Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “holistic”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

RFB Side Effects - Shunt Currents

The various models related to fluid flow, electrochemistry and shunt current, and their interactions are reviewed, and gaps identified in the development of flow battery holistic models. In a flow battery stack, the cells are electrically connected through the manifolds via the electrolyte. This results in shunt current through the electrolyte, which is a source of loss in the battery stack. This issue is examined in depth with a mathematical method of calculating shunt current distribution, the associated losses, and strategies to mitigate shunt current losses, along with the trade-offs.

Crawford, Aladsair J.↗

Network Optimization of the Electrosynthesis of Chemicals from CO2

Carbon dioxide electroreduction (ECO2R) is gaining attention due to its capacity to mitigate CO2 emissions while using electricity that would otherwise be curtailed. Its foreseeable industrial implementation requires of holistic methods to assess the technological and economic performance of ECO2R processes and integrate them in current chemical supply chains and power systems. Here, we combine techno-economic assessment and mathematical programming to find the optimal paths to electroreduce CO2 into valuable chemicals under variable electricity prices. The proposed approach is tested with a case study addressing the CO2 capture from flue gas or direct air and its electricity-powered reduction into carbon monoxide, formic acid or multi-carbon compounds. The results obtained demonstrate the ability of the framework to build ECO2R networks and provide operation profiles that respond to fluctuating electricity prices.

carbon dioxide↗

Identification of fuel cycle simulator functionalities for analysis of transition to a new fuel cycle

Dynamic fuel cycle simulation tools are intended to model holistic transient nuclear fuel cycle scenarios. As with all simulation tools, fuel cycle simulators require verification through unit tests, benchmark cases, and integral tests. Model validation is a vital aspect as well. Although compara-tive studies have been performed, there is no comprehensive unit test and benchmark library for fuel cycle simulator tools. The objective of this paper is to identify the must test functionalities of a fuel cycle simulator tool within the context of specific problems of interest to the Fuel Cycle Options Campaign within the U.S. Department of Energy s Office of Nuclear Energy. The approach in this paper identifies the features needed to cover the range of promising fuel cycle options identified in the DOE-NE Fuel Cycle Evaluation and Screening (E&S) and categorizes these features to facilitate prioritization. Features were categorized as essential functions, integrating features, and exemplary capabilities. One objective of this paper is to propose a library of unit tests applicable to each of the essential functions. Another underlying motivation for this paper is to encourage an international dialog on the functionalities and standard test methods for fuel cycle simulator tools.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Impact of thermal spectrum small modular reactors on performance of once-through nuclear fuel cycles with low-enriched uranium

Small modular reactors (SMRs) offer potential benefits, such as enhanced operational flexibility. However, it is vital to understand the holistic impact of SMRs on nuclear fuel cycle performance. The focus of this paper is the fuel cycle impacts of light water SMRs in a once-through fuel cycle with low-enriched uranium fuel. A key objective of this paper is to describe preliminary example reactor core physics and fuel cycle analyses conducted in support of the U.S. Department of Energy, Office of Nuclear Energy, Fuel Cycle Options Campaign. The hypothetical light water SMR example case considered in these preliminary scoping studies is a cartridge type one-batch core with slightly less than 5.0% enrichment. Challenges associated with SMRs include increased neutron leakage, fewer assemblies in the core (and therefore fewer degrees of freedom in the core design), complex enrichment and burnable absorber loadings, full power operation with inserted control rods, the potential for frequent load-following operation, and shortened core height. Each of these will impact the achievable discharge burnup in the reactor and the fuel cycle performance. This paper summarizes a list of the factors relevant to SMR fuel, core, and operation that will impact fuel cycle performance. The high-level issues identified and preliminary scoping calculations in this paper are intended to inform on potential fuel cycle impacts of one-batch thermal spectrum SMRs. In particular, this paper highlights the impact of increased neutron leakage and reduced number of batches on the achievable burnup of the reactor. Fuel cycle performance metrics for a hypothetical example SMR are compared with those for a conventional three-batch light water reactor in the following areas: nuclear waste management, environmental impact, and resource utilization. The metrics performance for such an SMR is degraded for the mass of spent nuclear fuel and high-level waste disposed of, mass of depleted uranium disposed of, land use per energy generated, and carbon emissions per energy generated. Finally, it is noted that the features of some SMR designs impact three main aspects of fuel cycle performance: (1) small cores which means high leakage (there is a radial and axial component), (2) no boron which means heterogeneous core and extensive use of control rods and BPs, and (3) single batch cores. But not all of the SMR designs have all of these traits. As a result, the approach used in this study is therefore a bounding case and not all SMRs may be affected to the same extent.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Thermal hydraulic model of the molten salt reactor experiment with the NEAMS system analysis module

