Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electronic filters”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Solar particle tracks in glass from Surveyor 3

Samples of glass from the Surveyor 3 TV camera filter were examined for particle tracks by optical and scanning electron microscopy. The corrected density value is 1.7 million + or - 0.1 million tracks/sq cm, and the track density vs depth curve is determined. Comparisons with other estimated and calculated data are discussed, and lack of agreement between data sets is considered. It is felt that considerable erosion occurs, and that erosion also occurs by a flaking of small thicknesses of material, possibly caused by solar wind irradiation.

Crozaz, G.↗

Electron beam fluorescence system to measure gas density in impulse facilities

Very rapid measurements, ranging from a few microsecond to milliseconds in duration, characterize studies made in shock regions or behind them. A system to measure gas density under such conditions in a 15.24-cm (6-in.) expansion tube is described. The basic elements are an electron beam of moderate energy and high current capability, an optical detector, and the associated electronics and data readout equipment. A heated-cathode electron gun, capable of pulsed operation and delivering up to 200 milliamperes current, provides the source of electrons. Optics include a simple collector lens, aperture, collimator lens, filters, and a photomultiplier tube. The photomultiplier output signal was recorded by means of photographed oscilloscope traces for pulsed beam operation.

Hoppe, J. C.↗

Filamentary current structures in the postnoon sector: Observations from UARS

During an intense geomagentic storm (Kp 7+) that began at approximately 1830 UT on October 1, 1991, the Upper Atmosphere Research Satellite (UARS) satellite encountered the dayside postnoon auroral oval. On two consecutive crossings of the northern hemisphere between 2040 and 2240 UT, the vector magnetometer detected region 1 and 2 Birkeland and ionospheric currents in the postnoon sector. Low-energy electron events were observed near 1400 MLT within a narrow portion of the region 1 current system. Simultaneous magnetic field measurements revealed the presence of intense (approximately 20 microA/sq m) bipolar filament current structures embedded in the auroral oval. The upward-directed currents were associated with the more concentrated region of precipitating electrons. Ions associated with the more intense flux of low-energy electrons exhibited a dispersion signature typical of an ion velocity filter. The dispersion, aligned along the orbit, exhibited higher-energy ions at lower latitudes and earlier local times. The colocation of filament currents and ion dispersion signatures at such late postnoon local times is not consistent with typical E x B 'cusp' dispersions. These features more likely result from dayside boundary wave phenomena.

Bythrow, P. F.↗

Spectrally filtered ps–ns emission dynamics of atmospheric-pressure nanosecond pulsed plasmas

The temporal dynamics of atmospheric-pressure nanosecond pulsed plasma discharges in a pin-to-pin electrode configuration are studied using streak-camera line imaging of the interelectrode gap with a time resolution as short as ~25 ps. Discharge emission initiates homogeneously throughout the interelectrode gap with no detectable streamer propagation and then temporally decays in two distinct phases. Plasma emission bands attributed to various electronic transitions are tracked for single discharges in air and N 2 . Spectral filtering of the excited molecular states reveals that the N 2 (C–B) and N 2 (B–A) emission bands evolve in distinct early and late phases, respectively, with a time separation of ~15–20 ns. Furthermore, significant differences in the temporal dynamics of plasma discharges in air and N2 are observed. High levels of excited-state atomic oxygen and NO appear after the initial decay of the N 2 (C) state and coincide primarily with the latter phases of plasma evolution in air environments. From temporal traces of discharge emission, the formation and relaxation timescales of the electronically excited states of N 2 are quantified in pure N2 and air environments with sub-nanosecond resolution. The streak-OES (optical emission spectroscopy) technique enables quantitative time-resolved studies of key chemical species for model validation in ultra-short-pulsed plasmas.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Mesospheric KHI signatures in reconstructed broadband rocket probe data

In an accepted method of measuring D region electron density with a rocket-borne dc-mode Langmuir probe, the resulting fine-structure signal is modified by a high-pass filter. While this form of data has been successfully used for power spectral analysis, it fails to reveal important spatial domain features without further processing. It is demonstrated that the broadband signal can be recovered by use of a digital filter that corrects for the on-board high-pass filter effects. The D-region broadband structure so recovered for a daytime equatorial flight shows variations in electron density consistent with a model of Kelvin-Helmholtz billows, and not consistent with inertial range turbulence. The isolated regions of irregularity are about 100 m thick near an altitude of 75 km, imbedded in a region with a staircase-structure electron density profile with about 200-m steps. Suggestive similarities to a numerical model of KHI are to undersea observations of KHI-caused microstructure are shown.

