Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “field testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Simple Retrofit High-Efficiency Natural Gas Water Heater Field Test

High performance water heaters are typically more time consuming and costly to install in retrofit applications, making high performance water heaters difficult to justify economically. However, recent advancements in high performance water heaters have targeted the retrofit market, simplifying installations and reducing costs. Four high efficiency natural gas water heaters designed specifically for retrofit applications were installed in single-family homes along with detailed monitoring systems to characterize their savings potential, their installed efficiencies, and their ability to meet household demands. The water heaters tested for this project were designed to improve the cost-effectiveness and increase market penetration of high efficiency water heaters in the residential retrofit market. The retrofit high efficiency water heaters achieved their goal of reducing costs, maintaining savings potential and installed efficiency of other high efficiency water heaters, and meeting the necessary capacity in order to improve cost-effectiveness. However, the improvements were not sufficient to achieve simple paybacks of less than ten years for the incremental cost compared to a minimum efficiency heater. Significant changes would be necessary to reduce the simple payback to six years or less. Annual energy savings in the range of $200 would also reduce paybacks to less than six years. These energy savings would require either significantly higher fuel costs (greater than $1.50 per therm) or very high usage (around 120 gallons per day). For current incremental costs, the water heater efficiency would need to be similar to that of a heat pump water heater to deliver a six year payback.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Simple Retrofit High-Efficiency Natural Gas Water Heater Field Test

High-performance water heaters are typically more time consuming and costly to install in retrofit applications, making high performance water heaters difficult to justify economically. However, recent advancements in high performance water heaters have targeted the retrofit market, simplifying installations and reducing costs. Four high efficiency natural gas water heaters designed specifically for retrofit applications were installed in single-family homes along with detailed monitoring systems to characterize their savings potential, their installed efficiencies, and their ability to meet household demands. The water heaters tested for this project were designed to improve the cost-effectiveness and increase market penetration of high efficiency water heaters in the residential retrofit market. The retrofit high efficiency water heaters achieved their goal of reducing costs, maintaining savings potential and installed efficiency of other high efficiency water heaters, and meeting the necessary capacity in order to improve cost-effectiveness. However, the improvements were not sufficient to achieve simple paybacks of less than ten years for the incremental cost compared to a minimum efficiency heater. Significant changes would be necessary to reduce the simple payback to six years or less. Annual energy savings in the range of $200 would also reduce paybacks to less than six years. These energy savings would require either significantly higher fuel costs (greater than $1.50 per therm) or very high usage (around 120 gallons per day). For current incremental costs, the water heater efficiency would need to be similar to that of a heat pump water heater to deliver a six year payback.

03 NATURAL GAS↗

Consensus on Intermediate Scale Salt Field Test Design

This report summarizes the first stage in a collaborative effort by Sandia, Los Alamos, and Lawrence Berkeley National Laboratories to design a small-diameter borehole heater test in salt at the Waste Isolation Pilot Plant (WIPP) for the US Department of Energy Office of Nuclear Energy (DOE-NE). The intention is to complete test design during the remainder of fiscal year 2017 (FY17), and the implementation of the test will begin in FY18. This document is the result of regular meetings between the three national labs and the DOE-NE, and is intended to represent a consensus of these meetings and discussions.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Experiments and Modeling to Support Field Test Design

Disposition of heat-generating nuclear waste (HGNW) remains a continuing technical and sociopolitical challenge. We define HGNW as the combination of both heat generating defense high level waste (DHLW) and civilian spent nuclear fuel (SNF). Numerous concepts for HGNW management have been proposed and examined internationally, including an extensive focus on geologic disposal (c.f. Brunnengräber et al., 2013). One type of proposed geologic material is salt, so chosen because of its viscoplastic deformation that causes self-repair of damage or deformation induced in the salt by waste emplacement activities (Hansen and Leigh, 2011). Salt as a repository material has been tested at several sites around the world, notably the Morsleben facility in Germany (c.f. Fahland and Heusermann, 2013; Wollrath et al., 2014; Fahland et al., 2015) and at the Waste Isolation Pilot Plant (WIPP) near Carlsbad, NM. Evaluating the technical feasibility of a HGNW repository in salt is an ongoing process involving experiments and numerical modeling of many processes at many facilities.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Ion Mobility Spectrometer Field Test

The Morpho Saffran Itemizer 4DX Ion Mobility Spectrometer previously used to detect uranium signatures in FY16 was used at the former New Brunswick Facility, a past uranium facility located on site at Argonne National Laboratory. This facility was chosen in an attempt to detect safeguards relevant signatures and has a history of processing uranium at various enrichments, chemical forms, and purities; various chemicals such as nitric acid, uranium fluorides, phosphates and metals are present at various levels. Several laboratories were sampled for signatures of nuclear activities around the laboratory. All of the surfaces that were surveyed were below background levels of the radioanalytical instrumentation and determined to be radiologically clean.

