An image filtering technique for SPIDER visible tomography

The tomographic diagnostic developed for the beam generated in the SPIDER facility (100 keV, 50 A prototype negative ion source of ITER neutral beam injector) will characterize the two-dimensional particle density distribution of the beam. The simulations described in the paper show that instrumental noise has a large influence on the maximum achievable resolution of the diagnostic. To reduce its impact on beam pattern reconstruction, a filtering technique has been adapted and implemented in the tomography code. This technique is applied to the simulated tomographic reconstruction of the SPIDER beam, and the main results are reported.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Assessment of probability of detection of delaminations in fiber-reinforced composites

Delamination is one of the critical defects in composite materials and structures. An ultrasonic C-scan imaging technique which maps out the acoustic impedance mismatched areas with respect to the sample coordinates, is particularly well suited for detecting and characterizing delaminations in composites. To properly interpret the results, it is necessary to correlate the indications with the detection limits and probability of detection (POD) of the ultrasonic C-scan imaging technique. The baseline information on the assessment of POD of delaminations in composite materials and structures is very beneficial to the evaluation of spacecraft materials. In this study, we review the principle of POD, describe the laboratory set-up and procedure, and present the experimental results as well as assessment of POD of delaminations in fiber reinforced composite panels using ultrasonic C-scan techniques.

Chern, E. J.↗

Multimodal LA-ICP-MS and nanoSIMS imaging enables copper mapping within photoreceptor megamitochondria in a zebrafish model of Menkes disease

Here, copper is essential for eukaryotic life, and animals must acquire this nutrient through the diet and distribute it to cells and organelles for proper function of biological targets. Indeed, mutations in the central copper exporter ATP7A contribute to a spectrum of diseases, including Menkes disease, with symptoms ranging from neurodegeneration to lax connective tissue. As such, a better understanding of the fundamental impacts of ATP7A mutations on in vivo copper distributions is of relevance to those affected by these diseases. For this work, we combine metal imaging and optical imaging techniques at a variety of spatial resolutions to identify tissues and structures with altered copper levels in the Calamity gw71 zebrafish model of Menkes disease. Rapid profiling of tissue slices with LA-ICP-MS identified reduced copper levels in the brain, neuroretina, and liver of Menkes fish compared to control specimens. High resolution nanoSIMS imaging of the neuroretina, combined with electron and confocal microscopies, identified the megamitochondria of photoreceptors as loci of copper accumulation in wildtype fish, with lower levels of megamitochondrial copper observed in Calamity gw71 zebrafish. Interestingly, this localized copper decrease does not result in impaired photoreceptor development or altered megamitochondrial morphology, suggesting the prioritization of copper at sufficient levels for maintaining essential mitochondrial functions. Together, these data establish the Calamity gw71 zebrafish as an optically transparent in vivo model for the study of neural copper misregulation, illuminate a role for the ATP7A copper exporter in trafficking copper to the neuroretina, and highlight the utility of combining multiple imaging techniques for studying metals in whole organism settings with spatial resolution.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Combustion Dynamics in Multi-Nozzle Combustors Operating on High-Hydrogen Fuels

Actual gas turbine combustors for power generation applications employ multi-nozzle combustor configurations. Researchers at Penn State and Georgia Tech have extended previous work on the flame response in single-nozzle combustors to the more realistic case of multi-nozzle combustors. Research at Georgia Tech has shown that asymmetry of both the flow field and the acoustic forcing can have a significant effect on flame response and that such behavior is important in multi-flame configurations. As a result, the structure of the flame and its response to forcing is three-dimensional. Research at Penn State has led to the development of a three-dimensional chemiluminescence flame imaging technique that can be used to characterize the unforced (steady) and forced (unsteady) flame structure of multi-nozzle combustors. Important aspects of the flame response in multi-nozzle combustors which are being studied include flame-flame and flame-wall interactions. Research at Penn State using the recently developed three-dimensional flame imaging technique has shown that spatial variations in local flame confinement must be accounted for to accurately predict global flame response in a multi-nozzle can combustor.

