Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “fires”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Realistic operation of two residential cordwood-fired outdoor hydronic heater appliances—Part 2: Particle number and size

The use of wood as a fuel for home heating is a concern from an environmental health and safety perspective as biomass combustion appliances emit high concentrations of particulate matter. Wood burning significantly contributes to wintertime particulate matter concentrations in many states in the northern United States. Of particular concern are outdoor wood-fired hydronic heaters. These devices are concerning as they tend to have very large combustion chambers and typical use patterns can result in long periods of low output, which result in an increased particulate matter emission rate relative to high heat output operating conditions. In this study, the performance of two hydronic heaters operating under different combustion conditions, including four different heat output categories approximately corresponding to categories I–IV denoted in Environmental Protection Agency Method 28 Outdoor Wood-fired Hydronic Heaters, and during start-up and reloading events were investigated. Measurements of flue gas particulate number concentration and size for particles with aerodynamic diameters between 0.006 and 10 µm were made using a dilution sampling system. The measured particle number concentration in the flue gas was between 0.71 and 420 million particles per cubic centimeter and was dependent on fuel loading and heat output. For each hydronic heater tested, the highest average particle concentration was found at the beginning of each test during the cold-start condition. Additionally, the majority of the particles had aerodynamic diameters less than 0.100 µm (particles of this size made up between 64% and 97% of all particles) and less than 1% of all particles had aerodynamic diameters greater than 1 µm for all phases. For particles in the accumulation mode, between 0.100 and 1 µm, the mean particle diameter was dependent on fuel loading and heat output.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Pilot testing of CO2 capture from a coal-fired power plant—Part 2: Results from 1-MWe pilot tests

Abstract Using a 1-MWe slipstream pilot plant, solid-sorbent-based post-combustion CO2 capture was tested at a coal-fired power plant. Results from pilot testing were used to develop a preliminary full-scale commercial design. The sorbent selected for pilot-scale evaluation during this project consisted of an ion-exchange resin that incorporated amines covalently bonded to the substrate. A unique temperature-swing-absorption (TSA) process was developed that incorporated a three-stage fluidized-bed adsorber integrated with a single-stage fluidized-bed regenerator. Overall, following start-up and commissioning challenges that are often associated with first-of-a-kind pilots, the pilot plant operated as designed and expected, with a few key exceptions. The two primary exceptions were associated with: (i) handling characteristics of the sorbent, which were sufficiently different at operating temperature than at ambient temperature when design specifications were established with lab-scale testing; and (ii) CO2 adsorption in the transport line between the regenerator and adsorber that preloaded the sorbent with CO2 prior to entering the adsorber. Results from the pilot programme demonstrate that solid-sorbent-based post-combustion capture can be utilized to achieve 90% CO2 capture from coal-fired power plants.

Sjostrom, Sharon↗

Exploring the Performance and Reliability of Screen-Printable Fire-Through Copper Paste on PERC Solar Cells

In this work, we present the performance and reliability of a fire-through copper (Cu) paste which has been screen printed on c-Si solar cell with passivated emitter rear contact (PERC). The Cu paste is fired through silicon nitride (SiN) anti-reflection coating at a peak temperature of 630 degrees C . SEM images of the Cu paste show a Cu core with ~200 nm oxide shell around the particles. This conductive oxide layer acts as a diffusion barrier between Cu and Si and prevents the degradation of cell performance during accelerated aging conditions. An efficiency of 19.250% has been achieved with Voc=654mV,FF= 76.68%, Jsc=38.40 m.A/cm 2 for champion PERC cells. Accelerated testing of the PERC mini-modules in damp heat chamber with 85 degrees C and 85% humidity have demonstrated that the devices are operational even after 1,500 hours. Devices with screen printed Ag contacts on the front side have been studied in parallel to the Cu contacts for comparison.

copper↗

Root traits reveal safety and efficiency differences in grasses and shrubs exposed to different fire regimes