System analysis codes have a long history of providing best-estimate and conservative safety analysis for both light water and advanced reactor technologies, including molten salt reactors. As interest continues to expand with advanced reactor concepts, system analysis codes will need revisions to accommodate the behavior of these technologies. Legacy system analysis codes will need to be updated to the latest numerical techniques to shorten execution time and increase the accuracy of results. One example of a modern system analysis code that already encompasses these characteristics is the System Analysis Module (SAM). One key objective of this paper was to review available information for system code modeling of the Molten Salt Reactor Experiment (MSRE) from sources in the open literature and collect the information from these open sources in one place for the first time. This supports the potential objective of developing an open specification for system code analysis for MSRE steady state and transients with and without reactor kinetics. Data from actual MSRE tests will serve as the basis for code-to-code comparison exercises, including the MSRE zero power physics tests, the fuel pump start-up and coast down tests, and the natural circulation transient. The objective is to produce a code-to-code benchmark with a standardized set of comparison problems, recognizing the limitations of the original data. To demonstrate an initial application of this objective and the usefulness of compiling this open data, two Molten Salt Reactor Experiment (MSRE)-related models were developed to evaluate SAM for liquid fueled molten salt reactors. One model was the SAM MSRE hydraulic mockup, which provided experimental data for pressure drop measurements. The second model was the complete MSRE primary loop. The MSRE primary loop model incorporated a fluoride salt fuel/coolant with heat transfer in both the core and heat exchanger. For both the hydraulic mockup and MSRE primary loop models, a holistic 1-D system description was built using open documentation, an open description that can be readily modified and applied for any system analysis code. SAM results for the pressure drop of the hydraulic mockup model were within 6% with measurements. Coolant temperatures for the primary loop model matched the expected axial change in temperature from historical calculations. Using alternative coolant properties obtained from the literature, corresponding to salts with different actinide contents, returned similar trends in core temperature profiles. A thermal hydraulic demonstration of a loss-of-flow transient showed the importance of coupling SAM thermal hydraulic analysis to neutronics. Here, this coupling is essential for simulating MSR transients with system analysis codes.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Data and Analytics to Inform Energy Retrofit of High Performance Buildings

Buildings consume more than one-third of the world?s primary energy. Reducing energy use in buildings with energy efficient technologies is feasible and also driven by energy policies such as energy benchmarking, disclosure, rating, and labeling in both the developed and developing countries. Current energy retrofits focus on the existing building stocks, especially older buildings, but the growing number of new high performance buildings built around the world raises a question that how these buildings perform and whether there are retrofit opportunities to further reduce their energy use. This is a new and unique problem for the building industry. Traditional energy audit or analysis methods are inadequate to look deep into the energy use of the high performance buildings. This study aims to tackle this problem with a new holistic approach powered by building performance data and analytics. First, three types of measured data are introduced, including the time series energy use, building systems operating conditions, and indoor and outdoor environmental parameters. An energy data model based on the ISO Standard 12655 is used to represent the energy use in buildings in a three-level hierarchy. Secondly, a suite of analytics were proposed to analyze energy use and to identify retrofit measures for high performance buildings. The data-driven analytics are based on monitored data at short time intervals, and cover three levels of analysis ? energy profiling, benchmarking and diagnostics. Thirdly, the analytics were applied to a high performance building in California to analyze its energy use and identify retrofit opportunities, including: (1) analyzing patterns of major energy end-use categories at various time scales, (2) benchmarking the whole building total energy use as well as major end-uses against its peers, (3) benchmarking the power usage effectiveness for the data center, which is the largest electricity consumer in this building, and (4) diagnosing HVAC equipment using detailed time-series operating data. Finally, a few energy efficiency measures were identified for retrofit, and their energy savings were estimated to be 20percent of the whole-building electricity consumption. Based on the analyses, the building manager took a few steps to improve the operation of fans, chillers, and data centers, which will lead to actual energy savings. This study demonstrated that there are energy retrofit opportunities for high performance buildings and detailed measured building performance data and analytics can help identify and estimate energy savings and to inform the decision making during the retrofit process. Challenges of data collection and analytics were also discussed to shape best practice of retrofitting high performance buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimizing Distributed Energy Resources and building retrofits with the strategic DER-CAModel