08 HYDROGEN↗

Mixing of an Airblast-atomized Fuel Spray Injected into a Crossflow of Air

The injection of a spray of fuel droplets into a crossflow of air provides a means of rapidly mixing liquid fuel and air for combustion applications. Injecting the liquid as a spray reduces the mixing length needed to accommodate liquid breakup, while the transverse injection of the spray into the air stream takes advantage of the dynamic mixing induced by the jet-crossflow interaction. The structure of the spray, formed from a model plain-jet airblast atomizer, is investigated in order to determine and understand the factors leading to its dispersion. To attain this goal, the problem is divided into the following tasks which involve: (1) developing planar imaging techniques that visualize fuel and air distributions in the spray, (2) characterizing the airblast spray without a crossflow, and (3) characterizing the airblast spray upon injection into a crossflow. Geometric and operating conditions are varied in order to affect the atomization, penetration, and dispersion of the spray into the crossflow. The airblast spray is first characterized, using imaging techniques, as it issues into a quiescent environment. The spray breakup modes are classified in a liquid Reynolds number versus airblast Weber number regime chart. This work focuses on sprays formed by the "prompt" atomization mode, which induces a well-atomized and well-dispersed spray, and which also produces a two-lobed liquid distribution corresponding to the atomizing air passageways in the injector. The characterization of the spray jet injected into the crossflow reveals the different processes that control its dispersion. Correlations that describe the inner and outer boundaries of the spray jet are developed, using the definition of a two-phase momentum-flux ratio. Cross-sections of the liquid spray depict elliptically-shaped distributions, with the exception of the finely-atomized sprays which show kidney-shaped distributions reminiscent of those obtained in gaseous jet in crossflow systems. A droplet trajectory analysis overpredicts the liquid mass penetration, and indicates a need for a more rigorous model to account for the three-dimensional mixing field induced by the jet-crossflow interaction. Nonetheless, the general procedures and criteria that are outlined can be used to efficiently assess and compare the quality of sprays formed under different conditions.

Leong, May Y.↗

Magnetic vortex nucleation modes in static magnetic fields

The magnetic vortex nucleation process in nanometer- and micrometer-sized magnetic disks undergoes several phases with distinct spin configurations called the nucleation states. Before formation of the final vortex state, small submicron disks typically proceed through the so-called C-state while the larger micron-sized disks proceed through the more complicated vortex-pair state or the buckling state. This work classifies the nucleation states using micromagnetic simulations and provides evidence for the stability of vortex-pair and buckling states in static magnetic fields using magnetic imaging techniques and electrical transport measurements. Lorentz Transmission Electron Microscopy and Magnetic Transmission X-ray Microscopy are employed to reveal the details of spin configuration in each of the nucleation states. We further show that it is possible to unambiguously identify these states by electrical measurements via the anisotropic magnetoresistance effect. Combination of the electrical transport and magnetic imaging techniques confirms stability of a vortex-antivortex-vortex spin configuration which emerges from the buckling state in static magnetic fields.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High‐speed 4‐dimensional scanning transmission electron microscopy using compressive sensing techniques

