Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “forensics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Improving robustness for model discerning synthesis process of uranium oxide with unsupervised domain adaptation

The quantitative characterization of surface structures captured in scanning electron microscopy (SEM) images has proven to be effective for discerning provenance of an unknown nuclear material. Recently, many works have taken advantage of the powerful performance of convolutional neural networks (CNNs) to provide faster and more consistent characterization of surface structures. However, one inherent limitation of CNNs is their degradation in performance when encountering discrepancy between training and test datasets, which limits their use widely. The common discrepancy in an SEM image dataset occurs at low-level image information due to user-bias in selecting acquisition parameters and microscopes from different manufacturers. Therefore, in this study, we present a domain adaptation framework to improve robustness of CNNs against the discrepancy in low-level image information. Furthermore, our proposed approach makes use of only unlabeled test samples to adapt a pretrained model, which is more suitable for nuclear forensics application for which obtaining both training and test datasets simultaneously is a challenge due to data sensitivity. Through extensive experiments, we demonstrate that our proposed approach effectively improves the performance of a model by at least 18% when encountering domain discrepancy, and can be deployed in many CNN architectures.

scanning electron microscopy↗

Ambient Mass Spectrometry Rapid Analysis Methods for Trace Inorganics

The ability to rapidly detect and characterize the chemistry of trace quantities of inorganic species has multiple potential applications, including nuclear safeguards, nuclear forensics, and environmental monitoring. Some mass spectrometric methods currently exist, but they are costly and time-intensive, often destroying chemical information in the process of ionization. Ambient mass spectrometry is a relatively new analytical method in which samples are introduced to the mass spectrometer from atmospheric pressure, rather than from high vacuum. Ambient MS can operate with gentler ionization methods such as electrospray ionization (ESI) and paper-spray ionization (PSI), reducing fragmentation and preserving the chemical information of the analyte. This may be useful for determining the intended purpose of material in a sample. Strontium, part of nuclear fallout, is analyzed here to test these new analytical methods for viability. Electrospray ionization mass spectrometry functions by spraying the sample as a solution through a needle charged to a few kV. A nebulizing gas flows out along with the sample to create the spray before droplets enter a drying chamber with heated drying gas to remove the solvent molecules. From there bare analyte ions enter the mass spectrometer. This method has the advantage of relatively fast sample preparation and stable ionization. More stable ionization produces higher-quality data. Paper-spray ionization mass spectrometry operates by applying sample to a paper triangle. The paper triangle is then electrified in a metal clamp to a few kV before spray solvent is applied. The spray solvent transports analyte in the sample to the tip, where it is ionized and enters the mass spectrometer. One advantage of this method is reduced sample preparation - an analyst can even swipe a surface and cut a triangle directly from the swipe. The data analysis serves to rapidly process tens of samples all at once. The mass spectrometer outputs a file containing a few hundred spectra for each sample. The pipeline processes each one to identify peaks of interest. A full palette of data analysis metrics are generated, including plots of the raw data and plots of calculated values such as isotopic ratios. The pipeline filters the raw data to remove noise and background peaks, as well as peaks representing detector saturation. A heat map is generated to show the overall spectrum in mass-time- intensity space. Post-processing, we obtained the desired calibration curves, demonstrating that both ESI-MS and PSI-MS are viable methods for quantifying trace amounts of inorganics while retaining their chemical speciation information. ESI-MS demonstrated a linear response region of 100 ppb to 20 ppm, with a limit-of-detection of around 100 ppb. At top left is an example spectrum with the {sup 88}SrNO{sub 3} peak identified to show the retention of chemical speciation. PSI-MS showed a linear response region of around 1 ppb to 1 ppm, with a limit-of-detection of near 1 ppb. PSI-MS produced more erratic results than ESI-MS, likely due to the variability in ionization resulting from manual positioning of the paper triangle near the MS inlet. Future efforts will focus on improving the repeatability of PSI-MS as well as analyzing other species of interest such as cerium and uranium. Improvements will also be made to create more reliable data extraction and intelligent data filtering.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Direct Alpha Spectrometry of Nuclear Fallout

