Determining Energies and Cross Sections of Individual Ions Using Higher-Order Harmonics in Fourier Transform Charge Detection Mass Spectrometry (FT-CDMS)

A general method for in situ measurements of the energy of individual ions trapped and weighed using charge detection mass spectrometry (CDMS) is described. Highly charged (> 300 e), individual polyethylene glycol (PEG) ions are trapped and oscillate within an electrostatic trap, producing a time domain signal. A segmented Fourier transform (FT) of this signal yields the temporal evolution of the fundamental and harmonic frequencies of ion motion throughout the 500-ms trap time. The ratio of the fundamental frequency and second harmonic (HAR) depends on the ion energy, which is an essential parameter for measuring ion mass in CDMS. This relationship is calibrated using simulated ion signals, and the calibration is compared to the HAR values measured for PEG ion signals where the ion energy was also determined using an independent method that requires that the ions be highly charged (> 300 e). The mean error of 0.6% between the two measurements indicates that the HAR method is an accurate means of ion energy determination that does not depend on ion size or charge. The HAR is determined dynamically over the entire trapping period, making it possible to observe the change in ion energy that takes place as solvent evaporates from the ion and collisions with background gas occur. This method makes it possible to measure mass changes, either from solvent evaporation or from molecular fragmentation (MS{sup n}), as well as the cross sections of ions measured using CDMS. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cosmology Intertwined III: $f \sigma_8$ and $S_8$

The standard $\Lambda$ Cold Dark Matter cosmological model provides a wonderful fit to current cosmological data, but a few tensions and anomalies became statistically significant with the latest data analyses. While these anomalies could be due to the presence of systematic errors in the experiments, they could also indicate the need for new physics beyond the standard model. In this Letter of Interest we focus on the tension of the Planck data with weak lensing measurements and redshift surveys, about the value of the matter energy density $\Omega_m$, and the amplitude or rate of the growth of structure ($\sigma_8,f\sigma_8$). We list a few interesting models for solving this tension, and we discuss the importance of trying to fit with a single model a full array of data and not just one parameter at a time.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Statistical change detection of building energy consumption: Applications to savings estimation

The surge in interval meter data availability and associated activity in energy data analytics has inspired new interest in advanced methods for building efficiency savings estimation. Statistical and machine learning approaches are being explored to improve the energy baseline models used to measure and verify savings. One outstanding challenge is the ability to identify and account for operational changes that may confound savings estimates. In the measurement and verification (M&V) context, ‘non-routine events’ (NREs) cause changes in building energy use that are not attributable to installed efficiency measures, and not accounted for in the baseline model’s independent variables. In the M&V process NREs must be accounted for as ‘adjustments’ to appropriately attribute the estimated energy savings to the specific efficiency interventions that were implemented. Currently this is a manual and custom process, conducted using professional judgment and engineering expertise. As such it remains a barrier in scaling and standardizing meter-based savings estimation. Here in this work, a data driven methodology was developed to (partially) automate, and therefore streamline the process of detecting NREs in the post-retrofit period and making associated savings adjustments. The proposed NRE detection algorithm is based on a statistical change point detection method and a dissimilarity metric. The dissimilarity metric measures the proximity between the actual time series of the post-retrofit energy consumption and the projected baseline, which is generated using a statistical baseline model. The suggested approach for NRE adjustment involves the NRE detection algorithm, the M&V practitioner, and a regression modeling algorithm. The performance of the detection and adjustment algorithm was evaluated using a simulation-generated test data set, and two benchmark algorithms. Results show a high true positive detection rate (75%-100% across the test cases), higher than ideal false positive detection rates (20%-70%), and low errors in energy adjustment (<0.7%). These results indicate that the algorithm holds for helping M&V practitioners to streamline the process of handling NREs. Moreover, the change point algorithm and underlying statistical principles could prove valuable for other building analytics applications such as anomaly detection and fault diagnostics.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Air compressor load forecasting using artificial neural network

