Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “fringe”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Micro Fourier Transform Profilometry (μFTP): 3D shape measurement at 10,000 frames per second

We report that fringe projection profilometry is a well-established technique for optical 3D shape measurement. However, in many applications, it is desirable to make 3D measurements at very high speed, especially with fast moving or shape changing objects. In this work, we demonstrate a new 3D dynamic imaging technique, Micro Fourier Transform Profilometry (μFTP), which can realize an acquisition rate up to 10,000 3D frame per second (fps). The high measurement speed is achieved by the number of patterns reduction as well as high-speed fringe projection hardware. In order to capture 3D information in such a short period of time, we focus on the improvement of the phase recovery, phase unwrapping, and error compensation algorithms, allowing to reconstruct an accurate, unambiguous, and distortion-free 3D point cloud with every two projected patterns. We also develop a high-frame-rate fringe projection hardware by pairing a high-speed camera and a DLP projector, enabling binary pattern switching and precisely synchronized image capture at a frame rate up to 20,000 fps. Lastly, based on this system, we demonstrate high-quality textured 3D imaging of 4 transient scenes: vibrating cantilevers, rotating fan blades, flying bullet, and bursting balloon, which were previously difficult or even unable to be captured with conventional approaches.

3D shape measurement↗

Imaging the Localized Plasmon Resonance Modes in Graphene Nanoribbons

Here, we report a nanoinfrared (IR) imaging study of the localized plasmon resonance modes of graphene nanoribbons (GNRs) using a scattering-type scanning near-field optical microscope (s-SNOM). By comparing the imaging data of GNRs that are aligned parallel and perpendicular to the in-plane component of the excitation laser field, we observed symmetric and asymmetric plasmonic interference fringes, respectively. Theoretical analysis indicates that the asymmetric fringes are formed due to the interplay between the localized surface plasmon resonance (SPR) mode excited by the GNRs and the propagative surface plasmon polariton (SPP) mode launched by the s-SNOM tip. And with rigorous simulations, we reproduce the observed fringe patterns and address quantitatively the role of the s-SNOM tip on both the SPR and SPP modes. Moreover, we have seen real-space signatures of both the dipole and higher-order SPR modes by varying the ribbon width.

36 MATERIALS SCIENCE↗

SIM-Lite Mission Spectral Calibration Sensitivities and Refinements

SIM-Lite missions will perform astrometry at microarcsecond accuracy using star light interferometry. For typical baselines that are shorter than 10 meters, this requires to measure optical path difference (OPD) accurate to tens of picometers calling for highly accurate calibration. A major challenge is to calibrate the star spectral dependency in fringe measurements -- the spectral calibration. Previously, we have developed a spectral calibration and estimation scheme achieving picometer level accuracy. In this paper, we present the improvements regarding the application of this scheme from sensitivity studies. Data from the SIM Spectral Calibration Development Unit (SCDU) test facility shows that the fringe OPD is very sensitive to pointings of both beams from the two arms of the interferometer. This sensitivity coupled with a systematic pointing error provides a mechanism to explain the bias changes in 2007. Improving system alignment can effectively reduce this sensitivity and thus errors due to pointing errors. Modeling this sensitivity can lead to further improvement in data processing. We then investigate the sensitivity to a model parameter, the bandwidth used in the fringe model, which presents an interesting trade between systematic and random errors. Finally we show the mitigation of calibration errors due to system drifts by interpolating instrument calibrations. These improvements enable us to use SCDU data to demonstrate that SIM-Lite missions can meet the 1pm noise floor requirement for detecting earth-like exoplanets.

wave front aberration↗

Maximizing Ion Transmission in Differential Mobility Spectrometry

We provide modeling and experimental data describing the dominant ion-loss mechanisms for differential mobility spectrometry (DMS). Ion motion is considered from the inlet region of the mobility analyzer to the DMS exit, and losses resulting from diffusion to electrode surfaces, insufficient effective gap, ion fragmentation, and fringing field effects are considered for a commercial DMS system with 1-mm gap height. It is shown that losses due to diffusion and radial oscillations can be minimized with careful consideration of residence time, electrode spacing, gas flow rate, and waveform frequency. Fragmentation effects can be minimized by limitation of the separation field. When these parameters were optimized, fringing field effects at the DMS inlet contributed the most to signal reduction. We also describe a new DMS cell configuration that improves the gas dynamics at the mobility cell inlet. The new cell provides a gas jet that decreases the residence time for ions within the fringing field region, resulting in at least twofold increase in ion signal as determined by experimental data and simulations. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sparse recovery of undersampled intensity patterns for coherent diffraction imaging at high X-ray energies

