Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “gamma detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

A flow-through gamma detection system for sub-surface radioxenon tracer measurements in LYNM PE1

A continuous flow-through, real-time radioxenon sensor array has been designed to monitor either 127 Xe or 133 Xe tracer gas as part of a series of underground chemical explosions in the Low-Yield Nuclear Monitoring (LYNM) Physics Experiment 1 (PE1). The sensors are pairs of shielded thallium-doped sodium iodide gamma-ray detectors that surround a gas measurement chamber. Each measurement chamber is connected to a sampling location in the geology surrounding the chemical explosion or in the access tunnel. The first experiment in the series, PE1 A, occurred in 2023 and the system quantified the 127 Xe tracer gas in the gas sampling lines for four weeks following the experiment execution. The array generated a set of radioxenon concentration time series with a 15-minute resolution that will be used to refine subsurface gas transport models.

Gamma-ray coincidence detection↗

Rapid neutron and gamma-ray source localization using machine learning

Rapid localization of radiation sources is critical for applications including nuclear emergency response, safeguards, and security. However, conventional imaging systems such as neutron scatter cameras and Compton cameras depend on rare coincidence events, which often result in long acquisition times. In this work, we address the challenge of rapid source localization by developing a machine learning approach to predict the direction of a single radiation source using only count rates from an array of neutron and gamma-ray detectors. The proposed model is a fully connected neural network (FCNN) trained using Monte Carlo simulation data from a 252 Cf source. The model hyperparameters are optimized with a small set of routine 252 Cf measurements. We benchmarked the performance of the trained and optimized machine learning model using additional 252 Cf , 137 Cs , and PuBe measurements under laboratory conditions with varying source-detector configurations. For these measurements, the machine learning model achieved a mean localization error smaller than 30° with 3 x 10 3 system counts, corresponding to 8 s measurement time for the imaging system used in this work. In this low-statistics regime, the method outperformed traditional scatter-based imaging by more than 75% in localization accuracy for the evaluated measurement configurations. These results demonstrate that a machine learning-based approach can significantly reduce the time required for accurate single-source localization, providing a robust and computationally efficient alternative to traditional imaging systems in time-critical nuclear security and emergency response scenarios.

Gamma-ray imaging↗

The acrylic vessel for JSNS 2 -II neutrino target

The JSNS 2 (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) is an experiment designed for the search for sterile neutrinos. The experiment is currently at the stage of the second phase named JSNS 2 -II with two detectors at near and far locations from the neutrino source. One of the key components of the experiment is an acrylic vessel, that is used for the target volume for the detection of the anti-neutrinos. Here, the specifications, design, and measured properties of the acrylic vessel are described.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

PMT calibration for the JSNS^2-II far detector with an embedded LED system

The JSNS^2-II (the second phase of JSNS^2, J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) is an experiment aimed at searching for sterile neutrinos. Here, this experiment has entered its second phase, employing two liquid scintillator detectors located at near and far positions from the neutrino source. Recently, the far detector of the experiment has been completed and is currently in the calibration phase. The following properties of all functioning Photo-Multiplier-Tubes (PMTs) to detect the neutrino events in the far detector have been calibrated: PMT gain, its dependence of supplied High Voltage (HV), Peak-to-Valley (PV), and signal timing. This paper presents a detailed description of the calibration process utilizing the LED system. The LED system of the far detector uses two Ultra-Violet (UV) LEDs, which are effective in calibrating all of the PMTs at once. The UV light is converted into the visible light wavelengths inside liquid scintillator via the wavelength shifters, providing pseudo-isotropic light. To achieve a good energy resolution for physics events, a relative gain adjustment of up to 10% is required for all functioning PMTs. This will be achieved using the HV curves measured and the results of the LED calibration. The Peak-to-Valley (PV) ratio values, which distinguish the single photo-electron signal from the pedestal, are similar to those from the production company. Additionally, the precision of the PMT signal timing is measured to be 2.1 ns. This meets the event reconstruction requirement of 10 ns.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Scintillator ageing of the T2K near detectors from 2010 to 2021

The T2K experiment widely uses plastic scintillator as a target for neutrino interactions and an active medium for the measurement of charged particles produced in neutrino interactions at its near detector complex. Over 10 years of operation the measured light yield recorded by the scintillator based subsystems has been observed to degrade by 0.9–2.2% per year. Extrapolation of the degradation rate through to 2040 indicates the recorded light yield should remain above the lower threshold used by the current reconstruction algorithms for all subsystems. This will allow the near detectors to continue contributing to important physics measurements during the T2K-II and Hyper-Kamiokande eras. Additionally, work to disentangle the degradation of the plastic scintillator and wavelength shifting fibres shows that the reduction in light yield can be attributed to the ageing of the plastic scintillator. The long component of the attenuation length of the wavelength shifting fibres was observed to degrade by 1.3–5.4% per year, while the short component of the attenuation length did not show any conclusive degradation.