Plant roots are important components of terrestrial ecosystems, but little is known about how root traits differ between plant species or vary across space in natural ecosystems. In this study, we investigated how root traits vary across grasses and woody shrubs in a tallgrass prairie located in Manhattan, KS, USA. Specifically, were interested in understanding how anatomical traits vary across these different plant groups, across different depths in the soil, and also across multiple areas of tallgrass prairie that are burned at different frequencies. We compared traits that allow roots to use soil water efficiently and those that help roots persist through extended periods of drought. We found that woody roots exhibited traits that allow them to use water efficiently in shallow soils but persist through drought in deeper soil. Here, these traits may allow shrubs to transport water from shallow soils to deeper soil after large rain events and resist extended periods without rain when soils become dry, which may allow woody plants to successfully compete for water in less frequently burned, more diverse plant communities. Grasses had traits that allow them to use water efficiently but also tolerate drought in shallow soils, regardless of fire treatment. This unique trait combination likely gives grasses a competitive advantage over other tallgrass prairie plants across different fire regimes. Together, these results show that anatomical root traits can be used to enhance mechanistic understanding of plant functioning in dynamic ecosystems.

54 ENVIRONMENTAL SCIENCES↗

Annual carbon sequestration and loss rates under altered hydrology and fire regimes in southeastern USA pocosin peatlands

Peatlands drained for agriculture or forestry are susceptible to the rapid release of greenhouse gases (GHGs) through enhanced microbial decomposition and increased frequency of deep peat fires. We present evidence that rewetting drained subtropical wooded peatlands (STWPs) along the southeastern USA coast, primarily pocosin bogs, could prevent significant carbon (C) losses. To quantify GHG emissions and storage from drained and rewetted pocosin we used eddy covariance techniques, the first such estimates that have been applied to this major bog type, on a private drained (PD) site supplemented by static chamber measurements at PD and Pocosin Lakes National Wildlife Refuge. Net ecosystem exchange measurements showed that the loss was 21.2 Mg CO2 ha –1 year –1 (1 Mg = 10 6 g) in the drained pocosin. Under a rewetted scenario, where the annual mean water table depth (WTD) decreased from 60 to 30 cm, the C loss was projected to fall to 2 Mg CO 2 ha –1 year –1 , a 94% reduction. If the WTD was 20 cm, the peatlands became a net carbon sink (–3.3 Mg CO2 ha –1 year –1 ). Hence, net C reductions could reach 24.5 Mg CO 2 ha –1 year –1 , and when scaled up to the 4000 ha PD site nearly 100,000 Mg CO 2 year –1 of creditable C could be amassed. We conservatively estimate among the 0.75 million ha of southeastern STWPs, between 450 and 770 km 2 could be rewet, reducing annual GHG emissions by 0.96–1.6 Tg (1 Tg = 10 12 g) of CO 2 , through suppressed microbial decomposition and 1.7–2.8 Tg via fire prevention, respectively. Despite covering <0.01% of US land area, rewetting drained pocosin can potentially provide 2.4% of the annual CO 2 nationwide reduction target of 0.18 Pg (1 Pg = 10 15 g). Finally, suggesting pocosin restoration can contribute disproportionately to the US goal of achieving net-zero emission by 2050.

58 GEOSCIENCES↗

Full Scale 3D Computational Model of the Industrial -Scale Coal Fired Boiler Performance for Temperature Sensor Installation Guidance

Abstract Nearly 30% of the electricity is generated by using coal as the primary fuel in the US. One of the major concerns in coal-fired power plants is the failure of boiler tubes that leads to unscheduled maintenance and has a huge economical and societal impact. High temperature flue gas along with ash pass over the boiler tubes, which over time leads to tube failure. Therefore, developing temperature sensors for harsh environments and install them for temperature sensing and boiler tube lifetime prediction is an urgent need. On the side of sensor development, the location of the sensor installation is important for stable sensing performance and easy calibration. In this study, computational fluid dynamics and heat transfer modeling are adopted to establish a full-scale 3-dimensional model of a coal-fired boiler to investigate the flue gas temperature distribution within the boiler and identify the proper locations for sensor installation. We proposed three criteria to select the temperature sensor installation location: (1) select the boiler tube panel away from the sidewalls, (2) select the boiler tube section closer to the top wall of the boiler; and (3) select the boiler tube on the back of the boiler panel (not directly facing the flue gas flow). In these regions, the flue gas temperature is stable, providing an ideal environment for stable temperature sensing and calibration.