Abstract Here we show that compressive sensing allows 4‐dimensional (4‐D) STEM data to be obtained and accurately reconstructed with both high‐speed and reduced electron fluence. The methodology needed to achieve these results compared to conventional 4‐D approaches requires only that a random subset of probe locations is acquired from the typical regular scanning grid, which immediately generates both higher speed and the lower fluence experimentally. We also consider downsampling of the detector, showing that oversampling is inherent within convergent beam electron diffraction (CBED) patterns and that detector downsampling does not reduce precision but allows faster experimental data acquisition. Analysis of an experimental atomic resolution yttrium silicide dataset shows that it is possible to recover over 25 dB peak signal‐to‐noise ratio in the recovered phase using 0.3% of the total data. Lay abstract : Four‐dimensional scanning transmission electron microscopy (4‐D STEM) is a powerful technique for characterizing complex nanoscale structures. In this method, a convergent beam electron diffraction pattern (CBED) is acquired at each probe location during the scan of the sample. This means that a 2‐dimensional signal is acquired at each 2‐D probe location, equating to a 4‐D dataset. Despite the recent development of fast direct electron detectors, some capable of 100kHz frame rates, the limiting factor for 4‐D STEM is acquisition times in the majority of cases, where cameras will typically operate on the order of 2kHz. This means that a raster scan containing 256^2 probe locations can take on the order of 30s, approximately 100‐1000 times longer than a conventional STEM imaging technique using monolithic radial detectors. As a result, 4‐D STEM acquisitions can be subject to adverse effects such as drift, beam damage, and sample contamination. Recent advances in computational imaging techniques for STEM have allowed for faster acquisition speeds by way of acquiring only a random subset of probe locations from the field of view. By doing this, the acquisition time is significantly reduced, in some cases by a factor of 10‐100 times. The acquired data is then processed to fill‐in or inpaint the missing data, taking advantage of the inherently low‐complex signals which can be linearly combined to recover the information. In this work, similar methods are demonstrated for the acquisition of 4‐D STEM data, where only a random subset of CBED patterns are acquired over the raster scan. We simulate the compressive sensing acquisition method for 4‐D STEM and present our findings for a variety of analysis techniques such as ptychography and differential phase contrast. Our results show that acquisition times can be significantly reduced on the order of 100‐300 times, therefore improving existing frame rates, as well as further reducing the electron fluence beyond just using a faster camera.

Robinson, Alex W.↗

Advanced SOFC quality control and the role of manufacturing defects on stack reliability

