Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “flexible operation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Design of Critical Experiments Targeting Epithermal Cross Sections of Tantalum

Sandia National Laboratories (SNL) and Oak Ridge National Laboratory (ORNL) are collaborating to develop a capability to test the epithermal/intermediate cross sections of tantalum (Ta) at the SNL critical experiments facility using the Seven Percent Critical Experiment (7uPCX) fuel. The Sandia Critical Experiments (SCX) Program provides a specialized facility for performing water moderated and reflected critical experiments with UO 2 fuel rod arrays. A history of safe reactor operations and flexibility in reactor core configuration has resulted in the completion of several benchmark critical experiment evaluations that are published in the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook. The critical experiments described here are scheduled to be performed at SCX in fiscal year 2023. Currently, fabrication details for the needed new equipment are being finalized for completion of the procurement process. The experiments will then be executed and documented for publication consideration by the ICSBEP.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Hydrogen Plant Hazards and Risk Analysis Supporting Hydrogen Plant Siting near Nuclear Power Plants. Final report

Nuclear power plants (NPPs) are considering flexible plant operations to take advantage of excess thermal and electrical energy. One option for NPPs is to pursue hydrogen production through high temperature electrolysis as an alternate revenue stream to remain economically viable. The intent of this study is to investigate the risk of a high temperature steam electrolysis hydrogen production facility (HTEF) in close proximity to an NPP. This analysis evaluates a postulated HTEF located 1 km from an NPP, including the likelihood of an accident and the associated consequence to critical NPP targets. This analysis shows that although the likelihood of a leak in an HTEF is not negligible, the consequence to critical NPP targets is not expected to lead to a failure at a distance of 1 km. Furthermore, the minimum separation distance of the HTEF is calculated based on the target fragility criteria of 1 psi defined in Regulatory Guide 1.91.

08 HYDROGEN↗

Hydrogen Plant Hazards and Risk Analysis Supporting Hydrogen Plant Siting near Nuclear Power Plants (Final Report)

Nuclear power plants (NPPs) are considering flexible plant operations to take advantage of excess thermal and electrical energy. One option for NPPs is to pursue hydrogen production through high temperature electrolysis as an alternate revenue stream to remain economically viable. The intent of this study is to investigate the risk of a high temperature steam electrolysis hydrogen production facility (HTEF) in close proximity to an NPP. This analysis evaluates a postulated HTEF located 1 km from an NPP, including the likelihood of an accident and the associated consequence to critical NPP targets. This analysis shows that although the likelihood of a leak in an HTEF is not negligible, the consequence to critical NPP targets is not expected to lead to a failure at a distance of 1 km. Furthermore, the minimum separation distance of the HTEF is calculated based on the target fragility criteria of 1 psi defined in Regulatory Guide 1.91.

08 HYDROGEN↗

Markets and Economics for Thermal Power Extraction from Nuclear Power Plants Aiding the Decarbonization of Industrial Processes

This report analyzes the domestic industrial heat markets which may be plausible for using heat extracted from existing LWRs, contributing to the decarbonization of industry. It conceptualizes ideas for a future energy park centered around an LWR with various participating synergistic industries with extensive heat and material integrations with the LWR. It also presents comparison calculations for energy storage options and the levelized cost of heat from an LWR versus the levelized cost of heat from a conventional natural gas boiler and shows under what circumstances heat from LWRs is competitive with and beats natural gas.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Expansion of Hazards and Probabilistic Risk Assessments of a Light-Water Reactor Coupled with Electrolysis Hydrogen Production Plants