Coherent X-ray photons with energies higher than 50 keV offer new possibilities for imaging nanoscale lattice distortions in bulk crystalline materials using Bragg peak phase retrieval methods. However, the compression of reciprocal space at high energies typically results in poorly resolved fringes on an area detector, rendering the diffraction data unsuitable for the three-dimensional reconstruction of compact crystals. To address this problem, we propose a method by which to recover fine fringe detail in the scattered intensity. This recovery is achieved in two steps: multiple undersampled measurements are made by in-plane sub-pixel motion of the area detector, then this data set is passed to a sparsity-based numerical solver that recovers fringe detail suitable for standard Bragg coherent diffraction imaging (BCDI) reconstruction methods of compact single crystals. The key insight of this paper is that sparsity in a BCDI data set can be enforced by recognising that the signal in the detector, though poorly resolved, is band-limited. This requires fewer in-plane detector translations for complete signal recovery, while adhering to information theory limits. Lastly, we use simulated BCDI data sets to demonstrate the approach, outline our sparse recovery strategy, and comment on future opportunities.

36 MATERIALS SCIENCE↗

Investigation of X-Ray Optical Anisotropy of Materials by means of X-Ray Interferometry

A novel approach is proposed in the present work for investigation of X-ray optical anisotropy of materials, that is based on X-ray interferometric method of measurements. Unlike the existing methods, where the specimen to be tested is placed in the path of one of interfering beams, in the proposed approach the specimens under investigation are placed directly in the paths of both the interfering beams, owing to which the impact of other factors on the shift of interference Moire fringes is eliminated. In this way the Moire fringes simultaneously appear during the same exposure both in the absence and presence of specimens with different orientations of optical axes. Due to the fact that the relative displacement of Moire fringes is observed in three different columns of the same beam, it becomes possible to simultaneously observe and immediately identify the presence of X-ray optical anisotropy, as well as to measure the values of refractive indices n{sub o} and n{sub e} for specimens under study. By means of proposed method the X-ray optical anisotropy of cellophane film was registered and values of refractive indices n{sub o} and n{sub e} for cellophane were measured. It was established that cellophane is X-ray optically positive anisotropic medium.

36 MATERIALS SCIENCE↗

Two-dimensional Imaging Velocity Interferometry: Technique and Data Analysis

We describe the data analysis procedures for an emerging interferometric technique for measuring motion across a two-dimensional image at a moment in time, i.e. a snapshot 2d-VISAR. Velocity interferometers (VISAR) measuring target motion to high precision have been an important diagnostic in shockwave physics for many years Until recently, this diagnostic has been limited to measuring motion at points or lines across a target. We introduce an emerging interferometric technique for measuring motion across a two-dimensional image, which could be called a snapshot 2d-VISAR. If a sufficiently fast movie camera technology existed, it could be placed behind a traditional VISAR optical system and record a 2d image vs time. But since that technology is not yet available, we use a CCD detector to record a single 2d image, with the pulsed nature of the illumination providing the time resolution. Consequently, since we are using pulsed illumination having a coherence length shorter than the VISAR interferometer delay ({approx}0.1 ns), we must use the white light velocimetry configuration to produce fringes with significant visibility. In this scheme, two interferometers (illuminating, detecting) having nearly identical delays are used in series, with one before the target and one after. This produces fringes with at most 50% visibility, but otherwise has the same fringe shift per target motion of a traditional VISAR. The 2d-VISAR observes a new world of information about shock behavior not readily accessible by traditional point or 1d-VISARS, simultaneously providing both a velocity map and an 'ordinary' snapshot photograph of the target. The 2d-VISAR has been used to observe nonuniformities in NIF related targets (polycrystalline diamond, Be), and in Si and Al.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Magnetometry of single ferromagnetic nanoparticles using magneto-optical indicator films with spatial amplification

