Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electricity demand”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Quantifying agricultural productive use of energy load in Sub-Saharan Africa and its impact on microgrid configurations and costs

The use of advanced energy technologies for agricultural purposes—such as irrigation, refrigeration, crop processing, and egg incubation—has the potential to increase crop yield, reduce vulnerability to changing precipitation patterns, increase shelf life, strengthen income and employment opportunities in rural areas, and reduce emissions by displacing fossil fuel-based technologies. These productive uses of energy (PUE) in remote areas could potentially be powered by microgrids that additionally serve otherwise unelectrified communities, most of which are located in rural Sub-Saharan Africa. Here, in this paper, we use high-resolution geospatial data to estimate the end-use electricity demand for a range of agricultural PUE across Sub-Saharan Africa, and we share these data in an open-access mapping tool. Next, we use REopt®, a techno-economic optimization model of energy systems, to determine the cost and system sizing implications of incorporating agricultural PUE into microgrid designs in Kenya and Zambia. We estimate the upper bound of agricultural PUE demand for irrigation, milling, shelling, refrigeration, and egg incubation across Sub-Saharan to be 16.8 TWh/yr. We find that incorporating local agricultural PUE into microgrid system designs increases the required system sizing while having minimal impact on the levelized cost of energy of these systems. Our analysis is the first to demonstrate the PUE potential in the agricultural sector at a 10x10-kilometer resolution across Sub-Saharan Africa and to show, at scale, how site-specific PUE can impact the cost and sizing of microgrids that are otherwise deployed to serve local household and community load.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evaluating the impact of wildfire smoke on solar photovoltaic production

There are growing needs to understand how extreme weather events impact the electrical grid. Renewable energy sources such as solar photovoltaics are expanding in use to help sustainably meet electricity demands. Wildfires and, notably, the widespread smoke resulting from them, are one such extreme event that can impair the performance of solar photovoltaics. However, isolating the impact that smoke has on photovoltaic energy production, separate from ambient conditions, can be difficult. In this work, we seek to understand and quantify the impacts of wildfire smoke on solar photovoltaic production within the Western United States. Our analysis focuses on the construction of a random forest regression model to predict overall solar photovoltaic production. The model is used to separate and quantify the impacts of wildfire smoke in particular. To do so, we fuse historical weather, solar photovoltaic energy production, and PM2.5 particulate matter (primary smoke pollutant) data to train and test our model. The additional weather data allows us to capture interactions between wildfire smoke and other ambient conditions, as well as to create a more powerful predictive model capable of better quantifying the impacts of wildfire smoke on its own. We find that solar PV energy production decreases 8.3% on average during high smoke days at PV sites as compared to similar conditions without smoke present. Finally, this work allows us to improve our understanding of the potential impact on photovoltaic-based energy production estimates due to wildfire events and can help inform grid and operational planning as solar photovoltaic penetration levels continue to grow.

14 SOLAR ENERGY↗

Modeling the impact of extreme summer drought on conventional and renewable generation capacity: Methods and a case study on the Eastern U.S. power system

Across recent years, there has been a growing prevalence of extreme weather events throughout the United States, posing significant challenges to the reliable and resilient operation of power systems. Specifically, summer droughts threaten to severely reduce available generation capacity to meet regional electricity demand, potentially leading to power outages. This underscores the importance of accurate resource adequacy (RA) assessment to ensure the reliable operation of the nation’s energy infrastructure. Accurately evaluating the usable capacity of regional generation fleets is a challenging undertaking due to the intricate interactions between power systems and hydro-climatic systems. Here, this paper proposes a systematic and analytical framework to evaluate the impacts of extreme summer drought events on the available capacity of various generating technologies, incorporating both meteorological and hydrologic factors. The framework provides detailed plant-level capacity derating models for hydroelectric, thermoelectric, and renewable power plants, facilitating evaluations with high temporal and spatial resolution. The application of the proposed impact assessment framework to the 2025 generation fleet of the real-world power system within the PJM and SERC regions of the United States yields insightful results. By analyzing the daily usable capacity of 6,055 at-risk generators across the study region, it shows that the summer capacity deration is most significant for hydroelectric and once-through thermal power plants, followed by recirculating thermal power plants and combustion turbines. In the event of the recurrence of the 2007 southeastern summer drought event in the near future, the generation fleet could experience a substantial reduction in available capacity, estimated at approximately 8.5 GW, compared to typical summer conditions. The sensitivity analysis reveals that the usable capacity of the generation fleet would suffer an even more significant decrease under conditions of increasingly severe summer droughts. The proposed approach and the findings of this study provide valuable methodologies and insights, empowering stakeholders to bolster the resilience of power systems against the potentially devastating effects of future extreme drought events.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Sustainable aviation fuel from ethanol: Techno-economic analysis and life cycle analysis