Air compressor systems are responsible for approximately 10% of the electricity consumed in United States and European Union industry. As many researches have proven the effectiveness of using Artificial Neural Network inair compressor performance prediction, there is still a need to forecast the air compressor electrical load profile. The objective of this study is to predict compressed air systems’ electrical load profile, which is valuable to industry practitioners as well as software providers in developing better practice and tools for load managementand look-ahead scheduling programs. Two artificial neural networks, Two-Layer Feed-Forward Neural Networkand Long Short-Term Memory were used to predict an air compressors electrical load. Compressors with three different control mechanisms are evaluated with a total number of 11,874 observations. Here, the forecasts were validated using out-of-sample datasets with 5-fold cross-validation. Models produced average coefficient ofdetermination values from 0.24 to 0.94, average root-mean-square errors from 0.05 kW - 5.83 kW, and meanabsolute scaled errors from 0.20 to 1.33. The results indicate that both artificial neural networks yield goodresults for compressors using variable speed drive (average R 2 = 0.8 and no naïve forecasting), only the longshort-term memory model gives acceptable results for compressors using on/off control (average R 2 = 0.82 and no naïve forecasting), and no satisfactory results are obtained for load/unload type air compressors (models constituting active forecasting).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A dataset of recorded electricity outages by United States county 2014–2022

In this Data Descriptor, we present county-level electricity outage estimates at 15-minute intervals from 2014 to 2022. By 2022 92% of customers in the 50 US States, Washington DC, and Puerto Rico are represented. These data have been produced by the Environment for Analysis of Geo-Located Energy Information (EAGLE-I TM ), a geographic information system and data visualization platform created at Oak Ridge National Laboratory to map the population experiencing electricity outages every 15 minutes at the county level. Although these data do not cover every US customer, they represent the most comprehensive outage information ever compiled for the United States. The rate of coverage increases through time between 2014 and 2022. We present a quantitative Data Quality Index for these data for the years 2018–2022 to demonstrate temporal changes in customer coverage rates by FEMA region and indicators of data collection gaps or other errors.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Stochastic growth logistic model with aftereffect for batch fermentation process

In this paper, the stochastic growth logistic model with aftereffect for the cell growth of C. acetobutylicum P262 and Luedeking-Piret equations for solvent production in batch fermentation system is introduced. The parameters values of the mathematical models are estimated via Levenberg-Marquardt optimization method of non-linear least squares. We apply Milstein scheme for solving the stochastic models numerically. The effciency of mathematical models is measured by comparing the simulated result and the experimental data of the microbial growth and solvent production in batch system. Low values of Root Mean-Square Error (RMSE) of stochastic models with aftereffect indicate good fits.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Accurate prediction of global-density-dependent range-separation parameters based on machine learning

In this work, we develop an accurate and efficient XGBoost machine learning model for predicting the global-density-dependent range-separation parameter, ωGDD, for long-range corrected functional (LRC)-ωPBE. This ωGDDML model has been built using a wide range of systems (11 466 complexes, ten different elements, and up to 139 heavy atoms) with fingerprints for the local atomic environment and histograms of distances for the long-range atomic correlation for mapping the quantum mechanical range-separation values. The promising performance on the testing set with 7046 complexes shows a mean absolute error of 0.001 117 a0−1 and only five systems (0.07%) with an absolute error larger than 0.01 a0−1, which indicates the good transferability of our ωGDDML model. In addition, the only required input to obtain ωGDDML is the Cartesian coordinates without electronic structure calculations, thereby enabling rapid predictions. LRC-ωPBE(ωGDDML) is used to predict polarizabilities for a series of oligomers, where polarizabilities are sensitive to the asymptotic density decay and are crucial in a variety of applications, including the calculations of dispersion corrections and refractive index, and surpasses the performance of all other popular density functionals except for the non-tuned LRC-ωPBE. Finally, LRC-ωPBE (ωGDDML) combined with (extended) symmetry-adapted perturbation theory is used in calculating noncovalent interactions to further show that the traditional ab initio system-specific tuning procedure can be bypassed. The present study not only provides an accurate and efficient way to determine the range-separation parameter for LRC-ωPBE but also shows the synergistic benefits of fusing the power of physically inspired density functional LRC-ωPBE and the data-driven ωGDDML model.

