Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “grid storage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Self-Driving Microscopy for AI/ML-Enabled Physics Discovery and Materials Optimization

Materials are the bedrock of economy and foundation for all real-world technologies. The viability of space travel, grid energy storage, solar to fuels conversion, methane removal, and photovoltaic energy solutions hinge on the discovery and optimization of novel materials and rapid scaling toward manufacturing. The last 20 years have seen an exponential growth in the theoretical predictive capability for crystalline materials and small molecules. However, it is only in the last five years that we have seen the rapid expansion of high-throughput synthesis enabled by laboratory robotics and microfluidics, as well as a resurgence of combinatorial synthesis (Abolhasani and Kumacheva 2023; Epps and Abolhasani 2021; Jiang et al. 2022; Rajan 2008; Soldatov et al. 2021; Szymanski et al. 2023). Combinatorial synthesis, microfluidics, and ultimately dip-pen megalibraries have demonstrated the ability to “write” multicomponent nanomaterials at high throughput scale, generating millions of material examples in the 3D, 4D, and 5D composition spaces (Chen et al. 2016, 2019; Jibril et al. 2022).

36 MATERIALS SCIENCE↗

Valve Regulated Lead Acid Battery Evaluation under Peak Shaving and Frequency Regulation Duty Cycles

This work highlights the performance metrics and the fundamental degradation mechanisms of lead-acid battery technology and maps these mechanisms to generic duty cycles for peak shaving and frequency regulation grid services. Four valve regulated lead acid batteries have been tested for two peak shaving cycles at different discharge rates and two frequency regulation duty cycles at different SOC ranges. Reference performance and pulse resistance tests are done periodically to evaluate battery degradation over the time. The results of the studies are expected to provide a valuable understanding of lead acid battery technology suitability for grid energy-storage applications.

25 ENERGY STORAGE↗

Molten sodium batteries: advances in chemistries, electrolytes, and interfaces

The need for clean, renewable energy has driven the expansion of renewable energy generators, such as wind and solar. However, to achieve a robust and responsive electrical grid based on such inherently intermittent renewable energy sources, grid-scale energy storage is essential. The unmet need for this critical component has motivated extensive grid-scale battery research, especially exploring chemistries “beyond Li-ion”. Among others, molten sodium (Na) batteries, which date back to the 1960s with Na-S, have seen a strong revival, owing mostly to raw material abundance and the excellent electrochemical properties of Na metal. Recently, many groups have demonstrated important advances in battery chemistries, electrolytes, and interfaces to lower material and operating costs, enhance cyclability, and understand key mechanisms that drive failure in molten Na batteries. For widespread implementation of molten Na batteries, though, further optimization, cost reduction, and mechanistic insight is necessary. In this light, this work provides a brief history of mature molten Na technologies, a comprehensive review of recent progress, and explores possibilities for future advancements.

25 ENERGY STORAGE↗

Challenges and Prospects of Sodium‐Ion and Potassium‐Ion Batteries for Mass Production

The exponential growth of the lithium‐ion (LIB) market is causing a significant disparity between the supply chain and demand for its resources. In this regard, sodium‐ion and potassium‐ion batteries are promising alternatives to LIBs due to their low cost. However, the larger sizes of Na + and K + ions create challenges that prevent them from achieving energy densities comparable to LIBs while maintaining an acceptable cycle life. Here, in this perspective, the aim is to evaluate the status of Na‐ion and K‐ion batteries and the challenges associated with them on both fundamental and commercial levels. The focus is on the structural instability arising from phase transitions during cycling, intricate chemical degradation processes, and potential avenues for enhancing their performance with a specific goal of improving their viability for grid‐scale energy storage. Materials production and abundance limitations for the chemistries of the state‐of‐the‐art materials and account for critical parameters from both the perspective of researchers and investors are analyzed. This analysis aims to provide insights into the strategic trade‐offs required to effectively implement the technology in real‐world applications, such as grid‐scale storage and other areas. Furthermore, the utilization of metals with low or no supply‐chain problems as an important aspect of these trade‐offs is considered.

