Performance and Costs of Ductless Heat Pumps in Marine-Climate High-Performance Homes Habitat for Humanity The Woods

The Washington State University (WSU) Energy Program's Building America (BA) team conducted a case study of a high-performance affordable housing community: The Woods (Figure 1). This BA effort is part of a larger-scale study of 30 homes funded from 2013-2016 by Tacoma Public Utilities (TPU) and the Bonneville Power Administration. The Woods is a Habitat for Humanity (HFH) community of homes certified by ENERGY STAR Homes Northwest (ESHNW); the community is in the marine climate of Tacoma/Pierce County, Washington. This research report builds on an earlier preliminary draft 2014 BA report and includes significant billing analysis and cost-effectiveness research from a collaborative and ongoing DHP research effort for TPU and the Bonneville Power Administration. This final BA report focuses on the results of field testing, modeling, and monitoring of ductless mini-split heat pump hybrid heating systems in seven homes built and first occupied at various times between September 2013 and October 2014. The report also provides WSU documentation of high-performance home observations, lessons learned, and stakeholder recommendations for builders of affordable high-performance housing. The research goal of the U.S. Department of Energy's BA research team Building America Partnership for Improved Residential Construction was to compare a ductless heat pump (DHP) hybrid system (DHP in common area/electric resistance [ER] in bedrooms) to an all-electric zonal ER system in high-performance single-family affordable housing. This effort included assessing the costs and benefits of a DHP/ER hybrid system located in the main living area to offset the primary heating demand of zonal ER heaters in the bedroom zones and comparing these findings to data from of new affordable single-family housing in Washington State. This report includes: (1) Measured indoor and outdoor temperatures and relative humidity (RH) in the homes. (2) Field testing results of heating, ventilating, and air-conditioning equipment; ventilation system airflows; building envelope tightness; lighting, appliance, and other input data required for preliminary Building Energy Optimization (BEopt) modeling; and ENERGY STAR field verification (3) BEopt modeling results compared to measured energy use. (4) A comparison of the space heat energy consumption of a DHP/ER hybrid heating system and a traditional zonal ER heating system installed in the same home. This comparison is made by implementing a series of weekly "flip-flop tests" (referred to here as "switchback" tests per TPU) to compare space heating, temperature, and RH in zonal ER heating mode with a DHP/ER mode as discussed in the Building America Test Plan (Lubliner 2010a). (5) Cost data from HFH and other sources related to building efficiency measures focusing on the DHP/ER hybrid heating system. (6) An evaluation of the thermal performance and cost benefit of DHP/ER hybrid heating systems in these high-performance homes employing life cycle cost analysis for energy code policy and monthly cash flow analysis of HFH homeowners. (7) Post-monitoring occupant survey results. The report also provides the following stakeholder findings and recommendations: (1) DHP single-head systems at The Woods are cost-effective to new homebuyers of these high-performance all-electric homes. (2) Stakeholder education is needed on design, inspection, and commissioning; documentation is needed for heat recovery ventilation (HRV) and from ENERGY STAR builders, verifiers, and inspectors to help ensure that the houses meet the goal of "build tight, ventilate right." (3) A code gap in inspection and enforcement was identified that should be addressed by: (3a) Improving the fire marshal's approach to sprinkler attic piping freeze protection; (3b) Improving the maintenance of ceiling insulation continuity; and (3c) Educating the local building inspector on attic insulation inspection concerns that allow for maximizing design improveme...

