Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “heat map”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Extending the Heat Index

The Heat Index is a widely used measure of apparent temperature that accounts for the effects of humidity using Steadman’s model of human thermoregulation. Steadman’s model, however, gives unphysical results when the air is too hot and humid or too cold and dry, leading to an undefined Heat Index. For example, at a relative humidity of 80%, the Heat Index is only defined for temperatures in the range of 288-304 K (59-88 degrees Fahrenheit). Here, Steadman’s thermoregulation model is extended to define the Heat Index for all combinations of temperature and humidity, allowing for an assessment of Earth’s future habitability. The extended Heat Index can be mapped onto physiological responses of an idealized human, such as heat exhaustion, heat stroke, and even heat death, providing an indication of regional health outcomes for different degrees of global warming.

54 ENVIRONMENTAL SCIENCES↗

Convective Enhancement of Icing Roughness Elements in Stagnation Region Flows

To improve existing ice accretion simulation codes, more data regarding ice roughness and its effects on convective heat transfer are required. To build on existing research on this topic, this study used the Vertical Icing Studies Tunnel (VIST) at NASA Glenn Research to model realistic ice roughness in the stagnation region of a NACA 0012 airfoil. Using the VIST, a test plate representing the leading 2% chord of the airfoil was subjected to flows of 7.62 m/s (25 ft/s), 12.19 m/s (40 ft/s), and 16.76 m/s (55 ft/s). The test plate was fitted with 3 surfaces, each with a different representation of ice roughness: 1) a control surface with no ice roughness, 2) a surface with ice roughness with element height scaled by 10x and streamwise rough zone width from the stagnation point scaled by 10x, and 3) a surface with ice roughness with element height scaled by 10x and streamwise rough zone width from the stagnation point scaled by 25x. Temperature data from the tests were recorded using an infrared camera and thermocouples imbedded in the test plate. From the temperature data, a convective heat transfer coefficient map was created for each case. Additional testing was also performed to validate the VIST's flow quality. These tests included five-hole probe and hot-wire probe velocity traces to provide flow visualization and to study boundary layer formation on the various test surfaces. The knowledge gained during the experiments will help improve ice accretion codes by providing heat transfer coefficient validation data and by providing flow visualization data helping understand current and future experiments performed in the VIST.

Icing↗

Local convection characteristics of inline arrangement of Kagome-shaped unit cells in a square duct

Transient liquid crystal thermography experiments have been conducted to determine detailed convective heat transfer coefficients at the endwalls of lattice-frame configurations based on Kagome-shaped unit cells. Kagome unit cells with porosity of 0.88 were arranged in an inline manner, where two such arrangements were studied. In the first arrangement, a total of ten unit cells were placed next to each other along the streamwise direction resulting in a continuous configuration. In the 2nd arrangement, alternate unit cells from the continuous configuration were dropped, resulting in a discrete configuration which featured a total of 5 Kagome unit cells. Due to the asymmetric nature of the strut connections within the unit cell, the convective heat transfer coefficient maps were determined for the two opposite walls where the struts meet the endwalls. Transient liquid crystal experiments were conducted for Reynolds number ranging between 10,000 and 30,000. Here, the study was focused on the developing nature of flow along the streamwise direction and the local convection characteristics for continuous and discrete arrangement of unit cells. For the continuous configuration, the Nusselt number ratios (N u /Nu 0 ) varied between 3.15–3.46 and 2.75–2.89 for the two walls A and B, respectively. For the discrete configuration, convective heat transfer coefficients varied between 2.56–2.71 and 2.09–2.40 for the two walls. Kagome unit cells have the potential to be fabricated through inexpensive manufacturing routes such as wire-woven method and these unit cells find their applications in the areas which require different heat transfer levels on opposite walls.

