Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “field deployment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Low-Level Mesoscale and Cloud-Scale Interactions Promoting Deep Convection Initiation

Data from scanning radars, radiosondes, and vertical profilers deployed during three field campaigns are analyzed to study interactions between cloud-scale updrafts associated with initiating deep moist convection and the surrounding environment. Three cases are analyzed in which the radar networks permitted dual-Doppler wind retrievals in clear air preceding and during the onset of surface precipitation. These observations capture the evolution of (i) the mesoscale and boundary layer flow, and (ii) low-level updrafts associated with deep moist convection initiation (CI) events yielding sustained or short-lived precipitating storms. The elimination of convective inhibition did not distinguish between sustained and unsustained CI events, though the vertical distribution of convective available potential energy may have played a role. The clearest signal differentiating the initiation of sustained versus unsustained precipitating deep convection was the depth of the low-level horizontal wind convergence associated with the mesoscale flow feature triggering CI, a sharp surface wind shift boundary, or orographic upslope flow. The depth of the boundary layer relative to the height of the LFC failed to be a consistent indicator of CI potential. Widths of the earliest detectable low-level updrafts associated with sustained precipitating deep convection were ~3–5 km, larger than updrafts associated with surrounding boundary layer turbulence (~1–3 km wide). It is hypothesized that updrafts of this larger size are important for initiating cells to survive the destructive effects of buoyancy dilution via entrainment.

54 ENVIRONMENTAL SCIENCES↗

Long-Term Infrasound Sensor Calibration and Characterization

Previous testing has shown that infrasound sensors deployed in the field can exhibit notable deviations from their nominal, lab-based calibrations. These variations may be due to changes in environmental conditions, long-term sensor drift, or other unresolved features. In early 2018, we installed two identical infrasound elements with five infrasound sensors at each element (Chaparral M50A, Chaparral M64LN, CEA/Martec MB2005, CEA/Seismowave MB3a, and Hyperion IFS-5113A). These sensors were accepted or under consideration for use in the International Monitoring System network of the Comprehensive Nuclear-Test-Ban Treaty. Each element had all sensors connected to a single digitizer and port to the atmosphere. We also recorded instrument enclosure air temperature and humidity and external air temperature. Using the MB2005 as the reference, we examine the relative sensor response (both magnitude and phase) as a function of time and frequency and compare it with quarterly laboratory calibrations and environmental conditions. Here, we find that the magnitude response for all sensors exhibits some variability in both the lab and field, with the amplitude variations often >5%. The field-based variations are more severe and occur on both long-term (months) and short-term (hours) timescales. Short-term variability correlates with changes in environmental conditions and is considerable (up to 25%) for the Chaparral M50A and noticeable (∼5%) for the French Alternative Energies and Atomic Energy Commission (CEA) MB3a. Long-term magnitude variability for the Chaparral M50A was up to 50% and does not clearly correlate with environmental conditions. The other sensors show some long-term magnitude offsets, but they have relatively stable responses in the conditions we examined. The MB3a also displays some frequency-dependent magnitude variability and shows a minor dependence on temperature. Phase estimates are stable and near zero for all sensors tested. These results strongly suggest sensor response and variability due to environmental conditions should be considered in future infrasound data interpretation and sensor selection and development.

Fee, David↗

Optimizing Classifiers for Radionuclide Identification

Identifying threat nuclear materials is a critical for the prevention of acts of nuclear terrorism on the homeland. For this purpose, many radionuclide identification devices are deployed in the field. However, these will not necessarily be in the hands of non-experts, therefore these devices need to provide ready-made answers for the personnel in the field. This is where advanced algorithms are employed to both interpret the data and provide the identification of the nuclear material being interrogated. We took a machine learning approach to identification, by using training and validation data sets to create and optimize classifiers which determine which radionuclide is consistent with the data. The classifiers investigated were the Random Forest, Decision Tree, Support Vector Machine, and XG Boost and their performance was judged using the F1 Score for both hyperparameter tuning and comparison. In the end, we found out that the Random Forest Classifier worked the best based off the F1 Score they got which was 0.98.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Enhanced Control, Optimization, and Integration of Distributed Energy Applications (ECO-IDEA)

