Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “gas storage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Techno-Economic Analysis and Optimization of a Compressed-Air Energy Storage System Integrated with a Natural Gas Combined-Cycle Plant

To address the rising electricity demand and greenhouse gas concentration in the environment, considerable effort is being carried out across the globe on installing and operating renewable energy sources. However, the renewable energy production is affected by diurnal and seasonal variability. To ensure that the electric grid remains reliable and resilient even for the high penetration of renewables into the grid, various types of energy storage systems are being investigated. In this paper, a compressed-air energy storage (CAES) system integrated with a natural gas combined-cycle (NGCC) power plant is investigated where air is extracted from the gas turbine compressor or injected back into the gas turbine combustor when it is optimal to do so. First-principles dynamic models of the NGCC plant and CAES are developed along with the development of an economic model. The dynamic optimization of the integrated system is undertaken in the Python/Pyomo platform for maximizing the net present value (NPV). NPV optimization is undertaken for 14 regions/cases considering year-long locational marginal price (LMP) data with a 1 h interval. Design variables such as the storage capacity and storage pressure, as well as the operating variables such as the power plant load, air injection rate, and air extraction rate, are optimized. Results show that the integrated CAES system has a higher NPV than the NGCC-only system for all 14 regions, thus indicating the potential deployment of the integrated system under the assumption of the availability of caverns in close proximity to the NGCC plant. The levelized cost of storage is found to be in the range of 136–145 $/MWh. Roundtrip efficiency is found to be between 74.6–82.5%. A sensitivity study with respect to LMP shows that the LMP profile has a significant impact on the extent of air injection/extraction while capital expenditure reduction has a negligible effect.

25 ENERGY STORAGE↗

Electromethanogenesis reactor

Generation of energy and storage of energy for subsequent use is provided by electromethanogenesis of carbon dioxide into a fuel gas and the storage of the fuel gas for subsequent use. An electromethanogenic reactor includes an anode conductor and a cathode conductor wherein the cathode conductor includes submicron to micron scale pores. Electromethanogenesis microbes and/or enzymes are located in the micron scale pores of the cathode electrode conductor. Carbon dioxide is introduced into the electromethanogenic reactor and the electromethanogenesis microbes/enzymes and the carbon dioxide interact and produce a fuel gas. The fuel gas is stored for subsequent use, for example use in power generation.

Knipe, Jennifer Marie↗

Electromethanogenesis reactor

Generation of energy and storage of energy for subsequent use is provided by electromethanogenesis of carbon dioxide into a fuel gas and the storage of the fuel gas for subsequent use. An electromethanogenic reactor includes an anode conductor and a cathode conductor wherein the cathode conductor includes submicron to micron scale pores. Electromethanogenesis microbes and/or enzymes are located in the micron scale pores of the cathode electrode conductor. Carbon dioxide is introduced into the electromethanogenic reactor and the electromethanogenesis microbes/enzymes and the carbon dioxide interact and produce a fuel gas. The fuel gas is stored for subsequent use, for example use in power generation.

Knipe, Jennifer Marie↗

Evaluating degradation of CO 2 adsorbents in flue gas from bioenergy with carbon capture and storage

For this work, the potential degradation of CO 2 adsorbents in Bioenergy with Carbon Capture and Storage (BECCS) was investigated through direct exposure to biomass combustion flue gas. Pre- and post-exposure characterization after 6–12 hours of exposure provided valuable insight into how common adsorbents would realistically perform in a BECCS process. The stability of zeolites and robust ZIFs was confirmed, but some unanticipated degradation mechanisms of less-stable MOFs and amine-based materials were also revealed, including pore fouling and chemical poisoning. The results emphasize the need for stability evaluations of adsorbents in comprehensive flue gas mixtures and suggest relationships between sorbent structure and degradation mechanism and extent.