Parker, Jay W.↗

Carbon Nanotubes/Nanofibers by Plasma Enhanced Chemical Vapour Deposition

Plasma enhanced chemical vapour deposition (PECVD) has been recently used for the production of vertically aligned carbon nanotubedfibers (CN) directly on substrates. These structures are potentially important technologically as electron field emitters (e.g. microguns, microwave amplifiers, displays), nanoelectrodes for sensors, filter media, superhydrophobic surfaces and thermal interface materials for microelectronics. A parametric study on the growth of CN grown by glow discharge dc-PECVD is presented. In this technique, a substrate containing thin film Ni catalyst is exposed to C2H2 and NH3 gases at 700 C. Without plasma, this process is essentially thermal CVD which produces curly spaghetti-like CN as seen in Fig. 1 (a). With the plasma generated by biasing the substrate at -6OOV, we observed that the CN align vertically during growth as shown in Fig. l(b), and that the magnitude of the applied substrate bias affects the degree of alignment. The thickness of the thin film Ni catalyst was found to determine the average diameter and inversely the length of the CN. The yield and density of the CN were controlled by the use of different diffusion barrier materials under the Ni catalyst. Patterned CN growth [Fig. l(c)], with la variation in CN diameter of 4.1% and 6.3% respectively, is achieved by lithographically defining the Ni thin film prior to growth. The shape of the structures could be varied from very straight nanotube-like to conical tip-like nanofibers by increasing the ratio of C2H2 in the gas flow. Due to the plasma decomposition of C2H2, amorphous carbon (a-C) is an undesirable byproduct which could coat the substrate during CN growth. Using a combination of depth profiled Auger electron spectroscopy to study the substrate and in-situ mass spectroscopy to examine gas phase neutrals and ions, the optimal conditions for a-C free growth of CN is determined.

Teo, K. B. K.↗

Intelligent, grid-friendly, modular extreme fast charging system with solid-state DC protection

The development of electric vehicle (EV) charging infrastructure is crucial for the widespread adoption of electric transportation. However, implementing such infrastructure is a complex task that requires consideration of factors such as space limitations, adherence to industry standards, grid capacity, and other technical and policy issues. This project seeks to create a framework for the efficient design of compact medium voltage (MV) extreme fast charging (XFC) stations for EVs. The station design involves the use of a solid-state transformer (SST) that connects to the MV distribution network, delivering power to a shared DC bus. This innovative approach eliminates the need for a step-down transformer to provide low-voltage service by connecting directly to the MV distribution network. Eliminating the low-frequency transformer not only reduces the system footprint and losses but also eliminates inrush currents during grid black-start. Additionally, placing power electronics directly on the distribution system allows for high-bandwidth filtering and power factor correction. The inclusion of a shared DC bus enables multiple charging dispensers and DC storage/generation units to connect, forming a DC microgrid. This setup facilitates power sharing with minimal conversion stages. The project showcases a DC distribution network protected by intelligent solid-state (SS) DC circuit breakers (DCCB) capable of isolating the smallest section of the faulted circuit much faster than existing mechanical solutions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Observations of supermicron-sized aerosols originating from biomass burning in southern Central Africa