Chemistry↗

Achieving accurate energetics beyond (semi-)local density functional theory: Illustrated with transition metal disulfides, Cu 2 ZnSnS 4 , and Na 3 PS 4 related semiconductors

Understanding, designing, and processing functional metal sulfides are significant challenges partially because of the high temperatures and pressures and the number of secondary phases encountered in these complex systems. In particular, the underlying thermochemical properties are not well understood that would allow prediction of equilibrium conditions and driving forces. In addition, obtaining accurate values for the energetics of metal sulfide systems is far from complete, suggesting application of density functional theory (DFT) calculations. Here, the results of an examination of 69 phases by DFT using 12 exchange-correlation (X-C) functionals indicate that (i) the key source of error in predicting the Gibbs energy of a phase is the enthalpy calculated at 0 K rather than entropy at finite temperatures from phonon calculations and (ii) an improved prediction of the thermodynamic properties at 0 K relies on the selected nonlocal X-C functional such as the hybrid potential. Regarding metal sulfides, we conclude from the present DFT results that (1) the secondary phase Cu 2 ZnSn 3 S 8 , associated with the desired photovoltaic material Cu 2 ZnSnS 4 , is not stable at 0 K, but it becomes slightly stable with increasing temperature (i.e., >800 K), primarily due to the vibrational entropy, which makes it difficult to be detected in a typical thin-film growth process; (2) the hybrid X-C functional improves the predicted energetics for most of the layered transition-metal disulfides such as TiS 2 , MoS 2 , and WS 2 , but not for the nonlayered RuS 2 , OsS 2 , and IrS 2 as well as the layered PdS 2 ; and (3) the formation of the solid-state electrolyte Na3PS4 is thermodynamically favored. We further conclude that accurate energetics as a function of temperature for the materials of interest is feasible to be achieved beyond the semilocal DFT calculations with the key being enthalpy predicted at 0 K.

36 MATERIALS SCIENCE↗

Performance-based assessment of reconstructed images

During the early 90s, I engaged in a productive and enjoyable collaboration with Robert Wagner and his colleague, Kyle Myers. We explored the ramifications of the principle that tbe quality of an image should be assessed on the basis of how well it facilitates the performance of appropriate visual tasks. We applied this principle to algorithms used to reconstruct scenes from incomplete and/or noisy projection data. For binary visual tasks, we used both the conventional disk detection and a new challenging task, inspired by the Rayleigh resolution criterion, of deciding whether an object was a blurred version of two dots or a bar. The results of human and machine observer tests were summarized with the detectability index based on the area under the ROC curve. We investigated a variety of reconstruction algorithms, including ART, with and without a nonnegativity constraint, and the MEMSYS3 algorithm. We concluded that the performance of the Raleigh task was optimized when the strength of the prior was near MEMSYS's default 'classic' value for both human and machine observers. A notable result was that the most-often-used metric of rms error in the reconstruction was not necessarily indicative of the value of a reconstructed image for the purpose of performing visual tasks.

99 GENERAL AND MISCELLANEOUS↗

Validation of CT dose-reduction simulation

The objective of this research was to develop and validate a custom computed tomography dose-reduction simulation technique for producing images that have an appearance consistent with the same scan performed at a lower mAs (with fixed kVp, rotation time, and collimation). Synthetic noise is added to projection (sinogram) data, incorporating a stochastic noise model that includes energy-integrating detectors, tube-current modulation, bowtie beam filtering, and electronic system noise. Experimental methods were developed to determine the parameters required for each component of the noise model. As a validation, the outputs of the simulations were compared to measurements with cadavers in the image domain and with phantoms in both the sinogram and image domain, using an unbiased root-mean-square relative error metric to quantify agreement in noise processes. Four-alternative forced-choice (4AFC) observer studies were conducted to confirm the realistic appearance of simulated noise, and the effects of various system model components on visual noise were studied. The ''just noticeable difference (JND)'' in noise levels was analyzed to determine the sensitivity of observers to changes in noise level. Individual detector measurements were shown to be normally distributed (p>0.54), justifying the use of a Gaussian random noise generator for simulations. Phantom tests showed the ability to match original and simulated noise variance in the sinogram domain to within 5.6%{+-}1.6% (standard deviation), which was then propagated into the image domain with errors less than 4.1%{+-}1.6%. Cadaver measurements indicated that image noise was matched to within 2.6%{+-}2.0%. More importantly, the 4AFC observer studies indicated that the simulated images were realistic, i.e., no detectable difference between simulated and original images (p=0.86) was observed. JND studies indicated that observers' sensitivity to change in noise levels corresponded to a 25% difference in dose, which is far larger than the noise accuracy achieved by simulation. In summary, the dose-reduction simulation tool demonstrated excellent accuracy in providing realistic images. The methodology promises to be a useful tool for researchers and radiologists to explore dose reduction protocols in an effort to produce diagnostic images with radiation dose ''as low as reasonably achievable.''.

