Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “fault analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

IBR Black Model Lessons Learned (C45)

Blackbox modelling for SC analysis is a possible solution. Accuracy can be acceptable even without having vendor control diagrams. Blackbox modelling is not as user friendly as a generic model. Is an NDA required to share a vendor Blackbox model for SC analysis? Difference in VRT detection and injection logics. Angle rotation is not addressed. Current limitation logic during unbalanced faults is not clear.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Analysis of Grid-Forming Inverter Controls for Grid-Connected and Islanded Microgrid Integration

Autonomous grid-forming (GFM) inverter testbeds with scalable platforms have attracted interest recently. In this study, a self-synchronized universal droop controller (SUDC) was adopted, tested, and scaled in a small network and a test feeder using a real-time simulation tool to operate microgrids without synchronous generators. We presented a novel GFM inverter control adoption to better understand the dynamic behavior of the inverters and their scalability, which can impact the distribution system (DS). This paper provides a steady-state and transient analysis of the GFM power inverter controller via simulation to better understand voltage and frequency stabilization and ensure that the critical electric loads are not affected during a prolonged power outage. The controllers of the GFM inverter are simulated in HYPERSIM to examine voltage and frequency fluctuations. This analysis includes assessing the black start capability for photovoltaic microgrids, both grid-connected and islanded, during transient fault conditions. The high photovoltaic PV penetration levels open exciting opportunities and challenges for the DS. The GFM inverter control demonstrated appropriate response times for synchronization, connection, and disconnection to the grid. The DS has become more resilient and independent of fossil fuels by increasing the penetration of inverter-based distributed energy resources (DERs).

Ward, Laura (ORCID:0000000345501581)↗

Fault localization in a microfabricated surface ion trap using diamond nitrogen-vacancy center magnetometry

Here, as quantum computing hardware becomes more complex with ongoing design innovations and growing capabilities, the quantum computing community needs increasingly powerful techniques for fabrication failure root-cause analysis. This is especially true for trapped-ion quantum computing. As trapped-ion quantum computing aims to scale to thousands of ions, the electrode numbers are growing to several hundred, with likely integrated photonic components also adding to the electrical and fabrication complexity, making faults even harder to locate. In this work, we used a high-resolution quantum magnetic imaging technique, based on nitrogen-vacancy centers in diamond, to investigate short-circuit faults in an ion trap chip. We imaged currents from these short-circuit faults to ground and compared them to intentionally created faults, finding that the root cause of the faults was failures in the on-chip trench capacitors. This work, where we exploited the performance advantages of a quantum magnetic sensing technique to troubleshoot a piece of quantum computing hardware, is a unique example of the evolving synergy between emerging quantum technologies to achieve capabilities that were previously inaccessible.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Validating Protection System Behavior with Machine Learning in a Master State Overseer

As power system protection devices continue the widespread transition from analog to digital, they become increasingly intricate. The internal functions and communication between critical grid components must now be significantly more complex to keep up with the demands of the modern smart grid. This brings increased difficulty in maintenance and monitoring, making it harder to identify potential misoperation, power anomalies, and cyber threats. Such issues are often only pinpointed after an exhaustive and costly post-mortem analysis, when a major outage or damage has already occurred. A solution is needed for validating protection systems as they operate, independently evaluating grid state and confirming whether the protection system is behaving accordingly. As opposed to incident response, this acts as a constant verification mechanism that raises a flag when subtler issues are noticed, catching them earlier and preventing larger incidents. This work presents the implementation of such a system, expanding on the prototype developed by the authors in a previous paper. This is accomplished with a machine learning (ML) system capable of validating the performance of protection systems by classifying anomalous events and characterizing protection system responses based solely on available current and voltage measurements. Additionally, this system is contextualized within a larger, modular Master State awareness Overseer (MSO) framework, responsible for monitoring, analyzing, and managing an electric grid.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