During the 3 years of the ObseRvations of Aerosols above CLouds and their intEractionS (ORACLES) campaign, the NASA Orion P-3 was equipped with a 2D stereo (2D-S) probe that imaged particles with maximum dimension (D) ranging from 10 < D < 1280 µm. The 2D-S recorded supermicron-sized aerosol particles (SAPs) outside of clouds within biomass burning plumes during flights over the southeastern Atlantic off Africa's coast. Numerous SAPs with 10 < D < 1520 µm were observed in 2017 and 2018 at altitudes between 1230 and 4000 m, 1000 km from the coastline, mostly between 7–11° S. No SAPs were observed in 2016 as flights were conducted further south and further from the coastline. Number concentrations of refractory black carbon (rBC) measured by a single particle soot photometer ranged from 200 to 1200 cm –3 when SAPs were observed. Transmission electron microscopy images of submicron particulates, collected on Holey carbon grid filters, revealed particles with potassium salts, black carbon (BC), and organics. Energy-dispersive X-ray spectroscopy spectra also detected potassium, a tracer for biomass burning. These measurements provided evidence that the submicron particles originated from biomass burning. NOAA Hybrid Single-Particle Lagrangian Integrated Trajectory (HYSPLIT) 3 d back trajectories show a source in northern Angola for times when large SAPs were observed. Fire Information for Resource Management System (FIRMS) Moderate Resolution Imaging Spectroradiometer (MODIS) 6 active fire maps showed extensive biomass burning at these locations. Given the back trajectories, the high number concentrations of rBC, and the presence of elemental tracers indicative of biomass burning, it is hypothesized that the SAPs imaged by the 2D-S are examples of BC aerosol, ash, or unburned plant material.

54 ENVIRONMENTAL SCIENCES↗

Processing of the laser Doppler velocimeter signals

The laser Doppler velocimeter (LDV) is a probeless technique that provides a remote measurement of mean and fluctuating velocities. The measurement is actually obtained from small particles embedded in the flow which scatter light from an illuminating laser beam interference pattern. A portion of this scattered light is collected by a photomultiplier which yields an electronic signal whose frequency is directly proportional to the velocity of the small particles. The purpose of this paper is to describe and critically compare three techniques most used to process this electronic signal. These techniques are: (1) spectrum analyzer - a frequency scanning filter (frequency domain instrument), (2) wide-band frequency tracker - a frequency lock loop (frequency domain instrument), and (3) high-speed frequency counter - an interval timer (time domain instrument). The study determines the ability of each technique to process the LDV signal and yield velocity data to be used in determining the flow characteristics.

Meyers, J. F.↗

Carbon Fiber Risk Analysis

The scope and status of the effort to assess the risks associated with the accidental release of carbon/graphite fibers from civil aircraft is presented. Vulnerability of electrical and electronic equipment to carbon fibers, dispersal of carbon fibers, effectiveness of filtering systems, impact of fiber induced failures, and risk methodology are among the topics covered.

Source record↗

Intitialization, Conceptualization, and Application in the Generalized Fractional Calculus

This paper provides a formalized basis for initialization in the fractional calculus. The intent is to make the fractional calculus readily accessible to engineering and the sciences. A modified set of definitions for the fractional calculus is provided which formally include the effects of initialization. Conceptualizations of fractional derivatives and integrals are shown. Physical examples of the basic elements from electronics are presented along with examples from dynamics, material science, viscoelasticity, filtering, instrumentation, and electrochemistry to indicate the broad application of the theory and to demonstrate the use of the mathematics. The fundamental criteria for a generalized calculus established by Ross (1974) are shown to hold for the generalized fractional calculus under appropriate conditions. A new generalized form for the Laplace transform of the generalized differintegral is derived. The concept of a variable structure (order) differintegral is presented along with initial efforts toward meaningful definitions.

Lorenzo, Carl F.↗

High-Gradient Wien Spin Rotators at Jefferson Lab

Nuclear physics experiments performed in the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Laboratory (JLab) require spin manipulation of electron beams. Two Wien spin rotators in the injector keV region are essential at CEBAF to establish longitudinal polarization at the end station target, and to flip the polarization direction by ? rad to rule out false asymmetries. In a Wien filter, the homogeneous and independent electric and magnetic fields, along with the velocity vectors of the electrons that traverse it, form a mutually orthogonal system. The magnitude of the electrostatic field, established by biasing two highly-polished electrodes, defines the desired spin angle at the target yet deviates the beam trajectory due to the Lorentz force. The beam trajectory in the Wien is then re-established by adjusting the magnetic field, induced by an electromagnet encasing the device vacuum chamber. This contribution describes the evolution design and high voltage testing of Wien filters for spin manipulation at increased beam energies in the keV injector region, required by high precision parity violation experiments like MOLLER.