25 ENERGY STORAGE↗

ARIES/Flatirons Facility - Hydrogen System Capability Buildout

Under the "Advanced Research on Integrated Energy Systems" (ARIES) initiative, hydrogen system capabilities including a MW-scale electrolyzer, storage system, and MW-scale fuel cell generator will be designed and commissioned at NREL's Flatirons Campus. This hydrogen infrastructure will support H2@Scale goals by enabling integrated systems R&D to study the science of scaling for hydrogen energy systems.The system is designed with flexibility to provide a testbed to demonstrate systems integration, grid services, energy storage, direct renewable hydrogen production, and innovative end use applications (e.g. HD transportation, natural gas blending, etc.).

Advanced Research on Integrated Energy Systems↗

Grid-Scale Ternary-Pumped Thermal Electricity Storage for Flexible Operation of Nuclear Power Generation under High Penetration of Renewable Energy Sources

In this work, the integration of a grid-scale ternary-Pumped Thermal Electricity Storage (t-PTES) with a nuclear power generation to enhance operation flexibility is assessed using physics-based models and digital real time simulation. A part of the electricity from the nuclear power generation is delivered to the grid, and the balance is used to power a heat pump that can be augmented by an auxiliary resistive load element to increase the charging rate of the thermal storage. This increases the thermal potential between hot and cold thermal stores (usually solid materials or molten salts inside large storage tanks). The thermal energy is transformed back into electricity by reversing the heat pump cycle. Different transient scenarios including startup, shutdown, and power change for grid-connected operation are simulated to determine the behavior of the hybrid nuclear-t-PTES system operating under variable loads that constitute a departure from conventional, baseload nuclear plant operation schemes. Ternary refers to the three modes operation: (i) heat pump (including heating coil), (ii) heat engine, and (iii) simultaneous operation of heat pump (including heating coil) and heat engine during changeover from pumping to generation or vice-versa. The controllability of t-PTES in the short timescales as a dynamic load is used to demonstrate operational flexibility of hybrid nuclear plants for flexible operation through advanced load management. The integration of t-PTES into nuclear power systems enhances the system flexibility and is an enabler for high penetration of renewable energy resources.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimal design and integration of decentralized electrochemical energy storage with renewables and fossil plants

Increasing renewable energy requires improving the electricity grid flexibility. Existing measures include power plant cycling and grid-level energy storage, but they incur high operational and investment costs. Using a systems modeling and optimization framework, we study the integration of electrochemical energy storage with individual power plants at various renewable penetration levels. Furthermore, our techno-economic analysis includes both Li-ion and NaS batteries to encompass different technology maturity levels. A California case-study indicates localized integration to be cost-effective for greater grid flexibility. Li-ion batteries can mitigate the residual demand fluctuations of small to medium-sized plants, while NaS batteries would be best-suited for larger storage with higher renewable penetration. Overall, the battery-enabled renewable integration could reduce the unmet grid demand by 75%, the renewable curtailment by 58%, and the CO 2 emission intensity by 16% while including the life cycle emissions of the battery and the renewable farm. Our scenario-based analysis also indicates that rather than replacing all fossil power plants, it is more economical to combine batteries and renewables with individual fossil plants to achieve a clean energy grid.

25 ENERGY STORAGE↗

Microstructure‐Dependent Sodium Storage Mechanisms in Hard Carbon Anodes

Sustainable energy storage is essential to support the transition to renewables and meet the increasing demand for energy. Sodium‐ion batteries (NIBs) are attractive for grid‐scale energy storage due to the abundance and low cost of sodium, sustainability of other battery components, and electrochemical performance. Hard carbon (HC) is a leading anode material for NIBs, but its complex microstructure complicates the understanding of sodium storage mechanisms. Using X‐ray total scattering and density functional theory calculations, this study clarifies how HC's microstructural variations influence sodium storage across the slope (high potential) and plateau (low potential) regions of the potential capacity curve. In the slope region, sodium initially adsorbs at high‐binding energy defect sites and subsequently intercalates between graphene layers, adsorbing at low‐binding energy defect sites, correlating with different slopes observed during initial sodiation. Initial irreversibility arises from sodium trapping at surface defects and solid electrolyte interface formation. In the plateau region, sodium simultaneously intercalates and fills pores, influenced by pore size, interlayer spacing, and defect concentration. HCs with larger pore sizes form larger sodium clusters. In conclusion, the proposed mechanism underscores the role of microstructure engineering in enhancing HC performance and advancing NIBs for grid‐scale energy storage.