Gupta, Tanuj↗

QUIC-Fire_GUI

O5080 - QUIC-Fire GUI ment to run QUIC-Fire and other applications

Oliveto, Julia [Los Alamos National Laboratory]↗

Solid particulate mass and number from ducted fuel injection in an optically accessible diesel engine in skip-fired operation

Ducted fuel injection (DFI) is a new combustion strategy that has been shown to significantly attenuate soot formation in diesel engines. While previous studies have used optical diagnostics and optical filter smoke number methods to show that DFI reduces in-cylinder soot formation and engine-out soot emissions, respectively, this is the first study to measure solid particle number (PN) emissions in addition to particle mass (PM). Furthermore, this study quantitatively evaluates the use of transient particle instruments for measuring particles from skip-fired operation in an optical single cylinder research engine (SCRE). Engine-out PN was measured using an engine exhaust particle sizer following a catalytic stripper, and PM was measured using a photoacoustic analyzer. The study improves on earlier preliminary emissions studies by clearly showing that DFI reduces overall PM by 76%–79% and PN for particles larger than 23 nm by 77% relative to conventional diesel combustion at a 1200-rpm, 13.3-bar gross indicated mean effective pressure operating condition. The degree of engine-out PM reduction with DFI was similar across both particulate measurement instruments used in the work. Through the use of bimodal distribution fitting, DFI was also shown to reduce the geometric mean diameter of accumulation mode particles by 26%, similar to the effects of increased injection pressure in conventional diesel combustion systems. This work clearly shows the significant solid particulate matter reductions enabled by DFI while also demonstrating that engine-out PN can be accurately measured from an optical SCRE operating in a skip-fired mode. Based on these results, it is believed that DFI has the potential to enable fuel savings when implemented in multi-cylinder engines, both by lowering the required frequency of active diesel particulate filter regeneration, and by reducing the backpressure imposed by exhaust filtration systems.

33 ADVANCED PROPULSION SYSTEMS↗

Yakima River Basin Temporal Study: Sensor and Sample Data from Wenas Creek following the Evans Canyon Fire in Washington, USA

The Evans Canyon Fire occurred in Washington in August 2020 and burned 76,000 acres of the semi-arid shrub-steppe landscape at low to moderate severities. This fire burned across the Wenas Creek watershed, allowing for a sampling design that included a portion of the stream within the burned area and a reference site upstream of the burn. Monthly data was collected at an unburned (W10) and burned (W20) site from November 2020 to August 2022 for in situ hydrological and water chemistry sensor data, handheld sensor water chemistry data, general environmental context photos, and field metadata. This dataset is comprised of one folder with field photos and one main data folder containing (1) sensor and sample field protocols; (2) file-level metadata (flmd); (3) data dictionary (dd); (4) international geo-sample number (IGSN) mapping file; (5) field metadata; (6) readme; (7) methods codes; (8) dissolved organic carbon (DOC; measured as non-purgeable organic carbon; NPOC); (9) total nitrogen (TN); (10) total suspended solids (TSS); (11) sensor data (specific conductance, pH, total dissolved solids, temperature, pressure, dissolved oxygen, and turbidity) averages; and (12) sensor installation methods. All files are .csv, .jpg, .jpeg, or .pdf.

