At least 307 records · Page 17

Quantifying the Impact of Electric Fields on the Local Structure and Migration of Potassium Ions at the Orthoclase (001) Surface

Developing an understanding of the response of mineral/water interfaces to applied electric fields is central to detecting and interpreting signatures of interfacial processes in the subsurface. Here we focus density functional theory calculations on understanding K + cation binding and diffusion across the (001) surface of orthoclase feldspar under various applied electric fields with and without surface hydration. The calculations reveal how water ligands labilize surface K + cations for diffusion while also increasing their sensitivity to electric field effects on the binding energy at different surface sites. The calculations also show how the direction and strength of the electric field systematically affect surface cation mobility, sorption, and hydration behavior. Specifically, electric fields directed toward the surface increase the potassium binding energies, facilitate K + diffusion across multiple binding sites, and increase the propensity of surface K + ions to lose their hydration shells. Furthermore, the findings help fill a major knowledge gap into the impact of electric fields on mineral/water interface structure and dynamics more generally, featuring in this case a commonly found type of feldspar involved in a multitude of atmospheric and geochemical processes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Thin film lithium niobate electric field sensors

We present our results for using thin film lithium niobate devices for electric field sensing applications. Micro-ring modulator and Mach–Zehnder modulator-based electric field sensors are demonstrated. Micro-ring resonator sensors can be used for low frequency (up to several GHz) electric field sensing applications and achieve a high sensitivity of 80 mV/(m Hz 1/2 ) with a very compact size of 300 μm, as limited by the intensity and phase noise of the used distributed feedback laser. A measurement bandwidth of 2.5 GHz is measured for these sensors and is limited by the detector bandwidth. Alternatively, Mach–Zehnder modulators allow for perfect phase matching between the radio frequency signals and optical signals, and they can be used for electric field sensing up to several THz. A sensitivity of 2.2 V/(m Hz 1/2 ) was obtained using our Mach–Zehnder electric field sensor with an interaction length of 600 μm. The Mach–Zehnder sensor can sense electric fields with frequencies reaching 0.6 THz based on the calculated results.

47 OTHER INSTRUMENTATION↗

Electron-field instability: Excitation of electron plasma waves by an electric field

Electric fields are commonplace in plasmas and affect transport by driving currents and, in some cases, instabilities. The necessary condition for instability in collisionless plasmas is commonly understood to be described by the Penrose criterion, which quantifies a sufficient relative drift between different populations of particles that must be present for wave amplification via inverse Landau damping. For example, electric fields generate drifts between electrons and ions that can excite the ion-acoustic instability. Here, we use particle-in-cell simulations and linear stability analysis to show that the electric field can drive a fundamentally different type of kinetic instability, named the electron-field instability. This instability excites electron plasma waves with wavelengths ≳30λ De , has a growth rate that is proportional to the electric field strength, and does not require a relative drift between electrons and ions. The Penrose criterion does not apply when accounting for the electric field. Furthermore, the large value of the observed frequency, near the electron plasma frequency, further distinguishes it from the standard ion-acoustic instability, which oscillates near the ion plasma frequency. The ubiquity of macroscopic electric fields in quasineutral plasmas suggests that this instability is possible in a host of systems, including low-temperature and space plasmas. In fact, damping from neutral collisions in such systems is often not enough to completely damp the instability, adding to the robustness of the instability across plasma conditions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Isotope effects under the influence of global radial electric fields in a helical configuration

Isotope effects under the influence of a radial electric field are examined in a helical magnetic field configuration. We perform global gyrokinetic simulations with additional poloidal rotations to estimate quasi-linear heat flux due to ion temperature gradient mode under the mixing length model. In single-ion-species plasmas, the mass number dependency of heat flux agrees with gyro-Bohm scaling in the absence of a radial electric field. Favorable mass number dependencies violating gyro-Bohm scaling are observed in the presence of a global radial electric field or a heavy hydrogen component in multi-ion-species plasmas. The radial electric field and the heavy hydrogen component affect the heat flux through an increase of wavelength as well as mode stabilization. Poloidal Mach number characterizes the transition from unfavorable to favorable mass number dependency under radial electric fields. While the heat flux is independent of mass number for a given poloidal Mach number, the heat flux decreases for higher mass numbers in a given radial electric field. The heat flux is also independent of average mass number in multi-ion-species plasmas because the heavy hydrogen component effectively enhances the light hydrogen heat flux. The present results are potentially relevant to the violation of gyro-Bohm scaling observed in the recent deuterium experiments in the Large Helical Device.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electrical conductivity of Sn at high pressure and temperature

