Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “heat flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Machine learning based prediction of airflow maldistribution in air-to-refrigerant heat exchangers

Flow maldistribution is a common challenge in heat exchanger (HX) design and particularly important for air-to-refrigerant geometries where capacity losses can approach 65%. This has a major impact on central air conditioning systems, as compact duct design motivates the use of A-type HXs which are known to be affected by airflow maldistribution. Because velocity profiles are difficult to predict, components are often oversized leading to increased material cost, system footprint, and refrigerant charge. Several studies detail airflow maldistribution for individual HXs and packages, but findings cannot always be extrapolated to new designs. In this work, a machine learning (ML) based flow profile prediction framework is developed and applied to two common package configurations: (i) A-type and (ii) U-type HXs, across a broad range of HX geometries and flow rates. Porous media CFD simulations are validated against independent data for both package types as well as comprehensive in house measurements for a finless geometry with shape optimized non-round tubes, which validates the framework for new heat transfer surfaces. The ML models are trained on the porous media CFD simulations, predicting volumetric flow rate (VFR) within 1.1% and 1.9% with maximum relative L 2 norm errors of 0.48 and 0.65, respectively, while also delivering 10 5 speed up factor compared to full porous media CFD. HX level simulations show an up to 9% reduction in heat transfer from flow maldistribution, with greater losses occurring at smaller half apex angles. This framework enables rapid and highly accurate prediction of airflow maldistribution induced capacity degradation.

42 ENGINEERING↗

Flow boiling transient critical heat flux tests with stainless steel and FeCrAl: Transient correlation implementation, model calibration, and sensitivity analysis

In this study, steady-state and transient internal-flow critical heat flux (CHF) experiments were carried out under two flow conditions, at atmospheric pressure, on 316 stainless steel (316-SS) and iron-chromium-aluminum (FeCrAl) tubes. Slow power transients at a low mass flow (300 kg/m 2 - s) with very low subcooling (X e =-0.0054) generated premature CHFs, which were prevented by faster power transients and high mass flow (1000 kg/m 2 - s). The measured transient CHFs increased linearly with increasing power transients, compared with the steady-state CHF. Yet, the wall superheat at the CHFs decreased with faster power transients. Transient CHF correlations highlighting heterogeneous spontaneous nucleation were calibrated to the measured CHFs and compared with other existing correlations. Transient CHF multipliers were acquired from pool and flow boiling empirical CHF correlations that were generated. The multipliers were applied to the RELAP5-3D nuclear system code to analyze the discrepancies between the measured data and the predicted CHF and post-CHF behavior, which improved peak cladding temperature predictions by 24.6%. A variance-based global sensitivity study perturbing the experimental uncertainties and cladding material thermal properties showed the diminishing influence of flow boiling heat transfer with increasing power transients, highlighting the significance of the volumetric heat capacity for the cladding integrity during transients. Transient CHF correlations were applied to the most limiting design basis accident: a hot-zero-power reactivity-initiated accident on a generic pressurized water reactor RELAP5-3D model.

36 MATERIALS SCIENCE↗

Design, Flow Field, and Heat Transfer Characterization of the Conjugate Aero-Thermal Test Facility at NETL

A new aerothermal test facility was constructed for the purpose of studying film cooling performance in an environment that accurately simulates conjugate heat transfer characteristics that exist in engine operation. Here, this paper details the design of the facility and the plan for conducting steady state film cooling experiments to improve the understanding of conjugate heat transfer scaling from laboratory to engine conditions. The test facility consists of two separate low channels (hot gas/coolant) and each gas path has a flow conditioning section, a convergent nozzle and a test section/channel with viewports. Numerical simulations were conducted to predict flow field characteristics supporting the design of the flow loop facility. Preliminary experiments were conducted to characterize the flow field using velocity and temperature profile measurements. In addition, infrared (IR) thermography methods were developed to measure surface temperatures on the hot side of the test plate. The IR measurement methods including calibration of the IR camera is explained in detail. It was concluded that appropriate hot gas path flow conditioning could be achieved using a strainer-like tube, a perforated plate, and a honeycomb-mesh screen system upstream of the test section. Flow field measurements from preliminary experiments showed that the boundary layer profile follows the law of the wall.

47 OTHER INSTRUMENTATION↗

Modeling and Experimental Validation of a Direct-Contact Counter-Flow Fluidized Bed Heat Exchanger for Thermal Energy Storage (TES) Applications