Kagome↗

Heat Transfer in a Superelliptic Transition Duct

Local heat transfer measurements were experimentally mapped using a transient liquid-crystal heat transfer technique on the surface of a circular-to-rectangular transition duct. The transition duct had a length-to-diameter ratio of 1.5 and an exit-plane aspect ratio of 3. The crosssectional geometry was defined by the equation of a superellipse. The cross-sectional area was the same at the inlet and exit but varied up to 15 percent higher through the transition. The duct was preheated to a uniform temperature (nominally 64 C) before allowing room temperature air to be suddenly drawn through it. As the surface cooled, the resulting isothermal contours on the duct surface were revealed using a surface coating of thermochromic liquid crystals that display distinctive colors at particular temperatures. A video record was made of the surface temperature and time data for all points on the duct surfaces during each test. Using this surface temperature-time data together with the temperature of the air flowing through the model and the initial temperature of the model wall, the heat transfer coefficient was calculated by employing the classic one-dimensional, semi-infinite wall heat transfer conduction model. Test results are reported for inlet diameter-based Reynolds numbers ranging from 0.4x106 to 2.4x106 and two grid-generated freestream turbulence intensities of about 1 percent, which is typical of wind tunnels, and up to 16 percent, which may be more typical of real engine conditions.

Poinsatte, Philip↗

Spacesuit Water Membrane Evaporator Development for Lunar Missions

For future lunar extra-vehicular activities (EVA), one method under consideration for rejecting crew and electronics heat involves evaporating water through a hydrophobic, porous Teflon membrane. A Spacesuit Water Membrane Evaporator (SWME) prototype using the Teflon membrane was tested successfully by Ungar and Thomas (2001) with predicted performance matching test data well. The above referenced work laid the foundation for the design of the SWME development unit, which is being considered for service in the Constellation System Spacesuit Element (CSSE) Portable Life Support System (PLSS). Multiple PLSS SWME configurations were considered on the basis of thermal performance, mass, volume, and performance and manufacturing risk. All configurations were a variation of an alternating concentric water and vapor channel configuration or a stack of alternating rectangular water and vapor channels. Supporting thermal performance trades mapped maximum SWME heat rejection as a function of water channel thickness, vapor channel thickness, channel length, number of water channels, porosity of the membrane structural support, and backpressure valve throat area. Preliminary designs of each configuration were developed to determine total mass and volume as well as to understand manufacturing issues. Review of configurations led to the selection of a concentric annulus configuration that meets the requirements of 800 watts (W) of heat rejection. Detailed design of the SWME development unit will be followed by fabrication of a prototype test unit, with thermal testing expected to start in 2008.

Vogel, Matt R.↗

Does Marine Surface Tension Have Global Biogeography? Addition for the OCEANFILMS Package

We apply principles of Gibbs phase plane chemistry across the entire ocean-atmosphere interface to investigate aerosol generation and geophysical transfer issues. Marine surface tension differences comprise a tangential pressure field controlling trace gas fluxes, primary organic inputs, and sea spray salt injections, in addition to heat and momentum fluxes. Mapping follows from the organic microlayer composition, now represented in ocean system models. Organic functional variations drive the microforcing, leading to (1) reduced turbulence and (by extension) laminar gas-energy diffusion; plus (2) altered bubble film mass emission into the boundary layer. Interfacial chemical behaviors are, therefore, closely reviewed as the background. We focus on phase transitions among two dimensional “solid, liquid, and gaseous” states serving as elasticity indicators. From the pool of dissolved organic carbon (DOC) only proteins and lipids appear to occupy significant atmospheric interfacial areas. The literature suggests albumin and stearic acid as the best proxies, and we distribute them through ecodynamic simulation. Consensus bulk distributions are obtained to control their adsorptive equilibria. We devise parameterizations for both the planar free energy and equation of state, relating excess coverage to the surface pressure and its modulus. Constant settings for the molecular surrogates are drawn from laboratory study and successfully reproduce surfactant solid-to-gas occurrence in compression experiments. Since DOC functionality measurements are rare, we group them into super-ecological province tables to verify aqueous concentration estimates. Outputs are then fed into a coverage, tension, elasticity code. The resulting two dimensional pressure contours cross a critical range for the regulation of precursor piston velocity, bubble breakage, and primary aerosol sources plus ripple damping. Concepts extend the water-air adsorption theory currently embodied in our OCEANFILMS aerosol emissions package, and the two approaches could be inserted into Earth System Models together. Uncertainties in the logic include kinetic and thermochemical factors operating at multiple scales.

