Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “fault”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

SVM-Based Synchronized Fault Detection for 100% Renewable Microgrids

Traditional protection schemes face significant challenges when applied to microgrids with high penetrations of renewables with inverter-based resources (IBRs). The proliferation of advanced sensing and communication technologies has generated copious data, offering an opportunity to overcome these limitations using data-driven machine learning approaches. This work proposes a novel approach based on a support vector machine (SVM) for detecting faults within a 100% renewable microgrid. The approach encompasses a systematic offline training stage for the development of a linear SVM-based fault detection algorithm. This process covers offline data collection from the microgrid under study, the extraction of features such as positive- and negative-sequence components and the total harmonic distortion of the voltage and current measurements of the relays, and the design of the linear SVM-based classifier. During the online implementation, however, different classifiers can exhibit asynchronicity in detecting the fault inception at different subcycle-to-cycle period-level delays. To circumvent this asynchronicity issue, a separate algorithm is developed for each relay to estimate the fault inception time as close to the real fault time. The performance of the proposed SVM-based synchronized fault detection method is evaluated using online time-domain simulation studies on a microgrid test system. The results corroborate the reliability of the fault detection scheme when tested under various fault cases (fault types, locations, and impedances) and non-fault cases during both grid-tied and islanded operation modes.

100% microgrid↗

Characteristics and selection of near-fault simulated earthquake ground motions for nonlinear analysis of buildings

Earthquake-induced ground shaking near rupturing faults is highly sensitive to the rupture characteristics, seismic wave propagation patterns and site conditions, and field recordings of near-fault shaking are relatively sparse. These challenges complicate the assessment of the seismic performance of near-fault structures. A common approach to representing near-fault ground motion in engineering analysis is to explicitly consider and select records with strong directivity pulses (pulse records). We use three-dimensional high-resolution physics-based earthquake simulations to test this approach in the context of scenario-based ground motion record selection, and to study the important characteristics of near-fault ground shaking. We highlight the deficiencies associated with classifying near-fault simulated records as “pulse” or “non-pulse,” based on the presence of a single dominating pulse in the velocity time history. We show that this approach is inadequate for characterizing near-fault shaking on soft soils which can be dominated by both forward rupture directivity and basin amplification effects. We conduct ground motion selection experiments for the analysis of near-fault structures with and without explicit classification of the pulse features in the records, and evaluate the bias in the predicted structural demands. We find that the maximum interstory drift demands on building structures imposed by unscaled site-specific simulated ground motion records selected based on relevant spectral shape features are not sensitive to the classification of records as pulse/non-pulse. Therefore, with regard to predicting the maximum interstory drifts in near-fault buildings, we do not find justification for the binary pulse classification of near-fault records.

42 ENGINEERING↗

Common Faults and Their Prioritization in Small Commercial Buildings

This study documents faults that are commonly found in small commercial buildings based on a literature review and discussions with building commissioning experts. It also provides a list of prioritized faults based on an estimation of the prevalence, energy impact, and financial impact of each fault. A total of 39 faults were analyzed for this paper and classified by location, stage, and type. The technical complexity of detecting each type of fault based on typically available information was evaluated for each fault. The annual energy impact (AEI) and annual financial impact (AFI) of each fault were estimated based on available information. Based on these estimates, 20 top priority faults were identified. Seven out of the 20 top priority faults occur in vapor compression systems such as air-conditioning, heat pump, and refrigeration equipment. Nonstandard charging, condenser, and evaporator fouling are the most important faults for this type of equipment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Identification and repair of intermittent cable faults in nuclear power plants - 131

The nuclear industry uses cable circuits as an integral part of a plant's reactor protection system (RPS), instrumentation and control (I and C) and power distribution systems. The reliability of these systems is critical for continued operation of the world's aging nuclear fleet, as well as for safe shutdown of the reactor. When intermittent faults occur in cable circuits, the symptom of the problem often appears and disappears in milliseconds while the aftereffects can result in spurious alarms and automatic actuation of safety systems. Problems are compounded when component degradation causes a cable circuit to transmit inaccurate information that does not represent actual plant operating conditions. The root cause of intermittent cable circuit operation can include degradation of cable and connectors from heat, humidity, radiation, and vibration. Unlike hard faults (which are constant open or short circuits), intermittent faults are defined as a temporary change in impedance that may only last for a few milliseconds. While less disruptive than hard faults, signal spiking from intermittent faults can often lead to alarm conditions and reactor trips. A soft fault is defined as a subtle variation the electrical characteristics of the circuit that still permit the continued operation of the circuit. A soft fault may be a precursor to a hard fault due to continued degradation of the fault over time. The focus of this paper is the description of a cable testing system that can be connected to an active, low frequency circuit and continuously monitor electrical characteristics using the time domain reflectometry (TDR) technique until an intermittent impedance change occurs. This technique uses the difference in frequency response of the circuit and the TDR to isolate the TDR signature from the active circuit data . When a momentary impedance change occurs that exceeds a preconfigured limit threshold, the distance to fault data is automatically overlaid with the healthy baseline reference and stored in a database for diagnosis and repair. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