The pressuring need to reduce the import of fossil fuels as well as the need to dramatically reduce CO 2 emissions in Europe motivated the European Commission (EC) to implement several regulations directed to building owners. Most of these regulations focus on increasing the number of energy efficient buildings, both new and retrofitted, since retrofits play an important role in energy efficiency. Overall, this initiative results from the realization that buildings will have a significant impact in fulfilling the 20/20/20-goals of reducing the greenhouse gas emissions by 20%, increasing energy efficiency by 20%, and increasing the share of renewables to 20%, all by 2020. The Distributed Energy Resources Customer Adoption Model (DER-CAM) is an optimization tool used to support DER investment decisions, typically by minimizing total annual costs or CO 2 emissions while providing energy services to a given building or microgrid site. This document shows enhancements made to DER-CAM to consider building retrofit measures along with DER investment options. Specifically, building shell improvement options have been added to DER-CAM as alternative or complementary options to investments in other DER such as PV, solar thermal, combined heat and power, or energy storage. The extension of the mathematical formulation required by the new features introduced in DER-CAM is presented and the resulting model is demonstrated at an Austrian Campus building by comparing DER-CAM results with and without building shell improvement options. Strategic investment results are presented and compared to the observed investment decision at the test site. Results obtained considering building shell improvement options suggest an optimal weighted average U value of about 0.53 W/(m 2 K) for the test site. This result is approximately 25% higher than what is currently observed in the building, suggesting that the retrofits made in 2002 were not optimal. Furthermore, the results obtained with DER-CAM illustrate the complexity of interactions between DER and passive measure options, showcasing the need for a holistic optimization approach to effectively optimize energy costs and CO 2 emissions. Lastly, the simultaneous optimization of building shell improvements and DER investments enables building owners to take one step further towards nearly zero energy buildings (nZEB) or nearly zero carbon emission buildings (nZCEB), and therefore support the 20/20/20 goals.

25 ENERGY STORAGE↗

Modeling of HVAC operational faults in building performance simulation

Operational faults are common in the heating, ventilating, and air conditioning (HVAC) systems of existing buildings, leading to a decrease in energy efficiency and occupant comfort. Various fault detection and diagnostic methods have been developed to identify and analyze HVAC operational faults at the component or subsystem level. However, current methods lack a holistic approach to predicting the overall impacts of faults at the building level—an approach that adequately addresses the coupling between various operational components, the synchronized effect between simultaneous faults, and the dynamic nature of fault severity. This study introduces the novel development of a fault-modeling feature in EnergyPlus which fills in the knowledge gap left by previous studies. This paper presents the design and implementation of the new feature in EnergyPlus and discusses in detail the fault-modeling challenges faced. The new fault-modeling feature enables EnergyPlus to quantify the impacts of faults on building energy use and occupant comfort, thus supporting the decision making of timely fault corrections. Including actual building operational faults in energy models also improves the accuracy of the baseline model, which is critical in the measurement and verification of retrofit or commissioning projects. As an example, EnergyPlus version 8.6 was used to investigate the impacts of a number of typical operational faults in an office building across several U.S. climate zones. Finally, the results demonstrate that the faults have significant impacts on building energy performance as well as on occupant thermal comfort. Finally, the paper introduces future development plans for EnergyPlus fault-modeling capability.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Data analytics and optimization of an ice-based energy storage system for commercial buildings