36 MATERIALS SCIENCE↗

Field Testing of Telemetry for Demand Response Control of Small Loads

The electricity system in California, from generation through loads, must be prepared for high renewable penetration and increased electrification of end uses while providing increased resilience and lower operating cost. California has an aggressive renewable portfolio standard that is complemented by world-leading greenhouse gas goals. The goal of this project was to evaluate methods of enabling fast demand response (DR) signaling to small loads for low-cost site enablement. We used OpenADR 2.0 to meet telemetry requirements for providing ancillary services, and we used a variety of low-cost devices coupled with open-source software to enable an end-to-end fast DR. The devices, architecture, implementation, and testing of the system is discussed in this report. We demonstrate that the emerging Internet of Things (IoT) and Smart Home movements provide an opportunity for diverse small loads to provide fast, low-cost demand response. We used Internet-connected lights, thermostats, load interruption devices, and water heaters to demonstrate an ecosystem of controllable devices. The system demonstrated is capable of providing fast load shed for between 20 dollars and $300 per kilowatt (kW) of available load. The wide range results from some loads may have very low cost but also very little shed capability (a 10 watt [W] LED light can only shed a maximum of 10 W) while some loads (e.g., water heaters or air conditioners) can shed several kilowatts but have a higher initial cost. These costs, however, compare well with other fast demand response costs, with typically are over $100/kilowatt of shed. We contend these loads are even more attractive than their price suggests because many of them will be installed for energy efficiency or non-energy benefits (e.g., improved lighting quality or controllability), and the ability to use them for fast DR is a secondary benefit. Therefore the cost of enabling them for DR may approach zero if a software-only solution can be deployed to enable fast DR after devices are installed for other reasons. We recommend that the DR research community continue to engage with the IoT community to encourage the use of documented and open development interfaces. A library of device drivers and machine-readable interface specifications would significantly reduce the burden on users or system integrators for deploying systems in large numbers of buildings in California.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experiments and Modeling to Support Field Test Design

Salt repositories continue to be a primary concept for disposal of heat-generating nuclear waste (HGNW). For the past several years, efforts have focused on the in-drift disposal concept (e.g. Hansen and Leigh 2011; Stauffer et al. 2013; Jordan et al. 2015a,b,c; Bourret et al. 2016; Hansen et al. 2016; Bourret et al. 2017; Johnson et al. 2017a,b; Kuhlman et al. 2017). Ongoing research efforts aim to improve understanding of the behavior of the salt backfill surrounding HGNW sources, the responses of drift walls to heat sources, and the chemistry and chemical evolution of brine in such environments.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

On-Site Inspection RadioIsotopic Spectroscopy (Osiris) System-Integration and Field-Testing Report

We have designed a system for the acquisition and analysis of high-resolution gamma-ray spectra during on-site inspections under the Comprehensive Nuclear-Test-Ban Treaty (CTBT). The On-Site Inspection RadioIsotopic Spectroscopy—OSIRIS —gamma-ray spectrometer is a mechanically-cooled, battery-powered ORTEC IDM-200V, chosen to avoid the need for liquid nitrogen during on-site inspections. The spectrometer is controlled and the spectral data analyzed by a Panasonic Toughbook notebook computer. Spectral data analysis is similar to that performed by traditional gamma-ray spectrometers, except the OSIRIS gamma-ray spectral data are filtered to display only radioisotopic information relevant to CTBT on-site inspections, for example, the fission-product isotope Zr-95 and its daughter isotope Nb-95. The OSIRIS software assists the user during operation with software checklists for startup and shutdown, and menu-selected display windows during energy calibration and data acquisition. OSIRIS can be operated in either sample-counting mode or the in-situ mode. In this report, the extensive system-integration tests of the OSIRIS system carried out in 2015-2017 are described, including tests at Idaho National Laboratory, at the Nevada National Security Site (formerly, the Nevada Test Site), and at Pacific Northwest National Laboratory in Richland, Washington. We also note recent software enhancements and the steps to our successful commercialization of OSIRIS.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Preliminary Interpretations from Fall 2018 Field Test at Ne’ot Hovav

