Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “grid outage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Introducing the 9500 Node Distribution Test System to Support Advanced Power Applications: An Operations-Focused Approach

The 9500 Node Test System is a representative section of distribution power system model developed as a part of the GridAPPS-D™ project, an effort funded by DOE as a part of the Grid Modernization Lab Consortium (GMLC) program. The test system was developed to fulfill a growing need to represent the rapidly evolving state of electric distribution systems by combining elements of legacy infrastructure systems, modern feeder topologies, and an anticipated future with smart grid technologies. It also provides a network model capable of supporting the simulation of operational scenarios such as the ones in a utility distribution control center. This test system allows the evaluation of the performance of advanced power applications in real-time, such as one that simulates the operations of an Advanced Distribution Management Systems (ADMS), Distributed Energy Resource Management Systems (DERMS), etc. in a Distribution control center. This model is an extension of the widely used IEEE 8500 Node Test Feeder and is currently being validated to become an IEEE test case to help increase adoption and widespread usage among both academia and industry. It is a full-size model representative of a section of a utility’s distribution system with multiple feeders fed from different substations. The model includes multiple distribution circuits, a sub-transmission system, multiple substations, behind the meter customer rooftop photovoltaics (PV), and multiple utility-scale distributed energy resources. To enable accurate simulations of operational scenarios, the 9500 Node Test System is designed to support procedure-based operations, with the ability to realistically demonstrate switching operations, feeder reconfiguration, adjustment of volt-var control equipment, dispatch of distributed generation, and response to planned and unplanned outages. The 9500 Node Test System includes three radial distribution feeders with 12.3 MVA of average load, consisting of both medium voltage and low voltage equipment each supplied by a different distribution substation. The three distribution feeders are connected to each other through Normally-Open switches which can be closed when needed to simulate restoration scenarios due to a fault. One feeder represents today’s grid with low penetration of customer-side renewables. The second represents a potential future grid with microgrids and 100% renewable penetration. The third has no customer generation resources, a district steam plant, and a utility-scale solar farm. The three diverse circuits were created to allow the simulation of both today’s situation as well as potential future scenarios. All three feeders have customers connected by low-voltage secondary triplex lines. This test system meets all requirements outlined in the report for creating a simulation environment that would enable discussion between key technical stakeholders as well as having the potential to accelerate operational application development and their subsequent testing and integration. The new model is a possible representation of what we believe the distribution grid may look like in the future: a high penetration of renewables, reconfigurable radial and mesh topology, numerous DERs, islanded microgrids, and significantly increased data and measurement density. The system supports both the solution of existing and newer algorithms but also enables the evaluation of applications in a realistic operational environment defined by task oriented procedural steps that represent the interaction between the control center operator and field personnel.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Protection System Validation Using Post-Event Anomaly Classification with Machine Learning

Power system protection devices have transitioned over the past few decades from mechanical to analog devices, then to solid state and finally digital. Relays and their associated critical network of equipment have significantly increased in complexity. Even internally, relays have gained significant intricacy, with relatively simple overcurrent or differential functions now being assisted by a myriad of other functions. This is necessary as the grid becomes more complex, but it brings increased difficulty in monitoring and upkeep. Misoperation caused by improper relay settings or malicious actions is a constant challenge faced by all utilities. These improper settings can be difficult to identify and may require exhaustive post-mortem analysis, typically after a major outage event has already occurred. A mechanism is needed for monitoring the behavior of protection systems to validate that they act and perform as expected. This work presents a concept for a machine learning (ML) system capable of validating the performance of protection systems by classifying anomalous events and characterizing protection system responses based solely on available current and voltage measurements. As a first step in its development, an experimental dataset is generated, and a random forest model is implemented with high accuracy in distinguishing four power system scenarios.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Protection System Validation with Machine Learning Anomaly Classification

A poster for the Early Career Poster Session. Power system protection devices have transitioned over the past few decades from mechanical to analog devices, then to solid state and finally digital. Relays and their associated critical network of equipment have significantly increased in complexity. Even internally, relays have gained significant intricacy, with relatively simple overcurrent or differential functions now being assisted by a myriad of other functions. This is necessary as the grid becomes more complex, but it brings increased difficulty in monitoring and upkeep. Misoperation caused by improper relay settings or malicious actions is a constant challenge faced by all utilities. These improper settings can be difficult to identify and may require exhaustive post-mortem analysis, typically after a major outage event has already occurred. A mechanism is needed for monitoring the behavior of protection systems to validate that they act and perform as expected. This work presents a concept for a machine learning (ML) system capable of validating the performance of protection systems by classifying anomalous events and characterizing protection system responses based solely on available current and voltage measurements. As a first step in its development, an experimental dataset is generated, and a random forest model is implemented with high accuracy in distinguishing four power system scenarios.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Ambient energy for buildings: Beyond energy efficiency