TOUGH3-FLAC3D: a modeling approach for parallel computing of fluid flow and geomechanics

The recent development of the TOUGH3 code allows for a faster and more reliable fluid flow simulator. At the same time, new versions of FLAC3D are released periodically, allowing for new features and faster execution. In this paper, we present the first implementation of the coupling between TOUGH3 and FLAC3Dv6/7, maintaining parallel computing capabilities for the coupled fluid flow and geomechanical codes. We compare the newly developed version with analytical solutions and with the previous approach, and provide some performance analysis on different meshes and varying the number of running processors. Finally, we present two case studies related to fault reactivation during CO 2 sequestration and nuclear waste disposal. The use of parallel computing allows for meshes with a larger number of elements, and hence more detailed understanding of thermo-hydro-mechanical processes occurring at depth.

58 GEOSCIENCES↗

Safety Risk Reliability Model Library

SR2ML is a software package which contains a set of safety and reliability models designed to be interfaced with the INL developed RAVEN code. These models can be employed to perform both static and dynamic system risk analysis and determine risk importance of specific elements of the considered system. Two classes of reliability models have been developed; the first class includes all classical reliability models (Fault-Trees, Event-Trees, Markov models and Reliability Block Diagrams) which have been extended to deal not only with Boolean logic values but also time dependent values. The second class includes several components aging models. Models of these two classes are designed to be included in a RAVEN ensemble model to perform time dependent system reliability analysis (dynamic analysis). Similarly, these models can be interfaced with system analysis codes to determine failure time of systems and evaluate accident progression (static analysis).

Wang, Congjian↗

Collaborative Computing Support for Analysis Facilities Exploiting Software as Infrastructure Techniques

Prior to the public release of Kubernetes it was difficult to conduct joint development of elaborate analysis facilities due to the highly non-homogeneous nature of hardware and network topology across compute facilities. However, since the advent of systems like Kubernetes and OpenShift, which provide declarative interfaces for building fault-tolerant and self-healing deployments of networked software, it is possible for multiple institutes to collaborate more effectively since resource details are abstracted away through various forms of hardware and software virtualization. In this whitepaper we will outline the development of two analysis facilities: "Coffea-casa" at University of Nebraska Lincoln and the "Elastic Analysis Facility" at Fermilab, and how utilizing platform abstraction has improved the development of common software for each of these facilities, and future development plans made possible by this methodology.

97 MATHEMATICS AND COMPUTING↗

A Novel Simulation-Based Framework for Sensor Error Impact Analysis in Smart Building Systems: A Case Study for a Demand-Controlled Ventilation System

Sensors are one of the fundamental components for sensor-rich controls in buildings but are prone to different errors. Existing studies show that sensor errors hold a place among top-priority faults in building systems. Before we take countermeasures to mitigate the sensor errors, it is vital to prioritize key sensors and quantify the collective impacts of concurrent sensor errors. In response to this, a simulation-based methodology is introduced to conduct a comprehensive sensor error impact analysis in building systems, which adds a stochastic sensor prioritization through a sensitivity analysis on top of a commonly used deterministic sensor error quantification. The synergies of these two parts help better interpret the sensor error impacts on building energy consumption, ventilation performance, thermal comfort, etc. A sensor-rich CO2-based Demand-Controlled Ventilation system is used as a case study to demonstrate the viability of the methodology as a proof-of-the-concept. The results show that the energy savings potential and ventilation performance are mostly influenced by the accuracy of the AHU outdoor airflow sensors. The accuracy of zone level airflow sensors has a negligible impact on both energy savings and ventilation performance. The accuracy of zone CO2 sensors has more influence on the ventilation performance compared with the accuracy of zone airflow sensors. Compared with the baseline case with zero errors, the largest deviation percentages could reach 16.90% and 94.32%, respectively, in terms of the Heating, Ventilation, and Air-Conditioning (HVAC) annual energy consumption and the Outdoor Air Ratio (OAR) when multiple key sensors suffer from normal error intensities simultaneously.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analysis of permeability change in dissolving rough fractures using depth-averaged flow and reactive transport models