Atrex Energy rolled out first commercial SOFC generator products in 2013. Following that we embarked on implementation of mass production in order to ramp up productivity and lower the costs in the meantime. To ensure the goal of mass production, an accurate, cost effective and consistent quality control methodology needs to be in place. The aim of this DOE funded project is to devise a machine and methodology for cell quality control using modern non-destructive testing methods and cell rejection criterion based on the empirical determination of the role of manufacturing flaws on stack degradation and reliability. The work scope encompasses two goals aimed at 1) developing automatable techniques for objective flaw detection and 2) developing an understanding of the ramifications of flaws on stack and cell reliability. By accomplishing these two goals it is likely that an advanced stage Quality Control (QC) device can be developed. This project scope encompasses: 1) Invention of a high speed automated instrument for spatial mapping of surface and sub-surface imperfections in production cells (ex situ) using modern imaging techniques. 2) Identification of rejection criteria upon which to screen cells from production by: a. Magnification of the effect of production defects on cell degradation through fabrication and testing of micro-cells which encompass these imperfections. b. The long term testing of full size production cells both as single cells and in small stacks, in order to correlate the (in situ) performance and degradation with the imperfection type (identified ex-situ) and hence be able to classify imperfections as actual defects. We first built a defect library with the cells containing imperfections classified and documented. The cells with various imperfections were tested to evaluate the imperfection potential impact on cell electrochemical performance. Evaluations were conducted on minicell, single cell and stack levels. On minicell level, pinhole, scratch, crack, contamination, and pop-out were investigated. We found: (1) none of the imperfections causes calamity type failure, (2) pinholes do not show measurable effect on minicell performance, (3) imperfection such as electrolyte abrasion, scratch, and pop out cause minicell potential to fluctuate by different degrees; the cells with such imperfections exhibit sensitivity of potential to high fuel utilization and “self healing” behavior. On single cell level we evaluated the effect of long crack and high population pinholes. The cell with a long crack does not show performance compromise at start. There is no potential fluctuation or sensitivity to high fuel utilization or catastrophic failure. The voltage degradation due to thermal cycle is slightly higher than normal cells. The cells with high population pinholes perform surprisingly as well as normal cells over a period of 3,500h. Even when subjected to cyclic load condition, the cells 4 show negligible degradation. Our cells appear to have “self immunization” feature which fends off the adversary effects of certain imperfections. Defects were also evaluated on stack level. Two stacks were made each with ten defect cells. The first stack was tested for 13,2000h under steady load condition while the second was tested for 9,000h under transient load conditions. We found: (1) voltage fluctuation and sensitivity to thermal cycle were not observed in contrast to minicell test, (2) of the various cracks examined, including longitudinal cracks, circumferential crack, crack near closed and open ends, none exhibited distinguishable impact on performance, (3) defect cells exhibited higher degradation rates on average under steady load condition; Individually some defect cells performed similarly or better than reference cells, (4) under steady load condition all the cells degrade monotonically with degradation rate increasing with time, (5) under cyclic (transient) load condition, both defect and reference cells exhibit complex dynamic behaviors, (6) fuel loss (leak) was measured occasionally for stack 1, the cells with crack showed the highest fuel loss increase, nevertheless, no correlation with performance degradation could be established with certainty, and (7) no catastrophic failure ever happened other than incremental degradation. Posttest inspection and microanalysis were carried out; the observations are summarized in what follows: (1) Electrolyte pinholes, some scratches and IC porosity became undetectable after testing. (2) The cathode covering the popout defects is intact without any cracking or delamination. (3) The scratch was covered by cathode in pristine state; Ni oxide or NiO-YSZ filled the space where electrolyte was missing. After >10,000h operation, the cathode that used to cover the scratch was missing but the size of the scratch remains unchanged; there is a fairly dense Ni oxide layer on top of the scratch. (4) All of the cracks remain their original dimensions. Current collector kept longitudinal cracks closed which mitigated the adversary effect of crack on cell performance/durability. (5) The crack at open end showed some deterioration manifested by a small oxidation zone in the vicinity of the crack. Wide spectrum of imaging techniques were surveyed and evaluated to detect tubular SOFC defects. Optical methods, with and without assistance of expression technique, were applied to detect all kinds of defects. Thermograph method in combination of CO2 leak, ultra-sound and electric potential was also extensively evaluated to detect surface and under-surface defects such as short circuit. Based on these works, laser camera has been selected to build the final QC machine vision inspection system. The Gocator laser profile sensor was setup to generate 2D surface intensity images of tubular SOFC surface which were analyzed with Sherlock machine vision software supplied by Teledyne Dalsa. The Gocator output was integrated with the Sherlock software and enabled live images to be imported by a Common Vision Blox driver. The Sherlock software was programmed to detect various surface defects from the surface intensity images generated by the Gocator. These measurements are subsequently used to make pass or fail decisions.

01 COAL, LIGNITE, AND PEAT↗

Real-time optical image processing techniques

Nonlinear real-time optical processing on spatial pulse frequency modulation has been pursued through the analysis, design, and fabrication of pulse frequency modulated halftone screens and the modification of micro-channel spatial light modulators (MSLMs). Micro-channel spatial light modulators are modified via the Fabry-Perot method to achieve the high gamma operation required for non-linear operation. Real-time nonlinear processing was performed using the halftone screen and MSLM. The experiments showed the effectiveness of the thresholding and also showed the needs of higher SBP for image processing. The Hughes LCLV has been characterized and found to yield high gamma (about 1.7) when operated in low frequency and low bias mode. Cascading of two LCLVs should also provide enough gamma for nonlinear processing. In this case, the SBP of the LCLV is sufficient but the uniformity of the LCLV needs improvement. These include image correlation, computer generation of holograms, pseudo-color image encoding for image enhancement, and associative-retrieval in neural processing. The discovery of the only known optical method for dynamic range compression of an input image in real-time by using GaAs photorefractive crystals is reported. Finally, a new architecture for non-linear multiple sensory, neural processing has been suggested.

