (MAE), mean squared error (MSE), and percentage error. The results showed that yield stress, ultimate elongation, and part weight were accurately predicted within a 5% error for linear and polynomial regression models and within a 10% error for the ANN. However, modulus predictions were less reliable, with errors of ~11% for ANN and linear regression and ~40% for polynomial regression, reflecting the inherent variability of this property in rPP blends. Predictions of processing inputs had errors ranging from 3% to 25%, depending on the model and response variable. No single modeling approach was consistently superior across all responses, highlighting the complexity of the relationship between material properties, process parameters, and quality metrics. Overall, the work demonstrates that closed-loop process control, powered by machine learning, can effectively predict key quality parameters in injection molding of recycled materials. The proposed approach can improve process stability and material utilization, facilitating increased adoption of sustainable materials.

Krantz, Joshua↗