With support from the U.S. Department of Energy Solar Energy Technologies Office, the National Renewable Energy Laboratory (NREL) partnered with Xcel Energy, Schneider Electric, Varentec, and Electric Power Research Institute (EPRI) to meet the goals of the Enabling Extreme Real-Time Grid Integration of Solar Energy (ENERGISE) program. This project developed and validated an innovative data-enhanced hierarchical control architecture that enables the efficient, reliable, resilient, and secure operation of future distribution systems with a high penetration of distributed energy resources like solar energy. The architecture enables a hybrid control approach where a centralized control layer is complemented by distributed control algorithms for solar inverters and autonomous control of grid edge devices. It is fully interoperable and includes all the cybersecurity aspects necessary for reliable and secure system operation. The hybrid approach can seamlessly integrate multiple voltage-regulation technologies, both at central and grid-edge levels, which enables reliable and efficient system operation in the face of unpredictable conditions. The overarching goal of the Eco-Idea project is to develop, validate, and deploy a unique and innovative Data-Enhanced Hierarchical Control (DEHC) architecture that comprehensively addresses the formidable challenges associated with proliferation of high penetration of distributed PV such as reverse power flows, transients from variability of PV systems, feeder load balancing, and voltage stability. These issues are exposing the weaknesses of existing grid operations and controls - including, but not limited to, lack of grid situational awareness, heuristic and slow-acting control actions, latency of control for emergency situations, and points of failure in communications. The proposed architecture will comprehensively resolve the deficiencies of current operational settings - where monitoring and control solutions proposed across industry and academia may not be interoperable and may not coexist in the same system - and will enable an efficient, reliable, resilient, and secure operation of future distribution systems with penetration of solar energy well beyond current limits. The DEHC architecture was developed and validated rigorously through hardware-in-loop simulations in the laboratory environment and deployed on the field.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Blockchain for Fault-Tolerant Grid Operations

Radial topology and vast geographic coverage make distribution systems prone to widespread power outages upon the failure of a single (or multiple) upstream component. Fault-handling algorithms depend heavily on correct estimations of the system’s state to effectively isolate the affected area and reduce the number of affected customers while maintaining operational safety. The work described here leverages the core features of distributed, consensus-based decision-making processes and the immutability of blockchain, and demonstrates their value in improving fault-tolerant grid operations. In this work, blockchain was used to create a trusted data-sharing platform that enables independent actors to reconstruct the system state; this enables distributed resources to make intelligent decisions with limited knowledge. Although the process requires data sharing, its algorithms have been designed to limit the amount of private information that is exchanged, which helps preserve business-sensitive data and maintain customer privacy. In addition, by reducing the information that must be shared, the communication requirements are also reduced; (however, an in-depth analysis of the communication requirements is beyond the scope of this project). The proposed use cases are intended to represent a foundational basis for third parties to develop functional solutions that can eventually be deployed in the field. To further provide guidance, the envisioned use cases have incorporated design requirements that consider the blockchain characteristics and a need to limit information from surrounding resources, which preserve the assumption and the possibility that such resources could belong to different entities. This report presents a detailed design of the three use cases with the tools needed to enable the analysis being tested. The implemented gross error detection method can detect mismatches when the error exceeds 3.8 times the sensor’s rated accuracy. Detection of the circuit breaker state successfully identified the correct states across all simulation tests. A distribution-system power-flow solution in the simulator OpenDSS generally possesses a convergency tolerance of 0.01% on the voltage magnitude. The evaluation of possible reconnection using voltage magnitude—preserving the data ownership—has a voltage magnitude difference smaller than 0.001% from the OpenDSS result. The results preserving data ownership have a difference within the expected power flow tolerance with full knowledge of the system, which surpasses expectations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Creation of Laboratory-scale Testbed for Autonomous Monitoring and Control of Subsurface Systems

This report describes the results of an LDRD project aiming to develop a laboratory-scale testbed for autonomous subsurface monitoring and control systems. Modifications were made to an existing polyaxial loading frame to incorporate electrical resistivity tomography (ERT) and acoustic emission (AE) monitoring systems. This allows engineered subsurface processes to be studied under realistic temperatures and stresses in a scaled-down laboratory environment with similar monitoring systems as are deployed in field-scale systems. The paper outlines some challenges that were faced in implementing the ERT system at the laboratory scale and the solutions that were devised. Results are shown from two demonstration tests—one focusing on the ERT system, and one focusing on the AE system.