Particle-based thermal energy storage (TES) systems are an emerging energy storage technology. The technological advances have reduced costs, making TES more competitive and reliable in the marketplace but an efficient and reliable operation is heavily dependent on coherent heat transfer between air to particles or vice versa. The particle-based TES technologies provide an intermediate system that can store energy for short (0-10 h), long (10-200 h) and seasonal (> 200 h) timescales. The TES systems store energy by converting electricity to thermal energy; electricity can be directly sourced intermittent generation technologies and/or the grid, helping manage peak loads and other mismatches in supply and demand. The overall efficiency of the TES system depends on the performance of system components (particle storage silos and particle transfer mechanism etc.). The particle heat exchanger is one of the key system components that affects the system efficiency. The pressurized fluidized bed heat exchanger (PFB HX) performance is challenging to predict due to the chaotic behavior of particle and fluid interaction. This research presents a computational study of a novel direct-contact, counter-flow and air-to-particles PFB HX, that contributes in advancing the particle-based long-duration TES technologies. For the current analysis an unsteady Eulerian-Eulerian CFD model was developed and validated against experiments performed at the National Laboratory of the Rockies for two particle sizes (600 ..mu..m and 825 ..mu..m ). Following validation, parametric simulations were conducted to evaluate the effects of interphase drag models (Syamlal-O'Brien and Gidaspow), particle size, bed height and the influence of a frictional-viscosity term on hydrodynamics and heat transfer between the air & particles. The key findings from the analysis are: (1) for the studied operating window Syamlal-O'Brien provides superior agreement with measured gas temperatures (errors generally < 10%) while Gidaspow shows large deviations for the coarse particle case; (2) model predictions are most sensitive in the lower 0.2 m above the air distributor where bubble initiation and local mixing dominate interphase heat transfer; (3) representation of the distributor (number of inlet ports) materially affects predicted local mixing and temperature stratification; and (4) the Eulerian-Eulerian framework reproduces bulk thermal trends but shows regime dependent limitations for coarse particles, motivating mesoscale informed closures for scale-up analysis for future studies. These results provide validated guidance for drag selection and distributor design in particle-based thermal energy storage applications. Collectively, the validated model and parametric results quantify key drivers of PHB-HX performance and provide practical guidance for design and optimization. The results provide confidence in the model predictability and provide a step forward to improve on heat exchange performance. The demonstrated performance and modeling approach support the deployment and further development of this novel PHB-HX concept for robust, particle-based long-duration thermal energy storage systems.

25 ENERGY STORAGE↗

Particle transport-driven flow dynamics and heat transfer modulation in solar photovoltaic modules: Implications on soiling

Wind-swept debris and excessive heating reduce solar photovoltaic efficiency and accelerate panel degradation. For many solar plants in open environments, particle deposition is well-understood to exacerbate efficiency losses by blocking useable light and insulating panel surfaces. However, little is known about particle behavior in multi-panel systems, where complex wakes dominate and alter trajectories. This study examines debris-laden flow within a scaled array of two model solar panels, observing convective cooling and focusing on turbulent inter-panel flow dynamics. Convection is compared between the first and second panels (P 1 and P 2 ) and for a single inflow velocity at four particle concentrations (Φ v ), including a neutrally buoyant particle (i.e. tracer) case and three water droplet cases. Tracers and Φ v > 0 concentrations show increased convective heat transfer for P 2 compared to P 1 , while inertial particle presence and increased concentration reduces this improvement from +170% to +90%. Particle image velocimetry surrounding P 2 reveals dampened inter-panel wake features for particle-laden flow compared to the tracer case, where diminished mean flow and mean kinetic energy breakdown are observed for the particles due to their inertia. Together, the reduction in comparative convection and dampened wake effects accompanying inertial particle concentration motivates further studies on coupled array physics in debris-filled flow.

14 SOLAR ENERGY↗

Operation and Optimization of Microwave-Heated Continuous-Flow Microfluidics

Microwave (MW) technology can be powerful for electrification and process intensification but limited fundamental understanding of scalability and design principles hinders its effective use. In this work, we build a continuous-flow microreactor inside a commercial single-mode MW applicator and the corresponding computational fluid dynamics model to simulate the temperature profile. The model is in good agreement with experiments for various microreactor dimensions and operating conditions. The model indicates that MW heating is greatly influenced by reactor geometry as well as the operating parameters. We observe a strong correlation between parameters and develop a gradient boost regression tree model to predict the outlet temperature accurately. This model is then applied to optimize the dimensions and operating conditions to maximize the outlet temperature and energy efficiency, resulting in a Pareto optimal. We demonstrate computationally and experimentally that it is possible to surpass the Pareto optimal and achieve an energy efficiency of ~90% or greater at temperatures relevant for liquid-phase chemistry via salting of the solvent. The present methodology can be applied to other complex MW reactors. Lastly, the combined numerical and experimental approach provides insights into and a framework for scale-up and optimization.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Flow maldistribution in plate heat exchangers – Impact, analysis, and solutions