Ice-based thermal energy storage (TES) systems can shift peak cooling demand and reduce operational energy costs (with time-of-use rates) in commercial buildings. The accurate prediction of the cooling load, and the optimal control strategy for managing the charging and discharging of a TES system, are two critical elements to improving system performance and achieving energy cost savings. This study utilizes data-driven analytics and modeling to holistically understand the operation of an ice–based TES system in a shopping mall, calculating the system’s performance using actual measured data from installed meters and sensors. Results show that there is significant savings potential when the current operating strategy is improved by appropriately scheduling the operation of each piece of equipment of the TES system, as well as by determining the amount of charging and discharging for each day. A novel optimal control strategy, determined by an optimization algorithm of Sequential Quadratic Programming, was developed to minimize the TES system’s operating costs. Three heuristic strategies were also investigated for comparison with our proposed strategy, and the results demonstrate the superiority of our method to the heuristic strategies in terms of total energy cost savings. Specifically, the optimal strategy yields energy costs of up to 11.3% per day and 9.3% per month compared with current operational strategies. A one-day-ahead hourly load prediction was also developed using machine learning algorithms, which facilitates the adoption of the developed data analytics and optimization of the control strategy in a real TES system operation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy efficiency evaluation of a stationary lithium-ion battery container storage system via electro-thermal modeling and detailed component analysis

Energy efficiency is a key performance indicator for battery storage systems. A detailed electro-thermal model of a stationary lithium-ion battery system is developed and an evaluation of its energy efficiency is conducted. The model offers a holistic approach to calculating conversion losses and auxiliary power consumption. Sub-models for battery rack, power electronics, thermal management as well as the control and monitoring components are developed and coupled to a comprehensive model. The simulation is parametrized based on a prototype 192 kWh system using lithium iron phosphate batteries connected to the low voltage grid. The key loss mechanisms are identified, thoroughly analyzed and modeled. Generic profiles featuring various system operation modes are evaluated to show the characteristics of stationary battery systems. Typically the losses in the power electronics outweigh the losses in the battery at low power operating points. The auxiliary power consumption dominates for low system utilization rates. For estimation of real-world performance, the grid applications Primary Control Reserve, Secondary Control Reserve and the storage of surplus photovoltaic power are evaluated. Conversion round-trip efficiency is in the range of 70-80%. Finally, overall system efficiency, which also considers system power consumption, is 8-13 percentage points lower for Primary Control Reserve and the photovoltaic-battery application. However, for Secondary Control Reserve, the total round-trip efficiency is found to be extremely low at 23% due to the low energy throughput of this application type.

25 ENERGY STORAGE↗

Translating climate change and heating system electrification impacts on building energy use to future greenhouse gas emissions and electric grid capacity requirements in California

Climate change and increased electrification of space and water heating in buildings can significantly affect future electricity demand and hourly demand profiles, which has implications for electric grid greenhouse gas emissions and capacity requirements. We use EnergyPlus to quantify building energy demand under historical and under several climate change projections of 32 kinds of building prototypes in 16 different climate zones of California and imposed these impacts on a year 2050 electric grid configuration by simulation in the Holistic Grid Resource Integration and Deployment (HIGRID) model. We find that climate change only prompted modest increases in grid resource capacity and negligible difference in greenhouse gas emissions since the additional electric load generally occurred during times with available renewable generation. Heating electrification, however, prompted a 30-40% reduction in greenhouse gas emissions but required significant grid resource capacity increases, due to the higher magnitude of load increases and lack of readily available renewable generation during the times when electrified heating loads occurred. Overall, this study translates climate change and electrification impacts to system-wide endpoint impacts on future electric grid configurations and highlights the complexities associated with translating building-level impacts to electric system-wide impacts.

54 ENVIRONMENTAL SCIENCES↗

Utilizing commercial heating, ventilating, and air conditioning systems to provide grid services: A review

The modern power grid faces multiple challenges due to an increase in the adoption of renewable generation, such as dynamically balancing supply and demand at different time scales. Demand side management in buildings plays a vital role in achieving this balance because buildings can provide grid services through a variety of building assets. However, the development of grid-interactive, efficient buildings is still in its infancy, and a systematic and holistic understanding of grid service delivery strategies in terms of energy efficiency, load shifting, load shedding and load modulating is still limited. This paper is a comprehensive review of the development and application of building-level control strategies for utilizing heating, ventilating, and air conditioning systems to provide grid services. These strategies have been investigated through numerical and experimental studies. Control algorithms, such as heuristic rule-based control and model-based control, have been used to enable the automatic control delivery of grid services. The advantages and disadvantages of the strategies are summarized and discussed. Finally, research trends are also identified, which include considering predicted mean vote-based and occupant-based thermal comfort, modeling of occupant behavior, integrating power grid operations with building control, and combining different demand flexibility modes in the control design.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Scalable probabilistic estimates of electric vehicle charging given observed driver behavior