SVM-Based Synchronized Fault Detection for 100% Renewable Microgrids: Preprint

Traditional protection schemes face significant challenges when applied to microgrids with high penetrations of renewables with inverter-based resources (IBRs). The proliferation of advanced sensing and communication technologies has generated copious data, offering an opportunity to overcome these limitations using data-driven machine learning approaches. This work proposes a novel approach based on a support vector machine (SVM) for detecting faults within a 100% renewable microgrid. The approach encompasses a systematic offline training stage for the development of a linear SVM-based fault detection algorithm. This process covers offline data collection from the microgrid under study, the extraction of features such as positive- and negative-sequence components and the total harmonic distortion of the voltage and current measurements of the relays, and the design of the linear SVM-based classifier. During the online implementation, however, different classifiers can exhibit asynchronicity in detecting the fault inception at different subcycle-to-cycle period-level delays. To circumvent this asynchronicity issue, a separate algorithm is developed for each relay to estimate the fault inception time as close to the real fault time. The performance of the proposed SVM-based synchronized fault detection method is evaluated using online time-domain simulation studies on a microgrid test system. The results corroborate the reliability of the fault detection scheme when tested under various fault cases (fault types, locations, and impedances) and non-fault cases during both grid-tied and islanded operation modes.

100% microgrid↗

A Novel Protection Scheme for Unbalanced Faults in Inverter Dominated Networks: A Computationally Efficient Algorithm for Entry-Level Relays

Microgrids are now a common practice in distribution systems to increase resilience and reliability. However, microgrid protection remains a critical challenge, considering its requirement to operate in both grid connected and islanded, and the variability in fault characteristics under each mode of operation. This paper presents unbalanced power (S unb ) based fault detection algorithm, which considers local voltage and current unbalances to determine faults in the system. S unb is a computationally efficient fault detection algorithm that is suitable for implementation in the programmable logic of entry level protective relays. In addition, the difference in current and voltage unbalance (D n ) is used to determine the fault type. The proposed method demonstrates high sensitivity and selectivity for line-to-ground (LG), line-to-line (LL), and double line-to-ground (LLG) faults, representing the most common faults in distribution systems. It also allows relay coordination with upstream and downstream protection devices in both island and grid connected operation, while preserving grading margins. The same pickup and time multiplier settings of a particular relay for both modes of operation eliminates the need for adaptive settings, which rely on communication networks. Validation was performed with a hardware-in-the-loop (HIL) setup using Typhoon HIL real time simulator interfaced with three entry-level, SEL 751 relays. Results confirmed the algorithm’s ability to discriminate fault conditions, and determine the fault type under both operating modes, maintain fast detection times, and ensure proper protection coordination.

fault classification↗

A Hybrid DC Fault Primary Protection Algorithm for Multi-Terminal HVdc Systems

Protection against dc faults is one of the main technical hurdles faced when operating converter-based HVdc systems. Protection becomes even more challenging for multi-terminal dc (MTdc) systems with more than two terminals/converter stations. In this paper, a hybrid primary fault detection algorithm for MTdc systems is proposed to detect a broad range of failures. Sensor measurements, i.e., line currents and dc reactor voltages measured at local terminals, are first processed by a top-level context clustering algorithm. For each cluster, the best fault detector is selected among a detector pool according to a rule resulting from a learning algorithm. The detector pool consists of several existing detection algorithms, each performing differently across fault scenarios. The proposed hybrid primary detection algorithm: i) offers superior performance compared to an individual detector through a data-driven approach; ii) detects all major fault types including pole-to-pole (P2P), pole-to-ground (P2G), and external dc faults; iii) identifies faults with various fault locations and impedances; iv) is more robust to noisy sensor measurements compared to existing methods; v) does not require exhaustive simulation and sampling for training the model. Performance and effectiveness of the proposed algorithm are evaluated and verified based on time-domain simulations in the PSCAD/EMTDC software environment. The results confirm satisfactory operation, accuracy, and detection speed of the proposed algorithm under various fault scenarios.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An Engineered Minimal-Set Stimulus for Periodic Information Leakage Fault Detection on a RISC-V Microprocessor