The following Key Messages comprise the salient findings of this study: 1. Ambient energy (from sun, air, ground, and sky) can heat and cool buildings; provide hot water, ventilation and daylighting; dry clothes; and cook food. These services account for about three-quarters of building energy consumption and a third of total US demand. Biophilic design (direct and indirect connections with nature) is an intrinsic adjunct to ambient energy systems, and improves wellness and human performance. 2. The current strategy of electrification and energy efficiency for buildings will not meet our climate goals, because the transition to an all-renewable electric grid is too slow. Widespread adoption of ambient energy is needed. Solar-heated buildings also flatten the seasonal demand for electricity compared to all-electric buildings, reducing required production capacity and long-term energy storage. In addition, ambient-conditioned buildings improve resilience by remaining livable during power outages. 3. National policies, incentives, and marketing should be enacted to promote ambient energy use. Federal administrative priorities should reflect the importance of ambient energy for buildings. Use of ambient energy should be encouraged through existing and new building codes and standards. 4. Ambient energy system design tools are needed for architects, engineers, builders, building scientists, realtors, appraisers, and consumers. PVWatts is used over 100 million times per year for photovoltaic system design. A similar, simple, and accessible tool for ambient design is crucial. 5. Training on ambient energy is needed throughout secondary, post-secondary, and continuing education for workforce development. Currently, only about 10% of colleges teach courses on passive heating and cooling systems. 6. Ambient-conditioned buildings should be demonstrated in all US climate zones. Performance should be monitored and reported, with quantitative case studies made widely available. 7. While current technology is sufficient to build high-performance ambient buildings now, research is needed to develop new technologies to harness ambient energy more effectively and more economically. Such advancements will facilitate adoption of ambient energy technologies in a wider range of buildings, including retrofits. Examples include windows with much lower thermal losses, use of the building shell as thermal storage, alternative light-weight thermal storage systems, sky radiation cooling systems, automated controls for solar gains and passive cooling, and ground coupling.

14 SOLAR ENERGY↗

Post-Event Fault Identification with Machine Learning for Protection System Validation

Power system protection devices have transitioned over the past few decades from mechanical to analog devices, then to solid state and finally digital. Relays and their associated critical network of equipment have significantly increased in complexity. Even internally, relays have gained significant intricacy, with relatively simple overcurrent or differential functions now being assisted by a myriad of other functions. This is necessary as the grid becomes more complex, but it brings increased difficulty in monitoring and upkeep. Misoperation caused by accidental improper relay settings or deliberate malicious actions is a constant challenge faced by all utilities. These improper settings can be difficult to identify and may require exhaustive post-mortem analysis, typically after a major outage event has already occurred. A mechanism is needed for monitoring the behavior of protection systems to validate that their performance falls within expectations. Relays that fail to isolate a fault or trip when there is no system disturbance can be flagged for settings review in situations where this behavior may not have been noticed due to manual restoration or backup protection operations. This work presents a concept for a machine learning (ML) system capable of validating the performance of protection systems by identifying fault events and characterizing protection system responses based solely on available current and voltage measurements. As a first step in its development, an experimental dataset is generated, and a random forest model is implemented with high accuracy in distinguishing four power system scenarios.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Policy and Regulatory Environment for Utility-Scale Energy Storage: Bangladesh