To prepare for rapid growth in global electric vehicle adoption, grid and policy planners depend on detailed forecasts of future charging demand. In this paper we propose a novel holistic, scalable, probabilistic framework to produce large-scale estimates of electric vehicle charging load for long-term planning that capture real drivers’ charging patterns. Our framework captures the uncertainty and stochasticity in charging demand by taking a graphical modeling approach. It has three core elements: driver groups, charging segment choices, and charging session time and energy requirements. The framework uses hierarchical clustering to group drivers by their charging histories, capturing their heterogeneous behaviors and preferences across different segments or types of charging. The framework uses probabilistic mixture models for each driver group’s sessions to identify the unique charging behaviors observed within each segment. We illustrate its application with a large data set from California, profiling the charging patterns and unique driver clusters it identifies. Using the model knobs representing drivers’ battery capacities, behavior, and segment access we present scenarios for California’s charging demand in 2030 with 8 million passenger electric vehicles. Peak charging demand ranged from 3.3 to 8.7 GW across scenarios. Furthermore, each was calculated in under 45 s on a laptop computer.

33 ADVANCED PROPULSION SYSTEMS↗

Data-driven key performance indicators and datasets for building energy flexibility: A review and perspectives

Energy flexibility, through short-term demand-side management (DSM) and energy storage technologies, is now seen as a major key to balancing the fluctuating supply in different energy grids with the energy demand of buildings. This is especially important when considering the intermittent nature of ever-growing renewable energy production, as well as the increasing dynamics of electricity demand in buildings. This paper provides a holistic review of (1) data-driven energy flexibility key performance indicators (KPIs) for buildings in the operational phase and (2) open datasets that can be used for testing energy flexibility KPIs. The review identifies a total of 48 data-driven energy flexibility KPIs from 87 recent and relevant publications. These KPIs were categorized and analyzed according to their type, complexity, scope, key stakeholders, data requirement, baseline requirement, resolution, and popularity. Moreover, 330 building datasets were collected and evaluated. Of those, 16 were deemed adequate to feature building performing demand response or building-to-grid (B2G) services. The DSM strategy, building scope, grid type, control strategy, needed data features, and usability of these selected 16 datasets were analyzed. This review reveals future opportunities to address limitations in the existing literature: (1) developing new data-driven methodologies to specifically evaluate different energy flexibility strategies and B2G services of existing buildings; (2) developing baseline-free KPIs that could be calculated from easily accessible building sensors and meter data; (3) devoting non-engineering efforts to promote building energy flexibility, standardizing data-driven energy flexibility quantification and verification processes; and (4) curating and analyzing datasets with proper description for energy flexibility assessm.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Power System Operational Impacts of Electric Vehicle Dynamic Wireless Charging

The electrification of the transportation sector poses an opportunity for reducing greenhouse gas (GHG) emissions from passenger vehicles. Electric vehicle (EV) charging through dynamic wireless power transfer (DWPT), known as roadway electrification, could shift EV demand profiles to better coincide with renewable electricity generation. However, this would be a very large new load and few studies evaluate the regional impacts of DWPT charging in a power transmission system. This paper defines methods that address dataset generation for passenger vehicle trips and models to evaluate regional impacts for this emerging technology. Household vehicle miles traveled (VMT) data form localized EV demand profiles through discrete-event simulation. This data serves as exogenous inputs for a Production Cost Model (PCM) of a synthetic transmission system based on the Electric Reliability Council of Texas's (ERCOT) network. EV charging methods are compared for both a 2018 baseline generation mixture and a high-renewable generation case incorporating 20 GW of installed solar photovoltaic (PV) capacity. The PCM employs unit commitment and economic dispatch (UC&ED) models to compare financial, environmental, and grid reliability impacts from EV charging across passenger EV adoption levels. In-transit charging could reduce grid operational costs by as much as 1.49%, with up to $13.7B saved in annual vehicle operational costs for consumers compared to gas-powered vehicles. Health impacts analysis from power plant and vehicle tailpipe emissions from this study show net health benefits increase by 40% for in-transit charging coupled with high renewable generation. Renewable resources provide an avenue for cost-effective in-transit charging with reduced emissions. The combination of dataset generation and open-source power system modeling establish a foundation for the holistic evaluation of regional DWPT impacts.