Advanced instruments and methods are under development to allow direct alpha spectrometry of nuclear fallout debris near the point of collection, to support nuclear forensics (NF). New approaches are needed to support NF in order to accelerate the process for data generation and reduce the overall timeline for decision making. Fallout debris at short time periods following detonation can be difficult to work with for alpha spectrometry, due to the presence of intense beta radiation originating from significant quantities of high-activity fission products. Intense beta radiation can challenge traditional silicon-based high-resolution alpha spectrometers. Addressing this, single-crystal (sc) chemical vapor deposition (CVD) produced diamond semiconductors have been studied for use for alpha spectrometry for assaying nuclear fallout debris. Tests have been performed using scCVD sensors to assay a variety of actinide-bearing samples. Sample preparation, when done, has been limited to pulverization using a mechanical ball mill. To reduce measurement times, multi-chip arrays of scCVD diamond semiconductor have been developed in form factors suitable for field deployment in support of NF objectives. These arrays have been tested using high-beta-activity sol gel surrogate nuclear explosive debris (SNED) containing varying concentrations of uranium and plutonium. Results from the use of scCVD detectors with sol gel SNED will be presented.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Visualizing the Nanoscale Oxygen and Cation Transport Mechanisms during the Early Stages of Oxidation of Fe–Cr–Ni Alloy Using In Situ Atom Probe Tomography

Abstract Understanding the early stages of interactions between oxygen and material surfaces—especially at very high spatial resolutions—is highly beneficial for fields ranging from materials degradation, corrosion, geological sciences, forensics, and catalysis. The ability of in situ atom probe tomography (APT) is demonstrated to track the diffusion of oxygen and metal ions at nanoscale spatial resolution during the early stages of oxidation of a model Fe–Cr–Ni alloy. Using 18 O isotope tracers in these in situ APT experiments and complementary ex situ multimodal microscopy, spectroscopy, and computational simulations allows to precisely analyze the kinetics of oxidation and determine that outward cation diffusion to oxide/air interface is the primary mechanism for intragranular oxide growth in this alloy at 300 °C. This unique in situ isotopic tracer APT approach and the insights gained can be highly beneficial for studying early stages of gas–surface reactions in a broad array of materials.

36 MATERIALS SCIENCE↗

The electronic Raman scattering spectrum of PuO 2

Here the Raman spectrum of PuO 2 was measured up to 13,000 cm –1 with three different laser excitation wavelengths spanning the resonance (405 nm), near-resonance (457 nm), and preresonance (514 nm) energy range. Approximately 26 never-before-seen bands were observed between 3500 and 13,000 cm –1 . Given the very high energy of the Raman shifts of these bands and the relative insensitivity of their spectral position to the interrogating laser wavelength, they are believed to arise from an electronic origin. These bands are present in both freshly calcined and radiolytically aged PuO 2 , although a broad luminescence is observed in the aged material, which obscures many of the high frequency features. In situ laser annealing of the material attenuated this luminescence and allowed for clear observation of these never-before-seen spectral features. Discovery of these high-energy bands presents a new way of identifying PuO 2 for nuclear nonproliferation and forensics purposes.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Isotopic analysis of sub-nanogram neodymium loads using new ATONA™ amplifiers

The long-term gains of the ATONA™ amplifiers are shown to have less than 1 ppm variability. Repeat measurements of the JNdi-1 reference material demonstrate the ability of the ATONA™ amplification technology to make measurements of 143 Nd/ 144 Nd ratios with 23 ppm external reproducibility on 100-pg loads. The effect of increasing integration time on analytical reproducibility is also displayed as increasing integration time from 10 to 30s reduced the external measurement uncertainty from 37 to 23 ppm. These measurements represent an improvement of more than a factor of 3 in external measurement reproducibility relative to previously published 143 Nd/ 144 Nd measurements of 100-pg loads. Furthermore, this new technology will allow for the measurement of smaller samples for precise isotope ratios and open new avenues of research in the geological and nuclear forensic communities.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Complete resolution across the neodymium/samarium isotopic envelope with a liquid sampling‐atmospheric pressure glow discharge — Orbitrap mass spectrometer