36 MATERIALS SCIENCE↗

Cost targets to achieve commercially viable thermal storage in buildings

To mitigate the variation in demand on the electric grid, thermal energy storage (TES) is an alternative to electric batteries or installing new peaking power plants. Stakeholders and policy makers across the United States have expressed interests in promoting TES, as demonstrated by the US Department of Energy’s Grid-Interactive Efficient Buildings program and the efforts of various state legislatures. However, the cost value provided by TES are unclear. If reliable cost benefits were determined, stakeholders would have a clearer picture of the financial returns that can be gained from their investment in TES. In this report, EnergyPlus was used to perform whole-building simulations for two residential buildings in Indianapolis and Atlanta. The HVAC system in both buildings were equipped with phase change material TES. The TES tank was charged in off-peak hours and discharged in peak hours to perform load shifting. First, the economic value implied by existing time-of-use (TOU) rates offered by utility companies was analyzed via whole-building simulation. Second, existing demand reduction (DR) incentives sourced from 3 different electrical grid administrators (i.e., California, Texas, and New England region) were surveyed to determine their implied value. Lastly, the economic value implied by different types of deferred peak power plants were reviewed. The full value of TES to the entire society consists of value to the utility, OEMs, facility installers, and other stakeholders. This report focuses on the value to the utility with emphasis on the deferred capital of peak power plant. The value from the deferred capital of peak power plant is manifested to the customer in the form of demand reduction program and Time-of-Use utility rate program. In this report, an initial proxy of the value of TES is made by assuming the deferred capital cost of power plant is the full value to reduce peak demand. Three levels of financial value of TES systems were assessed. Two are currently available to some residential customers: (1) the benefit from TOU pricing alone and (2) the benefit from TOU pricing in combination with DR incentive programs. The third level was computed as the full cost of deferred capital cost of peaking power plants. This represents the potential value that could be gained by the utilities or conceivably be offered to consumers.

25 ENERGY STORAGE↗

Quantification of Energy Savings and Demand Reduction for a Heat Pump Integrated with Thermal Energy Storage (Final Report)

To mitigate the variation in demand on the electric grid, thermal energy storage (TES) is an alternative to electric batteries or installing new peaking power plants. Stakeholders and policy makers across the United States have expressed interests in promoting TES, as demonstrated by the US Department of Energy’s Grid-Interactive Efficient Buildings program and the efforts of various state legislatures. However, the cost value provided by TES are unclear. If reliable cost benefits were determined, stakeholders would have a clearer picture of the financial returns that can be gained from their investment in TES. The study in this report is conducted by ORNL with collaboration with Emerson the Helix Innovation Center. In the first part of this report, EnergyPlus was used to perform whole-building simulations for two residential buildings in Indianapolis and Atlanta. The HVAC system in both buildings were equipped with phase change material TES. The TES tank was charged in off-peak hours and discharged in peak hours to perform load shifting. First, the economic value implied by existing time-of-use (TOU) rates offered by utility companies was analyzed via whole-building simulation. Second, existing demand reduction (DR) incentives sourced from 3 different electrical grid administrators (i.e., California, Texas, and New England region) were surveyed to determine their implied value. The study suggests that the traditional value analysis that focuses on ROI for the building owner significantly undervalues TES technology making economic viability difficult. A more comprehensive value analysis that includes peak demand management and deferred capital for peaking power plants shows that TES should be economically viable but here the value is greater for the utility and requires large market penetration and aggregation to fully realize the benefits. Therefore, to facilitate commercialization, new business models are needed that include a broader range of stakeholders and distribute the value of TES proportionally. In the 2 nd part of this project, the benefits of a novel phase change material (PCM) integrated heat pump configuration were evaluated via detailed component based simulation. A one-dimensional PCM heat exchanger model which discretizes the PCM tank and refrigerant tubes into small control volumes is developed. Each control volume can have different PCM temperatures, PCM properties, and heat transfer coefficients. The PCM tank is charged by a wrapped tank condenser and discharged by an internal refrigerant coil. The PCM heat exchanger model is integrated into DOE/ORNL Heat Pump Design Model for heat pump system simulation. To demonstrate the performance of the PCM integrated heat pump, a case study in Chicago was performed. A Time-of-Use utility structure-based control strategy is implemented to schedule the PCM tank charging and discharging mode switching. Compared with a conventional electric heat pump, the PCM integrated heat pump shows superior performance on load shifting and utility cost reduction. As a result, the proposed system demonstrates 24.6% utility saving for cooling application and 25.8% utility saving for heating application.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The value of in-reservoir energy storage for flexible dispatch of geothermal power