54 ENVIRONMENTAL SCIENCES↗

Vegetation transect surveys from 2022 and 2023 within the Kougarok Fire Complex (KFC) on the Seward Peninsula in Alaska, USA

This dataset contains recorded vegetation classifications from 16 transects within the Kougarok Fire Complex (KFC) area in Alaska. Each transect is 50 meters long, and vertical vegetation profiles were sampled every 50cm, resulting in 101 points recorded for each transect. At each point, a vertical rod was inserted in the ground and any living plant or substrate touching the rod was recorded from top to bottom. For each plant, the plant functional type (PFT) and species name was identified and recorded. The file "flmd.xlsx" provides file level meta data for all other included files. The file (transect_metadata.csv) contains descriptive information about each of the 16 transects (field observation year and date; latitude and longitude GPS measurements of the 0, 25, and 50 meter points; and whether that area burned during the 1971, 1997, 2002, 2015, and/or 2019 fires). The files (PFT_names.csv and species_names.csv) map the short hand labels for the plant function type (PFT) and species used in the transect surveys to their full names. The remaining files are named for each transect, and contain the results of the vegetation survey for each transect. These files contain the plant functional type and the species identified at each point. Points along the transect with more than one species at that point are listed vertically from top to bottom in these files.The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research.The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska.Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Design and Modeling of an 80 bar Oxy-Combustor for Direct Fired Supercritical CO2 Applications

As supercritical CO2 power cycles for fossil energy power generation continue to generate interest, there are significant issues and unanswered questions regarding injector design, flame stabilization, wall heat transfer, CO emissions, combustion dynamics and other combustion phenomenon. For natural gas, direct-fired cycles with carbon capture it is believed that Computational Fluid Dynamics (CFD) modeling will play an essential role in the combustor design process. To accurately model turbulent reacting flows at these unique conditions, experimental data is needed to validate CFD codes and sub-models and is currently lacking at conditions relevant for these cycles. This paper presents the conceptual design and CFD simulations of an experimental 80 bar oxy-combustion facility and test article currently under construction at NETL. The facility is targeted towards the testing of a single injector, direct-fired sCO2 combustor at the 100 kW thermal output level. While these conditions do not reflect the actual Allam cycle operating conditions (300 bar) they are viewed as a stepping stone in the model validation process at supercritical conditions. Reynolds Averaged Navier-Stokes as well as Large Eddy Simulation are used to model the turbulent combustion process and aid in the design of the combustor and injector. Process parameters including oxidizer preheat temperature and combustor flowrate are investigated.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

AmeriFlux FLUXNET-1F US-Rpf Poker Flat Research Range: Succession from fire scar to deciduous forest

This is the AmeriFlux Management Project (AMP) created FLUXNET-1F version of the carbon flux data for the site US-Rpf Poker Flat Research Range: Succession from fire scar to deciduous forest. This is the FLUXNET version of the carbon flux data for the site US-Rpf Poker Flat Research Range: Succession from fire scar to deciduous forest produced by applying the standard ONEFlux (1F) software. Site Description - This tower is located near Davis Center, Poker Flat Research Range. Deciduous trees and shrubs are dominated at the burned black spruce forest.

Ueyama, Masahito↗

Criticality Control Overpack Fire Testing (Phase III)

This report will describe the one test conducted during phase III of the Pipe Overpack Container (POC) test campaign, present preliminary results from these tests, and discuss implications for the Criticality Control Overpack (CCO). The goal of this test was to see if aerosol surrogate material inside the Criticality Control Container (CCC) gets released when the drum lid of the CCO comes off during a thirty-minute long, fully-engulfing, fire test. As expected from POC tests conducted in Phase I and II of this test campaign, the CCO drum lid is ejected about one minute after the drum is exposed to fully-engulfing flames. The remaining pressure inside the drum is high enough to eject the top plywood dunnage a considerable distance from the drum. Subsequently, most of the bottom plywood dunnage supporting the CCC burns off during and after the fire. High pressure buildup inside the CCC and inside two primary containers holding the surrogate powder also results in damage to the filter media of the CCC and the filter-house, thread attachment of the primary canisters. No discernable release of surrogate powder material was detected from the two primary containers when pre- and post-test average mass were compared. However, when the average masses are corrected to account for possible uncertainties in mass measurements, error overlap does not preclude the possibility that some surrogate powder mass may have been lost from these primary canisters. Still, post-test conditions of the secondary canisters enclosing these two primary canisters suggest it is very unlikely this mass loss would have escaped into the CCC.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Investigation of Cycling Coal-Fired Power Plants Using High-Fidelity Models