Bangladesh has experienced significant economic growth and poverty reduction over the past several decades. Recognizing the central role electricity plays in economic development, the Government of Bangladesh (GOB) has established policies to accelerate the growth of the electric power sector. The Bangladesh power grid is transforming into one marked by declining reliance on domestic natural gas reserves and oil-based rental power plants, increasing renewable energy contribution, and shifting demand patterns. The GOB is now reconsidering its prior plans to increase the share of coal capacity in the generation mix to meet demand, shifting its focus instead to electricity imports from neighboring countries, nuclear generation, liquified natural gas imports, and domestic renewable resources such as wind and solar. However, investments in the transmission and distribution system, as well as ancillary services, have not kept pace with investments in generation resources over the past decade. Thus, Bangladesh electricity consumers still experience outages and poor power quality despite adequate installed capacity. On the demand side, population growth and industrialization have fueled steady growth in electricity consumption as efforts to expand access to electricity enabled near-universal electricity access by mid-2020. The combined changes in the mix of generation resources and patterns of electricity demand present new challenges and opportunities in operating and maintaining a reliable power system. Energy storage has the potential to help meet these challenges and accelerate Bangladesh’s energy transition. Declining costs for some energy storage technologies make them increasingly cost-effective solutions to provide a wide range of grid services. Previous analyses of energy storage in the region have identified several potential applications for storage at the bulk system level, including energy arbitrage, ancillary services, and transmission network support. The potential for storage to meet these needs depends on many factors, including physical characteristics of the power system and the policy and regulatory environments in which these energy storage assets would operate. This report applies an Energy Storage Readiness Assessment the National Renewable Energy Laboratory developed for policy makers and regulators to identify priority areas of focus as they continue to develop the appropriate suite of policies, programs, and regulations to enable storage deployment. This assessment uses a simple evaluation scheme to identify the barriers and opportunities for utility-scale energy storage within Bangladesh’s policy and regulatory environment.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An Evaluation of the Economic and Resilience Benefits of a Microgrid in Northampton, Massachusetts

Recent developments and advances in distributed energy resource (DER) technologies make them valuable assets in microgrids. This paper presents an innovative evaluation framework for microgrid assets to capture economic benefits from various grid and behind-the-meter services in grid-connecting mode and resilience benefits in islanding mode. In particular, a linear programming formulation is used to model different services and DER operational constraints to determine the optimal DER dispatch to maximize economic benefits. For the resiliency analysis, a stochastic evaluation procedure is proposed to explicitly quantify the microgrid survivability against a random outage, considering uncertainties associated with photovoltaic (PV) generation, system load, and distributed generator failures. Optimal coordination strategies are developed to minimize unserved energy and improve system survivability, considering different levels of system connectedness. The proposed framework has been applied to evaluate a proposed microgrid in Northampton, Massachusetts that would link the Northampton Department of Public Works, Cooley Dickenson Hospital, and Smith Vocational Area High School. The findings of this analysis indicate that over a 20-year economic life, a 441 kW/441 kWh battery energy storage system, and 386 kW PV solar array can generate $2.5 million in present value benefits, yielding a 1.16 return on investment ratio. Results of this study also show that forming a microgrid generally improves system survivability, but the resilience performance of individual facilities varies depending on power-sharing strategies.

25 ENERGY STORAGE↗

Analysis and design of DC-link capacitor in cascaded H-bridge multilevel active front-end converter

Medium-voltage grid-tied systems often use a cascaded H-bridge multi-level active front-end. In this converter, dc link bus capacitors play an important role in stabilizing the converter and enabling both active and reactive power injections. The present work provides analytical expressions for the capacitor current, which are essential for optimizing system design (especially capacitor size vs. lifetime). Then, the expression is incorporated into the grid connected bidirectional power system model. Consequently, this work contributes to the guiding principles to choose accurate dc link capacitor ratings against grid-side power delivery requirements. DC-link capacitors come with an expiration date which is dependent on the operating power and voltage values. Lack of information about the lifetime of the dc-link capacitor creates uncertainty in the duration of online operation of the converter, thus increasing the probability of a contingency outage. The lifetime of the capacitor can range from only a few seconds of online operation of the station due to under-sizing, to a compromised quality of power flowing through other solid state devices which may not have been designed for the transients that are caused by over-sizing of the dc-link capacitor. A better estimate of the lifetime of these capacitors can help maximize usage and maintain scheduled outages more efficiently, without disruption in service.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Implementing a Terrestrial Timing Solution: Best Practices

This document is an overview and guide on the concept of precision time and how an alternative terrestrial timing solution to the Global Positioning System (GPS) can be implemented. What follows is a set of recommendations and best practices, derived from research at Oak Ridge National Laboratory (ORNL), across industry, and within the U.S. government, to implement a system of precision timing synchronization to support resilient operations for the U.S. grid. Precision time is a fundamental necessity for operating the grid today, and it becomes even more important as the grid modernizes with clean energy sources, microgrids, and precision sensors placed throughout the grid system to ensure failureresistant operations. The Global Navigation Satellite System (GNSS), which includes (GPS), is currently the primary provider of precision timing today. A terrestrial-based system for time delivery and synchronization to augment GPS is outlined below and it would provide secure time, synchronized with Coordinated Universal Time (UTC), in the event of outages or other interruptions associated with time delivery.