42 ENGINEERING↗

Advanced Sensors for In-Situ Amine Degradation Monitoring in Post-Combustion Carbon Capture

In order to improve the long-term performance of post-combustion carbon capture technologies, improvements to the detection of solvent degradation or reduction in CO2 capture efficiency are necessary. A pair of sensors were deployed to the National Carbon Capture Center’s (NCCC) to monitor CO2 capture and solvent degradation. The CO2 sensors were located to measure before capture and after capture concentrations of CO2 to measure the capture efficiency of the solvent system. Amine degradation sensors were located at four locations along the main solvent lines corresponding to CO2 loading and temperature: hot rich, cold rich, hot lean, and cold lean. Experimental results from laboratory tests using the sensors are shown, along with prototype designs that were deployed to the field site.

Brister, Matthew↗

How Much Attenuation Extinguishes mm-Wave Vertically Pointing Radar Return Signals?

Vertically pointing radars (VPRs) operating at millimeter wavelengths measure the power return from raindrops enabling precipitation retrievals as a function of height. However, as the rain rate increases, there are combinations of rain rate and rain path length that produce sufficient attenuation to prevent the radar from detecting raindrops all the way through rain shafts. This study explores the question: Which rain rate and path length combinations completely extinguish radar return signals for VPRs operating between 3 and 200 GHz? An important step in these simulations is converting attenuated radar reflectivity factor into radar received signal-to-noise ratio (SNR) in order to determine the range where the SNR drops below the receiver detection threshold. Configuring the simulations to mimic a U.S. Department of Energy Atmospheric Radiation Mission (ARM) W-band (95 GHz) radar deployed in Brazil, the simulation results indicate that a W-band radar could observe raindrops above 3.5 km only when the rain rate was less than approximately 4 mm h -1 . The deployed W-band radar measurements confirm the simulation results with maximum observed heights ranging between 3 and 4.5 km when a surface disdrometer measured 4 mm h -1 rain rate (based on 25-to-75 percentiles from over 25,000 W-band radar profiles). In summary, this study contributes to our understanding of how rain and atmospheric gas attenuation impacts the performance of millimeter-wave VPRs and will help with the design and configuration of multi-frequency VPRs deployed in future field campaigns.

54 ENVIRONMENTAL SCIENCES↗

PROTOCALC, a W -band Polarized Calibrator for Cosmic Microwave Background Telescopes: Application to Simons Observatory and CLASS

Current- and next-generation cosmic microwave background (CMB) experiments will measure polarization anisotropies with unprecedented sensitivities. The need for high precision in these measurements underscores the importance of gaining a comprehensive understanding of instrument properties, with a particular emphasis on the study of the beam properties, and especially their polarization characteristics and the measurement of the polarization angle. In this context, a major challenge lies in the scarcity of millimeter polarized astrophysical sources with sufficient brightness and calibration knowledge to meet the stringent accuracy requirements of future CMB missions. This led to the development of a drone-borne calibration source designed for the frequency band centered on approximately 90 GHz, matching a commonly used channel in ground-based CMB measurements. The Prototype Calibrator for Cosmology, PROTOCALC, has undergone thorough in-lab testing, and its properties have been subsequently modeled through simulation software integrated into the standard Simons Observatory analysis pipeline. Moreover, the PROTOCALC system has been tested in the field, having been deployed twice on calibration campaigns with CMB telescopes in the Atacama Desert. The data collected constrain the roll angle of the source with a statistical accuracy of 0$^°_•$045.

79 ASTRONOMY AND ASTROPHYSICS↗

Searay Autonomous Offshore Power System AOPS: Results of Sea Trials and Payload Support Demonstration

As the offshore energy sector looks to fully implement resident, autonomous, robotic, digital systems offshore, one missing piece of the puzzle is remote power generation. Further complicating these efforts are the owner/operators’ move towards net zero operations. Here, the combination represents a significant dilemma for the offshore energy industry: if gensets and topside vessels are not appropriate or practical power sources for future resident systems, how will these needed cost and carbon-saving innovations come to market and get deployed in the field?