The project delivers a well-integrated and validated simulation platform for cycling operation analysis in coal-fired power plant. Two critical mechanical components of the boiler island were analyzed through mechanical integrity assessment and economic benefit analysis. The current phase of the project focuses on the development of the integrated simulation infrastructure and prove its feasibility and effectiveness using two typical use cases. This integrated platform can help save a lot of engineering efforts for model development and simulation analysis. Through the real simulation scenarios in this document, it was demonstrated that using this platform, an analysis can be completed in approximately 2 days, while it could cost several weeks before using this platform. Going forward, the platform built in this project can be used for more boiler service applications, and it can be further enhanced with more functions/features to maximize its usage and benefits. 1) Extend component-level analysis with more use cases to cover all the major critical components of boiler island under cycling operations. A library of critical components can be developed and validated for typical pulverized coal-fired subcritical boiler units. 2) Develop predictive maintenance features based on the integrated models (Digital Twins) and engineering analysis procedures. Predictive maintenance enables each asset to be serviced based on forecast on life consumption and cost profile for replacing/welding the critical mechanical parts of the boiler. This minimizes the chance of unscheduled shutdowns and emergency services at much higher costs and prevent the fatal accidents in unit operations. 3) Develop and maintain a standard library for critical component analysis under flexible plant operations, which will include libraries of: process models, MI models for typical pressure parts, and economic models with typical plant operating data and ISO power trade data.

01 COAL, LIGNITE, AND PEAT↗

Advanced Cost-Effective Coal-Fired Rotating Detonation Combustor for High Efficiency Power Generation

Coal-based detonation as a means of heat addition in power generation devices is a revolutionary “out of the box” technology concept, wherein it is theoretically possible to achieve an increase in total pressure across the combustor as opposed to a loss of available energy as is the case in conventional combustion systems. Detonation is a revolutionary technology concept of pressure gain combustion that exploits pressure rise from the combustion process to augment high flow momentum and pressures. Recognizing that pressure gain combustion has become a topic of elevated national interest, high energetic modes (exergy) pressure gain combustion (PGC) systems are required. Pressure gain combustion is a key enabling technology for maintaining technological superiority in the development of advanced power generation systems. Pressure gain combustion is an innovative scheme of turbulent combustion that considerably increases thermodynamic cycle efficiencies (~10-20%). This project extends the State-of-the-Art by providing the first direct experimental and computational data of operability dynamics and performance characterization data and create the first validated Coal-Fired RDC investigations. Coal-based RDC is an innovative revolutionary technology that would result in high efficiency power generation and reduced of harmful emissions. Also, the fundamental and open source nature of the project will benefit a broader scientific and industry audience who will be able to utilize the outcomes of this project for advancing the coal-fired RDC power generation development.

01 COAL, LIGNITE, AND PEAT↗

Complementary Study of Radiative Heat Transfer and Flow Physics from Moderate-scale Hydrocarbon Pool Fire Simulations

As part of the Advanced Simulation and Computing Verification and Validation (ASCVV) program, a 0.3-m diameter hydrocarbon pool fire with multiple fuels was modeled and simulated. In the study described in this report, systematic examination was performed on the radiation model used in a series of coupled Fuego/Nalu simulations. A calibration study was done with a medium-scale methanol pool fire and the effect of calibration traced throughout the radiation model. This analysis provided a more detailed understanding of the effect of radiation model parameters on each other and on other quantities in the simulations. Heptane simulation results were also examined using this approach and possible areas for further improvement of the models were identified. The effect of soot on radiative losses was examined by comparing heptane and methanol results.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Tritium Fires: Simulation and Safety Assessment