47 OTHER INSTRUMENTATION↗

Long-Term Impacts of Constrained Transmission Deployment on the Cost-Reliability Tradeoff

Traditional Resource Adequacy (RA) frameworks in the U.S. undervalue the contributions of inter-regional transmission to resource adequacy during stress periods, focusing on the availability of nameplate capacity instead. However, availability of nameplate capacity does not always translate into electricity delivery, especially during tail events. Moreover, the rapid deployment of energy-limited resources and increasing electricity demand challenge existing resource adequacy frameworks and couple regional electricity demand and availability of supply via transmission. We propose a two-stage framework that goes beyond the existing capacity-centered approaches to reveal the RA contributions of transmission. In the first stage we introduce a multi-objective optimization framework to quantify the merits of transmission expansion via Pareto Frontiers under alternative futures of no transmission investment, primary energy resources availability and demand growth. The second stage focuses on tail events and leverages the results of the first stage to characterize the risk profile of regional consumers across the U.S. under the alternative energy futures. We find that no new transmission can lead to a more expensive and less reliable national grid across scenarios, however, the impact on regional RA can vary. The probabilistic analysis reveals that transmission investments can alleviate the tail risk of consumers, however, the availability of fuel resources does not always alleviate regional tail risks. Our findings inform policymakers and utilities on the prioritization of transmission investments to mitigate the risk of widespread outages, also for tail events, and ensure reliable and affordable electricity delivery to all.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Economic Dispatch Optimization of Multi-Unit SMR Site

With the increase of integration of variable renewable into the grid, grid resilience can be compromised without flexible electricity suppliers. Flexible operation of NPP can expand the scope of integration of new nuclear power plants in regions with high share of renewables. It also provides opportunity to increase profits through participation in ancillary services. In this research, NuScale modules are used as the case study. NuScale is an integrated pressurized water reactor with thermal power of 250 MWth. Having multiple units can provide higher flexibility in changing power levels and supplying the grid with electricity all year long. Additionally, load-following might perturbate the ordered sequence of refueling (every 24 months for NuScale). To maintain the 2 year refueling cycles, the loading patterns will need to be adjusted in a year-to-year basis, resulting in additional unnecessary costs. Another solution is to find the optimal outage schedule. This will also shift the focus of the planned outage to a more optimized predictive outages and maintenance. Results from short-term optimization (i.e., daily participation in energy and ancillary services markets) shows that average commitment to regulation down ancillary service markets during late night and early morning hours can increase revenues. Participating in upward reserves during pre-work commuting hours and early evening hours can also generate additional revenues due to high ramp up of electricity demand. Having multiple units at a single site can also help operate flexibly. Results from long-term optimization show that daily fluctuation in electric power is usually handled by few units while other units operate on base-load profile. It is possible to combine base-load operation with flexible operation to extend component remaining useful life in some units and find optimal outage schedule for the units.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Rapid Evaluation and Response to Impacts on Critical End-Use Loads Following Natural Hazard-Driven Power Outages: A Modular and Responsive Geospatial Technology

The disparate nature of data for electric power utilities complicates the emergency recovery and response process. The reduced efficiency of response to natural hazards and disasters can extend the time that electrical service is not available for critical end-use loads, and in extreme events, leave the public without power for extended periods. This article presents a methodology for the development of a semantic data model for power systems and the integration of electrical grid topology, population, and electric distribution line reliability indices into a unified, cloud-based, serverless framework that supports power system operations in response to extreme events. An iterative and pragmatic approach to working with large and disparate datasets of different formats and types resulted in improved application runtime and efficiency, which is important to consider in real time decision-making processes during hurricanes and similar catastrophic events. This technology was developed initially for Puerto Rico, following extreme hurricane and earthquake events in 2017 and 2020, but is applicable to utilities around the world. Given the highly abstract and modular design approach, this technology is equally applicable to any geographic region and similar natural hazard events. In addition to a review of the requirements, development, and deployment of this framework, technical aspects related to application performance and response time are highlighted.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Capacity contributions of Southern Oregon offshore wind to the Pacific Northwest and California