Liu, Hua-Kuang↗

Application of digital image analysis techniques to antimisting fuel spray characterization

Pulsed ruby laser sheet illumination of the spray is used for the initial recording of data on very-high-resolution photographic film. The digitization of mosaic elements is effected with a vidicon and video digitizer whose output is stored in computer RAM memory for processing. Highly nonspherical elements and a broad range of drop diameters (8-2000 microns) resulting from the unusual rheological properties of the fuel-additive system are accommodated by the device configuration and algorithms. It is found that the generation of two-dimensional images by means of scattered light also eliminates errors resulting from variations in the index of refraction and from the submicron scattering sites that are often present within the modified fuel. No a priori information on the drop size distribution or on the system response to various drop sizes is required.

Fleeter, R.↗

Coronagraph Focal-Plane Phase Masks Based on Photonic Crystal Technology: Recent Progress and Observational Strategy

Photonic crystal, an artificial periodic nanostructure of refractive indices, is one of the attractive technologies for coronagraph focal-plane masks aiming at direct imaging and characterization of terrestrial extrasolar planets. We manufactured the eight-octant phase mask (8OPM) and the vector vortex mask (VVM) very precisely using the photonic crystal technology. Fully achromatic phase-mask coronagraphs can be realized by applying appropriate polarization filters to the masks. We carried out laboratory experiments of the polarization-filtered 8OPM coronagraph using the High-Contrast Imaging Testbed (HCIT), a state-of-the-art coronagraph simulator at the Jet Propulsion Laboratory (JPL). We report the experimental results of 10-8-level contrast across several wavelengths over 10% bandwidth around 800nm. In addition, we present future prospects and observational strategy for the photonic-crystal mask coronagraphs combined with differential imaging techniques to reach higher contrast. We proposed to apply a polarization-differential imaging (PDI) technique to the VVM coronagraph, in which we built a two-channel coronagraph using polarizing beam splitters to avoid a loss of intensity due to the polarization filters. We also proposed to apply an angular-differential imaging (ADI) technique to the 8OPM coronagraph. The 8OPM/ADI mode avoids an intensity loss due to a phase transition of the mask and provides a full field of view around central stars. We present results of preliminary laboratory demonstrations of the PDI and ADI observational modes with the phase-mask coronagraphs.

coronagraphy↗

Using Image Processing Techniques to Identify and Quantify Spatiotemporal Carbon Cycle Extremes

Rising atmospheric carbon dioxide due to human activities through fossil fuel emissions and land use changes have increased climate extremes such as heat waves and droughts that have led to and are expected to increase the occurrence of carbon cycle extremes. Carbon cycle extremes represent large anomalies in the carbon cycle that are associated with gains or losses in carbon uptake. Carbon cycle extremes could be continuous in space and time and cross political boundaries. Here, we present a methodology to identify large spatiotemporal extremes (STEs) in the terrestrial carbon cycle using image processing tools for feature detection. We characterized the STE events based on neighborhood structures that are three-dimensional adjacency matrices for the detection of spatiotemporal manifolds of carbon cycle extremes. We found that the area affected and carbon loss during negative carbon cycle extremes were consistent with continuous neighborhood structures. In the gross primary production data we used, 100 carbon cycle STEs accounted for more than 75% of all the negative carbon cycle extremes. This paper presents a comparative analysis of the magnitude of carbon cycle STEs and attribution of those STEs to climate drivers as a function of neighborhood structures for two observational datasets and an Earth system model simulation.