We present a magneto-optical technique to spatially amplify and image fringe fields from single ferromagnetic nanorods. The fringe fields nucleate magnetic domains in a low-coercivity, perpendicularly magnetized indicator film, which are expanded by an applied out-of-plane field from the nanoscale to the microscale for measurement with polar Kerr microscopy. The nucleation location and therefore magnetic orientation of the sample nanorod are detected as spatially dependent field biases in locally measured hysteresis loops of the indicator film. We first discuss our method to fabricate the high-sensitivity indicator film with low energy argon ion irradiation. We then present a map of the amplified signal produced from a single nanorod as measured by the indicator film and compare it with a simultaneously obtained, unamplified fringe field map. The comparison demonstrates the advantage of the amplification mechanism and the capability of the technique to be performed with single-spot magneto-optical Kerr effect magnetometers. Our signal-to-noise ratio determines a minimum measureable particle diameter of tens of nanometers for typical transition metals. We finally use our method to obtain hysteresis loops from multiple nanorods in parallel. Our technique is unperturbed by applied in-plane fields for magnetic manipulation of nanoparticles, is robust against many common noise sources, and is applicable in a variety of test environments. We conclude with a discussion of the future optimization and application of our indicator film technique.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Nanograting formation on metals in air with interfering femtosecond laser pulses

It is demonstrated that a homogeneous nanograting having the groove period much smaller than the laser wavelength (∼800 nm) can be fabricated on metals in air through ablation induced by interfering femtosecond laser pulses (100 fs at a repetition rate of 10 Hz). Morphological changes on stainless steel and Ti surfaces, observed with an increase in superimposed shots of the laser pulses at a low fluence, have shown that the nanograting is developed through bonding structure change at the interference fringes, plasmonic near-field ablation to create parallel grooves on the fringe, and subsequent excitation of surface plasmon polaritons to regulate the groove intervals at 1/3 or 1/4 of the fringe period over the whole irradiated area. Calculation for a model target having a thin oxide layer on the metal substrate reproduces well the observed groove periods and explains the mechanism for the nanograting formation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Point source atom interferometry with a cloud of finite size

We demonstrate a two axis gyroscope by the use of light pulse atom interferometry with an expanding cloud of atoms in the regime where the cloud has expanded by 1.1–5 times its initial size during the interrogation. Rotations are measured by analyzing spatial fringe patterns in the atom population obtained by imaging the final cloud. The fringes arise from a correlation between an atom's initial velocity and its final position. This correlation is naturally created by the expansion of the cloud, but it also depends on the initial atomic distribution. We show that the frequency and contrast of these spatial fringes depend on the details of the initial distribution and develop an analytical model to explain this dependence. We also discuss several challenges that must be overcome to realize a high-performance gyroscope with this technique.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A tunable path-separated electron interferometer with an amplitude-dividing grating beamsplitter

We demonstrate a tunable path-separated electron interferometer using a single amplitude-dividing beamsplitter to prepare multiple spatially isolated, coherent electron probe beams. We place four electrostatic bi-prisms in the optical column of a scanning transmission electron microscope (STEM) to achieve path separations of up to 25 μ m, the largest demonstrated within amplitude-division electron interferometers while maintaining fringe visibility of the directly observed interference fringes at the detector. We characterize the fringe visibility of this setup over a range of path separations and perform STEM holography to reconstruct the full object wave of a fabricated Si ramp test phase object. We report a quantitative object-wave measurement in this configuration and confirm with an independent off-axis electron holography measurement. This experimental design can potentially be applied to high-resolution phase imaging and fundamental physics experiments, such as an exploration of the electron wave packet coherence length and the Aharonov-Bohm effect.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Local variability in the orbit of Saturn's F ring

We present an analysis of the orbit of Saturn's F ring using images recorded by the Imaging Science Subsystem of the Cassini spacecraft. A total of 9805 observations have been made from 10 image sequences obtained between 2006 November 23 and 2009 July 28. Each sequence of up to 240 images spans a single orbit of the F ring, allowing 10 independent high-precision estimates of the ring orbit to be made over this ∼3 year period. The ring has been modeled as an inclined uniformly precessing ellipse. The results show a variability in the orbital elements with, for example, the semi-major axis scattered between 140211.2 ± 0.1 km and 140232.9 ± 0.4 km and the fitted periapses locked to the value obtained from a combined fit using the entire three-year span of observations. We show that the observed scatter between the individual estimates of the ring orbit reflect the differing past histories of the particular segments of ring being fitted and that the values are scattered within the limits expected from a single gravitational encounter with the nearby moon, Prometheus. In the combined fit, the scatter averages out to reveal a small systematic bias with respect to the results of Bosh et al. and Albers et al. We believe this is a consequence of the proximity of Prometheus to the ring in the image sequences chosen for this analysis. Finally, we note a close empirical commensurability between the apsidal precession rate, ϖ-dot , of the F ring and the synodic period between Prometheus and the F ring, such that n {sub Prom} – n {sub Fring} ≈ 2 ϖ-dot {sub Fring}, where n {sub Prom} and n {sub Fring} are the mean motions, and discuss its implications.