Variable renewable energy generation poses unique capacity challenges, which increasingly depend on weather events at varying timescales. Facilitated by transmission planning, geographic and technological diversity of the generation fleet may provide a mitigation to capacity shortfalls. In this work, offshore wind (OSW) energy is sited in the areas off the West Coast between Coos Bay, Oregon, and Crescent City, California. Three generation and transmission scenarios are modeled within the Western Interconnection: (i) 3.4 gigawatts (GW) of installed OSW capacity connected to Southern Oregon through a High Voltage Alternating Current (HVAC) Radial Topology in 2030; (ii) 12.9 GW of installed OSW capacity connected to Washington, Oregon, and California through a High Voltage Direct Current (HVDC) Radial Topology post-2030, and (iii) the same 12.9 GW connected to the same locations through a Multi-terminal DC (MTDC) Backbone Topology post-2030. Zonal dispatch simulations assuming coincident wind, solar, and hydropower production and loads over 18 meteorological years, accounting for temperature-dependent equipment derating and forced outages, serve as inputs to the Associated System Capacity Contribution (ASCC) methodology. The capacity credit is 33%, 25% and 34% for the 2030 HVAC Radial Topology, 2030+ HVDC Radial Topology, and 2030+ MTDC Backbone Topology, respectively. Transmission design is shown to mitigate the typical erosion of marginal capacity contribution as more OSW is developed, underscoring the opportunity for grid modernization while decarbonizing the generation mix.

17 WIND ENERGY↗

Grid Interactive Micro-Distributed Refrigerated Display Case

Open-vertical medium-temperature refrigerated display cases comprise nearly 50% of total case lineups in a typical supermarket, with more than 80% of their cooling load attributed to infiltration of warm and moist air from the surrounding space. The infiltration takes place across the air curtain system of the display case. While the air curtain acts as a thermal shield and as a cooling mechanism to maintain product temperature, it also entrains large amounts of heat and moisture from the adjacent space. Additionally, from food safety and quality standpoints, these fixtures are vulnerable to electric outages and traditionally cannot participate in load flexibility events. This paper describes key features of an innovative design of a self-contained, water-cooled, medium-temperature, open-vertical display case. The novel concept will eliminate the inefficient air curtain system and incorporate a hybrid radiant and low-airflow convective cooling design with a thermal-energy-storage-coupled heat exchanger integrated into the refrigeration circuit. The focus of this paper is on evaluating the thermal performance of the novel hybrid design in maintaining target product temperature. It presents thermal performance findings from thermo-fluid system modeling and robust state-of-the-art laboratory experiments used to validate those models. Load flexibility attributes from thermal energy storage are not discussed. A controlled-environment chamber at the National Renewable Energy Laboratory was leveraged to validate the thermal performance of the novel technology. Final results from bench-scale experiments indicate the proposed design maintained mean product temperatures within food safety guidelines.

commercial refrigeration↗

Smart-DS: Synthetic Models for Advanced, Realistic Testing: Distribution Systems and Scenarios

The explosion of new ideas for distributed energy resources and advanced distribution grid algorithms faces a critical challenge: how can one effectively develop and evaluate these breakthrough technologies without an adequate set of power systems network, load, and resource data to test against? Today's open test systems, particularly for distribution systems, are tiny and incomplete; and though with enough effort, obtaining utility data under NDA can overcome scale challenges, the results can't be openly shared, preventing fair comparison. The Smart-DS project-led by NREL in partnership with MIT, Universidad Pontificia Comillas, CYME, and EDD-is working to overcome this gap by generating multiple large-scale, open, synthetic, distribution systems that are realistic but not real. These datasets go beyond a single medium voltage feeder (~1000 customers) to cover entire metropolitan areas and their surrounds with up to hundreds of feeders and millions of customers, complete with low voltage customer connections and high voltage sub-transmission. This scale allows adequate testing and analysis of not just local controls and advanced DERs, but also multiple substation interactions, optimized switching, full-scale distribution-OPF, and more. To accompany these datasets, the project is also building a rich set of scenario generation tools that can be used for distribution and transmission systems alike. This includes automated, spatially aware access to world-class, high-resolution solar, wind, and weather data: forward looking generation mixes: and highly configurable DER, load, climate, outage, control-scheme, and other scenarios. We will also highlight DiTTo, an exciting open-source, multi-way distribution dataset transformation tool for many-to-many format translation with scenario, merge/split, and many other manipulation capabilities.