This report builds upon the body of work sponsored by the Department of Energy (DOE) Light-Water Reactor Sustainability (LWRS) Flexible Power Operation and Generation (FPOG) program that presented generic probabilistic risk assessments (PRAs) for the addition of a heat extraction system (HES) to light-water reactors to support the co-location of a high temperature hydrogen electrolysis facility (HTEF). Probabilistic and deterministic hazards assessments and risk analyses are leveraged throughout this report. Several improvements and new analyses are included in this report. First, higher amounts of detail in the specifications of the generic HTEFs are used to produce scaled results for a 100, 500, and 1000 MW nominal hydrogen production facility. An additional hazard assessment of 1000 kg of hydrogen storage is performed. The facility hazards and footprint are assessed to determine the safe distance required for placement near the nuclear power plant (NPP). Second, specific designs for corresponding HESs for the different levels of support required by the HTEFs are analyzed in the PRA model. Third, a hazards analysis of the specified HTEFs leads not only to effects of the quantified risk assessment for the NPP, but also qualitative hazards assessment for the community. Finally, a seismic analysis and a high winds analysis have each been added to the PRA. The results investigate the applicability of the potential licensing approaches which do not require a full United States (U.S.) Nuclear Regulatory Commission (NRC) licensing review. The PRAs are generic and include listed assumptions. The HTEF design built for this project has further eliminated many conservative assumptions from the prior PRAs in this series. The PRA results indicate that the 10 CFR 50.59 licensing approach is justified due to the minimal increase in initiating event frequencies for all design basis accidents, with none exceeding 7.7%. The PRA results for core damage frequency and large early release frequency support the use of NRC Regulation Guide 1.174 as further risk information that supports a change without a full licensing amendment review. The hazard analyses and PRA confirm the need for engineered blast barriers of storage tanks and the common production header leaving the HTEF. The hazards analyses and PRA also confirm with high confidence that using the assumptions of design in this report that the safety case for licensing an HES addition and an HTEF sited with its unprotected high-pressure stage components 187 meters from the NPP’s transmission towers (the most fragile structure, system, and component) is strong.

08 HYDROGEN↗

Potential Disposition Options for a Salt Fueled Molten Salt Reactor At the INL (A White Paper)

The molten salt reactor (MSR) design concept has been the focus of significant research and development efforts, both in the U.S. and around the world. There are generally two types of MSRs, salt fueled MSRs that have the fuel dissolved within the salt and solid fueled MSRs that only use the molten salt as a coolant. The range of conceptual designs and the flexibility of operations of MSRs results in a wide range of potential waste streams from salt fueled MSRs; all of which require safe and secure storage and eventual disposition. This white paper will 1) survey the range of salt fueled MSR designs, 2) recognize the implications of design, on the resulting waste streams, and 3) identify the definitions and regulations that apply to the safe and secure management, storage, and disposal of these streams. Research in MSR waste streams is young and the focus of intense research that requires more funding and time to become mature enough to fully support design decisions. Once a specific design is selected, a more detailed management and disposition effort must be performed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Topical Analyses Related to Co-located Industrial Facilities at Nuclear Power Plants

This report investigates topics of interest with regard to Nuclear Power Plants (NPPs) utilizing flexible plant operations and generation (FPOG). Previous reports have identified the risk associated with co-located hydrogen generation facilities. This report evaluates special topics with regard to co-location of both hydrogen and syngas production facilities. A literature review was conducted to evaluate overpressure mitigation techniques that may be available to the NPP to reduce the consequence of an overpressure event. Also, the overpressure consequence of a catastrophic hydrogen storage tank failure event was analyzed. A comparison of the similarities and differences between the methodology utilized in HyRAM+ and Regulatory Guide 1.91 (R.G. 1.91) was performed for overpressure analysis. Also, the trinitrotoluene (TNT) equivalency methodology was utilized to evaluate an overpressure event at a Syngas production facility.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Risk Analysis of a Hydrogen Generation Facility near a Nuclear Power Plant

Nuclear power plants (NPPs) are considering flexible plant operations to take advantage of excess thermal and electrical energy. One option for NPPs is to pursue hydrogen production through high temperature electrolysis as an alternate revenue stream to remain economically viable. The intent of this study is to investigate the risk of a hydrogen production facility in close proximity to an NPP. A 100 MW, 500 MW, and 1,000 MW facility are evaluated herein. Previous analyses have evaluated preliminary designs of a hydrogen production facility in a conservative manner to determine if it is feasible to co-locate the facility within 1 km of an NPP. This analysis specifically evaluates the risk components of different hydrogen production facility designs, including the likelihood of a leak within the system and the associated consequence to critical NPP targets. This analysis shows that although the likelihood of a leak in an HTEF is not negligible, the consequence to critical NPP targets is not expected to lead to a failure given adequate distance from the plant.