Geothermal systems making use of advanced drilling and well stimulation techniques have the potential to provide tens to hundreds of gigawatts of clean electricity generation in the United States by 2050. With near-zero variable costs, geothermal plants have traditionally been envisioned as providing “baseload” power, generating at their maximum rated output at all times. However, as variable renewable energy sources (VREs) see greater deployment in energy markets, baseload power is becoming increasingly less competitive relative to flexible, dispatchable generation and energy storage. Herein we conduct an analysis of the potential for future geothermal plants to provide both of these services, taking advantage of the natural properties of confined, engineered geothermal reservoirs to store energy in the form of accumulated, pressurized geofluid and provide flexible load-following generation. We develop a linear optimization model based on multi-physics reservoir simulations that captures the transient pressure and flow behaviors within a confined, engineered geothermal reservoir. We then optimize the investment decisions and hourly operations of a power plant exploiting such a reservoir against a set of historical and modeled future electricity price series. Further, we find that operational flexibility and in-reservoir energy storage can significantly enhance the value of geothermal plants in markets with high VRE penetration, with energy value improvements of up to 60% relative to conventional baseload plants operating under identical conditions. Across a range of realistic subsurface and operational conditions, our modeling demonstrates that confined, engineered geothermal reservoirs can provide large and effectively free energy storage capacity, with round-trip storage efficiencies comparable to those of leading grid-scale energy storage technologies. Optimized operational strategies indicate that flexible geothermal plants can provide both short- and long-duration energy storage, prioritizing output during periods of high electricity prices. Sensitivity analysis assesses the variation in outcomes across a range of subsurface conditions and cost scenarios.

15 GEOTHERMAL ENERGY↗

Globally Gridded Groundwater Extraction Volumes and Costs under Six Depletion and Ponded Depth Targets