affordable housing↗

Air-to-Water Heat Pumps With Radiant Delivery in Low-Load Homes

Space conditioning represents nearly 50% of average residential household energy consumption, highlighting the need to identify alternative cost-effective, energy-efficient cooling and heating strategies. As homes are better built, there is an increasing need for strategies that are particularly well suited for high performance, low load homes. ARBI researchers worked with two test homes in hot-dry climates to evaluate the in-situ performance of air-to-water heat pump systems, an energy efficient space conditioning solution designed to cost-effectively provide comfort in homes with efficient, safe, and durable operation. Two monitoring projects of test houses in hot-dry climates were initiated in 2010 to test this system. Both systems were fully instrumented and have been monitored over one year to capture complete performance data over the cooling and heating seasons. Results are used to quantify energy savings, cost-effectiveness, and system performance using different operating modes and strategies. A calibrated TRNSYS model was developed and used to evaluate performance in various climate regions. This strategy is most effective in tight, insulated homes with high levels of thermal mass (i.e. exposed slab floors).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance Efficient Multiresilience Using Checkpoint Recovery in Iterative Algorithms

In this paper, we address the design challenge of building multiresilient iterative high-performance computing (HPC) applications. Multiresilience in HPC applications is the ability to tolerate and maintain forward progress in the presence of both soft errors and process failures. We address the challenge by proposing performance models which are useful to design performance efficient and resilient iterative applications. The models consider the interaction between soft error and process failure resilience solutions. We experimented with a linear solver application with two distinct kinds of soft error detectors: one detector has high overhead and high accuracy, whereas the second has low overhead and low accuracy. We show how both can be leveraged for verifying the integrity of checkpointed state used to recover from both soft errors and process failures. Our results show the performance efficiency and resiliency benefit of employing the low overhead detector with high frequency within the checkpoint interval, so that timely soft error recovery can take place, resulting in less re-computed work.

Ashraf, Rizwan↗

Automated Fabrication Technologies for High Performance Polymer Composites

New fabrication technologies are being exploited for building high graphite-fiber-reinforced composite structure. Stitched fiber preforms and resin film infusion have been successfully demonstrated for large, composite wing structures. Other automatic processes being developed include automated placement of tacky, drapable epoxy towpreg, automated heated head placement of consolidated ribbon/tape, and vacuum-assisted resin transfer molding. These methods have the potential to yield low cost high performance structures by fabricating composite structures to net shape out-of-autoclave.

Shuart , M. J.↗

Community-Wide Zero Energy Ready Home Standard

This report outlines the steps a developer can take when creating and implementing high performance standards such as the U.S. Department of Energy’s (DOE’s) Zero Energy Ready Home (ZERH) standards on a community-wide scale. The report also describes the specific examples of how this process is underway in the Stapleton community in Denver, Colorado, by the developer Forest City.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

DOE Zero Energy Ready Homes

This article describes the U.S. Department of Energy's Zero Energy Ready Home Program and Housing Innovation Awards. Since 2013, builders around the country have certified over 1,170 homes to the high performance criteria of the DOE Zero Energy Ready Home program. Each year DOE recognizes the best innovators among this group with the DOE Housing Innovation Awards. 2017 winners will be announced at an awards event taking place at the Energy & Environmental Building Alliance (EEBA) high-performance home summit October 10-12, 2017, in Atlanta, Georgia. Twenty-five builders are expected to take home awards and grand award winners in each of the five competition categories will be revealed at the conference. Participating builders represent every climate zone in the country and DOE Zero Energy Ready labeled homes can be found in 34 states. Homes represent the full spectrum of the U.S. construction industry, from affordable to production to custom homes and from single-family detached to duplexes and up to five-story multifamily buildings as well as some retrofit projects have also met the criteria. Every DOE ZER certified home is certified through the ENERGY STAR Certified Homes (Version 3.0, revision 8) program and the U.S. Environmental Protection Agency’s Indoor airPLUS program. Each home must meet the hot water distribution requirements of the EPA’s WaterSense program and the insulation requirements of the 2012 International Energy Conservation Code. If the home has HVAC ducts, they must be installed within the conditioned space of the home. Appliances, exhaust fans, ceiling fans, and most of the lighting should be ENERGY STAR qualified. The DOE Zero Energy Ready Home program also requires homes to have solar electric panels installed or at a minimum to have the conduit and electrical panel space in place for future PV installation, if the home is in a location appropriate for solar power. Homes are constructed with enough energy efficiency built in so that, with a reasonable amount of solar PV panels (i.e., small enough to fit comfortably on the roof), the home could produce enough of its own power to equal the power it uses in a year.