54 ENVIRONMENTAL SCIENCES↗

Arcjet Ablation of Stony and Iron Meteorites

A test campaign was conducted placing meteorites in the 60 MW plasma Arcjet Interaction Heating Facility at NASA Ames Research Center, with the aim to achieve flight-relevant conditions for asteroid impacts in Earth's atmosphere and to provide insight into how meteoritic materials respond to extreme entry heating environments. The test conditions at heat flux of 4000 W/m2 and 140 kPa stagnation pressure are comparable to those experienced by a 30-meter diameter asteroid moving at 20 km/s velocity at 65 km altitude in the Earth's atmosphere. Test objects were a stony type H5 ordinary chondrite (Tamdakht) and an iron type IAB-MG meteorite (Campo Del Cielo), and included the terrestrial analogs Dense Flood Basalt and Fused Silica. All samples were exposed for only a few seconds in the plasma stream. Significant melt flow and vaporization was observed for both the stony and iron meteorites during exposure. Mass loss from spallation of fragments was also observed. Vapor emitted atomic lines from alkali metals and iron, but did not emit the expected MgO molecular band emissions. The meteoritic melts flowed more rapidly, indicating lower viscosity, than those of Fused Silica. The surface recession was mapped. The effective heat of ablation derived from this showed that ablation under these conditions occurred in the melt-dominated regime. Ablation parameters have an effect on ground damage estimates. A bias in ablation parameters towards the melt-dominated regime would imply that impacting asteroids survive to lower altitude, and therefore could possibly have airbursts with a larger ground damage footprint.

Asteroid↗

Arcjet Ablation of Stony and Iron Meteorites

A test campaign was conducted placing meteorites in the 60 MW plasma Arcjet Interaction Heating Facility at NASA Ames Research Center, with the aim to achieve flight-relevant conditions for asteroid impacts in Earth's atmosphere and to provide insight into how meteoritic materials respond to extreme entry heating environments. The test conditions at heat flux of 4000 W/m2 and 140 kPa stagnation pressure are comparable to those experienced by a 30-meter diameter asteroid moving at 20 km/s velocity at 65 km altitude in the Earth's atmosphere. Test objects were a stony type H5 ordinary chondrite (Tamdakht) and an iron type IAB-MG meteorite (Campo Del Cielo), and included the terrestrial analogs Dense Flood Basalt and Fused Silica. All samples were exposed for only a few seconds in the plasma stream. Significant melt flow and vaporization was observed for both the stony and iron meteorites during exposure. Mass loss from spallation of fragments was also observed. Vapor emitted atomic lines from alkali metals and iron, but did not emit the expected MgO molecular band emissions. The meteoritic melts flowed more rapidly, indicating lower viscosity, than those of Fused Silica. The surface recession was mapped. The effective heat of ablation derived from this showed that ablation under these conditions occurred in the melt-dominated regime. Ablation parameters have an effect on ground damage estimates. A bias in ablation parameters towards the melt-dominated regime would imply that impacting asteroids survive to lower altitude, and therefore could possibly have airbursts with a larger ground damage footprint.