Rationale Nd and Sm isotope ratios play an important role in geological dating and as nuclear forensic signatures; however, the overlap of the respective 144, 148, 150 Nd/Sm isobars requires prior separations to be performed before analysis on typical MS platforms. The work presented here overcomes these isobaric interferences using ultrahigh‐mass resolution to alleviate interference without prior chemical separations. Methods A liquid sampling‐atmospheric pressure glow discharge ion source was coupled to a standard, QExactive Focus Orbitrap mass spectrometer, providing a mass resolution of ~80 k. A Spectroswiss FTMS booster X2 data acquisition package was used to collect extended transients, providing much higher mass resolution; ~230 k and ~600 k are employed here for Nd and Sm isotopes. Results While the standard Orbitrap resolution is far greater than typical “atomic” MS platforms, it was insufficient to alleviate all isobars. The use of a resolution of ~230 k resulted in baseline separation across the entire isotopic envelope for both Nd and Sm. Isotope ratios obtained from Nd:Sm mixtures using high‐resolution were equivalent to those found for individual‐element solutions, while isotope ratios obtained at a resolution of ~80 k (standard for the OEM data system) showed large deviations. Conclusions Use of ultrahigh‐resolution is an attractive alternative to extensive chemical separations to alleviate severe isobaric interferences. Sufficient mass resolution greatly reduces/eliminates the need for sample manipulations (separations) before analysis while reducing costs and total analysis times.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Prospects for Surrogate Neutron Capture Measurements with Radioactive Ion Beams and GODDESS

Neutron capture reactions are responsible for the synthesis of almost all of the elements heavier than iron through the slow s-process, that proceeds close to the line of stability, and the rapid r-process, with very neutron-rich waiting points. Uncertainties in (n,γ) rates in neutron rich nuclei, especially near closed neu- tron shells, can have significant impact [1] on the predictions of final abundances for different astrophysical scenarios for the r process. Understanding (n,γ) rates on neutron-rich fission fragments is also important for nuclear forensics and stockpile stewardship science. Ratkiewicz et al. [2 and references therein] has recently demonstrated that the (d,pγ) reaction is a valid surrogate for (n,γ), where the formation of the compound nucleus from the breakup of the deuteron has been calculated in a reaction model and the subsequent measured gamma-decay probabilities are reproduced with standard level density and strength functions in a Bayesian approach. In parallel to the surrogate validation efforts, we have demonstrated that the (d,pγ) reaction can be measured in inverse kinematics with Gammasphere ORRUBA: Dual Detectors for Experimental Structure Studies (GODDESS) [3] where the Gammasphere array of Compton-suppressed HPGe detectors is coupled to the Oak Ridge Rutgers University Barrel Array of position-sensitive silicon strip detectors. During the commissioning campaign we measured the (d,pγ) reaction with 134 Xe and 95 Mo beams, the latter to demonstrate the surrogate method in inverse kinematics. The present talk will present preliminary results from this campaign including γ-decay probabilities and prospects for surrogate (n,γ) measurements with 143 Ba fission-fragment beams.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Column separation of tetravalent cerium fission products from trivalent rare earth radio-isotopes

Rapid and efficient isolation of individual rare earth element (REE) radioisotopes from complex mixtures is necessary to support the fields of nuclear forensics, medical isotope production and nuclear physics measurements. The separations must be robust and generate sufficiently high purity samples for subsequent radiological analysis. Current methodologies utilize a laborious two step Ce(IV)-iodate precipitation followed by Ce(IV)-nitrate di-(2-ethylhexyl)phosphoric acid/n-heptane extraction. This work reports an alternative method to isolate Ce fission product isotopes equilibrated with milligrams of cold carrier, from the remaining REE’s using a Ce(IV)/LN-resin (Eichrom Technologies) based separation. Optimization of Ce(IV) loading, REE(III) elution volume and subsequent Ce(III) stripping step utilized 166m Ho tracer. Mixed fission product experiments provided a further test of this LN-resin method, with analysis of purified 141/144 Ce, 147 Nd and 91 Y. Overall, while decontamination factors were lower for the LN-resin method, (vs. the combined precipitation/extraction) the simplicity of the technique and the satisfactory fission product analysis results point to the efficacy of this method.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Collaborative Study for Certification of Trace Elements in Uranium Ore Concentrate CRMs UCLO-1, UCHI-1, and UPER-1