Sustainable aviation fuel (SAF) is crucial for improving energy security, enhancing domestic production, and reducing carbon emissions in the aviation sector. Among various SAF production technologies, the ethanol-to-jet (ETJ) pathway is a promising option due to its economic viability and technological maturity. This study integrates a techno-economic analysis (TEA) and a life cycle analysis (LCA) to evaluate emissions reduction strategies for SAF production via the ETJ pathway, considering use of ethanol derived from both corn grain and corn stover. Conventional corn grain-derived ETJ fuel reduces greenhouse gas (GHG) emissions by 22 % compared to fossil jet fuel, with potential reductions of 26 %–96 % when incorporating renewable energy sources, with a 6 %–32 % increase in the minimum fuel selling price (MFSP). Corn stover-derived ETJ achieves a 77 % GHG reduction but with higher MFSPs compared to corn grain ETJ. Carbon capture and storage (CCS without considering the cost for piping and sequestration, only compression) reduces the emissions of corn grain-derived ETJ by up to 32 gCO 2 e/MJ and enables negative emissions for corn stover-derived ETJ, with MFSP increases ranging from 1 % to 22 %. While carbon capture and utilization (CCU) increase ethanol yield by 47 %, it raises MFSPs by 54 % due to high electricity demand. Sustainable farming practices provide only limited carbon intensity (CI) reductions individually but do offer cumulative benefits when combined. These findings highlight the trade-offs between cost and environmental impact, providing insights to optimize SAF production strategies and support aviation sector goals for emissions reduction.

09 BIOMASS FUELS↗

Assessing Climate Change-Induced Variability in Generation Potential and Droughts of Renewable Energy Systems in India

Solar photovoltaic (PV) and wind energy systems are crucial for decarbonizing the electricity sector and achieving climate goals. However, these systems are weather-dependent, and ignoring the potential changes in their generation levels due to climate change could compromise achieving climate targets and meeting future electricity demand. This study evaluates the impact of climate change on the generation potential of wind and solar PV systems in India for three future periods, 2030 (2021-2040), 2050 (2041-2060), and 2070 (2061-2080) compared to the baseline year 2000 (1991-2010), under three emission scenarios: SSP245, SSP370, and SSP585. Solar PV generation levels consistently decline (up to 10 %) across all regions and scenarios. Wind energy shows more pronounced variability (-20 % to 30 %). The South and Southeastern regions of India show improvements in wind potential across all scenarios and time periods. This study also investigated the projected changes in the generation droughts of both energy systems. For solar PV, drought days increase across most regions (exceeding 500 days under SSP370 across the 20-year period). In contrast, wind energy sees a reduction in drought days, especially in parts of South and Southeast India (declines exceeding 50 days across different scenarios). For both energy systems, the patterns of generation drought and generation potential are similar, and indicate that Western and Northern India may be less favorable for the future expansion of solar PV and wind energy, respectively. These results highlight the need to account for the potential impacts in future capacity planning.

14 SOLAR ENERGY↗

A review of energy storage for power system resilience: Functions, metrics, and applications

Aging infrastructure, increasing operational complexity, and surging electricity demand from artificial intelligence and electrification are straining the grid and heightening the risks of disruptions, making resilience a critical priority. Energy storage is increasingly deployed to provide critical power supply, fast grid support, and rapid restoration. However, current practice lacks consistent metrics and systematic methodologies to rigorously quantify the resilience benefits of storage. This paper provides a comprehensive review of energy storage in resilience enhancement, focusing on functional roles, quantification metrics, and integration strategies. A structured resilience metrics library is compiled and categorized to encompass both technical and economic performance aspects. Existing methodologies for resilience-oriented storage planning and operations are critically examined. Key technical and practical challenges are identified, and future research directions are outlined to strengthen storage contributions to grid resilience.