U.S. Department of Energy Building Technologies Pr↗

Raising the Bar in High Performance Laboratory Design

Laboratory facilities are expensive to build and operate, they consume energy at high rates compared to other types of buildings, and modifications are frequently required to accommodate ever-changing research activities. PNNL sought ways to address these issues in the design and construction of a 14,700 sq. ft. new laboratory building. To improve adaptability to change a high roof structure was used that allows raising the ceiling when needed with minimal disruption to installed HVAC and electrical utilities. Also, HVAC equipment was located on a mezzanine above the central corridor rather than above ceilings. This eliminates the need for maintenance personnel to routinely access lab spaces, reducing disruption to research staff and improving maintenance access. To improve the reliability of operations while reducing energy consumption, heat pipe heat recovery with evaporative cooling, zoned heating/cooling coils, high-efficiency condensing boilers, district cooling, VAV fume hoods, DDC controls, energy use monitoring, and implementation of the US Department of Energy’s Guiding Principles for Federal Leadership in Sustainable Buildings were all used. The energy model developed during design projected energy use at 2,840 MBtu/yr, a 13.5% savings over ASHRAE Standard 90.1-2010. The first full year of operation resulted in actual energy use of 2,661 MBtu, a savings of 19% over Standard 90.1. As a result of the project design’s demonstrated success, these strategies will be incorporated into a significantly larger (125,000 sq ft), $65 million lab facility to be constructed on the PNNL campus in 2020.

Scott, Jeffery M.↗

ResStock: Annual Baseline Results with Component Loads

The ResStock Analysis Tool was developed by NREL with support from the U.S. Department of Energy to provide a new approach to large-scale residential analysis by combining large public and private data sources, statistical sampling, detailed sub hourly building simulations, and high-performance computing. This combination achieves unprecedented granularity and accuracy in modeling the diversity of the housing stock and the distributional impacts of building technologies in different communities. The annual baseline energy results from a national-scale ResStock run use typical meteorological year 3 (TMY3) files for energy simulations. Results include heating and cooling loads for individual components of each building. Component loads describe the heating/cooling load that can be attributed to specific elements of a home, such as heat transfer through walls or internal gains. Additionally, these results include the standard ResStock outputs for housing characteristics and numerous energy outputs by end-use and fuel. A snapshot of the ResStock version used to produce this data, including a configuration file for the run can be found using the Source Code resource link.

Array↗

High Performance Circulator Pump Demonstration

In commercial buildings, smaller circulator pumps are typically overlooked for energy efficiency upgrades due to their smaller size (typically less than 2.5 hp) and due to the lack of commercially available products that can simultaneously provide a combination of integrated controls and variable speed operation that is required to achieve acceptable energy savings and life cycle cost effectiveness. This General Services Administration (GSA) Green Proving Ground (GPG) project assessed the performance of a new high performance circulator pump (HPCP) at one heating hot water (HHW) application and two domestic hot water (DHW) application at the Denver Federal Center in Denver, Colorado.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Measure Guideline: Deep Energy Enclosure Retrofit for Interior Insulation of Masonry Walls and Flat Roofs