09 BIOMASS FUELS↗

Regulations, Codes, and Standards Review for Underground Hydrogen Storage

Hydrogen continues to show promise as a viable contributor to achieving energy storage goals such as energy security and decarbonization in the United States. However, many new and expanded hydrogen use applications will require identifying methods of larger-scale storage than the solutions that currently exist for smaller storage applications. One possibility is to store large quantities of gaseous hydrogen below ground level. Underground storage of other fuels such as natural gas is already currently utilized, so much of the infrastructure and basic technologies can be used as a basis for underground hydrogen storage (UHS). A few commercial UHS facilities currently exist in the United States, including salt caverns owned and operated by Air Liquide, Linde, and Conoco Philips, but UHS is still a relatively new concept that has not been widely deployed. It is necessary to understand the safety risks and hazards associated with UHS before its use can be expanded and accepted more broadly. Many of these risks are addressed through regulations, codes, and standards (RCS) issued by governing bodies and organizations with expertise in certain hazards. This report is a review of RCS documents relevant to UHS, with a particular lens on potential technical gaps in existing guidance. These gaps may be specific to the physical properties of hydrogen or due to the different technologies relevant for hydrogen vs. natural gas storage. This is meant to be a high-level review to identify relevant documents and potential gaps. Formally addressing the individual gaps identified here within the codes and standards themselves would involve a more intensive analysis and differ based on the code or standard revision processes of the various publishing organizations. Therefore, presenting specific recommendations for revising the verbiage of the documents for UHS applications is left for future work and other publications.

08 HYDROGEN↗

Multi–Modular Design of Stable Pore–Space–Partitioned Metal–Organic Frameworks for Gas Separation Applications

Pore space partition (PSP) is an effective materials design method for developing high-performance small-pore materials for storage and separation of gas molecules. The continued success of PSP depends on broad availability and judicious choice of pore-partition ligands and better understanding of each structural module on stability and sorption properties. Here, by using substructural bioisosteric strategy (sub-BIS), a dramatic expansion of pore-partitioned materials is targeted by using ditopic dipyridyl ligands with non-aromatic cores or extenders, as well as by expanding heterometallic clusters to uncommon nickel–vanadium and nickel–indium clusters rarely known before in porous materials. The dual-module iterative refinement of pore-partition ligands and trimers leads to remarkable enhancement of chemical stability and porosity. Here a family of 23 pore-partitioned materials synthesized from five pore-partition ligands and seven types of trimeric clusters is reported. New materials with such compositionally and structurally diverse framework modules reveal key factors that dictate stability, porosity, and gas separation properties. Among these, materials based on heterometallic vanadium–nickel trimeric clusters give rise to the highest long-term hydrolytic stability and remarkable uptake capacity for CO 2 , C 2 H 2 /C 2 H 4 /C 2 H 6 , and C 3 H 6 /C 3 H 8 hydrocarbon gases. Here, the breakthrough experiment shows the potential application of new materials for separating gas mixtures such as C 2 H 2 /CO 2 .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Liquid Air Combined Cycle TM for Power and Storage