Many geophysical problems and engineering applications involve fluid flow through evolving faults and fractures. These situations are typical in CO 2 injection scenarios where supercritical CO 2 or CO 2 –saturated fluids are able to dissolve the solid matrix. Dissolution or precipitation within a fracture could lead to self-reinforcing or self-limiting behavior due to feedbacks from changes in permeability (k). There is limited predictive understanding of this phenomenon. Here, we investigated the case of fracture dissolution using a two-dimensional depth-averaged reactive transport model. The model simulated an acidic fluid dissolving a three-dimensional rough fracture. We observed different dissolution patterns across a wide range of geometric properties and different Peclet and Damkohler numbers (960 cases total). Despite this variation, a persistent linear increase in k with time (t) roughly manifested once the dissolution front advanced through the fracture. The time rate of change of k (k/t) is roughly constant for all simulations. The modeled rate is consistent with a theoretical value based on the parallel plates model and with experimentally derived values. Finally, the results confirm the common presence of linear time-dependence of fracture k due to self-reinforcement.

58 GEOSCIENCES↗

Remote Monitoring and Diagnostics of Pitch-Bearing Defects in an MW-Scale Wind Turbine Using Pitch Symmetrical-Component Analysis

Recently, multiple wind turbine failure databases have reviewed that the pitch system is one of the subassemblies with the highest failure rates and largest contributors to the overall downtime. Therefore, there has been an increasing interest to provide remote health monitoring for wind turbine pitch system. While most of the research articles are discussing pitch actuation system (hydraulic or electric actuator) faults only, there is very limited research on pitch-bearing-defect detection. This article provides a remote and hardware-free solution to monitor multiaxis pitch-bearing health condition called pitch symmetrical-component analysis. It leverages readily available low-resolution (100 Hz) electrical measurements, mechanical measurements, and control signals from the existing pitch control platform, and innovatively applies symmetrical-component analysis in multiphase ac system to multiaxis pitch control system and introduces multiaxis pitch-bearing degradation trending curves. This hardware-free solution can be directly applied to the existing wind turbines and successfully give the wind farm operator an early warning before multiaxis pitch bearing fails. It has been proved to be accurate, low cost, and has minimum impacts on turbine normal operation, and has been validated by field data from several North America MW-scale wind farms. This approach turns out to be the first hardware-free (no additional hardware needed) method to remotely monitor and diagnose multiaxis wind turbine pitch-bearing condition.

17 WIND ENERGY↗

Metadata Schemas and Ontologies for Building Energy Applications: A Critical Review and Use Case Analysis

With the increasing digitalization of processes throughout the lifecycle of buildings, data exchanged between stakeholders and between building systems has grown significantly. However, a lack of semantic interoperability between data in different systems is still prevalent, hindering the development of applications that can be reused across buildings and limiting the scalability of innovative solutions. Semantics refers to the description of the meaning of the data in a way that can be consistently understood by applications. Recently, several competing initiatives have been developing metadata schemas and ontologies to express this semantic information for different applications in the building domain. This paper systematically reviews these schemas and conducts an analysis of five of them to evaluate their applicability to three high-value use cases for building operations: energy audits, automated fault detection and diagnostics and optimal control. The survey finds 40 schemas published in the last 10 years but but their actual use in industry is difficult to estimate. Among the five selected ontologies, several gaps are highlighted in relation to the three use cases. Recommendations for the future include better harmonization of these initiatives, more centralized repositories and search engines for these schemas as well as better industry engagement to facilitate their adoption.