Trace impurity patterns are important nuclear forensic signatures in uranium ore concentrates (UOCs) and Certified Reference Materials (CRMs) are used to validate the analysis methods employed by end users. Herein, we discuss the certification campaign for three new UOC CRMs from the National Research Council Canada: UCLO-1 (https://doi.org/10.4224/crm.2020.uclo-1), UCHI-1 (https://doi.org/10.4224/crm.2020.uchi-1), and UPER-1 (https://doi.org/10.4224/crm.2020.uper-1). This study involved 15 laboratories from 10 countries, using sector-field and (triple) quadrupole inductively-coupled plasma mass spectrometry to analyze 64 trace element impurities. We discuss the importance of the acids used for sample digestion, difficulties analyzing in a high uranium matrix, and data combination and uncertainty evaluation for this large dataset.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Alpha/beta-gated gamma–gamma spectroscopy of mixed fission products for trace analysis

This experiment demonstrated that some hard-to-detect fission products can be quantified directly from mixed fission product samples using advanced radio-emission spectroscopy techniques. A gamma/gamma coincidence detector was combined with a custom liquid scintillation counter to evaluate the benefits of alpha and beta coincident and anti-coincident analysis of mixed fission product samples. Reduction factors in the minimum detectable activity (MDA) relative to traditional gamma counting were quantified for a set of radionuclides. For isotopes like 91Y, 144Ce, 147Nd, and 153Sm MDA reductions of factors of 1-2 were observed using optimized beta thresholds. Using beta anti-coincidence counting reductions of factors 3-5 were observed for isotopes like 89Sr, 95mNb, 115Cd, and 137Cs and factors of 5-7 for isotopes like 235U using alpha coincidence counting. The selectivity of gamma/gamma coincidence and reduction in backgrounds using beta gating were also demonstrated with 136Cs and 153Sm. The improvements observed in the detection sensitivity of fission products and actinides achieved by combining time-correlated radiation signatures is significant and of value to applications such as nuclear fission physics, environmental monitoring for nuclear waste, reactor accidental releases, and nuclear forensics.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Fission neutron activations of stainless steel and its corresponding elemental components

Characterizing neutron activation of stainless steel is a critical task for many applications, and yet little activation data is available for this alloy. To address the need, a series of neutron activation experiments have been performed using the Flattop critical assembly at the National Criticality Experiments Research Center. Several experimental conditions were probed for complete understanding of the neutron environment, including foil composition and position within the assembly. The experimental results reported here will aid in the production of stainless steel benchmarks for a range of nuclear data applications including those used in nuclear forensics analysis.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Noble gas constraints on spent fuel irradiation histories

Fission gas isotopic compositions are sensitive to a variety of reactor operating parameters that include the neutron flux, neutron fluence at different neutron energies, and operating temperature. Measurements of fission gas isotopic compositions thus have potential to constrain reactor simulations for nuclear forensics and safeguards applications. In this paper, we present Kr and Xe isotope measurements from a suite of samples obtained from locations that span the axial length a fuel pin with a well-characterized irradiation history and compare these data to spatially resolved reactor simulations. Here, we observed positive correlations between fluence sensitive isotopic ratios and burnup and between a flux sensitive ratio and power, although some discrepancies are observed between the measured data and model predictions. These differences may be due to simplifications in the model and/or inaccuracies in the cross sections. A much broader measurement to model comparison is required to better understand the discrepancies.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Comparison of microprecipitation methods for polonium source preparation for alpha spectrometry

Detection of radioactive isotopes of polonium is important for understanding natural processes, management and assessment of radioactive waste, and nuclear forensics applications. Further, the most common methods for preparation of polonium samples for alpha spectrometry are electrodeposition and spontaneous deposition which are time consuming. Here, we compare three approaches utilizing rapid microprecipitation from bismuth phosphate, copper sulfide, or tellurium alongside traditional spontaneous deposition methods. From these experiments, results show that copper sulfide microprecipitation recoveries are similar to spontaneous deposition on silver and less time consuming with an approximate five-fold decrease in preparation time, including in the presence of complex matrices like seawater.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Machine learning for fundamental spectroscopic and thermodynamic data of actinides and lanthanides