08 HYDROGEN↗

Risk Analysis of a 100 MW Hydrogen Generation Facility near a Nuclear Power Plant

Nuclear power plants (NPPs) are considering flexible plant operations to take advantage of excess thermal and electrical energy. One option for NPPs is to pursue hydrogen production through high temperature electrolysis as an alternate revenue stream to remain economically viable. The intent of this study is to investigate the risk of a 100 MW hydrogen production facility in close proximity to an NPP. Previous analyses have evaluated preliminary designs of a hydrogen production facility in a conservative manner to determine if it is feasible to co-locate the facility within 1 km of an NPP. This analysis specifically evaluates the risk components of a 100 MW hydrogen production facility design, including the likelihood of a leak within the system and the associated consequence to critical NPP targets. This analysis shows that although the likelihood of a leak in an HTEF is not negligible, the consequence to critical NPP targets is not expected to lead to a failure given adequate distance from the plant.

08 HYDROGEN↗

Hazards and Probabilistic Risk Assessments of a Light-Water Reactor Coupled with Industrial Facilities

This report provides a roadmap and toolkit for site-specific risk assessments across a broad range of industrial customers co-located with nuclear power plants (NPPs). This report builds upon the body of work sponsored by the Department of Energy (DOE) Light-Water Reactor Sustainability (LWRS) Flexible Plant Operation and Generation Pathway that presented hazards assessment and generic probabilistic risk assessments (PRAs) for the addition of a heat extraction system (HES) to light-water reactors co-located with hydrogen production facilities. The report expands the hazards assessments to include other industrial facilities: an oil refinery, a methanol plant, a synthetic fuel (synfuel) plant, the production of synthetic gas (syngas) as part of the methanol and synfuel plants, and wood pulp and paper mills. All these facilities are specified through industrial process and requirements research performed by national laboratories, universities, and interaction with industry. Many of the processes used in this report are pre-conceptual designs to use for decarbonization of the current technology facilities. A process of failure modes and effects analysis (what can go wrong) and accidentology (what has historically gone wrong) was used to determine the hazards presented to the NPP by the addition of the HES and the industrial customer. Chemical properties of feedstocks and products are summarized as part of the hazards assessment. Example analysis procedures are provided for each of the hazard types identified. These deterministic analyses can be used to assess adherence to licensing criteria. They can also be used to meet other safety goals like protection of the public, workers, or industrial facility equipment. The probabilistic analysis consisted of three sizes of HESs modeled in a PRA to assess the impact on the initiating events (IE) and results of the PRA. The PRA results conclude that the resulting increases in IE frequencies are below the limits required for small changes to existing NPPs under 10 CFR 50.59.

08 HYDROGEN↗

Robust Heat-Flux Sensors for Coal-Fired Boiler Extreme Environments

In this project, robust heat-flux measurement systems were developed. The heat-flux sensors utilize thermoelectric effects to directly transduce the heat-flux inputs to analog electrical voltage signals. They were constructed from dedicated materials that can withstand temperatures of at least 1000°C and maintain adequate performance at these conditions for prolonged periods of time. The proposed approaches took into account numerous considerations, including system cost, sensor head resilience, sensor footprint, data accuracy, response time, and maintenance requirements. Through modern thermoelectric materials design, methodical materials selection and rigorous testing in materials characterization labs and medium-scale fire research facilities, we have demonstrated functioning laboratory prototypes, upon which one could base industrial heat-flux sensing platforms capable of operating in the challenging high-temperature, corrosive environments of the boilers of coal-fired power plants. A distributed sensor array for heat-flux measurements throughout the furnace water-wall, the superheater area and the economizer coils can provide critical data for the power plant control systems to increase efficiency, improve safety and reduce down times. For example, the combined heat-flux sensor/control systems can contribute to the optimization of burner and boiler operations under flexible loads, the optimization of heat-exchange conditions and overall reduction of heat rate and emissions, the prediction of imminent overheating conditions, and the optimization of the soot-blowing protocols.

20 FOSSIL-FUELED POWER PLANTS↗

New Enzymes for Plastics Recycling from Biosensor-Guided Evolution and Machine Learning: Cooperative Research and Development Final Report, CRADA Number CRD-23-24335

The Agile BioFoundry (ABF) is a consortium of national laboratories dedicated to accelerating biomanufacturing and enabling the bioeconomy. The ABF operates a flexible biotechnology platform that can adjust to the needs of numerous government, academic, and industrial partners, thus enabling them to rapidly develop and optimize the production of a wide range of bioproducts. In this project, the ABF partnered with Birch Biosciences, Inc. to use ABF technology to assist in the development of high-performance enzymes that enable circular, sustainable recycling of poly(ethylene terephthalate) (PET) plastics. A primary goal of this project is to enable cost-effective, high yield, sustainable recycling of PET plastic packaging products.