Recent evaluations of counter-based periodic testing strategies for fault detection in Microprocessor (μP) have shown that only a small set of counters is needed to provide complete coverage of severe faults. Severe faults are defined as faults that leak sensitive information, e.g., an encryption key on the output of a serial port. Alternatively, fault detection can be accomplished by executing instructions that periodically test the control and functional units of the μP. In this paper, we propose a fault detection method that utilizes an ’engineered’ executable program combined with a small set of strategically placed counters in pursuit of a hardware Periodic Built-In-Self-Test (PBIST). We analyze two distinct methods for generating such a binary; the first uses an Automatic Test Generation Pattern (ATPG)-based methodology, and the second uses a process whereby existing counter-based node-monitoring infrastructure is utilized. We show that complete fault coverage of all leakage faults is possible using relatively small binaries with low latency to fault detection and by utilizing only a few strategically placed counters in the μP.

42 ENGINEERING↗

Pressure transient analysis during CO 2 push-pull tests into faults for EGS characterization

Here, with the goal of detecting and characterizing faults and fractures in enhanced geothermal systems (EGS), a new technology involving CO 2 push-pull testing, active-source geophysical imaging, and well logging has recently been proposed. This technique takes advantage of (1) the contrasting properties of supercritical CO 2 and water which cause CO 2 to appear distinct from surrounding brine in seismic and other geophysical logging approaches, (2) the non-wetting nature of CO 2 which keeps it localized to the faults and fractures to create contrast potentially sufficient for active seismic and well-logging approaches to image faults and fracture zones at EGS sites. In this study, we evaluate the feasibility of using pressure transient monitoring during CO 2 push-pull tests to complement active seismic and wireline well logging for EGS characterization. For this purpose, we developed a 2D model of a prototypical geothermal site (Desert Peak, NV) that includes a single fault. The fault zone consists of a slip plane, fault gouge, and damage zone, and is bounded by the surrounding matrix of the country rock. Through numerical simulation using iTOUGH2, we found that the pressure transient at the monitoring wells in the fault gouge shows unique traits due to the multiphase flow conditions developed by CO 2 injection, and varies sensitively on the arrival of the CO 2 plume and the degree of CO 2 saturation. A sensitivity analysis shows the pressure transient is most sensitive to the fault gouge permeability, but also depends on multiphase flow parameters and the boundary conditions of the fault. Lastly, an inversion study reveals that the fault gouge permeability can be best estimated with the pressure transient data, whereas additional CO 2 saturation data do not improve the accuracy of the inversion significantly.

58 GEOSCIENCES↗

Influence of Fault Architecture on Induced Earthquake Sequence Evolution Revealed by High-Resolution Focal Mechanism Solutions

The increasing seismicity and improved seismic observation network in recent years provide an opportunity to explore factors that influence the triggering processes, spatiotemporal evolution, and maximum magnitude of induced sequences. We map the fault architecture and stress state of four induced sequences in Oklahoma to determine their influence on the seismicity. We systematically relocate the earthquakes and compute hundreds of focal mechanisms of small to medium events (1.0 < M < 5.1) using various techniques, including machine learning, for the Guthrie, Woodward, Cushing, and Fairview sequences. The detailed fault geometry and spatiotemporal evolution of seismicity and stress states reveal different dominant driving forces for each sequence. In Cushing and Fairview (largest event ≥M5.0), the main fault structures are near-vertical narrow strike-slip faults, with most of the small earthquake fault planes optimally oriented. The two sequences exhibit discontinuous temporal migration but strong earthquake self-driven rupture growth. In Guthrie and Woodward (largest event <M5.0), the two sequences show more complex diffuse fault structures with varying dipping angles along depth. The inverted focal mechanisms show a mix of strike-slip faulting and normal faulting in both sequences, and the normal faulting events are less optimally oriented than strike-slip events. The two sequences are dominated by continuous diffusive migration in time driven by pore pressure propagation. The above results suggest that fault architecture and stress state influence sequence evolution, major driving forces, and possibly maximum magnitude.