Sharma, Bharat↗

New Insights on the Structure of Electrochemically Deposited Lithium Metal and Its Solid Electrolyte Interphases via Cryogenic TEM

Lithium metal has been considered as the “holy grail” anode material for rechargeable batteries though the dendritic growth and low Coulombic efficiency (CE) have crippled its practical use for decades. Its high chemical reactivity and low stability make it difficult to explore the intrinsic chemical and physical properties of the electrochemically deposited lithium (EDLi) and its accompanied solid electrolyte interphase (SEI). To prevent the dendritic growth and enhance the electrochemical reversibility, it is crucial to understand the nano- and meso- structures of EDLi. However, Li metal is very sensitive to beam damage and has low contrast for commonly used characterization techniques such as electron microscopy. Inspired by biological imaging techniques, this work demonstrates the power of cryogenic (cryo)- electron microscopy to reveal the detailed structure of EDLi and the SEI composition at the nano scale while minimizing beam damage during imaging. Surprisingly, the results show that the nucleation dominated EDLi (five minutes at 0.5 mA cm-2) is amorphous while there is some crystalline LiF present in the SEI. The EDLi grown from various electrolytes with different additives exhibits distinctive surface properties. Consequently, these results highlight the importance of the SEI and its relationship with the CE. Our findings not only illustrate the capabilities of cryogenic microscopy for beam (thermal)-sensitive materials, but it yields crucial structural information of the EDLi evolution with and without electrolyte additives.

electrochemical deposition↗

The effects of chemical fixation on the cellular nanostructure

Chemical fixation is nearly indispensable in the biological sciences, especially in circumstances where cryo-fixation is not applicable. While universally employed for the preservation of cell organization, chemical fixatives often introduce artifacts that can confound identification of true structures. Since biological research is increasingly probing ever-finer details of the cellular architecture, it is critical to understand the nanoscale transformation of the cellular organization due to fixation both systematically and quantitatively. In this work, we employed Partial Wave Spectroscopic (PWS) Microscopy, a nanoscale sensitive and label-free live cell spectroscopic-imaging technique, to analyze the effects of the fixation process through three commonly used fixation protocols for cells in vitro. In each method investigated, we detected dramatic difference in both nuclear and cytoplasmic nanoarchitecture between live and fixed states. But significantly, despite the alterations in cellular nanoscale organizations after chemical fixation, the population differences in chromatin structure (e.g. induced by a specific chemotherapeutic agent) remains. In conclusion, we demonstrated that the nanoscale cellular arrangement observed in fixed cells was fundamentally divorced from that in live cells, thus the quantitative analysis is only meaningful on the population level. This finding highlights the importance of live cell imaging techniques with nanoscale sensitivity or cryo-fixation in the interrogation of cellular structure, to complement more traditional chemical fixation methods. - Highlights: • PWS was employed to monitor fixation process for the same cells in vitro. • Dramatic changes in cellular nanostructure were observed after fixation. • However, the population difference of chromatin structure remains after fixation.

60 APPLIED LIFE SCIENCES↗

Hyperdimensional Imaging Contrast Using an Optical Fiber

Fluorescence properties of a molecule can be used to study the structural and functional nature of biological processes. Physical properties, including fluorescence lifetime, emission spectrum, emission polarization, and others, help researchers probe a molecule, produce desired effects, and infer causes and consequences. Correlative imaging techniques such as hyperdimensional imaging microscopy (HDIM) combine the physical properties and biochemical states of a fluorophore. Here we present a fiber-based imaging system that can generate hyper-dimensional contrast by combining multiple fluorescence properties into a single fluorescence lifetime decay curve. Fluorescence lifetime imaging microscopy (FLIM) with controlled excitation polarization and temporally dispersed emission can generate a spectrally coded, polarization-filtered lifetime distribution for a pixel. This HDIM scheme generates a better contrast between different molecules than that from individual techniques. This setup uses only a single detector and is simpler to implement, modular, cost-efficient, and adaptable to any existing FLIM microscope. We present higher contrast data from Arabidopsis thaliana epidermal cells based on intrinsic anthocyanin emission properties under multiphoton excitation. This work lays the foundation for an alternative hyperdimensional imaging system and demonstrates that contrast-based imaging is useful to study cellular heterogeneity in biological samples.