47 OTHER INSTRUMENTATION↗

A directional gamma-ray telescope using coded aperture techniques

A directional detector for gamma-ray astronomy has been developed to image sources in the energy range 0.1 to 5 MeV. An array of 35 gain stabilized bismuth germanate detectors, together with a coded aperture mask based on a uniformly redundant array allows imaging in 4 deg square sky bins over a 16 x 24 deg field-of-view. The position of a strong point source, such as the Crab Nebula, can be determined to within not more than about 1 deg. A complementary 'anti-mask' greatly reduces systematic effects arising from nonuniform background rates amongst the detectors. The telescope has an effective area of 190 sq cm and an energy resolution of 19.5 percent FWHM at 662 keV. Results of laboratory tests of the imaging system, including the ability to image multiple sources, uniformity of response over the field-of-view, and the effect of the 'anti-mask', are in good agreement with computer simulations. Features of the flight detector system are described and results of laboratory tests and computer simulations are reviewed. A balloon flight of the telescope is planned for the fall of 1982.

Mcconnell, M. L.↗

Analysis of 127 Xe tracer measurements using a net counts method

A suite of measurement systems were deployed as part of the Physical Experiment 1 series of experiments, which involved detonating chemical explosives along with radionuclide tracers in an underground cavity, at the Nevada National Security Site (NNSS) in the United States. One of the radionuclide tracers, 127 Xe was released from the containment following the explosion and detected on a SAUNA Q B sampler situated approximately 3.5 km away. The system uses a beta-gamma coincidence detector system to measure fission product radioisotopes of xenon relevant to nuclear explosion monitoring. In this work we use the coincidence measurement data to analyse and interpret the results from the SAUNA Q B system, to calculate the measured 127 Xe activity concentration(s).

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Effect of natural gamma background radiation on portal monitor radioisotope unmixing

It is well known that national security relies on several layers of protection. One of the most important is the traffic control at borders and ports that exploits Radiation Portal Monitors (RPMs) to detect and deter potential smuggling attempts. Most portal monitors rely on plastic scintillators to detect gamma rays. Despite their poor energy resolution, their cost effectiveness and the possibility of growing them in large sizes make them the gamma-ray detector of choice in RPMs. Unmixing algorithms applied to organic scintillator spectra can be used to reliably identify the bare and unshielded radionuclides that triggered an alarm, even with fewer than 1000 detected counts and in the presence of two or three nuclides at the same time. In this work, we experimentally studied the robustness of a state-of-the-art unmixing algorithm to different radiation background spectra, due to varying atmospheric conditions, in the 16 °C to 28 °C temperature range. In the presence of background, the algorithm is able to identify the nuclides present in unknown radionuclide mixtures of three nuclides, when at least 1000 counts from the sources are detected. With fewer counts available, we found larger differences of approximately 35.9% between estimated nuclide fractions and actual ones. In these low count rate regimes, the uncertainty associated by our algorithm with the identified fractions could be an additional valuable tool to determine whether the identification is reliable or a longer measurement to increase the signal-to-noise ratio is needed. Moreover, the algorithm identification performances are consistent throughout different data sets, with negligible differences in the presence of background types of different intensity and spectral shape.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

AstroPix: A pixelated HVCMOS sensor for space-based gamma-ray measurement

A next-generation medium-energy gamma-ray telescope targeting the MeV range would address open questions in astrophysics regarding how extreme conditions accelerate cosmic-ray particles, produce relativistic jet outflows, and more. One concept, AMEGO-X, relies upon the mission-enabling CMOS Monolithic Active Pixel Sensor silicon chip AstroPix. AstroPix is designed for space-based use, featuring low noise, low power consumption, and high scalability. Desired performance of the device include an energy resolution of 5 keV (or 10% FWHM) at 122 keV and a dynamic range per-pixel of 25–700 keV, enabled by the addition of a high-voltage bias to each pixel which supports a depletion depth of 500 μ m. This work reports on the status of the AstroPix development process with emphasis on the current version under test, version three (v3), and highlights of version two (v2). Version 3 achieves energy resolution of 10.4 ± 3.2% at 59.5 keV and 94 ± 6 μ m depletion in a low-resistivity test silicon substrate.