To date, temperature and conductivity have many outstanding implications in extreme environments but are yet to be fully understood under high pressure and temperature dynamic conditions. Here, we introduce an approach to provide high quality electrical conductivity results under dynamic loading conditions. Emphasis is given to address the skin depth effect's influence in a dynamic loading experiment by using thin films. The thin film samples in this study were at least 100 times thinner than previous samples in dynamic electrical conductivity experiments, increasing the current density to its full potential across the sample's entire cross section. Consideration of the skin depth accounts for at minimum a 4× scaling factor to the final electrical conductivity result that has been neglected in previous dynamic electrical conductivity studies. We also obtained improved signal-to-noise ratio with custom diagnostics optimized for better electrical impedance matching. Furthermore, these considerations were applied to Sn to assess electrical conductivity at elevated pressure and temperature. The high signal-to-noise ratio with reduced skin depth influence results in Sn allowing observation of the conductivity changes related to solid-to-solid and solid-to-liquid phase transitions. Additionally, we calculate the Sn thermal conductivity using the Wiedemann-Franz law for our experiments and compare against thermal transport dependent temperature measurements from previous work.

36 MATERIALS SCIENCE↗

Separation of Kondo lattice coherence from crystal electric field in CeIn 3 with Nd substitutions

The Ce m M n In 3m+2n (m=1,2;n=0,1) family has been one of the most studied families of heavy fermion compounds. This family has revealed many interesting low-temperature physics phenomena, like quantum critical points, heavy fermion superconductivity, and non-Fermi liquid behavior, when these materials are exposed to pressure, magnetic fields, and/or chemical substitution. In this work, we provide a thorough investigation of the Ce 1-x Nd x In 3 phase diagram through single crystal synthesis, x-ray diffraction, energy-dispersive spectroscopy, magnetic susceptibility, and electrical resistivity measurements. Previous electrical resistivity measurements on CeIn 3 reveal a broad maximum, T max ~50 K, which has been associated with the Kondo lattice coherence crossover and/or the crystal electric field depopulation effect as the 4f electrons condense from the high-energy quartet down to the ground state doublet. Our findings show that in the most disordered substitution region, x=0.4–0.5, these features disjoin to reveal two distinct broad humps in electrical resistivity measurements. Magnetic susceptibility and electrical resistivity data on Ce 1-x Nd x In 3 also reveal the antiferromagnetic ordering competition between CeIn 3 and NdIn 3 , where the T N of CeIn 3 is linearly suppressed to a critical concentration of x Nd ~0.6. This concentration is slightly lower than what was previously reported in nonmagnetically substituted Ce 1-x La x In 3 . Our magnetic susceptibility measurements and subsequent simulations show that in the CeIn 3 antiferromagnetic regime, x Nd ≤0.4, the Nd ions act as free paramagnets. The large magnitude of the associated paramagnetic response then masks the overlapping antiferromagnetic ordering signature of the Ce ions. Overall our study further sheds light on the underlying crystal electric field and Kondo lattice coherence interactions within the Ce m M n In 3m+2n family and could stimulate further studies of these systems via neutron diffraction or under applied pressure.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Real-World Cyber Security Demonstration for Networked Electric Drives

In this article, we present the design and implementation of a cyber-physical security testbed for networked electric drive systems, aimed at conducting real-world security demonstrations. To our knowledge, this is one of the first security testbeds for networked electric drives, seamlessly integrating the domains of power electronics and computer science, and cybersecurity. By doing so, the testbed offers a comprehensive platform to explore and understand the intricate and often complex interactions between cyber and physical systems. The core of our testbed consists of four electric machine drives, meticulously configured to emulate small-scale but realistic information technology (IT) and operational technology (OT) networks. This setup both provides a controlled environment for simulating a wide array of cyber-attacks, and mirrors potential real-world attack scenarios with a high degree of fidelity. The testbed serves as an invaluable resource for the study of cyber-physical security, offering a practical and dynamic platform for testing and validating cybersecurity measures in the context of networked electric drive systems. As a concrete example of the testbed's capabilities, we have developed and implemented a Python-based script designed to execute step-stone attacks over a wireless local area network (WLAN). This script leverages a sequence of target IP addresses, simulating a real-world attack vector that could be exploited by adversaries. To counteract such threats, we demonstrate the efficacy of our developed cyber-attack detection algorithms, which are integral to our testbed's security framework. Furthermore, the testbed incorporates a real-time visualization system using InfluxDB and Grafana, providing a dynamic and interactive representation of networked electric drives and their associated security monitoring mechanisms. This visualization component not only enhances the testbed's usability but also offers insightful, real-time data for researchers and practitioners, thereby facilitating a deeper understanding of cyber-physical security dynamics in networked electric drive systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Summary Report of HERO WEC Test Article for Waves to Water: Electrical Power Take-Off