Measure Guideline: Deep Energy Enclosure Retrofit for Zero Energy Ready House Flat Roofs BSC TO5 Task 7.4 Deep Energy Enclosure Retrofit (DEER) for Interior Insulation of Masonry Walls Lawrence, MA 01840 This Measure Guideline describes a deep energy enclosure retrofit solution for insulating mass masonry buildings from the interior. It describes the retrofit assembly, technical details, and installation sequence for retrofitting masonry walls. Interior insulation of masonry retrofits might adversely affect the durability of the wall. This guideline includes a review of decision criteria pertinent to retrofitting masonry walls from the interior and the possible risk of freeze-thaw damage. This Measure Guideline is intended to support contractors who are implementing an interior insulation-based high-performance enclosure retrofit for masonry buildings and designers who are looking to design such retrofits. It may also be helpful to building owners who wish to learn more about strategies that are available for deep energy enclosure retrofit of masonry residential buildings on the interior. This Measure Guideline is important to the high-performance retrofit industry because the solution described here provides an opportunity to retrofit masonry buildings with ambitious energy performance goals by insulating them from the interior without disturbing their exterior appearance. BSC TO5 Task 7.4 Deep Energy Enclosure Retrofit (DEER) for Zero Energy Ready House (ZERH) Flat Roofs House Jamaica Plain, MA 02130 This Measure Guideline provides design and construction information for a deep energy enclosure retrofit solution of a flat roof assembly. It describes the strategies and procedures for an exterior retrofit of a flat wood-framed roof with brick masonry exterior walls using exterior and interior (framing cavity) insulation. The approach supported in this guide could also be adapted for use with flat wood-framed roofs with wood-framed exterior walls. Designers, contractors, and building code officials will benefit from the information contained in this Measure Guideline. The guide may also be helpful to building owners who wish to learn more about strategies for deep energy enclosure retrofit of flat roofs. This Measure Guideline is important to the high-performance retrofit industry because it demonstrates techniques for retrofitting flat roofs from the exterior, which is less disruptive to the living space and allows the structure to remain occupied during the project. It also illustrates a solution for preparing homes to become zero energy ready.

Array↗

Commercial Building Energy Asset Rating Program -- Market Research

Under contract to Pacific Northwest National Laboratory, HaydenTanner, LLC conducted an in-depth analysis of the potential market value of a commercial building energy asset rating program for the U.S. Department of Energy (DOE) Office of Energy Efficiency and Renewable Energy. The market research objectives were to: (1) Evaluate market interest and need for a program and tool to offer asset rating and rapidly identify potential energy efficiency measures for the commercial building sector. (2) Identify key input variables and asset rating outputs that would facilitate increased investment in energy efficiency. (3) Assess best practices and lessons learned from existing national and international energy rating programs. (4) Identify core messaging to motivate owners, investors, financiers, and others in the real estate sector to adopt a voluntary asset rating program and, as a consequence, deploy high-performance strategies and technologies across new and existing buildings. (5) Identify leverage factors and incentives that facilitate increased investment in these buildings. To meet these objectives, work consisted of a review of the relevant literature, examination of existing and emergent asset and operational rating systems, interviews with industry stakeholders, and an evaluation of the value implication of an asset label on asset valuation. This report documents the analysis methodology and findings, conclusion, and recommendations. Its intent is to support and inform the DOE Office of Energy Efficiency and Renewable Energy on the market need and potential value impacts of an asset labeling and diagnostic tool to encourage high-performance new buildings and building efficiency retrofit projects.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High Performance (R-10/inch) Clay-Cellulose-Silica Nanopore Insulation Board For New and Retrofit Buildings (Final Scientific Report)

The objective of Liatris’s 3-year DOE BENEFIT project was to develop and validate a high-performance, lightweight, aerogel-based insulation board of ≥R-10/inch at a cost of ≤$\$$1.50 per board foot using non-flammable inorganic nanocomposites. We have summarized each yearly goal below: Year 1 – Ambient dried inorganic/organic nanocomposite, R-6/inch Year 2 – Processing efficiency and cost down, R-8/inch at $\$$2.0/board-ft Year 3 – Scale up to continuous, pilot production of R-10 at ≤ $\$$1.50/board-ft Over the course of the project period, Liatris has successfully met or exceeded all of the goals outlined above. The project scope over 3 years was extensive, covering method development of ambient dried silica aerogels in Budget Period 1, process formulation and R-value improvement in Budget Period 2, and composite scale up with corporate partners in Budget Period 3. Over the course of the project Liatris has been able to progressively improve the thermal resistance properties from about R-6/in to > R-11/in, 2-3X the performance of conventional insulation products.