DERs↗

Real-time power management technique for microgrid with flexible boundaries

In order to diminish the impacts brought by high penetration of renewable energy on the reliability of distribution systems, some distribution networks (e.g. Chattanooga electric power board system) have deployed smart switches (SSs) to island some areas to mitigate outage losses. However, due to intermittency and sharply changing rate of renewable energy, it is likely to experience insufficient or excessive power for islanded areas. Therefore, a microgrid controller featured with flexible boundaries is proposed. With proposed microgrid controller, the microgrid can not only shrink or expand its boundaries according to current renewable energy supply, but also disconnect/connect to the main grid with a designated SS. Furthermore, to ensure the microgrid controller could obtain suitable boundaries on the time scale of seconds, a real-time power management technique with alternative generating algorithm is designed to generate all possible alternative boundaries and choose the optimal one, which is scalable to any topology. In addition, in order to maintain state of charge of batteries within a desirable range, anti-overcharge/discharge strategies are designed. Four comprehensive experiments verify that the implementation of the microgrid controllers can realise flexible boundaries and deal with sharply changing rate of renewable generation or load on the time scale of seconds.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Integration of equitable resilience metrics into climate-informed electric utility planning processes: phase one

Working together, Sandia National Laboratories, Southern California Edison (SCE) - an Investor-Owned Utility (IOU) - and the California Public Utilities Commission (CPUC) are studying how electric utilities can use equity and resilience metrics to help inform the prioritization and sequencing of resilience-driven infrastructure investments. To this end, this project evaluated “Social Burden,” an equitable resilience metric which measures the potential impact of disruptions in access to non-electric critical services on people and estimates community resilience to these disruptions. The Social Burden was expanded to incorporate SCE’s existing equity metric and applied to evaluate the potential impacts from a range of climate-informed hypothetical outage scenarios developed under SCE’s 2022 Climate Adaptation Vulnerability Assessment. One baseline (“blue-sky”) state and eight different outage scenarios were evaluated to measure the potential impacts of the outages on non-electric infrastructure, critical services, and people. Key findings include: 1) the Social Burden framework is flexible enough to adapt to and build upon existing utility equity and/or resilience metrics, 2) Social Burden results highlight the high degree of non-electric service redundancy within the SCE service area with most (6/8) hypothetical outage scenarios predicted to increase people’s Social Burden by less than 10%; however, 3) access to critical services and people’s ability to obtain them is unequal and spatially clustered, meaning that there are some hypothetical outage scenarios (2/8) that will exert a higher toll on communities directly experiencing the outage as well as some nearby communities with pre-existing vulnerabilities. The report concludes with recommendations for potential use cases of the expanded Social Burden metric and identifies priority follow-on work. Potential use cases may include incorporating equity into IOU’s prioritization of climate resilience investments. Additionally, Social Burden analysis may provide additional data and insights to augment grid planning, potentially by identifying additional needs and/or prioritizing previously identified needs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Near-Real-Time Model for Predicting Electricity Disruptions in Texas During Winter Storms

There has been an increase in extreme weather events, posing a threat to power grid systems, potentially influenced by factors such as population growth, changes in ecosystems, land cover, and land use in the service area, as well as the growth of certain vegetation types. This research seeks to develop a predictive model to mitigate potential damages caused by future winter storms. This research utilizes the Light Gradient Boosting Machine (LightGBM), incorporating the number of power outages experienced at the county level, geographic details, weather information, and lagged outage and lagged weather data. The developed models were broadly divided into two groups, with six models in each group - one group without optimization and another with optimization, totaling 12 trained models. For model optimization, Bayesian optimization was employed using Root Mean Squared Error (RMSE) as the objective function. In results, when comparing Group 2 (the optimized group) with Group 1 (the non-optimized group), it was found that optimization did not always lead to a reduction in RMSE and Mean Absolute Error (MAE). However, in terms of Mean Directional Accuracy (MDA), while all results in Group 1 were below the baseline accuracy of 0.33, all results in Group 2 exceeded 0.33, with some cases showing an increase of more than three times the baseline. The results indicated that, in the optimized model group, Population and Pressure were the most influential factors when using current weather data and geographical information. When using lagged data, lagged recorded outages and lagged Pressure emerged as the most significant factors. Among the 12 developed models, the L-1-2-O model showed the lowest RMSE and MAE, as well as the highest accuracy, with values of 390.62 households and 168.13 households, respectively. To normalize the RMSE and MAE values, each metric was divided by the average number of households among the counties in Texas. For the L-1-2-O model, the scaled RMSE was 0.88% and the scaled MAE was 0.38%. In terms of MDA, which indicates the accuracy of the prediction direction, the L-1-O model achieved the highest score of 0.41. Although this study focused on Texas, which suffered the greatest impact from the winter storms in 2021, with additional validation, the methodology used in this research could be applied to other regions.

Lee, Jangjae [Texas A & M Univ., College Station, ↗