47 OTHER INSTRUMENTATION↗

Whole-cell phase contrast imaging at the nanoscale using Fresnel Coherent Diffractive Imaging Tomography

X-ray tomography can provide structural information of whole cells in close to their native state. Radiation-induced damage, however, imposes a practical limit to image resolution, and as such, a choice between damage, image contrast, and image resolution must be made. New coherent diffractive imaging techniques, such Fresnel Coherent Diffractive Imaging (FCDI), allows quantitative phase information with exceptional dose efficiency, high contrast, and nano-scale resolution. Here we present three-dimensional quantitative images of a whole eukaryotic cell by FCDI at a spatial resolution below 70 nm with sufficient phase contrast to distinguish major cellular components. From our data, we estimate that the minimum dose required for a similar resolution is close to that predicted by the Rose criterion, considerably below accepted estimates of the maximum dose a frozen-hydrated cell can tolerate. Based on the dose efficiency, contrast, and resolution achieved, we expect this technique will find immediate applications in tomographic cellular characterisation.

MICROSCOPY↗

Identifying Indicators of Harmful Algal Blooms in Coastal Atacama Using Satellite Image Processing Techniques to Improve Industry and Authority Response

Over the past decade, Chile has experienced a significant rise in both the frequency and intensity of coastal Harmful Algal Blooms (HABs). These bloom events are a growing concern for the Atacama Region especially, with potential impacts on human health, aquaculture, and the environment. HABs are caused by an excess proliferation of microalgae, with certain algae species commonly found in Chilean HABs capable of producing toxins which can poison fish, toxify shellfish, and cause illness or death when ingested by humans. Collaborating with the Ministry of Health of Chile, Centro de Información de Recursos Naturales, the University of Atacama, and the Embassy of Chile’s Agricultural Office, this study identifies potential indicators of HABs in the Coastal Atacama Region using NASA Earth observations. Satellite imagery from the Moderate Resolution Imaging Spectroradiometer (MODIS) instrument onboard NASA’s Aqua satellite was used for the identification of chlorophyll-a which provides direct estimates of the algae pigment’s concentration in water bodies. In addition, the spatiotemporal patterns of several other parameters were examined to identify correlations with occurrences of HABs, including sea surface temperature and normalized fluorescence line height using Aqua MODIS, Normalized Difference Turbidity Index (NDTI) using Landsat 8, and ocean wind speed measurements from the NOAA Joint Polar Satellite System. Analysis of these patterns revealed hotspots of high chlorophyll-a concentrations from the years 2014 to 2022, the most major of which occurring in the coastal zones of Chañaral, Bahía Inglesa, and Huasco. Also, through the use of a similarity search conducted, the seasonal variation of these indicators was mapped to highlight areas with great likelihood of experiencing HABs in the future. The results can guide future efforts for in-situ water sampling, toxin analysis and assessment, and HAB monitoring and prevention.

Cody O'Ferrall↗

Imaging of surface acoustic waves on GaAs using 2D confocal Raman microscopy and atomic force microscopy

Surface acoustic wave devices have been fabricated on a GaAs (100) substrate to demonstrate the capability of 2D Raman microscopy as an imaging technique for acoustic waves on the surface of a piezoelectric substrate. Surface acoustic waves are generated using a two-port interdigitated transducer platform, which is modified to produce surface standing waves. We have derived an analytical model to relate Raman peak broadening to the near-surface strain field of the GaAs surface produced by the surface acoustic waves. Additionally, atomic force microscopy is used to confirm the presence of a standing acoustic wave, resolving a total vertical displacement of 3 nm at the antinode of the standing wave. Stress calculations are performed for both imaging techniques and are in good agreement, demonstrating the potential of this Raman analysis.

47 OTHER INSTRUMENTATION↗