36 MATERIALS SCIENCE↗

NREL Helps Greensburg Set the Model for Green Communities (Fact Sheet)

After a massive tornado destroyed or severely damaged 95% of Greensburg, Kansas on May 4, 2007, key leaders in Greensburg and Kansas made a crucial decision not just to rebuild, but to remake the town as a model sustainable rural community. To help achieve that goal, experts from the U.S. Department of Energy (DOE) and the National Renewable Energy Laboratory (NREL) arrived in Greensburg in June2007.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Retrofit of a Multifamily Mass Masonry Building in New England

Merrimack Valley Habitat for Humanity (MVHfH) has partnered with Building Science Corporation to provide high performance affordable housing for 10 families in the retrofit of an existing brick building (a former convent) into condominiums. The research performed for this project provides information regarding advanced retrofit packages for multi-family masonry buildings in Cold climates. In particular, this project demonstrates safe, durable, and cost-effective solutions that will potentially benefit millions of multi-family brick buildings throughout the East Coast and Midwest (Cold climates). The retrofit packages provide insight on the opportunities for and constraints on retrofitting multifamily buildings with ambitious energy performance goals but a limited budget. The condominium conversion project will contribute to several areas of research on enclosures, space conditioning, and water heating. Enclosure items include insulation of mass masonry building on the interior, airtightness of these types of retrofits, multi-unit building compartmentalization, window selection, and roof insulation strategies. Mechanical system items include combined hydronic and space heating systems with hydronic distribution in small (low load) units, and ventilation system retrofits for multifamily buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Retrofit of a MultiFamily Mass Masonry Building in New England

Merrimack Valley Habitat for Humanity (MVHfH) has partnered with Building Science Corporation to provide high performance affordable housing for 10 families in the retrofit of an existing brick building (a former convent) into condominiums. The research performed for this project provides information regarding advanced retrofit packages for multi-family masonry buildings in Cold climates. In particular, this project demonstrates safe, durable, and cost-effective solutions that will potentially benefit millions of multi-family brick buildings throughout the East Coast and Midwest (Cold climates). The retrofit packages provide insight on the opportunities for and constraints on retrofitting multifamily buildings with ambitious energy performance goals but a limited budget. The condominium conversion project will contribute to several areas of research on enclosures, space conditioning, and water heating. Enclosure items include insulation of mass masonry building on the interior, airtightness of these types of retrofits, multi-unit building compartmentalization, window selection, and roof insulation strategies. Mechanical system items include combined hydronic and space heating systems with hydronic distribution in small (low load) units, and ventilation system retrofits for multifamily buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Integration of Open-Source URBANopt and Dragonfly Energy Modeling Capabilities into Practitioner Workflows for District-Scale Planning and Design

High-performance districts and communities offer opportunities for reducing energy use, emissions, and costs, and can be instrumental in helping cities achieve their climate goals. The design of such communities requires identification of opportunities early on and their re-evaluation throughout the planning process. There is a need for energy modeling tools that connect 3D Computer-Aided Design (CAD) platforms to simulation engines, enabling detailed energy analysis of districts within the workflows and tools used by practitioners. This paper introduces the Dragonfly and URBANoptTM combined toolset that supports the creation of urban models from a range of geometry formats typically used by designers and planners, and provides an integrated pathway to simulate district-scale energy systems. The toolset is piloted by a global architecture and master planning firm to evaluate several key urban-scale technical questions for the design of a district in Chicago. The findings indicate that, while energy savings can be achieved through traditional architectural studies and enhancements to individual building efficiency, the modeling toolset helps identify additional savings and insights that can be achieved when considering district-scale energy systems. Finally, this study demonstrates how the Dragonfly/URBANopt toolset can integrate with master planning workflows, thereby enabling an iterative performance-based design process.