16 TIDAL AND WAVE POWER↗

Cybersecurity Certification Standard for Distributed Energy Resources

Cybersecurity Certification Standard for Inverter Based Resources led by UL, and contributed to by NREL, is a certification standard for devices and their cyber security practices. The standard, which is being developed and led by UL, contains certification and testing processes for the devices to be certified before they are deployed in the field. The importance of the standard is to ensure that all DER devices have all the five pillars of cybersecurity, in which the baseline cybersecurity posture of the DER industry will be elevated.

certification standard↗

Quantum Aspects of Natural Top Quark Condensation

In top quark condensation the Brout-Englert-Higgs (BEH) boson is a $\bar{t}t$ bound state. With a UV completion of a single coloron exchange interaction, a recent semiclassical treatment gave a novel theory of the BEH boson as an extended object with composite scale $M_0\sim 6$ TeV. Presently we obtain the semiclassical theory as an effective action, using the source/Legendre transformation techniques of Jackiw, \etal, and fermion loop effects in the large-$N_c$ limit by deploying an auxiliary field to implement the sum of leading fermion loop diagrams. The theory remains natural at the loop level, with fine tuning at the level of a few %, and the effective coupling of the 4-fermion interaction, $\bar{g}_0^2$, is significantly enhanced by quantum loops over the fundamental coloron coupling, $g_0^2$. Hence a relatively weaker ``topcolor'' theory can produce critical coupling in the effective BEH bound state theory.

Hill, Christopher T. [Fermilab; Wisconsin U., Madi↗

Commercialization of the Transportation-Security, Tracking, and Reporting System (T-STAR)

The Transportation-Security, Tracking, and Reporting System (T-STAR) was developed by the National Nuclear Security Administration, NA-21, Office of Radiological Security (ORS) to provide a transportation security system for detection and tracking during transport of Category 1 and Category 2 radiological material. Few off-the-shelf systems for conveyance tracking offer detection of a cargo compartment breach or a removal of the cargo. Systems that do offer this capability often require permanent installation through modifying of the conveyance itself. This is not sustainable in many countries where ORS is building use, storage, and transport security capacity. The development of T-STAR has moved from fielding robust prototypes deployed in countries ranging from North America, Latin America and Central Asia to a commercially produced product that can now be deployed to provide enhanced security during transit. Each prototype deployment resulted in important lessons learned, which informed the requirements for the final commercial product. T-STAR uses both cellular and Iridium satellite modems to provide redundant communications to provide the configuration, status, and alerts to a server monitoring the shipment, which is accessible using a multilanguage browser-based user interface. A wireless security system employing using Z-wave sensors for intrusion detection located in the conveyance provide low cost but effective solution for a wide range of conveyance types. Additional capabilities include the ability to monitor a vehicles’ CANBUS (Controller Area Network) system, an ethernet port for high throughput sensor information such as video cameras, and the ability to power and use advanced external sensor payloads. These features make the T-STAR a capable and expandable security gateway that can be deployed on a variety of conveyances from box trucks to open trailers. The ability to provide tracking, monitoring, and detection provide a key component in overall best practices designed to protect shipments of radioactive material.

Schultze, Michael [ORNL] (ORCID:0000000283205671)↗

PV Lifetime Project (2021 NREL Annual Report)

DOE's PV Lifetime project was initiated in 2016 with the goal of accurately characterizing the early-life evolution of photovoltaic (PV) field performance. Different PV cell and module technologies result in different initial performance loss rates due to effects like light-induced degradation (LID) and light & elevated temperature-induced degradation (LeTID). To accurately characterize the initial field performance loss requires the use of high-accuracy indoor IV curve measurements at standard test conditions. Therefore, PV modules involved in this study are removed from the field once or twice per year and brought indoors for measurement. Current samples deployed and monitored in this way include Jinko Solar (2016), Trina Solar (2016), Hanwha Q-Cells (2017), Panasonic (2018), LG (2018), Canadian Solar (2018), Mission Solar (2019). More recently, modules from Sunpreme (2019), and LONGi (2020) have been deployed but not yet analyzed. Overall annual performance loss rates are as follows: our first modules to be deployed (Jinko and Trina) have annual median performance loss rate between -0.4%/yr and -0.9%/yr, mainly concentrated in the first year. The QCells mono-PERC and multi-PERC modules have an annual degradation rate of -0.76%/yr and -0.69%/yr respectively, also concentrated in the first year of operation. Panasonic and LG modules displayed negligible performance loss in the past two years, at 0.1%/yr and -0.0%/yr respectively. They also were the only modules with initial IV curve measurements consistently above the nameplate rating. Possibly relatedly, these are also the only two N-type silicon module types analyzed so far. Canadian Solar multi-PERC modules demonstrated a -1.3%/yr degradation rate which actually accelerated in the past year, so this will be a module type to monitor in future years. Mission Solar modules exhibited strong recoverable performance loss, consistent with LeTID susceptibility. (The same is true for the Jinko JKM260 module type). Annual performance loss actually showed improvement in time at +0.3%/yr after 2 years in the field, although the module initially was measured at 3% below nameplate rating. These modules could therefore be experiencing a form of post-LeTID recovery. Initial measurements have been conducted on the next two module types - Sunpreme n-HIT and LONGi bifacial mono-PERC. We will report on initial year-1 performance change for these modules in the next PV Lifetime annual report. For the remaining modules, an additional year of field exposure will provide greater certainty in annual degradation rates, particularly for those with degradation concentrated in the initial year of field deployment.