The National Renewable Energy Laboratory (NREL) designed and fabricated the hydraulic and electric reverse osmosis (HERO) wave energy converter (WEC), which is a modular system that can utilize either an electrical or hydraulic power take-off (PTO) system to power a desalination device. The method by which this device can convert mechanical work to either hydraulic or electrical energy is by harnessing the energy from waves via a rotary output shaft. This report describes the electrical configuration, where a rotary generator replaces the pump in the hydraulic configuration to power a submersible pump and reverse osmosis unit via an electrical cable, rather than a hydraulic line/hose. This device is of a non-proprietary design where every aspect of the design is made public, including the physical designs, non-proprietary cost data, and electrical drawings developed for the build of this device.

16 TIDAL AND WAVE POWER↗

LA100 Equity Strategies. Chapter 12: Distribution Grid Upgrades for Equitable Resilience and Solar, Storage, and Electric Vehicle Access

The LA100 Equity Strategies project integrates community guidance with robust research, modeling, and analysis to identify strategy options that can increase equitable outcomes in Los Angeles' clean energy transition. As Los Angeles transitions toward clean energy, existing distribution grid infrastructure will need to be updated and expanded to support reliable service during routine operations, enable interconnection with distributed energy resources and electrified loads, and provide access to energy-related services during disasters. This chapter focuses on equity in distribution grid upgrades, reliability, and resilience in Los Angeles. Specifically, NREL performed grid upgrade and resilience analyses using a detailed model of the distribution grid and income-differentiated household load profiles, electric vehicle (EV) adoption patterns, distributed solar adoption, and grid reliability to explore two key questions to inform how the City of Los Angeles can ensure a resilient and reliable distribution grid for all communities during the clean energy transition: Where can distribution system upgrades can be prioritized to enable equitable access to, and adoption of, clean energy technologies and how can Los Angeles provide equitable, resilient access to electricity-related services (e.g., health care, food) during disaster events like earthquakes and flooding? The electric distribution system is the "last mile" of the grid, linking the multistate bulk power system with customers; new loads, including EVs; and distributed energy resources, such as customer and community solar and storage. This analysis focuses on the 4.8-kilovolt (kV) system, including service transformers that represent the utility-side of the grid connection for most residential customers. Chapter 17 looks at the customer-side of the grid connection with a focus on electric panel upgrade needs. The transition toward clean energy can put additional stress on the distribution system from distributed energy resources and electrification - especially EVs and increased use of electricity for heating, cooling, cooking, and hot water. This stress, measured here as the number of equipment overloads and voltage violations, correlates strongly to grid reliability and therefore is used as a proxy for understanding additional upgrades needed and to help ensure equitable access to electrification and distributed energy resources. NREL also conducted community resilience analysis to examine customer-level access to both electricity and a larger range of services, such as hospitals and grocery stores during a disaster. This analysis explicitly considers equity to understand differences in current resilience and resilience strategies to effectively improve critical services access for all Angelenos. Research was guided by input from the community engagement process, and associated equity strategies are presented in alignment with that guidance.