dynamic wireless power transfer↗

A valuation framework for customers impacted by extreme temperature-related outages

Extreme temperature outages can lead to not just economic losses but also various non-energy impacts (NEI), such as increased mortality rates, property damage, and reduced productivity, due to significant degradation of indoor operating conditions caused by service disruptions. However, existing resilience assessment approaches lack specificity for extreme temperature conditions. They often overlook temperature-related mortality and neglect the customer characteristics and grid response in the calculation, despite the significant influence of these factors on NEI-related economic losses. This paper aims to address these gaps by introducing a comprehensive framework to estimate the impact of resilience enhancement not only on the direct economic losses incurred by customers but also on potential NEI, including mortality and the value of statistical life during extreme temperature-related outages. The proposed resilience valuation integrates customer characteristics and grid response variables based on a scalable grid simulation environment. This study adopts a holistic approach to quantify customer-oriented economic impacts, utilizing probabilistic loss scenarios that incorporate health-related factors and damage/loss models as a function of exposure for valuation. The proposed methodology is demonstrated through comparative resilient outage planning, using grid response models emulating a Texas weather zone during the 2021 winter storm Uri. The case study results show that enhanced outage planning with hardened infrastructure can improve the system resilience and thereby reduce the relative risk of mortality by 16% and save the total costs related to non-energy impacts by 74%. In conclusion, these findings underscore the efficacy of the framework by assessing the financial implications of each case, providing valuable insights for decision-makers and stakeholders involved in extreme-weather related resilience planning for risk management and mitigation strategies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Wave energy in season: a comparative approach to feasibility of seasonal deployments for remote coastal communities

Remote coastal communities, which could be early adopters of wave energy projects, have concerns over costs, conflicts, and potential risks of development. Designers and developers are challenged to address these community concerns as they continue to develop wave energy technologies. One potential means of reducing costs, conflicts, and risks, especially for demonstration and pilot-scale projects, could be planning a deployment that operates for only a portion of the year—a seasonal deployment. Here, in this paper, we examine the impacts of a seasonal deployment in terms of cost, electricity production, operations and maintenance, environmental impacts, and community benefits. We take a holistic, comparative approach to feasibility that can be replicated for other comparative studies. We estimate electricity production using a point absorber WEC modeled near Sitka, AK, USA and optimized for the given sea conditions. We determine that, for remote community sized projects, seasonal deployments could result in small cost savings (less than 10 %), but larger decreases in annual energy production (around 30 % for our case study area). Seasonal deployments could be preferable in places with seasonal energy needs, if failures and device access become a major hindrance to wave energy technology development, or as a cautionary approach to introducing new technology to the oceans. We also determine that a highly seasonal wave resource is not necessarily a requirement for seasonal deployments to be considered. Seasonal deployments are an alternative to year-round deployments that can be considered in places where marine spatial conflict is a seasonal concern.

WEC optimizations↗

Observational study of relationships between entrainment rate, homogeneity of mixing, and cloud droplet relative dispersion

The entrainment–mixing process is key to the cloud’s dynamical and microphysical processes. However, to the best of our knowledge, no study has quantitatively linked entrainment rate and homogeneity of mixing. Additionally, their combined effects on cloud droplet relative dispersion and physical mechanisms are even more unclear. This study analyzed the aircraft measurements of cumulus clouds collected in the Holistic Interactions of Shallow Clouds, Aerosols, and Land-Ecosystems field campaign to identify these relationships. The relationship between the entrainment rate and homogeneous mixing degree was found to be moderately positive, and the underlying mechanisms related to mixing and evaporation time scales and environmental relative humidity were explored. The relationship between relative dispersion and entrainment rate changes from positive to negative with increasing entrainment rate, depending on the dominance of evaporation of large or small droplets. The relative dispersion first increases and then decreases with increasing homogeneous mixing degree, validating the results of previous model simulations. Further, the results shed new light on understanding the interactions between cloud microphysics and cloud dynamics through turbulent entrainment and mixing processes.

54 ENVIRONMENTAL SCIENCES↗