58 GEOSCIENCES↗

Transient evolution of permeability and friction in a slowly slipping fault activated by fluid pressurization

The mechanisms of permeability and friction evolution in a natural fault are investigated in situ. During three fluid injection experiments at different places in a fault zone, we measured simultaneously the fluid pressure, fault displacements and seismic activity. Changes in fault permeability and friction are then estimated concurrently. Results show that fault permeability increases up to 1.58 order of magnitude as a result of reducing effective normal stress and cumulative dilatant slip, and 19-to-60.8% of the enhancement occurs without seismic emissions. When modeling the fault displacement, we found that a rate-and-state friction and a permeability dependent on both slip and slip velocity together reasonably fit the fault-parallel and fault-normal displacements. This leads to the conclusion that the transient evolution of fault permeability and friction caused by a pressure perturbation exerts a potentially dominant control on fault stability during fluid flow.

58 GEOSCIENCES↗

The effect of shear strain and shear localization on fault healing

The seismic cycle of repeated earthquake failure requires that faults regain frictional strength during the interseismic phase, when the fault is locked or undergoing quasi-static creep. Fault healing plays a central role in determining earthquake stress drop, recurrence interval, elastic radiation frequency and other source parameters. In particular, the longer a fault remains quasi-stationary, the stronger it becomes and the larger the potential stress drop can be for the next event. Here, we address the role of shear strain and strain localization on fault healing and healing rate. We performed slide-hold-slide friction experiments on quartz gouge in the double-direct shear configuration for shear strain up to 25 and hold times from 10 to 1000 s. The results show that both healing and healing rate increase nonlinearly with increasing shear strain. Frictional healing scales with volumetric strain within the laboratory fault zone. Using the volumetric strain upon reshear as a proxy for strain localization, we demonstrate that the capacity of a fault to heal is directly proportional to shear bandwidth and degree of strain localization. The more the deformation is localized, the higher are the healing and healing rate, and thus, the fault strength. Our data provide a framework for understanding variations in fault strength over the seismic cycle and the role of brecciation and strain localization on spatiotemporal variations in fault strength.

58 GEOSCIENCES↗

Deep-learning-based domain adaptation for cavity fault prediction at Jefferson Laboratory

Superconducting radio-frequency (SRF) cavities are the core components of the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab, providing high-power electron beams for nuclear physics experiments. The facility comprises 418 SRF cavities, and any fault in these cavities can lead to interruptions in the electron beam supply. Cavity faults are the leading cause of beam trips in CEBAF. Predicting and mitigating those faults before onset can help maintain normal operation. Existing models face challenges in distinguishing between normal and fault signals when changes occur in the underlying time-series data, from changes in control software, operational parameters, or the environment. This work proposes a deep learning domain adaptation model that leverages transfer learning to address fault prediction challenges by improving accuracy. The model is trained and fine-tuned using a dataset collected for faulty and normal operation using a data acquisition system in CEBAF. Our deep learning-based domain adaptation model achieves a prediction accuracy of 89.61% of the fault and normal signals. The developed model effectively predicts normal running signals compared to the baseline approach without domain adaptation. This capacity is essential for the fault prediction task in the CEBAF because of heavily imbalanced data containing vast amounts of normal signals. The model performs well for predicting faults several hundred milliseconds before the fault onset compared to other models where no adaptation is applied. Incorporating deep learning-based domain adaptation techniques will significantly improve the fault prediction performance.

Rahman, Md Monibor [Old Dominion Univ., Norfolk, V↗

Partial differential equations preconditioner resilient to soft and hard faults

We present a domain-decomposition-based preconditioner for the solution of partial differential equations (PDEs) that is resilient to both soft and hard faults. The algorithm reformulates the PDE as a sampling problem, followed by a solution update through data manipulation that is resilient to both soft and hard faults. This reformulation allows us to recast the problem as a set of independent tasks, and exploit data locality to reduce global communication. We discuss two different parallel implementations: (a) a single program multiple data (SPMD) version based on a one-to-one mapping between subdomain and MPI processes responsible for both state and computation; and (b) an asynchronous server–client implementation where all state information is held by the servers and clients are designed solely as computational units. We present a scalability comparison of both implementations under nominal conditions, showing efficiency within ~80% for up to 12,000 cores. We present a resilience analysis under different fault scenarios based on the server–client implementation. This framework provides resiliency to hard faults such that if a client crashes, it stops asking for work, and the servers simply distribute the work among all of the other clients alive. Erroneous subdomain solves (e.g. due to soft faults) appear as corrupted data, which is either rejected if that causes a task to fail, or is seamlessly filtered out during the regression stage through a suitable noise model. Three different types of faults are modeled: hard faults modeling nodes (or clients) crashing; soft faults occurring during the communication of the tasks between server and clients; and soft faults occurring during task execution. We demonstrate the resiliency of the approach for a 2D elliptic PDE, and explore the effect of the faults at various failure rates.

