Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electron tubes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Investigation of a quadrupole ultra-high vacuum ion pump

The new nonmagnetic ion pump resembles the quadrupole ionization gage. The dimensions are larger, and hyperbolically shaped electrodes replace the four rods. Their surfaces follow y sq. = 36 + x sq. (x, y in centimeters). The electrodes, 55 cm long, are positioned lengthwise in a tube. At one end a cathode emits electrons; at the other end a narrowly wound flat spiral of tungsten clad with titanium on cathode potential can be heated for titanium evaporation. Electrons accelerated by a dc potential of the surface electrodes oscillate between the ends on rotational trajectories, if a high frequency potential superimposed on the dc potential is properly adjusted. Pumping speeds (4-100 liter/sec) for different gases at different peak voltages (1000-3000V) at corresponding frequencies (57-100 MHz), and at different pressures 0.00001 to the minus 9 power Torr were observed. The lowest pressure reached was below 10 to the minus 10 power Torr.

Schwarz, H. J.↗

Angular momentum transfer to the inner Jovian satellites

Transfer of angular momentum from Jupiter to the four inner satellites in the presence of the Jovian magnetic field is considered. Electron-flux measurements near Io's flux tube and theoretical estimates of the electric currents flowing through the same flux tube are used to estimate the angular-momentum transfer during the evolutionary history of the Jovian system. The results show that the electric currents are sufficient to have produced an angular-momentum transfer from Jupiter equal to the present angular momentum of the inner satellites.

Mogro-Campero, A.↗

Charge coupled devices

The results are presented of a program to design, fabricate, and test CCD arrays suitable for operation in an electron-bombarded mode. These intensified charge coupled devices have potential application to astronomy as photon-counting arrays. The objectives of this program were to deliver arrays of 250 lines of 400 pixels each and some associated electronics. Some arrays were delivered on tube-compatible headers and some were delivered after incorporation in vacuum tubes. Delivery of these devices required considerable improvements to be made in the processing associated with intensified operation. These improvements resulted in a high yield in the thinning process, reproducible results in the accumulation process, elimination of a dark current source in the accumulation process, solution of a number of header related problems, and the identification of a remaining major source of dark current. Two systematic failure modes were identified and protective measures established. The effects of tube processing on the arrays in the delivered ICCDs were determined and are reported along with the characterization data on the arrays.

Walker, J. W.↗

Comment on the mechanism of operation of the impregnated tungsten cathode

Recent life-test measurements, over 20,000-30,000 h, on impregnated tungsten cathodes in tubes employing an open-type electron-gun structure, show emission current degradation with time. This is in contrast to those recently published by Rittner on B-type cathodes, run in close-spaced diodes, taken some years ago. These more recent life-test results are consistent with the model suggested by Forman and disputed by Rittner that the barium coverage on an impregnated cathode is less than a monolayer for most of its life and decreases with time.

Forman, R.↗

The International Ultraviolet Explorer

The instrumentation and functioning of the IUE are discussed. The design of the telescope, fine error sensors, echelle spectrographs, and television cameras, as well as their integration, is described. The optical characteristics of the IUE are listed and the schematic arrangement of the detector is depicted. Sources of background noise are assessed, including the thermionic effects in the UV converters and television tubes, radiation from the earth's trapped electron belts, wide angle white light scattering from the earth and sun, scattering of dispersed light caused by low dispersion gratings, photometric calibration, and photometric stability. IUE sensitivity changes during the first three years of operation are shown together with sensitivity curves for short and long wavelengths. Modes of wavelength determination are considered.

Boggess, A.↗

Ferm cathode operation in the test bed ion engine

A rapid start hollow cathode has been developed for high power ion thruster application. Using no low work function insert or heater, the Field Enhanced Refractory Metal (FERM) cathode electron emission occurs from a refractory metal tube concentric with the cathode barrel. Results are presented for FERM cathode operation in the high field strength Test Bed Ion Engine. Using a controlled glow discharge heating technique, cathode start up times of 1-2 secs are shown. Cathode V-I curves up to 35 ampere emission are presented and life limiting component erosion mechanisms, at these high current levels, are discussed.