61 RADIATION PROTECTION AND DOSIMETRY↗

Performance of a high-sensitivity dedicated cardiac SPECT scanner for striatal uptake quantification in the brain based on analysis of projection data

Purpose: The authors have previously reported the advantages of high-sensitivity single-photon emission computed tomography (SPECT) systems for imaging structures located deep inside the brain. DaTscan (Isoflupane I-123) is a dopamine transporter (DaT) imaging agent that has shown potential for early detection of Parkinson disease (PD), as well as for monitoring progression of the disease. Realizing the full potential of DaTscan requires efficient estimation of striatal uptake from SPECT images. They have evaluated two SPECT systems, a conventional dual-head gamma camera with low-energy high-resolution collimators (conventional) and a dedicated high-sensitivity multidetector cardiac imaging system (dedicated) for imaging tasks related to PD. Methods: Cramer-Rao bounds (CRB) on precision of estimates of striatal and background activity concentrations were calculated from high-count, separate acquisitions of the compartments (right striata, left striata, background) of a striatal phantom. CRB on striatal and background activity concentration were calculated from essentially noise-free projection datasets, synthesized by scaling and summing the compartment projection datasets, for a range of total detected counts. They also calculated variances of estimates of specific-to-nonspecific binding ratios (BR) and asymmetry indices from these values using propagation of error analysis, as well as the precision of measuring changes in BR on the order of the average annual decline in early PD. Results: Under typical clinical conditions, the conventional camera detected 2 M counts while the dedicated camera detected 12 M counts. Assuming a normal BR of 5, the standard deviation of BR estimates was 0.042 and 0.021 for the conventional and dedicated system, respectively. For an 8% decrease to BR = 4.6, the signal-to-noise ratio were 6.8 (conventional) and 13.3 (dedicated); for a 5% decrease, they were 4.2 (conventional) and 8.3 (dedicated). Conclusions: This implies that PD can be detected earlier with the dedicated system than with the conventional system; therefore, earlier identification of PD progression should be possible with the high-sensitivity dedicated SPECT camera.

60 APPLIED LIFE SCIENCES↗

SU-C-204-03: In-Vivo Range Verification and Tissue Response to Proton Radiotherapy Using Prompt Gamma Volume Histograms

Purpose: To study if prompt gamma (PG) volume histograms created from PG images acquired during treatment delivery can be used to identify changes to beam range and tissue composition in response to proton radiotherapy. Methods: Monte Carlo simulations of a single field from a single treatment fraction (100 cGy) for prostate cancer were performed for the cases of: 1) an ideal patient setup, 1) a setup shift in the superior direction and 2) a reduction in oxygen concentration in the tumor. For each case, the 3 -Dimsional dose delivery and elemental PG emission in the patient for the treatment fraction were recorded and imported into a commercial treatment planning system. Changes in the dose volume histograms (DVH), as well as the PG volume histograms (PG-VH) for the PG emission from oxygen and for the total PG emission (from all elements) were analyzed. Results: For the 1 cm superior shift, the prostate DVH and total PG-VH both shifted toward lower doses with the shape of the curves remaining nearly unchanged, resulting in the DVH V95 dropping from 100 cGy to 90 cGy. For the total PG-VH, the V95 fell from 50 to 38. For the reduced oxygen case, both the DVH and PG-VH had a much different shape than for the ideal case, with a significant downward slope in the curves as a function of dose. Conclusions: The shift in the prostate PG-VH for a superior shift in the patient setup correlated well with the DVH indicating it is possible to detect setup errors by analyzing the PG-VH from prompt gamma images obtained during daily proton treatment delivery. Additionally, it may be possible to detect changes in the elemental concentrations of irradiated tissues by analyzing the shape of the PG-VH.

60 APPLIED LIFE SCIENCES↗

Moment Tensor Source-Type Analysis for the Democratic People's Republic of Korea-Declared Nuclear Explosions (2006-2017) and 3 September 2017 Collapse Event

The Democratic People's Republic of Korea (DPRK) conducted its sixth announced nuclear test on 3 September 2017 03:30 UTC (mb 6.1). There was an aftershock 8.5 min later (mb 4.1). Such aftershocks were noteworthy and often associated with post–nuclear explosion collapses. We performed moment tensor (MT) and network sensitivity solution (NSS) analysis using regional long-period surface-wave and first-motion (FM) polarities. We also extended this analysis to the previous five DPRK nuclear tests. The NSS results, which include MT solution uncertainties, show large isotropic components for the events and are within the population of other U.S. nuclear and collapse events on the fundamental lune. The FM data improved the NNS source-type resolution. The agreement between MT seismic moments and independent coda-envelope amplitudes indicated no biases with the Earth model error or poorly constrained seismic moment for shallow seismic sources. The MT for the collapse is not a pure implosion and consistent with an equivalent tensional closing crack mechanism and two-sided vertical point force.