14 SOLAR ENERGY↗

Electric Vehicle Supply Equipment (EVSE) Site Assessment Report for the U.S. Army Corps of Engineers Chena Site Near Fairbanks, Alaska

This report presents an analysis of the requirements for charging station installation and electric vehicle operation at the US Army Corps of Engineers - Chena Site, located in a cold weather climate in the Fairbanks North Star Borough, AK. The report includes findings from a site visit, and a detailed electric vehicle (EV) charging site plan with cost estimates. Cost for three 50-ampere pedestal chargers located on the edge of the existing parking lot is estimated at $\$$53,100, and the cost of three 80-ampere chargers is estimated at $\$$89,400. The authors did not assess the cost of a heated garage. The USACE Chena site reaches extreme cold temperatures of -40 Degrees Celsius (-40 Degrees Fahrenheit) and below in a typical winter, often for days on end. Considerations of operating EVs as well as electrical vehicle supply equipment (EVSE) at this site can be applicable to other cold or extremely cold locations. Interviews with EV users in cold climates and a literature review indicated that EVs operate well but have significantly decreased range compared to 21 Degrees Celsius (70 Degrees Fahrenheit) operations. Some strategies such as prewarming the vehicle while it is plugged in and using heated seats and steering wheel instead of cabin heat, can improve cold weather performance. Storing the EV in a garage would mean the battery and cabin are automatically preheated, the battery would not age as rapidly as when the vehicle is stored outside, and problems with charging the vehicle are less likely. Lowest temperate-rated Electric Vehicle Supply Equipment (EVSE), as electric vehicle chargers are known as, are rated to -40 Degrees Celsius (-40 Degrees Fahrenheit), and sometimes malfunction. No EVSE is rated to the temperatures that USACE Chena site experienced for more than a week in winter 2023-4, of -50 Degrees Celsius (-45 Degrees Fahrenheit) and which are typical for the area. If reliability is a must, entities may want to consider a heated garage to minimize potential problems with charging equipment. There is a companion technical report to this titled "Electric Vehicle and Charging Infrastructure Assessment in Cold-Weather Climates: A Case Study of Fairbanks, Alaska" that examines the data on EV and EVSE cold-weather functionality in more detail. (Esparza, Truffer Moudra, and Hodge 2024).

33 ADVANCED PROPULSION SYSTEMS↗

An Additively Manufactured Fe-3Si Stator for a High-Performance Electrical Motor

Additive manufacturing (AM) has the potential to produce novel high-performance electrical machines, enabling the direct printing of complex shapes and the simultaneous processing of multiple feedstocks in a single build. We examined the properties and functional performance of Fe-3 wt.% Si materials that were printed via selective laser melting, machined down to thin laminates, and stacked to form a stator core of a prototype brushless permanent-magnet electrical motor. Big Area Additive Manufacturing of Nd2Fe14B (NdFeB)–polyphenylene sulfide (PPS) bonded magnets was performed, with them then being magnetized and used for the rotor. The magnetic, mechanical, and electrical properties of the as-printed and various heat-treated thin laminates and the back electromotive force (EMF) of the electrical motors at different rotational speeds were measured. The thin laminates exhibit a maximum relative permeability of 7494 at an applied field of 0.8 Oe and a core loss of about 20 W/lb at 60 Hz with the maximum induction of 15 kg. In addition to the demonstration of AM printing, motor assembly, and complete characterization of printed Fe-3 wt.% Si, this report highlights the areas of improvement needed in printing technologies to achieve AM built electrical motors and the need for isotropic microstructure refinements to make the laminates appropriate for high-mechanical-strength and low-loss rotational electrical devices.

36 MATERIALS SCIENCE↗

Physically Realistic Estimates of Electric Water Heater Demand Response Resource

Multiple grid integration studies have examined the value of demand response, including from water heaters, to bulk power systems. Common shortcomings of these studies include physically unrealistic assumptions. For example, studies often assume that all electric water heater load can be shed for up to an hour to provide capacity or contingency service, that all electric water heater load is shiftable, and that round-trip efficiencies for shifting service are 100%. Another issue is that simply summing up estimates of individual water heaters' flexibility bounds, an attractive idea for constructing the MW-scale resources necessary for direct inclusion in grid investment and operational models, can result in significant overestimates of actual resource, because, e.g., a water heater with the ability to reduce load may not be able sustain the reduction for as long as the aggregate model suggests is possible. This presentation demonstrates the impact of estimating the flexibility of electric water heaters with physically realistic models suitable for grid service analysis. Electric water heater flexibility representations are constructed based on ResStock simulations of New England. Specifically, we examine contingency resource (related to capacity, shed, and contingency reserve services) and energy shifting resource from electric resistance and heat pump water heaters. Different estimation methods are compared; and the surrogate models' event responses are validated against events directly simulated in EnergyPlus. We also demonstrate the impact of using electric water heaters for contingency reserves and energy shifting in detailed models of possible future ISO New England power systems.