Benefit quantification↗

Experimental investigation on phase change material–based finned tube heat exchanger for thermal energy storage and building envelope thermal management

Phase change materials (PCMs) are attractive solutions for thermal energy storage (TES) applications by absorbing and releasing large amounts of latent heat during solid–liquid phase transitions. However, their relatively low thermal conductivity requires novel heat exchanger–based solutions to improve the power density and overall energy storage efficiency of the TES system. This work presents the design and experimental results of a finned tube heat exchanger to store collected natural thermal energy from a building envelope in a latent-based TES and to release it later for building heating/cooling applications. We experimentally evaluate the finned tube heat exchanger and evaluate the performance of TES in reducing building heating and cooling loads over 3–4 h of desired time of operation (e.g., peak load). The optimized design allows for maximum energy density by minimizing the heat exchanger volume, and the system is evaluated experimentally using commercially available heat exchanger materials and an organic PCM. Here, the experimental results reveal that the TES system is able to charge and discharge stored latent energy within 3–4 h, matching peak building electricity demand duration under an average fluid flow rate of 0.136 kg/s and temperature difference of 5.55 °C. Importantly, such optimized designs illuminate a path toward TES designs that are low-cost, scalable, and optimized for thermal energy and power availability under the desired time of operation.

25 ENERGY STORAGE↗

Benefits assessment of cool skin and ventilated cavity skin: Saving energy and mitigating heat and grid stress

This study assessed the energy-saving and climate-adaptive potential of cool skin and ventilated cavity skin facade technologies in Seoul's high-rise apartment buildings. We created weather scenarios for historical, mid-term future, and long-term future conditions using Coordinated Regional Downscaling EXperiment (CORDEX) method. Building energy simulations were conducted on a South Korean high-rise apartment model to evaluate their performance under different weather conditions. The results indicate that cool skin and ventilated cavity skin technologies can save cooling energy during summers but lead to heating energy penalties in winters. Ventilated cavity skin outperforms cool skin, offering better cooling energy savings and reduced heating penalties. Combining both technologies yields the highest overall energy savings, with 7 %, 9 %, and 10 % cooling energy savings for cool skin, ventilated cavity skin, and the combined package, respectively. However, cool skin increases heating energy consumption by 5 %, while ventilated cavity skin has minimal impact on heating energy. These envelope technologies also reduce peak electricity demand by at least 5 %, 8 %, and 9 %, respectively. They contribute to heat stress reduction, enhance resilience, and decrease extreme heat risks for occupants during power outages by at least 18 % under various weather conditions. Considering the prevalence of aging high-rise apartments in South Korea, adopting these envelope renovation strategies can effectively reduce cooling loads, enhance thermal comfort, and boost resilience under future climates, while avoiding costly reconstruction.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cool rooms for indoor heat resilience: Evaluating affordable cooling strategies in heat-stressed California homes

Extreme heat conditions pose significant indoor survivability challenges for resource-constrained communities, which often lack access to cooling, have poorly insulated homes, and face compounding socioeconomic vulnerabilities. Moreover, concurrent power outages worsen health risks and heat-related illnesses. It is therefore crucial to develop innovative and affordable cooling approaches to protect vulnerable populations. This study assesses the efficacy of “cool rooms”– a designated space within a home equipped with passive and low-power active cooling measures to maintain safe indoor temperatures during extreme heat events and power disruptions. Using a physics-based building energy modeling approach, we evaluate the efficacy of various retrofit packages in maintaining thermal safety within the cool room under recent extreme heat conditions. The results indicate that passive measures can reduce 64% of hours with unmet standard effective temperatures, while the combination of passive and low-power active measures with built-in batteries further cuts this to 86%. Nevertheless, these strategies remain insufficient to maintain indoor thermal safety during extended outages. In contrast, integrating a solar-powered mini-split heat pump, whose technical potential was evaluated in this study, reduces indoor air temperatures below the 28 °C overheating threshold and significantly improves indoor habitability. The localized cool room strategy also offers potential for grid resilience by reducing peak electricity demand by up to 70% compared to whole house cooling during heat waves. The findings can inform the development of actionable heat mitigation plans and retrofit policies for residential communities with relatively low adoption of air conditioning such as warm marine climates.