Smart Building, Sematic, Metadata, Ontology, Data ↗

3-D Geologic Controls of Hydrothermal Fluid Flow at Brady geothermal field, Nevada, USA

In many hydrothermal systems, fracture permeability along faults provides pathways for groundwater to transport heat from depth. Faulting generates a range of deformation styles that cross-cut heterogeneous geology, resulting in complex patterns of permeability, porosity, and hydraulic conductivity. Vertical connectivity (a throughgoing network of permeable areas that allows advection of heat from depth to the shallow subsurface) is rare and is confined to relatively small volumes that have highly variable spatial distribution. This local compartmentalization of connectivity represents a significant challenge to understanding hydrothermal circulation and for exploring, developing, and managing hydrothermal resources. Here, we present an evaluation of the geologic characteristics that control this compartmentalization in hydrothermal systems through 3-D analysis of the Brady geothermal field in western Nevada. A published 3-D geologic map of the Brady area is used as a basis to develop structural and geological variables that are hypothesized to control or effect permeability or connectivity. The 3-D distribution of these variables is compared to the distribution of productive and non-productive fluid flow intervals along production wells and non-productive wells via principal component analysis (PCA). This comparison elucidates which geologic and structural variables are most closely associated with productive fluid flow intervals. Results indicate that production intervals at Brady are located: (1) within or near to known and stress-loaded macro-scale faults, and (2) in areas of high fault and fracture density.

58 GEOSCIENCES↗

Distributed Quantum Error Correction for Chip-Level Catastrophic Errors

Quantum error correction holds the key to scaling up quantum computers. Cosmic ray events severely impact the operation of a quantum computer by causing chip-level catastrophic errors, essentially erasing the information encoded in a chip. Here, in this work, we present a distributed error correction scheme to combat the devastating effect of such events by introducing an additional layer of quantum erasure error correcting code across separate chips. We show that our scheme is fault tolerant against chip-level catastrophic errors and discuss its experimental implementation using superconducting qubits with microwave links. Our analysis shows that in state-of-the-art experiments, it is possible to suppress the rate of these errors from 1 per 10 s to less than 1 per month.

97 MATHEMATICS AND COMPUTING↗

Detailed space–time variations of the seismic response of the shallow crust to small earthquakes from analysis of dense array data

SUMMARY We compute high-resolution space–time variations of subsurface seismic properties from autocorrelation functions (ACF’s) of noise and local earthquakes, recorded by the Sage Brush Flat dense array deployed around the Clark branch of the San Jacinto fault. The resolved temporal changes are referred to as apparent velocity changes because they reflect both nonlinear response and variations of material properties such as cracking and damage. Apparent velocity changes are estimated at four frequency bands (10–15, 10–20, 15–30 and 20–40 Hz) for two local earthquake data sets. In one analysis, ACF’s from P- and S-wave windows of 31 small events with magnitudes below 3.1 are used to compute the apparent velocity variations with respect to the mean ACF of each phase, and we also use the mean ACF of noise data as reference to estimate the changes. In a further analysis, the temporal evolution of properties is computed using moving time windows in continuous waveform over one-hour long data with noise and earthquake signals. The apparent velocity changes and recovery times are frequency dependent and present a strong spatial variability across the array. The resolved changes are larger and recovery time shorter with data associated with higher frequencies. At frequencies larger than 15 Hz, and using the mean ACF of noise data as a reference, the apparent average velocity changes across the array during the passage of the P and S waves from the small local events are 2.5 per cent and 6 per cent, respectively. The apparent velocity changes decrease by one order of magnitude when the earthquake data are used as a reference. The relatively large changes in response to very low ground motion have important implications on nonlinear processes involving degradation and healing of the subsurface material during common earthquake shaking.