building energy modeling↗

Multiscale Electricity Modeling for Evaluating Carbon Capture and Sequestration Technologies (MEME-CCS)

This effort employs and adapts a rigorous multiscale electricity modeling platform at the National Renewable Energy Laboratory (NREL) to evaluate carbon capture and sequestration (CCS) and negative emissions technologies (NET) from the ARPA-E FLECCS program. NREL's modeling platform includes the Regional Energy Deployment System (ReEDS) electric sector capacity expansion model, which projects future electricity generation mixes at sub-state-level resolution that are downscaled to the unit-level to enable hourly, zonal or nodal electricity production cost modeling in the PLEXOS model. The ReEDS-PLEXOS modeling suite is well-established for examining electric sector futures with high renewable energy penetrations, energy storage, electrification, and distributed generation. The key advancement proposed herein utilizes collaboration with CCS experts at the University of Wyoming (U.WY) and the FLECCS technology development teams to create innovative methods for representing CCS and NET in the ReEDS and PLEXOS models. Expanded technology options and new operational parameterizations are integrated into these models to allow an unprecedented combination of scope and resolution for exploring the future of CCS and NET. The resulting capabilities permit wide-ranging scenario analysis to assess CCS and NET deployment under alternative scenarios of CO2 prices and competitiveness of flexible CCS and NET technologies. We demonstrate sample deployment and operational outcomes to show how these models are being used to assess the future potential for FLECCS technologies and their impacts on the U.S. electricity system. These products will help an emerging CCS/NET industry in the United States by providing economics-driven guidance to technology developers while informing policy and investment decisions in the public and private sectors.

capacity expansion↗

ELECTRIC FIELD-ASSISTED DIFFUSION WELDING TO FABRICATE ALLOY 617 COMPACT HEAT EXCHANGERS

Compact heat exchangers are of interest for a number of applications including advanced reactors. Alloy 617 is one of the top candidate materials for the gas-cooled reactor intermediate heat exchanger. Previous endeavors to diffusion weld Alloy 617 utilized hot pressing (HP). It was reported that grain boundary migration across the interface was hindered by extensive precipitation. Bonds of this nature have been observed to reduce the elevated-temperature mechanical properties compared to the wrought-product form. It was hypothesized that the electric current applied during electric-field-assisted sintering (EFAS) can overcome these challenges, resulting in improved diffusion welding (DW). This study investigated DW of Alloy 617 via EFAS. Stacks composed of three sheets that were 20 mm in diameter were welded using EFAS. Specimens were welded with an applied electric current, a pressure of 30 MPa, hold time of 30 min, and temperatures of 1050°C, 1100°C, and 1150°C. DW using HP as the zero-current analog of EFAS was also performed at the most promising EFAS conditions. Results revealed that both the applied electric current and temperature played a key role in precipitation and grain boundary migration in diffusion-welded Alloy 617. Precipitates were observed at the interface of the hot-pressed samples which limited grain boundary migration. Electric current was found to prevent precipitate formation along the interface at 1150°C. The electric current coupled with a temperature of 1150°C during EFAS resulted in significant grain boundary migration across the interface.

36 - MATERIALS SCIENCE↗

A Finite Difference Analysis of the Effect of Graphene Additions on the Electrical Conductivity of Polycrystalline Copper

A finite-difference method was used to explore the effect of graphene on the bulk electrical conductivity of copper-graphene composites. In this capacity, grain orientation information from pure copper and copper-graphene composites were used to generate synthetic 3D microstructures. The electrical conductivity of these microstructures were calculated using the finite difference method assuming different average grain sizes. From these calculations, we demonstrate that when high-conductivity grain boundaries are present within the microstructure arising from the presence of graphene, an increase in the bulk electrical conductivity is observed. On the other hand, the difference in textures between copper and copper-graphene composites may not account for a significant difference in bulk electrical conductivity. In comparison, the copper grain size has a considerably larger effect on electrical conductivity as previously anticipated. This is one of the first demonstrations of a physical basis for enhanced conductivity composites and presents pathways for further investigations on the effects of composite microstructural features, material interfaces and graphene content on electrical performance.