Aston, G.↗

Definition and empirical structure of the range of stellar chromospheres-coronae across the H-R diagram: Cool stars

Major advances in our understanding of non-radiative heating and other activity in stars cooler than T sub eff = 10,000K has occured in the last few years. This observational evidence is reviewed and the trends that are now becoming apparent are discussed. The evidence for non-radiatively heated outer atmospheric layers (chromospheres, transition regions, and coronae) in dwarf stars cooler than spectral type A7, in F and G giants, pre-main sequence stars, and close bindary systems is unambiguous, as is the evidence for chromospheres in the K and M giants and supergiants. The existence of non-radiative heating in the outer layers of the A stars remains undetermined despite repeated searches at all wavelengths. Two important trends in the data are the decrease in plasma emission measure with age on the main sequence and decreasing rotational velocity. Variability and atmospheric inhomogeneity are commonly seen, and there is considerable evidence that magnetic fields define the geometry and control the energy balance in the outer atmospheric layers. In addition, the microwave observations imply that non-thermal electrons are confined in coronal magnetic flux tubes in at least the cool dwarfs and RS CVn systems. The chromospheres in the K and M giants and supergiants are geometrically extended, as are the coronae in the RS CVn systems and probably also in other stars.

Linsky, J. L.↗

Astrobiology: The Search for Life in the Universe

Each of the 11 lead members of NASA's Astrobiology Institute has a specific mission. According to Hiroshi Ohmoto, director of Penn State s Astrobiology Research Center, Here we are mainly concerned with the origin of life and the evolution and extinction of important organisms. These include bacteria that live on methane, cyanobacteria (the inventors of photosynthesis), eukaryotes (a big category, covering anything with a nucleus, from single-celled organisms to humans), land-dwelling organisms, and early animals. Penn State astrobiologists are studying the environment before there was life on Earth, the origin of oxygen in the atmosphere, the chemical and thermal structures of oceans, and the role of metals in the evolution of life. Overall, they want to understand the connection between changes in environment and changes in life forms in the early Earth. PSARC offers research assistantships for graduate and undergraduate students, fellowships for graduate students and post-doctoral fellows, and an undergraduate minor in astrobiology. The minor covers 18 credits in earth sciences, geochemistry, geophysics, astronomy, biology, biochemistry, meteorology, and microbiology. The goal, says Ohmoto, is to teach students to critically evaluate claims related to this field that they encounter well after their college education has ended. Under a scanning electron microscope, Martian meteorite ALH84001 yields tube-like structures that look a lot like remnants of Earthly bacteria except smaller by a factor of ten.

Pacchioli, David↗

Boron Nitride Nanoribbons from Exfoliation of Boron Nitride Nanotubes

Two types of boron nitride nanotubes (BNNTs) were exfoliated into boron nitride nanoribbons (BNNR), which were identified using transmission electron microscopy: (1) commercial BNNTs with thin tube walls and small diameters. Tube unzipping was indicated by a large decrease of the sample's surface area and volume for pores less than 2 nm in diameter. (2) BNNTs with large diameters and thick walls synthesized at NASA Glenn Research Center. Here, tube unraveling was indicated by a large increase in external surface area and pore volume. For both, the exfoliation process was similar to the previous reported method to exfoliate commercial hexagonal boron nitride (hBN): Mixtures of BNNT, FeCl3, and NaF (or KF) were sequentially treated in 250 to 350 C nitrogen for intercalation, 500 to 750 C air for exfoliation, and finally HCl for purification. Property changes of the nanosized boron nitride throughout this process were also similar to the previously observed changes of commercial hBN during the exfoliation process: Both crystal structure (x-ray diffraction data) and chemical properties (Fourier-transform infrared spectroscopy data) of the original reactant changed after intercalation and exfoliation, but most (not all) of these changes revert back to those of the reactant once the final, purified products are obtained.

boron nitride nanotube↗

Large-scale counterstreaming of H(+) and He(+) along plasmaspheric flux tubes

An interhemispheric plasma transport model is used to study the flow characteristics of H(+), He(+), and O(+) along closed geomagnetic field lines for solstice conditions. The model corresponds to a time-dependent solution of the coupled continuity, momentum, and energy equations for the ions and electrons. The equations are solved along an entire flux tube from 120 km in one hemisphere to 120 km in the other hemisphere. The calculations are carried out for noon conditions for the flux tube passsing through Millstone Hill, at L = 3.2. The main conclusion is that H(+)-He(+) counterstreaming can be expected along a large segment of a plasmaspheric flux tube at solstice. For both symmetric and asymmetric wind patterns, the He(+) flow is from the winter to the summer ionosphere not only in the steady state, but during flux tube refilling due to the winter helium bulge and the depletion of N2.

Richards, P. G.↗

Fullerene Derived Molecular Electronic Devices

The carbon Nanotube junctions have recently emerged as excellent candidates for use as the building blocks in the formation of nanoscale electronic devices. While the simple joint of two dissimilar tubes can be generated by the introduction of a pair of heptagon-pentagon defects in an otherwise perfect hexagonal grapheme sheet, more complex joints require other mechanisms. In this work we explore structural and electronic properties of complex 3-point junctions of carbon nanotubes using a generalized tight-binding molecular-dynamics scheme.