Plate heat exchangers are commonly used in various industrial applications, such as refrigeration, air conditioning, heat pumps, powerplants, and chemical industries. Plate heat exchangers are well known for their superior heat transfer performance, compactness, and low refrigerant charge. Despite offering several advantages, they suffer from flow maldistribution issues. The flow maldistribution can deteriorate both the heat transfer and pressure drop performance, ultimately resulting in a lower system efficiency where plate heat exchangers are deployed. The flow maldistribution issues become more pronounced when the heat exchanger size is relatively large and the number of plates is higher, limiting the deployment of plate heat exchangers in larger industrial systems. Consequently, analyzing and understanding the flow maldistribution behavior in plate heat exchangers and finding ways to mitigate flow maldistribution related issues become essential topics of interest. Further, this review aims to address the effect of flow maldistribution on plate heat exchanger characteristics. First, the experimental and numerical works on flow maldistribution under single-phase and two-phase conditions are detailed. Subsequently, the end-channel and end-plate effects are discussed. Then, the methods to mitigate flow maldistribution in plate heat exchangers are outlined. Finally, based on a thorough literature survey and industrial requirements, future research directions are recommended.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High-temperature NMR MAS probe with optimized temperature gradient across sample rotor

A rotor housing assembly for NMR spectroscopy. An elongate rotor has a distal drive end, a proximal end and an internal sample space positioned along its length between the drive and proximal ends. The rotor is driveable about a rotation axis by a drive gas flow. A rotor housing has an interior space in which the rotor is at least partially received. At least one first heated gas flow inlet is positioned opposite the internal sample space, through which a first heated gas flow is controllably flowable into the interior space to heat it and the rotor. At least a pair of spaced apart second heated gas flow outlets are axially spaced from the first heated gas flow inlet to controllably convey a second heated gas flow to heat distal and proximal areas of the sample space to minimize a temperature gradient extending axially within the sample space.

Mehta, Hardeep S.↗

Experimental Study on Flow Behavior and Heat Transfer Enhancement With Distinct Dimpled Gas Turbine Blade Internal Cooling Channel

Abstract The study presents the investigation on heat transfer distribution along a gas turbine blade internal cooling channel. Six different cases were considered in this study, using the smooth surface channel as a baseline. Three different dimples depth-to-diameter ratios with 0.1, 0.25, and 0.50 were considered. Different combinations of partial spherical and leaf dimples were also studied with the Reynolds numbers of 6,000, 20,000, 30,000, 40,000, and 50,000. In addition to the experimental investigation, the numerical study was conducted using a large eddy simulation (LES) to validate the data. It was found that the highest depth-to-diameter ratio showed the highest heat transfer rate. However, the deepest dimpled channel shows the highest pressure drop, which affects the overall thermal performance of the cooling channel. The results showed that the leaf dimpled surface is the best cooling channel based on the highest Reynolds number's heat transfer enhancement and friction factor. However, at the lowest Reynolds number, partial spherical dimples with a 0.25 depth-to-diameter ratio showed the highest thermal performance.

Energy & Fuels↗

Air-to-Liquid Heat Exchanger Fabricated Using Deposition-Based Additive Manufacturing Processes

Abstract This work describes the use of deposition-based additive manufacturing (AM) techniques to fabricate air-cooled, two-fluid heat exchangers. The project focused on a Heating, Ventilation and Air Conditioning application and used an industry-standard copper/aluminum heat exchanger manufactured with conventional technology as the basis for assessing performance. The manufacturing constraints associated with using deposition-based AM technology for this application include the need for a continuous tool path within each build layer that allows uninterrupted extrusion and therefore defect-free water channel walls that correspond to a reliably leak-tight heat exchanger. A geometry that respects these constraints was developed, simulated, optimized and finally manufactured and tested. The material used was a composite of polymer filled with conductive flakes in order to provide high conductivity in the direction that heat must flow in this heat exchanger, across the wall separating the fluids. The measured performance for several test coupons matched the predicted performance and the test coupons exhibited performance that approach and in some cases exceeds conventional technology

Engineering↗

Complementary Study of Radiative Heat Transfer and Flow Physics from Moderate-scale Hydrocarbon Pool Fire Simulations

As part of the Advanced Simulation and Computing Verification and Validation (ASCVV) program, a 0.3-m diameter hydrocarbon pool fire with multiple fuels was modeled and simulated. In the study described in this report, systematic examination was performed on the radiation model used in a series of coupled Fuego/Nalu simulations. A calibration study was done with a medium-scale methanol pool fire and the effect of calibration traced throughout the radiation model. This analysis provided a more detailed understanding of the effect of radiation model parameters on each other and on other quantities in the simulations. Heptane simulation results were also examined using this approach and possible areas for further improvement of the models were identified. The effect of soot on radiative losses was examined by comparing heptane and methanol results.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Study of Radiative Heat Transfer and Flow Physics from Medium-scale Methanol Pool Fire Simulations [Slides]

Analysis of methanol pool fire conducted as part of validation study for SIERRA/Fuego. Radiation model was effectively calibrated by modifying radiation model parameters for methanol. Computing integrated buoyancy flux, entrainment rate, and turbulent kinetic energy allowed for evaluation of less typical quantities in this validation study. Quantities were compared with experimental data or correlations and generally showed agreement. TKE needed fine mesh to be computed accurately. Predicted flame height less sensitive to variations in mixture fraction than temperature. Mixture fraction is a preferable threshold variable for this application.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