This is the Sandia report from a joint NSRD project between Sandia National Labs and Savannah River National Labs. The project involved development of simulation tools and data intended to be useful for tritium operations safety assessment. Tritium is a synthetic isotope of hydrogen that has a limited lifetime, and it is found at many tritium facilities in the form of elemental gas (T 2 ). The most serious risk of reasonable probability in an accident scenario is when the tritium is released and reacts with oxygen to form a water molecule, which is subsequently absorbed into the human body. This tritium oxide is more readily absorbed by the body and therefore represents a limiting factor for safety analysis. The abnormal condition of a fire may result in conversion of the safer T 2 inventory to the more hazardous oxidized form. It is this risk that tends to govern the safety protocols. Tritium fire datasets do not exist, so prescriptive safety guidance is largely conservative and reliant on means other than testing to formulate guidelines. This can have a consequence in terms of expensive and/or unnecessary mitigation design, handling protocols, and operational activities. This issue can be addressed through added studies on the behavior of tritium under representative conditions. Due to the hazards associated with the tests, this is being approached mainly from a modeling and simulation standpoint and surrogate testing. This study largely establishes the capability to generate simulation predictions with sufficiently credible characteristics to be accepted for safety guidelines as a surrogate for actual data through a variety of testing and modeling activities.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Integration of Pumped Heat Energy Storage with Fossil-Fired Power Plant (Final Report)

The project team of Southwest Research Institute ® (SwRI ® ), Malta Inc. (Malta), and Luminant Generation Company LLC (Luminant) completed a feasibility study for the integration of a 100-MW, 10-hour (1000-MWh) Malta Pumped Heat Energy Storage (MPHES) system with multiple full-sized fossil-fired electricity generation units (EGU) in Luminant portfolio. MPHES is a long-duration, molten-salt-energy storage technology that uses turbomachinery and heat exchangers to transfer energy to a thermal storage media when charging, and removes the heat in a similar fashion when discharging. With high round trip efficiency (60-65%) and long lifespan (30+ years), MPHES provides economic benefits to the fossil-asset owners that can be scaled to integrate with assets across their portfolio. This technology uses hardware components, workforce personnel, and skillsets similar to those used by fossil EGUs, allowing for synergy when co-locating the two technologies. Luminant has approximately 39,000 megawatts of generation across 12 states, operating in six of the seven competitive markets in the U.S. and powered by a diverse portfolio of natural gas, nuclear, coal, and solar facilities. The DeCordova plant in Granbury, Texas, a simple cycle natural gas peaker power plant, was used as the fossil-fired asset in this project. The local market in Granbury, Texas has many influences, including several nearby power plants, a Luminant-owned nuclear plant (Comanche Peak), and substantial wind energy, which causes both negative pricing at night and high market volatility. Reducing false starts of the DeCordova plant and better responding to market volatility would be an economic advantage. Luminant is currently integrating battery storage plant on site to begin addressing these challenges. Integrating long-duration storage, like MPHES, would expand this capability beyond one hour of storage and have the potential to greatly reduce the total number of gas turbine starts. The MPHES charging requirement could help offset the overnight operating costs of Comanche Peak, which cannot load follow, and the nearby Luminant-owned Wise County combined cycle plant that cycles too often. Following the assessment of Luminant’s ERCOT-based portfolio for integration compatibility with Malta’s PHES system and the project tasks of conceptual study, technoeconomic analysis, technology gap assessment, and commercialization plan, the project team effort has resulted in several key outcomes: (1) Identification of market trends in a high-wind penetration market outside a major metropolitan area; (2) Creation of a dispatching model for the MPHES system and the pairing of Li-ion battery with a gas turbine in a real time market; (3) Revenue and cost estimations for operating MPHES alongside a gas peaker plant with real dispatching considerations and comparison with variations in the Malta implementation, including doubling the storage capacity and using two discharge drivetrains; (4) Potential carbon emission reductions possible by replacing gas turbine operation with Malta PHES operation; and (5) Summary of literature-based future market predictions for Texas.

20 FOSSIL-FUELED POWER PLANTS↗