Liquid Air Combined Cycle (LACC) is a hybrid liquid air energy storage (LAES) system combining energy storage with a combustion turbine to enable large-scale, long-duration energy storage (LDES) while reducing fuel intensity compared to the current state-of-the-art. The LACC technical approach employs proven equipment (cryogenic refrigeration, storage, tanks, pumps, gas turbines, exhaust heat recovery equipment, and turbines) to limit technical risk to a novel organic Rankine cycle (ORC), which was evaluated during this project and found to be feasible. Moreover, LACC storage is safe and relatively compact, to facilitate siting close to loads and within metropolitan regions. The air storage medium is freely available and eliminates supply chain constraints. LACC uses cryogenic air as a storage medium and a gas turbine as the source of heat to drive the discharge process. LACC is distinguished from other LAES technologies by several factors. The charge and discharge processes are decoupled so that cryogenic liquid air is the only storage medium. Other systems also store the higher temperature thermal energy from the liquefaction process in an additional medium. Subsequently, LACC focuses on maximization of the discharge energy and power. LACC also permits the use of commercially available cryogenic refrigeration and storage technologies to increase competition. This project identified product requirements to support market entry and commercialization of the LACC in modular units of approximately 117 MW, each drawing liquid air from customary cryogenic storage tanks capable of storing 75 GWh of dispatchable energy, more than pumped storage hydro or compressed air energy storage technologies. An economic analysis identified the specific liquid air consumption (quantity of liquid air per unit of discharge energy) as a critical parameter. Minimizing the air consumption reduces the specific capital cost ($\$ $/kW) for charging and discharging equipment by reducing the size of piping and turbomachinery. Likewise, the specific cost of energy capacity ($\$ $/kWh) is reduced by increasing the energy deliverable from a given size tank. The cycle was analyzed to identify the optimal equipment selection and operating conditions, which in turn were combined with quotes and cost estimates to calculate the cost of energy from an LACC system. A substantial effort was focused on the ORC, which draws low-temperature heat from the gas turbine exhaust and condenses at low temperature using the cryogenic liquid air as a heat sink. Alternative turbomachinery arrangements were evaluated for feasibility and cost. A technology maturation plan lays out a low-risk approach to development of the novel ORC components and demonstration of LACC technology at pilot scale.

25 ENERGY STORAGE↗

Hydrogen Energy Storage System at Borrego Springs Towards an H2 Enabled 100 Renewable Microgrid

San Diego Gas & Electric's Borrego Springs Microgrid is one of the largest microgrids in the USA, serving 2500 residential customers, 300 commercial and industrial customers, and has a peak demand of approximately 14 MW. This microgrid is located at the end of a long transmission line, and is subjected to extreme weather events like storms, wildfires, and flooding, which frequently cause grid outages. The microgrid currently relies on 3.65 MW of diesel-powered generators to provide grid-forming services during these outages, which results in greenhouse gas and criteria pollutant emissions. However, the microgrid has access to approximately 37 MW of installed solar generation and struggles with overgeneration and curtailment. 1.5 MW/4.5 MWh of grid-scale batteries have been installed to capture some the overgeneration and provide resiliency, but a longer-duration low-greenhouse gas emission energy storage solution is needed. In our project, the team will evaluate in the lab and demonstrate in the field a grid-forming fuel cell inverter that can provide grid-forming services while utilizing hydrogen's energy storage scalability. We will first utilize NREL's Renewable Energy Integration and Optimization (REopt) platform to perform analyses on future microgrid scenarios that use hydrogen assets to reduce or eliminate the need for diesel backup generators. We will then evaluate the grid-forming inverter through power hardware-in-the-loop and controller hardware-in-the-loop experiments at ARIES, and de-risk the field deployment and operation of hydrogen assets in the microgrid setting. Finally, this project will demonstrate the operation of the fuel cell inverter and updated microgrid controller by operating in grid-forming mode in the Borrego Springs microgrid.

Borrego Springs↗

Hydrogen Energy Storage System at Borrego Springs Towards an H2 Enabled 100% Renewable Microgrid