Palacios Serrano, G. G.↗

High-Gradient Wien Spin Rotators at Jefferson Lab

Nuclear physics experiments performed in the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Laboratory (JLab) require spin manipulation of electron beams. Two Wien spin rotators in the injector keV region are essential at CEBAF to establish longitudinal polarization at the end station target, and to flip the polarization direction by ? rad to rule out false asymmetries. In a Wien filter, the homogeneous and independent electric and magnetic fields, along with the velocity vectors of the electrons that traverse it, form a mutually orthogonal system. The magnitude of the electrostatic field, established by biasing two highly-polished electrodes, defines the desired spin angle at the target yet deviates the beam trajectory due to the Lorentz force. The beam trajectory in the Wien is then re-established by adjusting the magnetic field, induced by an electromagnet encasing the device vacuum chamber. This contribution describes the evolution design and high voltage testing of Wien filters for spin manipulation at increased beam energies in the keV injector region, required by high precision parity violation experiments like MOLLER.

Palacios Serrano, G. G.↗

Startup regime of high-efficiency tapering-enhanced FEL oscillator

In this paper, we present a design of a high-efficiency high-gain free-electron laser oscillator based on the use of a strongly tapered undulator for extracting energy from high-brightness electron beams. We provide an analytical model of the setup followed by numerical simulations for lasing at the wavelength of 13.5 nm. We discuss the optimization of the system in steady state and the conditions necessary for the pass-per-pass buildup of the power from shot noise level. We propose the use of fast phase shifters as a way to accelerate the buildup. Finally, we present time-dependent simulations of the oscillator and discuss the role of spectral filtering. The optimized working point yields a total energy conversion efficiency from the electron beam to output radiation above 1% at the wavelength of 13.5 nm.

Beam dynamics↗

Cleanroom Contamination Identification Method Development

During fabrication, assembly, and testing of spacecraft and flight hardware it is vital to avoid contaminants that can cause degradation and could result in significant failure. Yet, there is no existing contamination monitoring method that provides the identity of airborne particles in a cleanroom facility. Knowing the particle identities, would allow scientists and engineers to determine the source of the contaminants and prevent setbacks before they occur or cause damage. Current cleanliness monitoring methods include airborne particle counters (APCs), fallout filters, and visual inspections. Particle counts from APCs are the primary metric used to define a cleanroom class and hence its level of cleanliness, but do not provide identification nor can they differentiate between large and small sizes of particles. In addition, using fallout filters is not a proactive, timely, or representative approach to cleanroom contamination monitoring because these samples are only retrieved after 30 days and are placed away from spacecraft processing to avoid interference with operations. In contrast, the forced air sampling method can collect a sample within an hour at any location required and provide results in less than a day. This system uses a cassette and filter sample medium to capture airborne particles which are then taken to a scanning electron microscope with energy dispersive spectroscopy (SEM/EDS) to identify and size the captured particles. Development of forced air sampling into an established laboratory capability will allow for fast sampling and routine identification of unknown contamination sources within the cleanroom. The test method development required market research for an air sampling cassette that increases sample collection efficiency and a filter with low enough background contamination to allow differentiation between a blank (control) and the collected sample. It was determined that a conductive black cassette and a polycarbonate filter were the best options. Conductive black cassettes, in comparison to the standard styrene, are manufactured using polypropylene filled with carbon. This makes the cassette conductive and minimizes the tendency of particles to stick to the wall of the cassette due to electrostatic force. In previous trials a mixed cellulose ester (MCE) filter was used to capture the contaminants, however the rougher surface of the filter contributed to entrapment of the particles within the filter structure and made it harder to identify the particles. In comparison, track etched polycarbonate filters have random cylindrical pores and a smooth surface which contributes to uniform sample distribution on the surface of the filter. Future work includes: testing the system using control samples to determine the efficiency and suitability of the medium, performing sample collection in various environments to establish ideal operating parameters and analyzing contaminant particles using SEM/EDS and assistant characterization techniques. Once fully developed, employing the forced air sampling method will help to prevent damage to spacecraft, avoid schedule delays, and allow for mission success.