09 BIOMASS FUELS↗

Summary of INL Integrated Energy Systems Research for the Global National Laboratories Consortium on IES

The DOE Office of Nuclear Energy (DOE-NE) program on Integrated Energy Systems (IES) is led by researchers at Idaho National Laboratory (INL), and work is conducted in partnership with an array of other DOE laboratories, industry, and academia. IES research and development activities are additionally complimented by the DOE-NE Light Water Reactor Sustainability (LWRS) program, where work under the Flexible Plant Operations & Generation pathway supports analysis of opportunities for non-electric applications of current fleet nuclear plants and collaborates with multiple plants on near-term hydrogen production demonstration opportunities. The DOE-NE programs additionally partner with the Hydrogen and Fuel Cell Technologies Office under the DOE Office of Energy Efficiency and Renewable Energy to jointly fund the development of analysis tools, technologies, and nuclear-integrated hydrogen demonstration projects. This document provides a brief, high-level summary of IES work as contribution to the annual report for the Global National Laboratories Consortium on IES.

08 HYDROGEN↗

Energy Arbitrage with Hydrogen: HTSE + Combustion Turbine

The Light Water Reactor Sustainability (LWRS) program seeks to keep Nuclear Power Plants (NPPs) competitive in the changing energy market. The Flexible Plant Operation and Generation (FPOG) pathway investigates Energy Storage Systems (ESS) to give operators an alternative to curtailment or paying to put power on the grid. This work investigates the concept of diverting heat and electricity to High Temperature Steam Electrolysis (HTSE) to produce hydrogen when grid demand is low, storing that hydrogen, then burning it in a combustion turbine to produce zero-emission electricity when grid demand is high. A process model of the combustion turbine was developed in Aspen HYSYS, which was used to complete a parametric analysis and techno-economic analysis.

08 HYDROGEN↗

A Comparison of As-loaded Dose Calculations to Measured Dose Rates

Demonstrating that the radiation dose fields surrounding spent nuclear fuel (SNF) storage and transportation systems meet the applicable limits set forth in 10 CFR 72 for storage and 10 CFR 71 for transportation is essential for the safe handling of radioactive material. The Used Nuclear Fuel-Storage, Transportation, and Disposal Analysis Resource and Data System (UNF-ST&DARDS) [2] is used to provide realistic estimates of SNF-related safety margins. The UNF-ST&DARDS dose rate analysis approach differs from that used in typical licensing approaches, which use design-basis assemblies with bounding source term characteristics to demonstrate the packaging design complies with the regulations. These bounding licensing approaches can increase the time needed to qualify fuel for loading into dry storage and the time a loaded system must wait prior to transportation. UNF-ST&DARDS dose rate assessments allow quantification of realistic, uncredited safety margins associated with actual fuel loading compared with the regulatory limits. While realistic estimation of the dose field surrounding SNF systems may allow for additional flexibility in operations, it is essential to understand how these predictions compare to measured doses. The U.S. Department of Energy Office of Integrated Waste Management and the Prairie Island Indian Community conducted a transportation dose assessment to estimate the site-specific incident-free radiation doses from shipping SNF by rail from the Prairie Island Nuclear Generating Plant (PINGP) through the Prairie Island Indian Community Reservation and Trust Land [5,6]. For that effort, the dose rates were obtained for 50 TN-40 and TN-40HT systems in storage configurations. This work compares the predicted dose rates from UNF-ST&DARDS as-loaded calculations with dose rates measured from 50 SNF storage systems at PINGP. The remainder of this paper discusses the data obtained for the evaluation, the modeling methods, and the results of the calculations.

spent nuclear fuel (SNF), UNF-ST&DARDS, Validation↗

Critical Experiments Targeting the Epithermal/Intermediate Cross Sections of Tantalum