This repository contains simulated outputs from superwell – a hydro-economic tool for long-term assessment of groundwater cost and supply – providing globally gridded groundwater extractable volumes and associated unit costs ($/km³) for accessible groundwater production, based on a variety of user-defined depletion and ponded depth scenarios. Key model documentation: Niazi, H., Ferencz, S. B., Graham, N. T., Yoon, J., Wild, T. B., Hejazi, M., Watson, D. J., & Vernon, C. R. (2025). Long-term hydro-economic analysis tool for evaluating global groundwater cost and supply: Superwell v1.1. Geoscientific Model Development, 18(5), 1737-1767. https://doi.org/10.5194/gmd-18-1737-2025 Find the source code of the superwell model on GitHub: https://github.com/JGCRI/superwell Repository Overview Main output: superwell_outputs.7z contains 6 files (4.5 GB) named as superwell_py_deep_all_0.*PD_0.*DL.csv. These files present superwell outputs of global groundwater extraction volumes and cost estimates on a 0.5° scale for six scenarios with different Ponded Depth (PD; 0.3 and 0.6 m) and Depletion Limit (DL; 5%, 25%, and 40% of available volume) targets over the entire pumping lifetime of a grid cell superwell_py_deep_all_0.3PD_0.25DL_sample_100.csv contains superwell outputs for 100 data points sampled to match the global inputs' distribution superwell_py_deep_all_0.3PD_0.25DL_Grid_72548.csv contains superwell output for a single grid cell concept_v5.png provides an overview of the superwell workflow Outputs Description year_number: year of pumping depletion_limit: set depletion limit (DL) as a volume fraction of total available groundwater Mappings: continent, country, gcam_basin_id, Basin_long_name, grid_id: geographic identifiers and basin information Inputs: grid_area (km²): area of the grid cell whyclass: hydrogeological classification of the aquifer permeability (m/day), porosity (%), total_thickness (m), depth_to_water (m): aquifer properties. The geo-processed input data has been published separately: https://doi.org/10.57931/2307831 Model outputs: orig_aqfr_sat_thickness (m), aqfr_sat_thickness (m): original and remaining/instantaneous saturated thickness of the aquifer hydraulic_conductivity (m/day), transmissivity (m²/day): hydraulic properties of the aquifer radius_of_influence (m), areal_extent (km²): well radius and area of influence from the center of the well number_of_wells (-): number of wells in a grid cell determined by a ratio of well area and grid area max_drawdown (m), drawdown (m), drawdown_interference (m): well and aquifer drawdown during extraction total_head (m): total lift for the groundwater (depth to water plus drawdown) total_well_length (m): total depth of wells drilled well_yield (m³/day): pumping rate or well yield power (kW), energy (kWh): power and energy required for pumping groundwater Volume Outputs: volume_produced_perwell (m³), cumulative_vol_produced_perwell (m³): production volume metrics per well volume_produced_allwells (m³), cumulative_vol_produced_allwells (m³): aggregate extraction volumes for all wells in a grid cell available_volume (m³): available groundwater in storage for the grid cell as determined by aquifer properties depleted_vol_fraction: fraction of total volume pumped over available volumes in a grid cell (same as depletion limit) Cost Outputs: well_installation_cost ($): well installation cost based on the hydrogeological complexity of the aquifer annual_capital_cost, maintenance_cost, nonenergy_cost ($): nonenergy costs energy_cost_rate ($/kWh): electricity rate energy_cost ($): energy cost of pumping groundwater total_cost_perwell ($), total_cost_allwells ($): total annual energy and non-energy cost for each and all wells in a grid cell a unit_cost ($/m³), unit_cost_per_km3 ($/km³), unit_cost_per_acreft ($/acre-ft): total cost of pumping a unit of groundwater, indicated for different spatial units Key Resources Model documentation: Niazi, H., Ferencz, S., Graham, N., Yoon, J., Wild, T., Hejazi, M., Watson, D., & Vernon, C. (2024; In-prep). Long-term Hydro-economic Assessment Tool for Evaluating Global Groundwater Cost and Supply: Superwell v1. Geoscientific Model Development. Input data: Niazi, H., Watson, D., Hejazi, M., Yonkofski, C., Ferencz, S., Vernon, C., Graham, N., Wild, T., & Yoon, J. (2024). Global Geo-processed Data of Aquifer Properties by 0.5° Grid, Country and Water Basins. MSD-LIVE Data repository. https://doi.org/10.57931/2307831 superwell source code: https://github.com/JGCRI/superwell Cite as Niazi, H., Ferencz, S., Yoon, J., Graham, N., Wild, T., Hejazi, M., Watson, D., & Vernon, C. (2024). Globally Gridded Groundwater Extraction Volumes and Costs under Six Depletion and Ponded Depth Targets. MSD-LIVE Data repository. https://doi.org/10.57931/2307832 Contact Reach out to Hassan Niazi or Stephen Ferencz or open an issue in the superwell repository for questions or suggestions.

Earth Systems↗

Hierarchical Control and Stability Analysis for a Nonisolated Grid-Tied DC Energy Router Integrating Energy Storage and Partial Distributed Generation

This article proposes a nonisolated dc converter-based energy router (dc-ER) and its operating strategy. Here, the intent is to integrate energy storage (ES), distributed generation (DG), local load, and dc power grid in an autonomous and more efficient way. The ES/DG power ports are coupled with each other in partial-type connections, which obtains higher voltage supply gain and direct input–output power transmission. High-voltage supply gain allows a wide solar power tracking range and the possibility of optimal battery charging/discharging. Direct input–output power transmission improves the energy conversion efficiency. In this article, the operating modes of dc-ER are first analyzed, followed by the optimal hardware design counting the DG current ripple minimization and the limitation caused by the power flow direction. Second, the mathematical model of dc-ER is deduced. The hierarchical control is then proposed to manage port energy in a flexible manner. The stability is analyzed by using impedance modeling. Finally, experimental and simulation results verify the superiorities of the proposed topology in terms of flexible operating mode transition and high-power conversion efficiency.