Cool room↗

A bi-level advanced control framework for large-scale control of buildings with system-level impact

Increased electricity consumption combined with new forms of generation is testing the reliability of our grid infrastructure. This work describes a method to improve the reliability of the grid through large-scale advanced building control. This paper develops a bi-level distributed control framework to shift the load of 153 buildings to achieve a system-level objective of tracking a power reference signal. This bi-level control is based on the previously-developed ANPV-MPC, a predictive controller that uses a Bayesian neural network to generate an accurate control model and adapt to changing conditions over time. By shifting the building electricity demand to better match the available power, the grid system supplying the buildings is more reliable as evidenced by the analysis of node voltages across an IEEE 13-bus distribution system. The proposed bi-level control framework tracks the system-level power reference with enough accuracy to regulate node voltages across the IEEE 13-bus distribution system within ANSI limits of ±5%. Additionally, the adaptive nature of ANPV-MPC allows each building across the system to adapt to changing conditions, further amplifying the system-level reliability.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hierarchical semi-Markov models with duration-aware dynamics for activity sequences

Residential electricity demand at granular scales is driven by what people do and for how long. Accurately forecasting this demand for applications like microgrid management and demand response therefore requires generative models for activities that can produce realistic daily activity sequences, capturing both the timing and duration of human behavior. This paper develops a generative model of human activity sequences using nationally representative time-use diaries at a 10-min resolution. We use this model to quantify which demographic factors are most critical for improving predictive performance. We propose a hierarchical semi-Markov framework that addresses two key modeling challenges. First, a time-inhomogeneous Markov router learns the patterns of “which activity comes next.” Second, a semi-Markov hazard component explicitly models activity durations, capturing “how long” activities realistically last. To ensure statistical stability when data are sparse, the model pools information across related demographic groups and time blocks. The entire framework is trained and evaluated using survey design weights to ensure our findings are representative of the U.S. population. On a held-out test set, we demonstrate that explicitly modeling durations with the hazard component provides a substantial and statistically significant improvement over purely Markovian models. Furthermore, our analysis reveals a clear hierarchy of demographic factors: Sex, Day-Type, and Household Size provide the largest predictive gains, while Region and Season, though important for energy calculations, contribute little to predicting the activity sequence itself. The result is an interpretable and robust generator of synthetic activity traces, providing a high-fidelity foundation for downstream energy systems modeling.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A data-driven model for thermodynamic properties of a steam generator under cycling operation

The varying electricity demand from coal power plants due to the intermittent nature of renewable sources leads to load-follow and on/off operations referred to as cycling. Cycling causes transients of properties such as pressure and temperature within various components of the steam generation system.These transients cause increased damage because of fatigue and creep-fatigue interactions shortening the life of components. An algorithm is developed to identify cycling operations from the gross power data. The data-driven model based on artificial neural networks (ANN) is developed using 10 years data from Coal Creek Station power plant located in North Dakota, USA to estimate properties of the steam generator components during cycling operations. Furthermore, the uniqueness of this model is the ability to predict component properties for the cycling as well as base-load operations and is reported for the first time. The ANN model estimates the component properties, for a given gross power profile and initial conditions, as they vary during cycling operations. As a representative example, the ANN estimates are presented for the superheater outlet pressure, reheater inlet temperature, and flue gas temperature at the air heater inlet. The changes in these variables as a function of the gross power over the time duration are compared with measurements to assess the predictive capability of the model. Mean square errors of 4.49E-04 for superheater outlet pressure, 1.62E-03 for reheater inlet temperature, and 4.14E-04 for flue gas temperature at the air heater inlet were observed.

01 COAL, LIGNITE, AND PEAT↗

An interregional optimization approach for time series aggregation in continent-scale electricity system models

Modeling electric power systems with high shares of weather-dependent resources requires tradeoffs between temporal, spatial, and operational resolution. Many studies perform time series aggregation using clustering algorithms to reduce the temporal dimension, but when modeling continent-scale electricity systems that are large enough to contain multiple independent weather systems, this approach requires large numbers of representative periods to minimize errors in regional wind and solar capacity factors. Here, a new optimization-based approach for representative period selection and weighting is introduced that minimizes regional errors in average renewable capacity factors and electricity demand. The method delivers higher regional fidelity with fewer representative periods than alternative clustering methods when applied to wind, solar, and demand profiles for the contiguous United States. When representative periods are selected from multiple weather years, the optimized method reproduces regional averages with lower error than a complete 365-day time series from any single weather year. The method identifies only representative (as opposed to outlying) periods but can be combined with an iterative "stress period" identification approach to guide efficient decision-making considering both average and high-risk weather conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Go slow to go fast? A review of the impacts of permitting on large-scale solar project development

State and local permitting challenges could impede the ability of large-scale solar (LSS) to meet growing electricity demand in the United States. Here, we review research that explores LSS permitting and its impacts on the pace and scale of LSS project development. Research on LSS permitting is relatively scarce, such that we support our review with research in the context of wind permitting, where appropriate. Further, few studies attempt to rigorously quantify the effects of permitting on the pace and scale of LSS project development. The available evidence allows us to identify various hypotheses and identify gaps for further research. Our review suggests that differences in permitting policies, regulations, and ordinances explain relatively little variation in LSS permitting and development outcomes across jurisdictions, except where jurisdictions implement rules designed to impede LSS. The evidence suggests LSS permitting challenges largely accrue during the implementation of permitting processes. Recent research suggests that community opposition to project development is a key driver of LSS permitting challenges, given that project opponents often use permitting processes to translate opposition into legal action. We call on future researchers to more concretely describe the LSS permitting challenge and to identify the specific actors responsible for implementing solutions.