Frazier, William E.↗

Optimal electric-distribution-grid planning considering the demand-side flexibility of thermal building systems for a test case in Singapore

The planning of district-scale electric grids, i.e., distribution grids, has traditionally relied on finding the most cost-effective design such that they are able to supply the peak loads in a district. With the advent of electric demand side flexibility (DSF), there is the opportunity to reshape peak loads such that the investment cost of the electric grid decreases in exchange for a minor increase in the operation cost. This paper formulates an optimal planning approach for the electric grid at the district scale, which incorporates the DSF from thermal building systems, e.g., heating ventilation and air-conditioning (HVAC) systems. The problem is formulated as a mixed-integer linear program (MILP) and aims at minimizing the investment cost for the grid along with the operation cost of the flexible loads. This is subjected to the fixed electricity demand and thermal comfort constraints of building occupants. To this end, linear models for the thermal comfort in the buildings and the power flow in electric grid are considered. The approach is tested on a district planning test case based in Singapore, where the results show up to 30.9 % reductions in investment cost and up to 3.7 % reduction in total annualized cost. Urban planning authorities, developers and utility companies can all benefit from the presented approach to make optimized investment decisions. For building operators, the results point to the need of adopting their control systems for DSF.

Troitzsch, Sebastian↗

Low-temperature solar thermal-power systems for residential electricity supply under various seasonal and climate conditions

In this work, the performance of low-temperature (<100 degrees C) solar thermal-power systems to satisfy residential electric loads was analyzed. The solar-driven system was designed to provide a fraction of the total electricity demand in a complementary operation with the electric grid. The analysis was conducted for an coperation during seven days each season, considering real solar and climate variables and residential loads at different climate zones in the United States. The efficiency of the system strongly depends on the solar radiation profile and the ambient temperature. Maximum efficiencies of around 9.5% were obtained in the cold and marine climate zones due to the high solar energy input and low heat dissipation temperatures. In these two zones, the system could supply more than 98% of the electricity demand all seasons. At mixed-humid and hot-humid regions, the system supplied around 50% of the electric load in three of the four seasons, but it only supplies about 27% of the electricity needs in the mixed-humid zone during summer and hot-humid zone during winter. The effect of the solar collector field area and the tank volume was also analyzed. In general, larger solar fields positively impact the efficiency. However, the impact of the tank volume varies depending on the solar radiation profile and the load requirements. Average efficiencies for the seven-day operation can be larger than 6% with a proper selection of the solar collector area and tank volume for an Organic Rankine Cycle with a capacity of about 2.6 kW. Finally, an economic analysis of the system was conducted, and the results were compared with a solar PV + battery system of similar capacity. It is expected that the cost for the analyzed solar-thermal system decreases in the coming years with the increased interest on low temperature applications.

14 SOLAR ENERGY↗

Hybrid-energy approach enabled by heat storage and oxy-combustion to generate electricity with near-zero or negative CO 2 emissions

We assess a hybrid-energy approach that modifies a steam-turbine power plant to use renewable energy sources (electricity, plus options for geothermal and solar heat), plus fossil fuel (natural gas and coal) and/or waste biomass (e.g., Douglas fir woodchips). Heat storage allows heat to be created during periods of excess energy supply and for that heat to be converted to electricity when demanded. Excess electricity, such as from variable renewable energy (VRE), is used to generate oxygen for oxy-combustion furnaces that create very-hot, high-purity CO 2 that heats granular rock beds in insulated vessels. Cool CO 2 leaving the beds is dried, sent to compressors powered by excess VRE electricity, before being sent by pipeline to geologic CO 2 storage. Very-hot CO 2 transfers high-grade heat from storage to the power plant in a closed loop that returns medium-grade heat back to storage, allowing low- and medium-grade renewable-heat sources to be stacked beneath combustion heat, with all heat sources being converted to electricity at the same (high) thermal efficiency. Reliable, on-demand power may be generated with near-zero CO 2 emissions with fossil fuel and with negative CO 2 emissions with waste biomass. Our analyses show that with fossil fuel, up to 35% of gross power can be derived from renewable sources, while for waste biomass, it can be entirely derived from renewable sources. Because our approach has the potential to ensure that grids have a continuous supply of clean energy and because electricity is only generated once, when demanded, it could serve as an efficient alternative to bulk energy storage.

30 DIRECT ENERGY CONVERSION↗