25 ENERGY STORAGE↗

Battery energy storage control systems and methods for a grid tie inverter coupled to a photovoltaic system

A distributed control system uses a central controller in Internet communication with a local controller to manage grid tie attachment with a battery to form an integrated battery energy storage system (BESS). The BESS is capable of charging or discharging the battery, as well as correcting grid phase with volt amp reactive (VAR) leading or lagging operation modes. Examples shown include simple BESS charging and discharging, BESS integrated with renewable energy sources (here photovoltaic), and direct current fast charge (DCFC) connections with an electric vehicle.

Gadh, Rajit↗

Modeling the Potential Impact of Storage on the US Power Sector in a Multisector Dynamic Context

The electric power sector is expected to grow in size, importance, and complexity around the world as economies expand and electric supply technologies and demand patterns evolve in significant ways. At the same time the electric power sector may see substantial increases in VRE generating technologies which can add variability and uncertainty to the diurnal and seasonal profile of electric supply. With these forces in play, the emergence of modular, flexible electricity storage technologies may have profound impacts on the operation of electric power systems. Here we reduce a storage modeling gap in MSD models by incorporating grid-based electricity storage into the electric sector dynamics of the Global Change Analysis Model-USA (GCAM-USA) with improved power sector representation. We find a potentially significant role for storage technologies in the future of the U.S. power system, with storage capacity ranging from 7.7 to 14.7 GW in 2050 and 13.9 to 31.6 GW in 2100 across several techno-economic scenarios. We also find that storage can help to smooth variability in residual load arising from evolving electricity demands and the introduction of high shares of VRE to the electric grid. This reduces reliance on high-cost peaking generators, improves system-wide capacity factors, and limits curtailment of VRE.

Patel, Pralit L.↗

Perspective—On the Need for Reliability and Safety Studies of Grid-Scale Aqueous Batteries

Li-ion batteries currently dominate electrochemical energy storage for grid-scale applications, but there are promising aqueous battery technologies on the path to commercial adoption. Though aqueous batteries are considered lower risk, they can still undergo problematic degradation processes. This perspective details the degradation that aqueous batteries can experience during normal and abusive operation, and how these processes can even lead to cascading failure. We outline methods for studying these phenomena at the material and single-cell level. Considering reliability and safety studies early in technology development will facilitate translation of emerging aqueous batteries from the lab to the field.

25 ENERGY STORAGE↗

A Fast‐Charging and High‐Temperature All‐Organic Rechargeable Potassium Battery

Abstract Developing fast‐charging, high‐temperature, and sustainable batteries is critical for the large‐scale deployment of energy storage devices in electric vehicles, grid‐scale electrical energy storage, and high temperature regions. Here, a transition metal‐free all‐organic rechargeable potassium battery (RPB) based on abundant and sustainable organic electrode materials (OEMs) and potassium resources for fast‐charging and high‐temperature applications is demonstrated. N‐doped graphene and a 2.8 m potassium hexafluorophosphate (KPF 6 ) in diethylene glycol dimethyl ether (DEGDME) electrolyte are employed to mitigate the dissolution of OEMs, enhance the electrode conductivity, accommodate large volume change, and form stable solid electrolyte interphase in the all‐organic RPB. At room temperature, the RPB delivers a high specific capacity of 188.1 mAh g −1 at 50 mA g −1 and superior cycle life of 6000 and 50000 cycles at 1 and 5 A g −1 , respectively, demonstrating an ultra‐stable and fast‐charging all‐organic battery. The impressive performance at room temperature is extended to high temperatures, where the high‐mass‐loading (6.5 mg cm −2 ) all‐organic RPB exhibits high‐rate capability up to 2 A g −1 and a long lifetime of 500 cycles at 70–100 °C, demonstrating a superb fast‐charging and high‐temperature battery. The cell configuration demonstrated in this work shows great promise for practical applications of sustainable batteries at extreme conditions.

25 ENERGY STORAGE↗