San Diego Gas & Electric's Borrego Springs Microgrid is one of the largest microgrids in the USA, serving 2500 residential customers, 300 commercial and industrial customers, and has a peak demand of approximately 14 MW. This microgrid is located at the end of a long transmission line, and is subjected to extreme weather events like storms, wildfires, and flooding, which frequently cause grid outages. The microgrid currently relies on 3.65 MW of diesel-powered generators to provide grid-forming services during these outages, which results in greenhouse gas and criteria pollutant emissions. However, the microgrid has access to approximately 37 MW of installed solar generation and struggles with overgeneration and curtailment. 1.5 MW/4.5 MWh of grid-scale batteries have been installed to capture some the overgeneration and provide resiliency, but a longer-duration low-greenhouse gas emission energy storage solution is needed. In our project, the team will evaluate in the lab and demonstrate in the field a grid-forming fuel cell inverter that can provide grid-forming services while utilizing hydrogen's energy storage scalability. We will first utilize NREL's Renewable Energy Integration and Optimization (REopt) platform to perform analyses on future microgrid scenarios that use hydrogen assets to reduce or eliminate the need for diesel backup generators. We will then evaluate the grid-forming inverter through power hardware-in-the-loop and controller hardware-in-the-loop experiments at ARIES, and de-risk the field deployment and operation of hydrogen assets in the microgrid setting. Finally, this project will demonstrate the operation of the fuel cell inverter and updated microgrid controller by operating in grid-forming mode in the Borrego Springs microgrid.

blackstart with fuel cells↗

Cryogenic Transport of High-Pressure-System Recharge Gas

A method of relatively safe, compact, efficient recharging of a high-pressure room-temperature gas supply has been proposed. In this method, the gas would be liquefied at the source for transport as a cryogenic fluid at or slightly above atmospheric pressure. Upon reaching the destination, a simple heating/expansion process would be used to (1) convert the transported cryogenic fluid to the room-temperature, high-pressure gaseous form in which it is intended to be utilized and (2) transfer the resulting gas to the storage tank of the system to be recharged. In conventional practice for recharging high-pressure-gas systems, gases are transported at room temperature in high-pressure tanks. For recharging a given system to a specified pressure, a transport tank must contain the recharge gas at a much higher pressure. At the destination, the transport tank is connected to the system storage tank to be recharged, and the pressures in the transport tank and the system storage tank are allowed to equalize. One major disadvantage of the conventional approach is that the high transport pressure poses a hazard. Another disadvantage is the waste of a significant amount of recharge gas. Because the transport tank is disconnected from the system storage tank when it is at the specified system recharge pressure, the transport tank still contains a significant amount of recharge gas (typically on the order of half of the amount transported) that cannot be used. In the proposed method, the cryogenic fluid would be transported in a suitably thermally insulated tank that would be capable of withstanding the recharge pressure of the destination tank. The tank would be equipped with quick-disconnect fluid-transfer fittings and with a low-power electric heater (which would not be used during transport). In preparation for transport, a relief valve would be attached via one of the quick-disconnect fittings (see figure). During transport, the interior of the tank would be kept at a near-ambient pressure far below the recharge pressure. As leakage of heat into the tank caused vaporization of the cryogenic fluid, the resulting gas would be vented through the relief valve, which would be set to maintain the pressure in the tank at the transport value. Inasmuch as the density of a cryogenic fluid at atmospheric pressure greatly exceeds that of the corresponding gas in a practical high-pressure tank at room temperature, a tank for transporting a given mass of gas according to the proposed method could be smaller (and, hence, less massive) than is a tank needed for transporting the same mass of gas according to the conventional method.

Ungar, Eugene K,↗

Detectability of anthropogenic impacts on terrestrial carbon storage through space-based greenhouse gas observations

While changes in human activity and their impact on the terrestrial biosphere may be apparent in inventory and land-surface satellite data, reliably matching these changes to signals in atmospheric greenhouse gases remains challenging. The dominant signals in atmospheric carbon dioxide (CO2) are those of the seasonal and diurnal variability of the terrestrial biosphere. As a result, the historically large short-term change in anthropogenic fossil fuel emissions due to COVID-19 produced an atmospheric CO2 signal near the threshold of detectability of the current space-based observing system. Impacts of anthropogenic activity on terrestrial carbon storage are likewise expected to be difficult, if not impossible, to detect and validate with atmospheric observations. For example, many forest management projects involve reduction of wood removals that would otherwise be taken off site and decompose years later and are thus not reflected in immediate onsite carbon fluxes. Nevertheless, changes implemented over a jurisdictional scale, as opposed to individual projects, may be detectable. This presentation will analyze to what extent NASA’s Goddard Earth Observing System (GEOS)/Orbiting Carbon Observatory 2 (OCO-2) assimilated column CO2 (XCO2) product is able to detect anthropogenic changes to terrestrial carbon storage and the results of several simulation experiments meant to represent potential forest management scenarios. As examples, we consider past and future changes due to conversion in the Tropics to agricultural land use from slash-and-burn, e.g., from Reducing emissions from deforestation and forest degradation in developing countries (REDD+) efforts. This has the potential to inform what practices may be observable with current and future technology, e.g., Europe’s upcoming CO2 monitoring mission (CO2M), and where improvement is needed.