Astrophysics instrumentation↗

Mapping of inhomogeneous quasi-3D electrostatic field in electro-optic materials

Abstract This paper describes a new method for direct measurement and evaluation of the inhomogeneous electrostatic vector field with translational symmetry in electro-optic materials exhibiting the Pockels effect. It is based on the evaluation of maximum transmittance of low intensity light passing through a sample under a voltage bias. Here, the sample is located between rotating crossed polarizers, and camera images are obtained at each point to determine the electric field. The evaluation procedure is demonstrated using data acquired on a CdZnTeSe quasi-hemispheric semiconductor gamma-ray detector. In addition to CdTe-related compounds, the method can be used for various other materials showing $$\overline{4}3m$$ 4 ¯ 3 m symmetry such as GaAs, CdTe, GaP, 3C-SiC, and ZnS. Furthermore, it can be generalized to other crystalline materials showing the Pockels effect. The method can be used to probe the space charge and the electric field in several kinds of electronic components and devices, as well as provide useful data on the role of defects, contact configurations and other surface and bulk inhomogeneities in the material that can affect the distribution of the internal electric field.

36 MATERIALS SCIENCE↗

Evaluation of crystalline quality of traveling heater method (THM) grown Cd0.9Zn0.1Te0.98Se0.02 crystals

Because of its excellent opto-electronic properties, CdZnTe (CZT) has been the material of choice for x- and gamma-ray detectors operable at room temperature. CZT is the leading commercially available room-temperature radiation detector material today. Although much progress has been made over the past three decades, today's CZT crystals still face certain challenges, especially the presence of the performance-limiting materials defects and the associated relatively high production cost. In this regard, CdxZn1−xTeySe1−y (CZTS) is emerging as a next-generation compound semiconductor, which overcomes some of the limitations of CZT technology for the stated applications. Here, we conducted a study to evaluate the crystalline quality of the traveling heater method grown CZTS with an optimized alloy composition, i.e., Cd0.9Zn0.1Te0.98Se0.02. The as-grown samples were evaluated by low-temperature photoluminescence (PL) spectroscopy and high-resolution x-ray diffraction using the synchrotron light source at Brookhaven National Laboratory. The full width at half maximum of both the PL and x-ray rocking curves was observed to be broadened due to the lattice disorder of the quaternary compound, eventually degrading the crystalline quality. This was consistent with density functional theory calculations.

Roy, U. N. (ORCID:0000000282089680)↗

Upgrades to the gamma ray imager on DIII-D enabling access to high flux hard x-ray measurements during the runaway electron plateau phase (invited)

The Gamma Ray Imager (GRI) is a pinhole camera providing 2D imaging of MeV hard x-ray (HXR) bremsstrahlung emission from runaway electrons (REs) over the poloidal cross section of the DIII-D tokamak. We report a series of upgrades to the GRI expanding the access to RE scenarios from the diagnosis of a trace amount of REs to high flux HXR measurements during the RE plateau phase. We present the implementation of novel gamma ray detectors based on LYSO and YAP crystals coupled to multi-pixel photon counters, enabling a count rate in excess of 1 MHz. Finally, we highlight new insights into the RE physics discovered during the current quench and RE plateau phase experiments as the result of these upgrades.

Lvovskiy, A. (ORCID:0000000236491169)↗

The Vacuum Cherenkov Detector (VCD) for γ-ray measurements in inertial confinement fusion experiments

Inertial confinement fusion experiments at both the National Ignition Facility (NIF) and the Laboratory for Laser Energetics OMEGA laser facility currently utilize Cherenkov detectors, with fused silica as the Cherenkov medium. At the NIF, the Quartz Cherenkov Detectors improve the precision of neutron time-of-flight measurements; and at OMEGA, the Diagnostic for Areal Density provides measurements of capsule shell areal densities. An inherent property of fused silica is the radiator’s relatively low energy threshold for Cherenkov photon production (E threshold < 1 MeV), making it advantageous over gas-based Cherenkov detectors for experiments requiring low-energy γ detection. The Vacuum Cherenkov Detector (VCD) has been specifically designed for efficient detection of low energy γ’s. Its primary use is in implosion experiments, which will study reactions relevant to stellar and big-bang nucleosynthesis, such as T( 4 He,γ) 7 Li, 4 He( 3 He,γ) 7 Be, and 12 C(p,γ) 13 N. Further, the VCD is compatible with LLE’s standard Ten-Inch Manipulator diagnostic insertion module. This work will outline the design and characterization of the VCD as well as provide results from recent experiments conducted at the OMEGA laser facility.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Got plenty of nothing: cosmic voids as a probe of particle dark matter