Sandia National Laboratories (SNL) and Oak Ridge National Laboratory (ORNL) have collaborated to develop a capability to test the epithermal/intermediate cross sections of materials at the SNL critical experiments facility using the Seven Percent Critical Experiment (7uPCX) fuel. The Sandia Critical Experiments Program provides a specialized facility for performing water moderated and reflected critical experiments with UO 2 fuel rod arrays. The facility offers the ability to modify the core configuration and reactor tank to evaluate various reactor cores for pitch, moderator characteristics, and other criteria. A history of safe operations and flexibility in reactor core configuration has resulted in the completion of nine sets of critical benchmark experiments that have been documented in the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook. The experiment described here is expected to be evaluated for inclusion in the 2024 edition of the ICSBEP Handbook.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Universal Passive Synchronization Method for Grid-Forming Inverters Without Mode Transition

Power systems are transforming with increasing levels of inverter-based resources (IBRs). This transformation requires critical roles of grid-forming (GFM) inverters replacing synchronous generators for bulk power system stabilization and ancillary services, also allowing flexible power system operation, such as microgrid that is operated by multiple GFM IBRs to achieve system resilience against contingencies. To realize the resilient power systems allowing flexible in-and-out operation of GFM IBRs potentially programmed with different primary controls, a synchronization method universally applicable, i.e., independent of control types, would be beneficial to ease the integration process, but it has not been actively studied. To fill the gap, this paper proposes a universal synchronization method that achieves a passive synchronization to enable a smooth transition in a grid with off-nominal system parameters, i.e., voltage and frequency. The logic proposed requires no modification on the primary control, thus applicable to any type of GFMs with a voltage reference input. To validate the concept, a simulation of an IEEE 13-bus benchmark system modified with 3 GFM inverters is presented. It simulates an inverter-driven black start scenario in which GFM inverters autonomously turn on and connect to the grid under heavy loading, using the synchronization logic. The case study demonstrates that GFM inverters can tune their voltage reference to smoothly synchronize without severe transients, and contribute to a seamless black start of the grid under unbalanced load conditions. Two GFM methods - Droop and dispatchable virtual oscillator control - are used for the demo to validate feasibility and interoperability of the passive synchronization.

black start↗

Solar PV Curtailment in Changing Grid and Technological Contexts: Preprint

Solar photovoltaic (PV) systems generate electricity with no marginal costs or emissions. As a result, PV output is almost always prioritized over other fuel sources and delivered to the electric grid. At increasing levels of PV penetration situations arise where PV is curtailed, either because of local supply/demand imbalances or to maintain system flexibility. In 2018, we estimate that about 6.5 million MWh of PV output was curtailed in four key countries: Chile, China, Germany, and the United States. We find that PV curtailment peaks in the spring and fall, when PV output is relatively high but electricity demand is relatively low. Similar to the case of wind, some PV curtailment is attributable to limited transmission capacity connecting sparsely populated solar-heavy regions to load centers.Grid policies generally seek to minimize curtailment because it is viewed as an economic and environmental loss. However, we argue that changing grid and technological contexts warrant new thinking on PV curtailment. In the grid context, as grids integrate more PV and other renewable energy generation, seeking an optimal level of accepted curtailment becomes more efficient than preventing it. In the technological context, emerging technologies such as advanced inverters and low-cost battery storage are making PV systems more flexible. With flexible PV, grid operators can use withheld PV output to provide various non-generation grid services. This withheld PV output is a form of curtailment under prevailing definitions of the term. Hence, policies that aim to minimize curtailment may undercut the ability of grid operators to fully use the emerging capabilities of flexible PV systems. We argue that the changing grid and technological contexts require a re-examination of the curtailment paradigm. We argue that PV output that is withheld to provide grid services is fundamentally different from output that goes unused in response to system constraints. As a result, we propose a more exclusive definition of curtailment as unused PV output rather than the more expansive conventional definition as any reduction in system output from its technical potential. The terminological distinction is more than a question of semantics. Facilitating grid services by withholding PV output may increase the potential value of flexible PV systems to the grid. This shift in thinking may allow grid operators and policymakers to think in terms of PV curtailment management rather than minimization. Effective curtailment management may include policies that increase PV system dispatchability, alternative PV compensation schemes that decouple generator revenue from system output, and policies to increase grid flexibility.

Chile↗