Presentation conclusions: Conservative tracer transport was reasonably consistent with earlier tests between RH11c and RH11a; No attempt to model bentonite colloids because of minimal elevation of Al concentrations over background; Modeling confirms what we knew already for Cs and Ce; Cs transports as solute that sorbs in matrix (after diffusion into matrix); Ce transports as colloid that is rapidly filtered; Sr not modeled, but qualitatively appears consistent with combination of colloid and solute transport

54 ENVIRONMENTAL SCIENCES↗

Cost-Optimized Cold Climate Heat Pump Development and Field Test

Cold climate heat pumps (CCHPs) expand the heat pump market to climates where heating demand is dominant. They can achieve more than 70% energy savings compared with electric resistance heating and operate at lower cost than using tank-stored propane to fuel a furnace. A high-efficiency heat pump with a heating seasonal performance factor (HSPF)—as defined by the Air-Conditioning, Heating, and Refrigeration Institute (AHRI 2008)—greater than 10.0 would be more efficient than gas heating in terms of source energy. However, developing a cost-effective CCHP involves some challenges. A typical single-speed, air-source heat pump (ASHP) with an HSPF of 7.7 Btu/Wh does not work well under cold outdoor temperature conditions typical of cold climate locations for four major reasons: 1. Discharge temperature is too high—The low suction pressure and high compression pressure ratio at low ambient temperatures causes high compressor discharge temperatures in excess of the maximum limit for many of the compressors on the market. Furthermore, system charge of a heat pump is usually optimized in the cooling mode, which leads to overcharge conditions in the heating mode, further increasing the discharge temperature. 2. Heating capacity is insufficient if sized to meet the building design cooling load— Heating capacity of a single-speed heat pump decreases with ambient temperature. The heating capacity at -13°F (-25°C) typically decreases to 20%–40% of the rated heating capacity at 47°F (8.3°C) (~equivalent to the rated cooling capacity at 95°F [35°C]). Therefore, a single-speed heat pump, typically sized to match the building design cooling load, cannot provide adequate heating capacity to match the building heating load at low ambient temperatures. The capacity deficit is filled by inefficient resistance heat, thus lowering the system efficiency and significantly increasing power demand. 3. Cyclic loss is significant if sized to meet the building design heating load—If a single-speed heat pump is sized to meet the heating load, it will be significantly oversized relative to the cooling load in many cold climates. This will cause excessive on/off cyclic loss during the cooling and heating operations at moderately low ambient temperatures. Thus, capacity modulation capability (e.g., using a variable-speed or multi-stage compressor) is necessary for a CCHP, which uses its full capacity to meet the peak heating load and partial capacity to meet the cooling and part-load heating loads. 4. Coefficient of performance (COP) is low—Heating COP degrades significantly at low ambient temperatures owing to the large temperature difference between the heat source and sink. A target CCHP should be sized to meet the building design heating load while minimizing the cyclic loss for the cooling and heating operations at moderate ambient temperatures.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Maintaining Continuity of Knowledge of Spent Fuel Pools: Field Testing (Final Report)

Maintaining Continuity of Knowledge (CoK) of spent fuel throughout its life cycle is a key objective of the International Atomic Energy Agency (IAEA). This report describes a project in which two specific technologies, cameras with infrared (IR) imaging capabilities and imaging sonar, were tested to determine their effectiveness in augmenting optical surveillance cameras currently used for maintaining CoK for spent nuclear fuel (SNF) staged in spent fuel pools. Furthermore, the project identifies any modifications required to the technologies to facilitate deployment for international safeguards purposes. This report presents results for the imaging sonar tested at Sandia National Laboratories (SNL) in a mockup spent nuclear fuel pool and for the IR-capable cameras tested by Pacific Northwest National Laboratory (PNNL) in the Oregon State University Training, Research, Isotopes, General Atomics (TRIGA) research reactor.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Field Testing of Earth Penetrators [Slides]

This presentation outlines a series of experiments Los Alamos National Laboratory led as part of the Stockpile Responsiveness Program in 2019. The mid-scale experiments were designed to exercise case geometry perturbations and assess their performance characteristics with respect to mitigating penetrator angle of attack. The material was prepared for an HDBT workshop held at LANL January 19th, 2023.

42 ENGINEERING↗