Arcjet↗

Start-up and Emergency Shutdown Modeling for a Coal-fired 10MWe sCO₂ Power Plant

As part of a Phase II Front End Engineering Design (FEED) study for the DOE Fossil Fuel Large Scale Pilots program, investigations of novel start-up and emergency shutdown methods for a stoker-fed, coal-fired, 10MWe sCO₂ power plant proposal were performed. These investigations were performed using 1D transient system models of the plant created within the GT-SUITE system modeling platform. The system model components were created using vendor quotation data (heat exchangers), performance maps (turbomachines), or FMU models (fired heater). Previously, Echogen Power Systems (Echogen) has used a sCO₂ power cycle start-up method that fills the system with liquid CO₂ to facilitate easy use of an electrically-driven start pump to transition the system from initial CO₂ fill to turbo-compressor initialization. The novel start-up method presented attempts this transition with a minimal filling of the system with liquid CO₂, to reduce the total CO₂ inventory required. This method leaves the start pump vulnerable to a two phase inlet condition as system pressure is below the CO₂ saturation pressure for the condenser cooling water temperature (Tcw). System model cases at Tcw of 18°C, 26°C, and 32°C, corresponding to cold, design, and hot ambient days, were analyzed to determine if the SP inlet condition could be kept as a subcooled liquid and estimate the CO₂ inventory reduction amount./p> Stoker-fed, coal-fired heaters continue to emit heat for some time even after emergency shutdown from events such as a power failure. This heat emission would lead to a failure of the fired heater, as the metal overheats, if the CO₂ flow is shut off. The emergency shutdown method presented utilizes CO₂ vented by a controllable vent valve (CRV) to provide CO₂ cooling flow to the fired heater. To determine the effectiveness of this method at keeping the fired heater peak tubing metal temperature below the ASME material temperature limit, for pressures below 5 MPa, of 816 °C, system model cases with CRV diameters ranging from 4” to 10”, and an alternative CO₂ vent routing with CRV size of 6”, were investigated./p>

01 COAL, LIGNITE, AND PEAT↗

Cyclic Combustion Variations in Dual Fuel Partially Premixed Pilot-Ignited Natural Gas Engines

Dual fuel pilot ignited natural gas engines are identified as an efficient and viable alternative to conventional diesel engines. This paper examines cyclic combustion fluctuations in conventional dual fuel and in dual fuel partially premixed low temperature combustion (LTC). Conventional dual fueling with 95% (energy basis) natural gas (NG) substitution reduces NOx emissions by almost 90%t relative to straight diesel operation; however, this is accompanied by 98% increase in HC emissions, 10 percentage points reduction in fuel conversion efficiency (FCE) and 12 percentage points increase in COVimep. Dual fuel LTC is achieved by injection of a small amount of diesel fuel (2-3 percent on an energy basis) to ignite a premixed natural gas₋air mixture to attain very low NOx emissions (less than 0.2 g/kWh). Cyclic variations in both combustion modes were analyzed by observing the cyclic fluctuations in start of combustion (SOC), peak cylinder pressures (Pmax), combustion phasing (Ca50), and the separation between the diesel injection event and Ca50 (termed "relative combustion phasing" ). For conventional dual fueling, as % NG increases, Pmax decreases, SOC and Ca50 are delayed, and cyclic variations increase. For dual fuel LTC, as diesel injection timing is advanced from 20° to 60° BTDC, the relative combustion phasing is identified as an important combustion parameter along with SoC, Pmax, and CaPmax. For both combustion modes, cyclic variations were characterized by alternating slow and fast burn cycles, especially at high %NG and advanced injection timings. Finally, heat release return maps were analyzed to demonstrate thermal management strategies as an effective tool to mitigate cyclic combustion variations, especially in dual fuel LTC.