The search for a particle dark matter signal in terms of radiation produced by dark matter annihilation or decay has to cope with the extreme faintness of the predicted signal and the presence of masking astrophysical backgrounds. It has been shown that using the correlated information between the dark matter distribution in the Universe with the fluctuations of the cosmic radiation fields has the potential to allow setting apart a pure dark matter signal from astrophysical emissions, since spatial fluctuations in the radiation field due to astrophysical sources and dark matter emission have different features. The cross-correlation technique has been proposed and adopted for dark matter studies by looking at dark matter halos (overdensities). Here in this paper we extend the technique by focusing on the information on dark matter distribution offered by cosmic voids, and by looking specifically at the gamma-ray dark matter emission: we show that, while being underdense and therefore producing a reduced emission as compared to halos, nevertheless in voids the relative size of the cross-correlation signal due to decaying dark matter vs. astrophysical sources is significantly more favourable, producing signal-to-background ratios S/B (even significantly) larger than 1 for decay lifetimes up to 2 × 10 30 s. This is at variance with the case of halos, where S/B is typically (even much) smaller than 1. We show that forthcoming galaxy surveys such as Euclid combined with future generation gamma-ray detectors with improved specifications have the ability to provide a hint of such a signal with a predicted significance up to 5.7σ for galaxies and 1.6σ for the cosmic shear. The bound on the dark matter lifetime attainable exploiting voids is predicted to improve on current bounds in a mass range for the WIMP of 25 ÷ 900 GeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Gamma-ray signatures of 𝑟-process radioactivity from the collapse of magnetized white dwarfs

We predict the gamma-ray line emission from 𝑟-process nuclei synthesized in the ejecta of the accretion-induced collapse (AIC) of a magnetized, rapidly rotating white dwarf. Using ejecta from a two-dimensional general-relativistic neutrino-magnetohydrodynamic simulation, further evolved with a radiation-hydrodynamics code coupled to an in situ nuclear reaction network, we construct angle-dependent gamma-ray spectra in the 0.01–10 MeV band via composition-dependent ray tracing through the ejecta. The emission between ∼1 and 10 d is dominated by 132 I (𝑡 1/2 = 2.3 h), continuously replenished by the decay of its parent 132 Te (𝑡 1/2 = 3.2 d), with additional contributions from 131 I, 133 Xe, and 132 Te . At 𝑡 ≳ 20 d, 56 Co (from 56 Ni decay) becomes the primary emitter. The simultaneous presence of 𝑟 process and iron-peak gamma-ray lines is distinctive of AIC ejecta and absent in binary neutron star mergers, where iron-peak nuclei are generally not synthesized. Comparing with the 3⁢𝜎 continuum sensitivities of planned MeV gamma-ray telescopes (COSI, AMEGO-X, e-ASTROGAM, GRAMS, GammaTPC), we find the brightest 𝑟-process lines detectable to ∼10 Mpc by GammaTPC and GRAMS, with the signal approaching their sensitivity threshold at 30 Mpc. As a result, the 𝑟-process spectral features survive time integration over ∼30 d exposures, demonstrating robustness against the long observation times required by gamma-ray detectors.

Nuclear reactions↗

Investigation of secondary γ -ray angular distributions using the N 15 ( p , α 1 γ ) C * 12 reaction

The observation of secondary γ-rays provides an alternative method of measuring cross sections that populate excited final states in nuclear reactions. The angular distributions of these γ-rays also provide information on the underlying reaction mechanism. Despite a large amount of data of this type in the literature, publicly available R-matrix codes do not have the ability to calculate these types of angular distributions. In this report, the mathematical formalism derived in Brune and deBoer is implemented in the R-matrix code AZURE2 and calculations are compared with previous data from the literature for the 15 N( p, α1γ ) 12 C* reaction. In addition, new measurements, made at the University of Notre Dame Nuclear Science Laboratory using the Hybrid Array of Gamma Ray Detectors (HAGRiD), are reported that span an energy range from E p = 0.88 to 4.0 MeV. Excellent agreement between data and the phenomenological fit is obtained up to the limit of the previous fit at E p = 2.0 MeV and the R-matrix fit is extended from E x ≈ 13.5 up to E x ≈ 15.3 MeV, where 15 N+p and 12 C+α reactions are fit simultaneously for the first time. An excellent reproduction of the 15 N( p, α1γ ) 12 C* and 12 C(α, α) 12 C data is achieved, but inconsistencies and difficulty in fitting other data is encountered and discussed.

6 ≤ A ≤ 19↗

Onset of Fogging and Degradation in Polyvinyl Toluene-Based Scintillators

Plastic-based gamma-ray detector materials such as polyvinyl toluene (PVT) occasionally suffer from loss of optical light transmission due to internal defects or “fogging” when exposed to some environmental conditions over time. Fogging results in reduced scintillation light propagated to the photomultiplier tube for collection. Investigations of the physical cause of these defects and their associated environmental conditions are ongoing. The goal of this work was to characterize the signs and effects of fogging over a simulated 22-year lifespan of the PVT in outdoor environments. Here, two potential mitigation methods were also evaluated, and one successfully mitigated the phenomena.

36 MATERIALS SCIENCE↗