79 ASTRONOMY AND ASTROPHYSICS↗

Characterization of light-induced potentials in the strong-field dissociation of O 2 +

In this work, we investigate theoretically the imprints of light-induced potentials (LIPs) on the dissociation dynamics of O 2 + molecular ions, as observable in angle-resolved fragment kinetic-energy-release (KER) spectra. Following the vibrational and rotational dynamics of the initial pump-laser-excited cationic nuclear wave packet, while accounting for the dipole coupling between the O 2 + ( a 4 Π u ) and O 2 + ( f 4 Π g ) electronic states in 800-nm 40-fs probe-laser pulses with peak intensities between 10 13 and 10 14 W / cm 2 , we calculate angle-resolved KER spectra which reveal characteristic energy- and angle-dependent fringe structures. These fringes shift downward in energy as the molecular alignment angle θ relative to the probe-pulse polarization direction increases from 0 to π / 2 . The angle-dependent shifts in the KER fringes increase for larger probe-pulse peak intensities and follow the angle and light-wave-intensity dependence of the vibrational spectrum in the associated Floquet bond-hardening well, which is a manifestation of transient O 2 + nuclear-probability trapping in the LIP during dissociation. By examining the rovibrational dynamics of the dissociating molecular cation near the light-induced conical intersection (LICI) in the cationic LIP surface at θ = π / 2 , we identify related angle-dependent structures in the KER spectra, suggesting a means for assessing the significance of LICIs in molecular dissociation pathways.

74 ATOMIC AND MOLECULAR PHYSICS↗

Ultrahigh-resolution spectroscopy with atomic or molecular dark resonances: Exact steady-state line shapes and asymptotic profiles in the adiabatic pulsed regime

Exact and asymptotic line shape expressions are derived from the semiclassical density matrix representation describing a set of closed three-level {Lambda} atomic or molecular states including decoherences, relaxation rates, and light shifts. An accurate analysis of the exact steady-state dark-resonance profile describing the Autler-Townes doublet, the electromagnetically induced transparency or coherent population trapping resonance, and the Fano-Feshbach line shape leads to the linewidth expression of the two-photon Raman transition and frequency shifts associated to the clock transition. From an adiabatic analysis of the dynamical optical Bloch equations in the weak field limit, a pumping time required to efficiently trap a large number of atoms into a coherent superposition of long-lived states is established. For a highly asymmetrical configuration with different decay channels, a strong two-photon resonance based on a lower states population inversion is established when the driving continuous-wave laser fields are greatly unbalanced. When time separated resonant two-photon pulses are applied in the adiabatic pulsed regime for atomic or molecular clock engineering, where the first pulse is long enough to reach a coherent steady-state preparation and the second pulse is very short to avoid repumping into a new dark state, dark-resonance fringes mixing continuous-wave line shape properties and coherent Ramsey oscillations are created. Those fringes allow interrogation schemes bypassing the power broadening effect. Frequency shifts affecting the central clock fringe computed from asymptotic profiles and related to the Raman decoherence process exhibit nonlinear shapes with the three-level observable used for quantum measurement. We point out that different observables experience different shifts on the lower-state clock transition.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A bi-prism interferometer for hard x-ray photons

Micro-fabricated bi-prisms have been used to create an interference pattern from an incident hard X-ray beam, and the intensity of the pattern probed with fluorescence from a 30 nm-thick metal film. Maximum fringe visibility exceeded 0.9 owing to the nano-sized probe and the choice of single-crystal prism material. A full near-field analysis is necessary to describe the fringe field intensities, and the transverse coherence lengths were extracted at APS beamline 8-ID-I. It is also shown that the maximum number of fringes is dependent only on the complex refractive index of the prism material.