Menon, Madhu↗

Measurement of the gas gain and understanding the gas flow in the Mu2e Tracker

The Mu2e experiment will search for the charged-lepton flavor violating (CLFV) neutrinoless conversion of a negative muon into an electron in the field of an Aluminum nucleus µ − N → e − N. The signature of this process is the emission of a monochromatic electron with an energy of 104.97 MeV. The Mu2e Tracker is a low mass straw tube detector, whose aim is to measure the position and the momentum of the electron. In past measurements, high values of currents were found in some panels of the Tracker in absence of any radioactive sources. In this report new measurements of currents, that were taken with the panel MN084 of the Mu2e Tracker are described. Moreover, the addition of a small amount of water vapour in the gas mixture and the influence of the environmental conditions on the currents of the panel are studied.

47 OTHER INSTRUMENTATION↗

Up-date of traveling wave tube improvements

NASA research in the area of traveling wave tube technology is reviewed, with emphasis on the basic physics of guns and collectors and a computer model for the interaction between the electron beam and the RF circuit. The design of a multistage depressed collector, capable of multiplying tube efficiency by a factor of two or more, is presented; one such design has been adopted for commercial traveling wave tube production. A three-dimensional model of electron trajectories toward the collector also receives attention, as does the problem of RF circuit losses.

Buck, E.↗

Transient effects in beam-plasma interactions in a space simulation chamber stimulated by a fast pulse electron gun

Interest in the interaction of electron beams with plasma generated by ionization caused by the primary electron beam was stimulated by the need to develop special vacuum tubes to operate in the kMHz frequency region. The experiments of Getty and Smullin (1963) indicated that the interaction of an energetic electron beam with its self-produced plasma resulted in the emission of wave energy over a wide range of frequencies associated with cyclotron and longitudinal plasma instabilities. This enhanced the thermal plasma density in the vicinity of the beam, and the term Beam-Plasma Discharge (BPD) was employed to described this phenomenon. The present investigation is concerned with some of the transient phenomena associated with wave emission during the beam switch-on and switch-off periods. Results are presented on the changes in electron energy spectra on a time scale of tens of milliseconds following beam switch-on. The results are discussed in terms of the beam plasma discharge phenomenon.

Raitt, W. J.↗

Effects of Geometric Azimuthal Asymmetries of the PPM Stack on Electron Beam Characteristics

The effects of geometric azimuthally asymmetric properties of a periodic permanent magnet (PPM) focusing stack on electron beam characteristics obtained using a fully three dimensional (3D) particle-in-cell (PIC) code will be presented. The simulation model, using MAFIA (Solution of MAxwell's equations by the Finite-Integration-Algorithm), incorporates 3D behavior of the beam immersed in static fields calculated directly from the exact geometry and material properties of the 3D magnetic focusing structure. The Hughes 8916H, 18-40 GHz helical TWT for the millimeter-wave power module (MMPM) was used as a prototype. Firstly, the effects of C-magnets used at the input and output of the TWT to allow for coupling of the RF signal into and out of the tube are considered. The 8916H input and output C-magnets differ because coaxial couplers are used at the input and waveguide couplers are used at the output The repositioning of the beam from its central axis due to the inclusion of the output C-magnet was found to be most significant. The modeled output C-magnet and its orientation in the Cartesian coordinate system is shown, and a two-dimensional beam profile including the output C-magnet is also shown. A table presents the shift of the beam center off the central axis relative to the average radius of the beam at the longitudinal points A, B and C designated on an enclosed figure. Secondly, the addition of shunts, or rectangular iron pieces applied manually by a skilled technician in order to improve beam transmission, is considered. The shunts are applied to the top of the tube; thus, azimuthal symmetry of the focusing stack is interrupted. Although shunts are typically added during RF focusing, they are also typically added at the input section of the tube where RF forces are minimal, making an electron optics analysis meaningful. Because several shunts are usually applied to one pole piece, the simulations have been simplified by modeling a half washer with the same radius and longitudinal length as a shunt over the entire x, positive-y half of the transverse plane. A modeled pole piece and shunt as described are shown. Lastly, in order to study the effects of magnet misalignments, a magnet in the PPM stack was arbitrarily chosen and adjusted so that its central axis was shifted both 0.7 percent and 1.0 percent of the magnet outer diameter in the positive-y direction. In practice, positioning the magnets so that their central axis is accurately aligned with the central axis of the tube is challenging. Thus, it is a strong possibility that one or more magnets will be misaligned relative to the tube central axis.

Kory, Carol L.↗