Geochemistry & Geophysics↗

An Admittance-Based Protection Scheme for Microgrids

This paper presents a novel directional protection scheme to address the unique challenges associated with protection during unbalanced faults in a distribution system with high penetration of inverter-based resources. The scheme is based on a superimposed negative sequence admittance method. A coordination approach using a unique inverse-time undervoltage element is also presented. An analysis of the scheme, the detection criteria and the coordination method are performed. Also the impact of inverter-control on the scheme is discussed. Results from extensive simulation using MATLAB/Simulink are presented to show a selective and reliable response of the scheme to unbalanced faults

Opoku, Kwasi↗

Innovations in underground hydrogen storage with multiphysics simulations, optimization, and monitoring: A review

Underground Hydrogen Storage (UHS) is a promising solution for large-scale energy storage and a critical component in advancing low-carbon energy system. Ensuring the safety and efficiency of UHS necessitates a comprehensive understanding of multiphysical interactions driven by cyclic pore fluid pressure fluctuations and coupled physicochemical processes. Here, this review examines the key geomechanical responses in UHS, including rock property variations under cyclic loading, fracture evolution and propagation, reservoir stress sensitivity, and fault stability. It also explores the impact of geochemical and microbial reactions on geomechanical characteristics. We provide an in-depth analysis of Thermal-Hydraulic-Mechanical-Chemical (THMC) coupled numerical simulations, highlighting their potential for future multi-scale modeling. Limitations of current machine learning (ML) approaches in addressing UHS challenges are highlighted, emphasizing the need for innovative ML-based methodologies. Operational strategies for hydrogen injection and production are reviewed, focusing on safety, efficiency, and economic viability. The necessity for multi-objective optimization (MOO) to balance storage efficiency, risk mitigation, and cost-effectiveness is also discussed. Current monitoring technologies are evaluated to ensure safe and efficient UHS operations. Finally, this review identifies critical knowledge gaps and underscores the importance of advancing geomechanical understanding under multiphysics-coupling. We highlight the need for ML-driven multiphysics theories, enhanced modeling techniques, and robust optimization strategies to improve UHS performance. This study serves as a comprehensive reference for future research and the large-scale implementation of UHS systems.

25 ENERGY STORAGE↗

Review of hybrid HVDC systems combining line communicated converter and voltage source converter

Hybrid HVDC system, which consists of the advantages of line commutated converter (LCC) and voltage source converter (VSC), is an emerging power transmission system. This paper presents a review of four LCC-VSC hybrid HVDC topologies. The first topology is the pole-hybrid HVDC system, in which the LCC and VSC form the positive- and negative-pole respectively. The second one is the terminal-hybrid HVDC system; in this topology one terminal adopts LCC and the other terminal adopts VSC. The series converter-hybrid HVDC system is the third topology wherein each terminal is formed by LCC and VSC in series. The fourth hybrid topology under consideration is a parallel converter-hybrid HVDC system with LCC and VSC connected in parallel in each terminal. Here, the main contribution of this paper is a comprehensive analysis and comparison of the four mentioned hybrid topologies in terms of PQ operating zone, power flow reversal method, and DC fault ride-through strategy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Probing the evolution of fault properties during the seismic cycle with deep learning

We use seismic waves that pass through the hypocentral region of the 2016 M6.5 Norcia earthquake together with Deep Learning (DL) to distinguish between foreshocks, aftershocks and time-to-failure (TTF). Binary and N-class models defined by TTF correctly identify seismograms in test with > 90% accuracy. We use raw seismic records as input to a 7 layer CNN model to perform the classification. Here we show that DL models successfully distinguish seismic waves pre/post mainshock in accord with lab and theoretical expectations of progressive changes in crack density prior to abrupt change at failure and gradual postseismic recovery. Performance is lower for band-pass filtered seismograms (below 10 Hz) suggesting that DL models learn from the evolution of subtle changes in elastic wave attenuation. Tests to verify that our results indeed provide a proxy for fault properties included DL models trained with the wrong mainshock time and those using seismic waves far from the Norcia mainshock; both show degraded performance. Our results demonstrate that DL models have the potential to track the evolution of fault zone properties during the seismic cycle. If this result is generalizable it could improve earthquake early warning and seismic hazard analysis.

58 GEOSCIENCES↗