Brad Weir↗

Sensitivity and history match analysis of a carbon dioxide “huff-and-puff” injection test in a horizontal shale gas well in Tennessee

Due to improvements in well development, shale gas production has gained importance recently, especially in the United States. To improve gas production and develop a better understanding of shale reservoirs, researchers are conducting field tests to monitor CO 2 storage and enhanced gas recovery. Reservoir simulations can then utilize these field results for sensitivity studies, uncertainty analysis, history matching, gas production forecasts, and CO 2 storage capacity estimations. One such field test was performed for the Chattanooga Shale formation in Morgan County, Tennessee. Approximately 463 tonnes (510 tons) of CO 2 was successfully injected into a hydraulically fractured horizontal well over a thirteen-day period in March 2014. The injection test was achieved in four steps: pre-injection, injection, soaking, and flowback. In this paper, those steps were modeled with a reservoir simulator to match the historic production and injection rates with gas component compositions and forecast the production for five years. The reservoir fluid was modeled as a multi-component gas, including CH 4 , C 2 H 6 , C 3 H 8 , N 2 , and CO 2 . Langmuir constants, reservoir pressure, and fracture network volume were adjusted to match simulation results with observed production rates and gas composition. Results showed that, under the same reservoir conditions, each gas component behaves differently by way of compositional changes in production. CH4 behaves like N2, while CO 2 behaves like heavier hydrocarbons such as C 2 H 6 and C 3 H 8 . CO 2 plume results showed that, after injection, the produced CO 2 is mostly derived from fractured limestone (i.e., Fort Payne Formation) because the injected CO 2 is not adsorbed in limestone but rather by shale formations.

03 NATURAL GAS↗

Computational quantum chemistry of metal–organic frameworks

Metal–organic frameworks (MOFs) have premium exceptional properties for a variety of functions, such as gas separation and storage and catalysis. The large variety of possible inorganometallic nodes and organic linkers provide an almost unlimited number of combinations for assembling MOFs, which makes the experimental characterization and examination of all potentially useful combinations practically impossible. Furthermore, experimental studies of MOFs typically fall short in uncovering crucial details regarding their mechanisms of action or the molecular details responsible for their functional properties, such as the nature of adsorbate binding or the structures of transition states. Computational modeling has, therefore, become an efficient and important tool for strategizing the functionalization of MOFs and explicating the mechanisms of their functions. Furthermore, we review the computational methodologies used for computational studies of MOFs, especially Kohn–Sham density functional theory and combined quantum mechanical and molecular mechanical methods for calculating their structural, electronic, and magnetic properties, as well as for understanding the mechanisms of MOFs' applications to magetic devices, thermal conduction, gas adsorption, separation, storage, and sensing, thermal catalysis, photocatalysis, and electrocatalysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Computational Identification and Experimental Demonstration of High‐Performance Methane Sorbents