58 GEOSCIENCES↗

Multifamily Envelope Leakage Model

The objective of the 2013 research project was to develop the model for predicting fully guarded test results (FGT), using unguarded test data and specific building features of apartment units. The model developed has a coefficient of determination R2 value of 0.53 with a root mean square error (RMSE) of 0.13. Both statistical metrics indicate that the model is relatively strong. When tested against data that was not included in the development of the model, prediction accuracy was within 19%, which is reasonable given that seasonal differences in blower door measurements can vary by as much as 25%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A convergence analysis of stochastic collocation method for Navier-Stokes equations with random input data

Stochastic collocation method has proved to be an efficient method and been widely applied to solve various partial differential equations with random input data, including Navier- Stokes equations. However, up to now, rigorous convergence analyses are limited to linear elliptic and parabolic equations; its performance for Navier-Stokes equations was demonstrated mostly by numerical experiments. In this paper, we provide an error analysis of stochastic collocation method for a semi-implicit Backward Euler discretization for NSE and prove the exponential decay of the interpolation error in the probability space. Our analysis indicates that due to the nonlinearity, as final time T increases and NSE solvers pile up, the accuracy may be reduced significantly. Subsequently, the theoretical results are illustrated by the numerical test of time dependent fluid flow around a bluff body.

97 MATHEMATICS AND COMPUTING↗

Building America Case Study: Predicting Envelope Leakage in Attached Dwellings (Fact Sheet)

'The cost for blower testing is high, because it is labor intensive, and it may disrupt occupants in multiple units. This high cost and disruption deters program participants, and dissuades them from pursuing energy improvements that would trigger air leakage testing, such as improvements to the building envelope.' This statement found in a 2012 report by Heschong Mahone Group emphasizes the importance of reducing the cost and complexity of blower testing in multifamily buildings. Energy efficiency opportunities are being bypassed. The cost of single blower testing is on the order of $300. The cost for guarded blower door testing, the more appropriate test for assessing energy savings opportunities, could easily be six times that and that's only if you have the equipment and simultaneous access to multiple apartments. Thus, the proper test is simply not performed. The objective of the 2013 research project was to develop the model for predicting fully guarded test results (FGT), using unguarded test data and specific building features of apartment units. The model developed has a coefficient of determination R2 value of 0.53 with a root mean square error (RMSE) of 0.13. Both statistical metrics indicate that the model is relatively strong. When tested against data that was not included in the development of the model, prediction accuracy was within 19%, which is reasonable given that seasonal differences in blower door measurements can vary by as much as 25%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Autoencoder-Based Optical Wireless Communications Systems

In this study, we propose deep neural network autoencoders for capturing the end-to-end performance of the single- and multi-user optical wireless communications (OWC) systems. We compare the end-toend performance of the proposed autoencoders (learningbased OWC systems) with the state-of-the art model-based OWC systems in terms of the block error rate (BLER) metric. Our numerical results indicate that the proposed learning-based OWC system outperforms the model-based counterparts in both single- and multi-user settings.

99 GENERAL AND MISCELLANEOUS↗

Selection of Training Sets for 235U Source Detection Classifiers Using Gamma Signatures

The machine learning methods for classifiers to detect low level radiation sources are of interest when suitable training data sets are available. Their application and performance assessment, however, involves the aspects of over-fitting and training data selection that are somewhat uncommon in other existing methods for this task.We study U-235 gamma signatures using data sets collected by 21 NaI detectors under controlled conditions. The gamma spectra are collected by the detectors located at different distances from the source, and we study their choice as training sets for classifiers to detect a source. The detectors form the near, middle and outer groups based on the distance to source. The classifiers based on the outer group are susceptible to over-fitting, that is, they achieve low training error but incur much higher testing error in independent tests. The other two groups achieve lower training error and comparable testing error, and the near group achieves the overall lowest error. In detecting a source at an unknown distance, the farther detectors in the middle group achieve the overall lowest testing error with limited over-fitting, thereby indicating the complex dependencies between the training and classifier performance.

Rao, Nageswara↗