97 MATHEMATICS AND COMPUTING↗

Evidence of a major fault zone along the California-Nevada state line 35 deg 30 min to 36 deg 30 min north latitude

The author has identified the following significant results. Geologic reconnaissance guided by analysis of ERTS-1 and Apollo-9 satellite imagery and intermediate scale photography from X-15 and U-2 aircraft has confirmed the presence of a major fault zone along the California-Nevada state line, between 35 deg 30 min and 36 deg 30 min north latitude. The name Pahrump Fault Zone has been suggested for this feature after the valley in which it is best exposed. Field reconnaissance has indicated the existence of previously unreported faults cutting bedrock along range fronts, and displacing Tertiary and Quaternary basin sediments. Gravity data support the interpretation of regional structural discontinuity along this zone. Individual fault traces within the Pahrump Fault Zone form generally left-stepping en echelon patterns. These fault patterns, the apparent offset of a Laramide age thrust fault, and possible drag folding along a major fault break suggest a component of right lateral displacement. The trend and postulated movement of the Pahrump Fault Zone are similar to the adjacent Las Vegas Shear Zone and Death Valley-Furnace Creek Faults, which are parts of a regional strike slip system in the southern Basin-Range Province.

Liggett, M. A.↗

Methodology for measurement of fault latency in a digital avionic miniprocessor

Using a gate level emulation of a typical avionics miniprocessor, fault injection experiments were performed to (1) determine the time to detect a fault by comparison monitoring, (2) forecast a program's ability to detect faults and (3) validate the fault detection coverage of a typical self test program. To estimate time to detect, six programs ranging in complexity from 6 to 147 instructions, were emulated. Each program was executed repetitively in the presence of a single stuck at fault at a gate node or device pin. Detection was assumed to occur whenever the computed outputs differed from the corresponding outputs of the same program executed in a nonfaulted processor. Histograms of faults detected versus number of repetitions to detection were tabulated. Using a simple model of fault detection, which was based in an analog with the selection of balls in an urn, distributions of time to detect were computed and compared with those obtained empirically. A self test program of 2,000 executable instructions was designed expressly for the study. The only requirement imposed on the design was that it should achieve 95% coverage. The program was executed in the presence of a single stuck-at fault at a gate node on device pin. The proportion of detected faults are tabulated. In all experiments faults were selected at random over gate nodes or device pins.

Mcgough, J. C.↗

Low-angle normal faults-low differential stress at mid crustal levels

A simple model for frictional slip on pre-existing faults that considers the local stress state near the fault and the effect of non-hydrostatic fluid pressures predicts that low-angle normal faulting is restricted to areas of the crust characterized by low differential stress and nearly lithostatic fluid pressures. The model considers frictional slip on a cohesionless low-angle normal fault governed by the failure criterion tau = mu sub f (sigma (*) sub n) =mu sub f (sigma sub n - P sub f) where tau and sigma sub n are the shear and normal stresses across the fault plane, mu sub f is the static coefficient of friction, and P sub f is the pore fluid pressure. As a first approximation, the model considers a vertical greatest principal compressive stress, sigma sub 1. It is apparent that if slip on low-angle normal faults is governed by the avove frictional failure criterion, slip on the low-angle normal fault occurs only if the least effective principal stress, sigma (*) sub 3 = sigma sub 3 - P sub f, is tensile, whenever tan superscrip -1(mu sub f d, where d is the dip of the fault. If detachment faulting occurs at any significant depth in the crust, P sub f sigma sub 3 is required. In light of this conclusion I allow P sub f to vary as necessary to allow slip on the low-angle normal fault.

Power, W. L.↗

Fault latency in the memory - An experimental study on VAX 11/780

Fault latency is the time between the physical occurrence of a fault and its corruption of data, causing an error. The measure of this time is difficult to obtain because the time of occurrence of a fault and the exact moment of generation of an error are not known. This paper describes an experiment to accurately study the fault latency in the memory subsystem. The experiment employs real memory data from a VAX 11/780 at the University of Illinois. Fault latency distributions are generated for s-a-0 and s-a-1 permanent fault models. Results show that the mean fault latency of a s-a-0 fault is nearly 5 times that of the s-a-1 fault. Large variations in fault latency are found for different regions in memory. An analysis of a variance model to quantify the relative influence of various workload measures on the evaluated latency is also given.

Chillarege, Ram↗