Srinivasan, K. K.↗

Electrification Options for Multi-Family Water Heating in Cold Climates - Final Report

In multi-family buildings, large water storage tanks in centralized domestic hot water (DHW) systems can serve as thermal energy storage (TES) batteries to mitigate grid impact. These systems offer demand shift and efficiency benefits, significantly reducing peak power consumption, particularly in cold climates. This study evaluates the load-shifting benefits of a centralized heat pump water heater (HPWH) system equipped with a CO2 heat pump in multi-family buildings through simulation. The heat pump system and water storage tank are sized using design-day sizing. A finite-element-based stratified tank model and CO2 heat pump performance map from a commercial DHW product are used. Annual simulations are conducted to assess the benefits of the centralized DHW system for energy efficiency improvements, load shifting, and emission reductions. These simulations incorporate utility tariffs and marginal grid emission data from Los Angeles and Chicago. In Los Angeles, using a water tank as a thermal battery achieves 7.4% utility cost savings and 10.2% emission reduction. In Chicago, compared to HPWH conventional operation without preheating, TES-enabled central HPWH provides 15% utility cost savings and 13% emission reduction. The case study demonstrates that the demand reduction potential of central CO2 HPWHs is significant in cold climate regions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

MULTI-TECHNIQUE CHARACTERIZATION OF SUPERCONDUCTING MATERIALS FOR PARTICLE ACCELERATOR APPLICATIONS

We investigated the performance limitations of superconducting radio-frequency (SRF) cavities and materials using multiple experimental techniques. In particular, this study focuses on understanding the surface properties of nitrogen-doped Nb cavities and super?conducting thin films with higher Tc such as Nb3Sn. The main goal of this work is to use different techniques to better understand each aspect of the complex loss mechanism in superconductors to further improve the already highly efficient SRF cavities. Nitrogen doping applied to a Nb SRF cavity significantly improves the quality factor Q0 compared to a conventional Nb cavity, at an expense of reduced maximum accelerating gradient. The early quench mechanism was analyzed by using temperature maps before and during the quenching. The temperature maps revealed insignificant heating before the quench, and we concluded that nitrogen doping reduces critical magnetic fields in local regions, leading to premature quenching. To understand the origin of the increasing Q0 with the rf field, the density of states (DOS) of cold spots from nitrogen-doped and standard cavities were measured and analyzed using scanning tunneling microscopy. The results suggested that nitrogen doping reduces the spatial inhomogeneity of superconducting properties and shrinks the metallic suboxide layers, which tunes the DOS in such a way as to produce the field-induced reduction in the surface resistance. To characterize SRF thin films, an experimental setup for measuring a coplanar waveguide (CPW) resonator was developed and tested. A surface impedance measurement of the Nb film showed good agreement with the BCS calculation. The preliminary results from measurements of Nb3Sn and NbTiN films are also presented here. The nonlinear Meissner effect was investigated in Nb3Sn film CPW resonators by mea?suring the resonant frequency as a function of a parallel magnetic field. Contrary to a conventional quadratic dependence of the penetration depth ?(B) on the applied magnetic field B, as expected in s-wave superconductors, nearly a linear increase of ?(B) with B was observed. It was concluded that this behavior of ?(B) is due to weakly linked grain bound?aries on the polycrystalline Nb3Sn films, which can mimic the NLME expected in a clean d-wave superconductor.

Makita, Junki↗

Dynamics of heat-pipe reactors

A split-core heat pipe reactor, fueled with either U(233)C or U(235)C in a tungsten cermet and cooled by 7-Li-W heat pipes, was examined for the effects of the heat pipes on reactor while trying to safely absorb large reactivity inputs through inherent shutdown mechanisms. Limits on ramp reactivity inputs due to fuel melting temperature and heat pipe wall heat flux were mapped for the reactor in both startup and at-power operating modes.

Niederauer, G. F.↗

Dynamics of heat-pipe reactors.

A split-core heat-pipe reactor fueled with either 233-UC or 235-UC in a tungsten cermet and cooled by 7-Li-W heat pipes is examined for the effects of the heat pipes on this reactor in trying to safely absorb large reactivity inputs through inherent shutdown mechanisms. Limits on ramp reactivity inputs due to fuel-melting temperature and heat-pipe wall heat flux are mapped for the reactor in both startup and at-power operating modes.