Hernandez Melendez, Jailyn M.↗

Tunable-Bandwidth Filter System

A tunable-bandwidth filter system (TBFS), now undergoing development, is intended to be part of a remote sensing multispectral imaging system that will operate in the visible and near infrared spectral region (wavelengths from 400 to 900 nm). Attributes of the TBFS include rapid tunability of the pass band over a wide wavelength range and high transmission efficiency. The TBFS is based on a unique integration of two pairs of broadband Raman reflection holographic filters with two rotating spherical lenses. In experiments, a prototype of the TBFS, was shown to be capable of spectral sampling of images in the visible range over a 200 nm spectral range with a spectral resolution of 30 nm. The figure depicts the optical layout of a prototype of the TBFS as part of a laboratory multispectral imaging system for the spectral sampling of color test images in two orthogonal polarizations. Each pair of broadband Raman reflection holographic filters is mounted at an equatorial plane between two halves of a spherical lens. The two filters in each pair are characterized by steep spectral slopes (equivalently, narrow spectral edges), no ripple or side lobes in their pass bands, and a few nanometers of non-overlapping wavelength range between their pass bands. Each spherical lens and thus the filter pair within it is rotated in order to rapidly tune its pass band. The rotations of are effected by electronically controlled, programmable, high-precision rotation stages. The rotations are coordinated by electronic circuits operating under overall supervision of a personal computer in order to obtain the desired variation of the overall pass bands with time. Embedding the filters inside the spherical lenses increases the range of the hologram incidence angles, making it possible to continuously tune the pass and stop bands of the filters over a wider wavelength range. In addition, each spherical lens also serves as part of the imaging optics: The telephoto lens focuses incoming light to a field stop that is also a focal point of each spherical lens. A correcting lens in front of the field stop compensates for the spherical aberration of the spherical lenses. The front surface of each spherical lens collimates the light coming from the field stop. After the collimated light passes through the filter in the spherical lens, the rear surface of the lens focuses the light onto a charge-coupled-device image detector.

Bailey, John W.↗

Spin polarization through axially chiral linkers: Length dependence and correlation with the dissymmetry factor

Abstract The chiral‐induced spin selectivity (CISS) effect relates to the spin‐selective electron transport through chiral molecules; therefore, the chiral molecules act as spin filters. In past studies, correlation was found between the magnitude of the spin filtering and the intensity of the circular dichroism (CD) spectrum (the first Compton peak) of the molecules. Since the intensity of the CD peak relates to both the magnitude of the electric and magnetic dipole transitions, it was not clear which of these properties correlate with the CISS effect. This work aims at addressing this question. By studying the spin‐dependent conduction and the CD spectra of the thiol‐functionalized enantiopure binaphthalene (BINAP) and ternaphthalene (TERNAP), we found that both BINAP and TERNAP exhibit a similar spin polarization of 50%, despite the first Compton peak in TERNAP being almost twice as intense as the peak in BINAP. These results can be explained by the similar values of their anisotropy (or dissymmetry) factor, g abs , which is proportional to the magnetic transition dipole moment. Hence, we concluded that the CISS effect is proportional to the transition dipole moment in chiral molecules, namely, to the dissymmetry factor.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High laser fluence ITO coatings utilizing a Fabry-Perot thin film filter to reduce effective absorption

Laser-induced damage threshold of transparent conductors, such as Indium Tin Oxide (ITO), is limited by their high optical absorption due to free carriers. However, the effective absorption of a transparent conductor thin film can be reduced by an order of magnitude, without changing the electrical characteristics of the film, when placed in a low electric field section of a multilayer coating. A Fabry-Perot thin film interference filter has both high transmittance and low electric field positions, so it is an ideal thin film structure for this application. Although Fabry-Perot interference filters are not known as particularly high laser-induced damage resistant coatings due to their resonant characteristics, a laser-induced damage threshold (LIDT) improvement of up to 8× was observed with this technique compared to single layer ITO coatings fabricated using either radio frequency magnetron sputtering or electron-beam deposition. Additionally, an approximately 4× LIDT improvement for a Fabry-Perot interference filter has been observed by the addition of ITO into the multilayer structure.

47 OTHER INSTRUMENTATION↗