14 SOLAR ENERGY↗

Portable diagnostic package for Thomson scattering and optical emission spectroscopy on Princeton field-reversed configuration 2 (PFRC 2)

An Advanced Research Projects Agency-Energy funded diagnostic system has been deployed to the Princeton field-reversed configuration 2 (PFRC-2) device, located at Princeton Plasma Physics Laboratory. The Portable Diagnostic Package (PDP), designed at Oak Ridge National Laboratory, allows for the measurement of Thomson Scattering (TS) for electron density and temperature and Optical Emission Spectroscopy (OES) for ion temperature, impurity density, and ion velocity. A tunable spectrometer on the PDP with three gratings provides the flexibility to measure low (1 eV) and high (1000 eV) electron temperature ranges from TS. Additionally, using a second spectrometer, the OES diagnostic can survey light emission from various ion excitation levels for wide wavelength ranges. The electron density (<2 × 10 19 m –3 ) of plasmas generated in PFRC-2 has been below the PDP TS discrimination threshold, which has made TS signal detection challenging against a high-background of laser stray light. The laser stray light was iteratively reduced by making modifications to the entrance and exit geometry on PFRC-2. Rayleigh scattering experiments on PFRC have yielded the TS discrimination sensitivity to be >1 × 10 20 m –3 for the PDP. A recently implemented narrow-band notch spectral filter that masks the second harmonic 532 nm Nd:YAG laser wavelength has increased the system’s TS light discrimination sensitivity 65 times compared to the instance when the notch filter was not implemented. The hardware implementation including design changes to the flight tubes and Brewster windows will be discussed, along with results from Rayleigh and rotational Raman scattering sensitivity analyses, which were used to establish a quantitative figure of merit on the system performance. Further, the Raman scattering calibration with the notch filter has improved the PDP electron density threshold to 1 ± 0.5 × 10 18 m –3 .

47 OTHER INSTRUMENTATION↗

Optimizing Bifacial PV Systems (Q3 FY2020 Project Report)

This project has four main technical objectives. Develop and improve bifacial performance models by adding the capability to evaluate electrical behavior and performance of bifacial modules and arrays under realistic field conditions including irradiance variability caused by racking, module frame, and position in the array. Instrument and monitor performance of fielded bifacial systems to validate performance models and to measure, analyze and publish on bifacial energy gain. These should include both research and commercial bifacial systems and cover a variety of deployment applications. Evaluate optimal bifacial system designs using simulations leveraging high performance computing, and also using full sized and miniaturized experimental field deployments. Establish and contribute to international test standards for bifacial system performance, testing, and safety, and work with the community to establish installation and siting best practices.

14 SOLAR ENERGY↗

2021 Q1 Project Report: Optimized Bifacial PV Systems (Q1 FY2021 Project Report)

This project has four main technical objectives: 1) Develop and improve bifacial performance models by adding the capability to evaluate electrical behavior and performance of bifacial modules and arrays under realistic field conditions including irradiance variability caused by racking, module frame, and position in the array. 2) Instrument and monitor performance of fielded bifacial systems to validate performance models and to measure, analyze and publish on bifacial energy gain. These should include both research and commercial bifacial systems and cover a variety of deployment applications. 3) Evaluate optimal bifacial system designs using simulations leveraging high-performance computing, and also using full sized and miniaturized experimental field deployments. 4) Establish and contribute to international test standards for bifacial system performance, testing, and safety, and work with the community to establish installation and siting best practices.

42 ENGINEERING↗

WREF field profiling lidar

The field profiling lidar #ZX300-1945 was deployed on the ground in an open field 880 m south of the NEON tower and tower profiling lidar (ZX300-1381). The zip files contain high frequency data. The excel files are 10-min averages.

17 WIND ENERGY↗