Niederauer, G. F.↗

Shock wave/turbulent boundary-layer interactions with and without surface cooling

An experimental investigation was conducted to delineate the structure of the flowfield and temperature distributions in a shock wave/turbulent boundary-layer interaction with and without surface cooling. The Mach number upstream was about 3.5, and the wave angle was 23 deg. The wall to stagnation temperature ratio was 0.44 with cooling and 1.1 with heating. A detailed map of the interaction flowfields deduced from numerous boundary-layer traversing stations revealed the influence of wall cooling on the flowfield, wave structure, and size of the flow separation region. With surface cooling, the size of the separation region was much smaller, and the separation and reflected shock waves merged together near the edge of the velocity boundary layer, extending into the freestream as one wave.

Back, L. H.↗

Thermal vacuum testing of flexible radiator systems

Flexible fin radiators are being developed to meet spacecraft requirements of light weight, compact launch volume, modular growth, reusability, and the capability of an on-orbit deployment and retraction. Two prototype versions of deployable/retractable, flexible finspace radiators (soft and hard tube) were tested simultaneously under thermal vacuum conditions. A map of the heat rejection performance of each radiator panel under various environmental conditions is given. The soft tube radiator deployment system demonstrated minimal gas pressure and was capable of maintaining partial deployment; temperature control was achieved by varying the deployment length. The radiator could be recovered after an inadvertant freezing of the coolant in the Teflon tube. The hard tube radiator deployment mechanism performed adequately throughout the testing, but did exhibit some undesirable performance characteristics. The hard tube radiator pressure drop was higher than expected, but was not affected by the length of deployment. The radiator operated at less than full deployment, and the manifolds were found to have a significant effect on heat rejection. At low-load conditions, the hard tube radiator appeared to bypass its deployed area.

Rankin, G.↗

Mapping surface energy balance components by combining Landsat Thematic Mapper and ground-based meteorological data

Surface energy balance components were evaluated by combining satellite-based spectral data with on-site measurements of solar irradiance, air temperature, wind speed, and vapor pressure. Maps of latent heat flux density and net radiant flux density were produced using Landsat TM data for three dates. The TM-based estimates differed from Bowen-ratio and aircraft-based estimates by less than 12 percent over mature fields of cotton, wheat, and alfalfa.

Moran, M. Susan↗

Development of the GPM Observatory Thermal Vacuum Test Model

A software-based thermal modeling process was documented for generating the thermal panel settings necessary to simulate worst-case on-orbit flight environments in an observatory-level thermal vacuum test setup. The method for creating such a thermal model involved four major steps: (1) determining the major thermal zones for test as indicated by the major dissipating components on the spacecraft, then mapping the major heat flows between these components; (2) finding the flight equivalent sink temperatures for these test thermal zones; (3) determining the thermal test ground support equipment (GSE) design and initial thermal panel settings based on the equivalent sink temperatures; and (4) adjusting the panel settings in the test model to match heat flows and temperatures with the flight model. The observatory test thermal model developed from this process allows quick predictions of the performance of the thermal vacuum test design. In this work, the method described above was applied to the Global Precipitation Measurement (GPM) core observatory spacecraft, a joint project between NASA and the Japanese Aerospace Exploration Agency (JAXA) which is currently being integrated at NASA Goddard Space Flight Center for launch in Early 2014. From preliminary results, the thermal test model generated from this process shows that the heat flows and temperatures match fairly well with the flight thermal model, indicating that the test model can simulate fairly accurately the conditions on-orbit. However, further analysis is needed to determine the best test configuration possible to validate the GPM thermal design before the start of environmental testing later this year. Also, while this analysis method has been applied solely to GPM, it should be emphasized that the same process can be applied to any mission to develop an effective test setup and panel settings which accurately simulate on-orbit thermal environments.

Yang, Kan↗