Abstract Remarkable methane uptake is demonstrated experimentally in three metal‐organic frameworks (MOFs) identified by computational screening: UTSA‐76, UMCM‐152 and DUT‐23‐Cu. These MOFs outperform the benchmark sorbent, HKUST‐1, both volumetrically and gravimetrically, under a pressure swing of 80 to 5 bar at 298 K. Although high uptake at elevated pressure is critical for achieving this performance, a low density of high‐affinity sites (coordinatively unsaturated metal centers) also contributes to a more complete release of stored gas at low pressure. The identification of these MOFs facilitates the efficient storage of natural gas via adsorption and provides further evidence of the utility of computational screening in identifying overlooked sorbents.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Monitoring of helium gas leakage from canister storing spent nuclear fuel: Radiological consequences and management

Chloride-induced stress corrosion cracking (CISCC) of canisters has been identified as a potential degradation mechanism requiring ageing management — especially in a marine air environment. Methods for monitoring helium gas leakage from canisters have been developed on the basis of a phenomenon that the bottom temperature of the canister increases as the top temperature of the canister decreases when helium gas leaks during storage. In this paper, we consider the radiological consequences of CISCC based on two scenarios of helium gas leakage and propose effective management that includes a timeline for monitoring and mitigation. Monitoring helium gas leakage by measuring the difference in temperature between canister surfaces in the dry cask storage of spent fuel (SF) can detect leakage before SF undergoes oxidation as a result of air ingress and before country-specific regulatory limits of off-site doses are exceeded, thereby enabling mitigatory action.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hydrogen adsorption and transport in clay-rich geomaterials: Implications for large-volume underground hydrogen storage

Depleted oil and gas reservoirs, characterized by impermeable clay-rich caprocks, are promising sites for large-scale underground hydrogen storage (UHS), which is a key strategy to support hydrogen-based energy systems. However, experimental data on hydrogen storage in clay-rich geomaterials remain scarce. In this work, we experimentally investigated hydrogen adsorption and migration in clay-rich geomaterials in the presence of nitrogen and water under controlled temperatures. Experimental observations showed that hydrogen was adsorbed in dry illite. A dual-porosity transport model was developed to interpret hydrogen transport between large-pore and small-pore domains in illite. The large-pore domain is the space between clay particles (i.e., inter-particle space), whereas the small-pore domain is the nanoscale pore space between clay mineral layers (i.e., inter-layer or intra-particle space). In contrast, nitrogen showed no evidence of adsorption in dry illite because it cannot move into the small-pore domain due to the relatively large kinetic diameter, referred to as the molecular sieving effect. Here, we found that 0.7–1.3 nm is the length scale regulating this molecular sieving effect, matching the interlayer spacing in illite, suggesting that nitrogen is a promising cushion gas in UHS, which aims to maintain adequate pressure in the reservoir for economic operations. In wetted illite, hydrogen was not adsorbed into the interlayer space due to the occupation of adsorption sites by interlayer water, which highlights the critical role of the clay hydration state in controlling hydrogen-clay interactions. Additionally, hydrogen adsorption experiments on crushed shale indicated that the shale surface possessed adsorption sites more favorable for hydrogen than for nitrogen. Through these experiments, we provide new insights into hydrogen storage mechanisms in clay-rich geomaterials and offer valuable laboratory data for evaluating the performance of large-scale UHS systems.

Adsorption↗

Computational Identification and Experimental Demonstration of High‐Performance Methane Sorbents

Abstract Remarkable methane uptake is demonstrated experimentally in three metal‐organic frameworks (MOFs) identified by computational screening: UTSA‐76, UMCM‐152 and DUT‐23‐Cu. These MOFs outperform the benchmark sorbent, HKUST‐1, both volumetrically and gravimetrically, under a pressure swing of 80 to 5 bar at 298 K. Although high uptake at elevated pressure is critical for achieving this performance, a low density of high‐affinity sites (coordinatively unsaturated metal centers) also contributes to a more complete release of stored gas at low pressure. The identification of these MOFs facilitates the efficient storage of natural gas via adsorption and provides further evidence of the utility of computational screening in identifying overlooked sorbents.

Nath, Karabi↗