47 OTHER INSTRUMENTATION↗

Novel chemoresistive CH{sub 4} sensor with 10 ppm sensitivity based on multiwalled carbon nanotubes functionalized with SnO{sub 2} nanocrystals

Chemoresistive sensors based on multiwalled carbon nanotubes (MWCNTs) functionalized with SnO{sub 2} nanocrystals (NCs) have great potential for detecting trace gases at low concentrations (single ppm levels) at room temperature, because the SnO{sub 2} nanocrystals act as active sites for the chemisorption of gas molecules, and carbon nanotubes (CNTs) act as an excellent current carrying platform, allowing the adsorption of gas on SnO{sub 2} to modulate the resistance of the CNTs. However, uniform conjugation of SnO{sub 2} NCs with MWCNTs is challenging. An effective atomic layer deposition based approach to functionalize the surface of MWCNTs with SnO{sub 2} NCs, resulting in a novel CH{sub 4} sensor with 10 ppm sensitivity, is presented in this paper. Scanning electron microscopy, transmission electron microscopy (TEM), energy dispersive x-ray spectroscopy, and Raman spectroscopy were implemented to study the morphology, elemental composition, and the crystal quality of SnO{sub 2} functionalized MWCNTs. High resolution TEM images showed that the crystal quality of the functionalizing SnO{sub 2} NCs was of high quality with clear lattice fringes and the dimension almost three times smaller than shown thus far in literature. A lift-off based photolithography technique comprising bilayer photoresists was optimized to fabricate SnO{sub 2} functionalized MWCNTs-based chemoresistor sensor, which at room temperature can reliably sense below 10 ppm of CH{sub 4} in air. Such low level gas sensitivity, with significant reversible relative resistance change, is believed to be the direct result of the successful functionalization of the MWCNT surface by SnO{sub 2} NCs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

PSF and MTF Measurement Methods for Thick CCD Sensor Characterization

Knowledge of the point spread function (PSF) of the sensors to be used in the Large Synoptic Survey Telescope (LSST) camera is essential for optimal extraction of subtle galaxy shape distortions caused by gravitational weak lensing. We have developed a number of techniques for measuring the PSF of candidate CCD sensors to be used in the LSST camera, each with its own strengths and weaknesses. The two main optical PSF measurement techniques that we use are the direct Virtual Knife Edge (VKE) scan as developed by Karcher, et al. and the indirect interference fringe method after Andersen and Sorensen that measures the modulation transfer function (MTF) directly. The PSF is derived from the MTF by Fourier transform. Other non-optical PSF measurement techniques that we employ include {sup 55}Fe x-ray cluster image size measurements and statistical distribution analysis, and cosmic ray muon track size measurements, but are not addressed here. The VKE technique utilizes a diffraction-limited spot produced by a Point-Projection Microscope (PPM) that is scanned across the sensor with sub-pixel resolution. This technique closely simulates the actual operating condition of the sensor in the telescope with the source spot size having an f/number close to the actual telescope design value. The interference fringe method uses a simple equal-optical-path Michelson-type interferometer with a single-mode fiber source that produces interference fringes with 100% contrast over a wide spatial frequency range sufficient to measure the MTF of the sensor directly. The merits of each measurement technique and results from the various measurement techniques on prototype LSST sensors are presented and compared.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Brushed permanent magnet DC MLC motor operation in an external magnetic field

Purpose: Linac-MR systems for real-time image-guided radiotherapy will utilize the multileaf collimators (MLCs) to perform conformal radiotherapy and tumor tracking. The MLCs would be exposed to the external fringe magnetic fields of the linac-MR hybrid systems. Therefore, an experimental investigation of the effect of an external magnetic field on the brushed permanent magnet DC motors used in some MLC systems was performed. Methods: The changes in motor speed and current were measured for varying external magnetic field strengths up to 2000 G generated by an EEV electromagnet. These changes in motor characteristics were measured for three orientations of the motor in the external magnetic field, mimicking changes in motor orientations due to installation and/or collimator rotations. In addition, the functionality of the associated magnetic motor encoder was tested. The tested motors are used with the Varian 120 leaf Millennium MLC (Maxon Motor half leaf and full leaf motors) and the Varian 52 leaf MKII MLC (MicroMo Electronics leaf motor) including a carriage motor (MicroMo Electronics). Results: In most cases, the magnetic encoder of the motors failed prior to any damage to the gearbox or the permanent magnet motor itself. This sets an upper limit of the external magnetic field strength on the motor function. The measured limits of the external magnetic fields were found to vary by the motor type. The leaf motor used with a Varian 52 leaf MKII MLC system tolerated up to 450{+-}10 G. The carriage motor tolerated up to 2000{+-}10 G field. The motors used with the Varian 120 leaf Millennium MLC system were found to tolerate a maximum of 600{+-}10 G. Conclusions: The current Varian MLC system motors can be used for real-time image-guided radiotherapy coupled to a linac-MR system, provided the fringe magnetic fields at their locations are below the determined tolerance levels. With the fringe magnetic fields of linac-MR systems expected to be larger than the tolerance levels determined, some form of magnetic shielding would be required.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