Accurately modeling optical spectra with absolute radiometric intensities is vital for nuclear forensics applications that depend on characterizing optical emissions from energetic nuclear phenomena. This requires precise knowledge of the individual atomic transition probabilities, known as Einstein A-coefficients, for each emission line. Obtaining these values theoretically or experimentally is often impractical due to the complex electronic structures and the number of transitions involved in atoms relevant to nuclear applications. In this study, we explore the use of machine learning to predict the Einstein A coefficients for atomic transitions. Seven models were evaluated that ranged from deep learning to decision tree algorithms, and found that gradient boosting performed best, specifically the Extreme Gradient Boosting (XGB) architecture, achieving a precision of 86% across transitions of 36 elements. Furthermore, the model was cross-validated using published transition probabilities reported in the literature and applied to estimate Pu plasma temperatures from a previous experiment conducted at Savannah River National Laboratory.

Atomic spectroscopy↗

Analysis of an irradiated uranium sample for source attribution without chemical separation using microplasma ionization and ultrahigh resolution mass spectrometry

The use of element isotope ratios has great potential in not only determining the reactor type used to produce plutonium (Pu) but also in determining the burnup and the time since irradiation. While a powerful nuclear forensic technique, determining element isotope ratios is complicated by severe isobaric interferences when performed on typical inductively coupled plasma mass spectrometers. Such analyses require extensive chemical separations prior to analysis to alleviate the inter-elemental isobars. Ultrahigh mass resolution spectrometry provides a potential alternative, greatly reducing the complexity of sample preparation and turnaround times for these critical measurements. To demonstrate the power of the approach, a sample of irradiated, depleted uranium was analyzed with the liquid sampling—atmospheric pressure glow discharge ion source coupled to an Orbitrap mass spectrometer. The Orbitrap is augmented with an external data acquisition system, Spectroswiss’s FTMS-Booster X2T, allowing collection of extended ion transients, providing higher mass resolution. In using this approach, the 150 Sm/ 149 Sm and 152 Sm/ 149 Sm isotope ratios were found to be within 20% of predicted values without any chemical separations and without mass bias corrections. In addition, the 240 Pu/ 239 Pu isotope ratio was determined, free from the 238 UH + interferences common to the ICP-MS platforms, while at the same time allowing for the determination of U isotopic signatures. While these demonstrative results are from a single sample, the advantages of the microplasma/ultrahigh mass resolution approach to intra-element isotope ratio determinations are clear.

Fuel burnup↗

Evaluation of dried blood spot sampling for verification of exposure to chemical threat agents

Abstract Purpose Exposure to chemical threat agents (CTAs), including nerve agents, the vesicating agent sulfur mustard, and opioids, remains a significant threat to warfighter and civilian populations. Definitive analytical methods to verify exposure to CTAs require shipping refrigerated or frozen biomedical samples to reference laboratories for analysis. Logistical and financial burdens arise as the transport of biomedical samples is subject to strict restrictions and complex packaging, which, if done incorrectly, can lead to sample deterioration. The use of dried blood spot (DBS) sampling could provide operational improvements for collecting, storing, and shipping important forensic samples. Therefore, this effort focuses on developing DBS techniques with Mitra® 30-µL volumetric absorptive microsampling (VAMS®) devices for use in CTA exposure verification. Methods VAMS® devices were loaded and dried with human whole blood that was exposed to the metabolites pinacolyl methylphosphonic acid (PMPA), ethyl methylphosphonic acid (EMPA), 1,1’sulfonylbis[2-(methylsulfinyl)ethane] (SBMSE), norfentanyl, norcarfentanil, norsufentanil, and norlofentanil. Following extraction from the VAMS® devices, metabolites were detected using liquid chromatography-tandem mass spectrometry (LC–MS/MS). The methods were validated for performance by assessing sensitivity, precision, accuracy, and recovery. Results These methods were sensitive to 1 ng/mL for SBMSE, 0.5 ng/mL for PMPA, EMPA, and norfentanyl; 0.1 ng/mL for norlofentanil, and 0.05 ng/mL for norsufentanil and norcarfentanil. All methods met acceptable precision and accuracy criteria with favorable recovery. Conclusions These results demonstrated the utility of VAMS® in stabilizing human whole blood and show promise as an improved collection method for verification of exposure to various CTAs.

Toxicology↗