Community opposition↗

Experimental apparatus and methodology to test and quantify thermal performance of micro and macro-encapsulated phase change materials in building envelope applications

Thermal energy storage (TES) is used as a viable technology to shift peak electricity demand caused by the space cooling requirements in buildings. Passive TES is implemented in building envelope via micro and macroencapsulation methods. This study describes the use of a state-of-the-art laboratory to test different PCM inclusions in simplified building walls. A microencapsulated PCM and two macroencapsulated PCMs are tested in a controlled environment to gather data for validation purposes of PCM modelling algorithms in building energy modelling programs. Data indicates that the chamber environment and the heating and cooling system can conduct full-cycle tests of wall panels with PCM inclusions. This study also generates data from parallel tests on 4 wall panels which can be used in building energy modelling programs to validate the PCM modelling algorithms. The cyclic tests also capture the thermal effects of PCMs and complex PCM behaviors like sub-cooling in PCM hydrate-salts.

25 ENERGY STORAGE↗

An approach for fast and accurate simulation of phase change material based thermal energy storage in buildings

Latent heat thermal energy storage (LHTES) has significant potential for mitigating peak electricity demand and enabling load shifting in buildings. Phase Change Material embedded heat exchangers (PCM-HX) can significantly improve energy demand management due to high storage capacity. However, PCM-HX evaluation typically depends on computationally expensive fully transient simulations, posing significant challenges for scalable system- and building-level energy assessments across different climates and system architectures. This paper presents a generalized, accurate, and computationally efficient methodology for simulating building energy systems integrated with LHTES. The PCM-HX transient performance is represented by performance maps generated using a Generalized Resistance-Capacitance Model (GRCM) that enables accurate predictions of arbitrary PCM-HXs at low computational cost. The feasibility of the proposed approach was verified using a case study considering a dual-mode heat pump-thermal energy storage (HP-TES) system simulated in Modelica with Spawn of EnergyPlus™ for a DOE prototype small office building in two locations: Tampa, FL, and International Falls, MN. The PCM-HX performance maps provided accurate predictions of PCM-HX transient behavior, with mean absolute percentage deviations within 2–4% compared to GRCM while also achieving at least 1800× reduction in computational time. Moreover, the HP-TES system achieved energy savings of up to 17.4% in Tampa, FL, and 62.2% in International Falls, MN, demonstrating the broader applicability of the proposed methodology across different climate zones. This work highlights the importance of robust PCM-HX models in enabling accurate and computationally efficient building-level simulations and enabling future research opportunities for investigating optimized HP-TES designs and advanced control strategies for grid-interactive buildings.

Modelica↗

Empirical characterization of vertical-tube inlets in hot-water storage tanks

Hot-water storage in residential and commercial tanks is of growing interest for peak-shifting the electrical demand associated with hot-water loads. How the water enters the tank can significantly affect the extraction efficiency of the storage. Vertical-tube inlets (VTIs) direct cold water into the tank. The VTI design influences whether large-scale mixing occurs, which can reduce the delivery capacity of the hot-water storage. In this work, the mixing at the VTI discharge was characterized by the eddy diffusivity factor (EDF) in an allometric curve fit to the ratio Re:Ri using inlet superficial velocities. The full experimental campaign tested VTI's with Re’s between 170 and 22,300 and Ri's between 0 and 376. Animated visualization of the experimentally measured data is provided, showing tank temperature evolution during inlet flows. The most predictive correlations for EDF are for VTI Re in the transition zone (i.e. ~2300 < Re < ~10,000) and at a Ri corresponding to a stably stratified tank (i.e. Ri > 5). For vertical-tubes that distribute cold water below the thermocline, increasing the EDF will decrease the stratification in a hot-water tank as EDF quantifies inlet mixing. Overall, the new correlations for VTIs can be used to design and model thermally-stratified storage tanks.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