Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “distribution analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

DistOPF: Advanced Solutions for Distribution Optimal Power Flow Analysis - DistOPF v0.2 Documentation

To achieve an affordable and reliable energy system, research on power distribution system is often focused on integration of distributed generators, energy storage solution, EV charging, smart meters, and other advanced assets that may benefit from or require more advanced control and optimization techniques. Despite this focus on advanced distribution system topics, early researchers and grid scientists often start from scratch when developing optimization programs for power distribution systems. This report introduces DistOPF, a Python package that consolidates years of research into a versatile and modular tool. DistOPF provides researchers with essential capabilities to solve distribution system Optimal Power Flow (OPF) problems using standard network models. Additionally, it offers a platform to benchmark both new and existing algorithms against established test systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Titan aerosols - Optical properties and vertical distribution

An analysis of Titan's solar phase variation as a function of wavelength together with the continuum geometric albedo makes it possible to set limits on the real part of the refractive index and on the average particle size of the aerosol component of Titan's atmosphere of between about 1.5 and 2.0 and between 0.20 microns and about 0.35 microns, respectively. If the real part of the refractive index is known the average particle size can be determined to within a few percent, and varies inversely with the real part of the refractive index. Using this information in a two-layer model of a methane-aerosol atmosphere and comparing the result with Titan's visible and near-infrared methane spectrum leads to the conclusion that the top layer of Titan's atmosphere contains 0.01 km atm of methane and 2.5 extinction optical depths of aerosol, while the data are consistent with a bottom layer containing 2.2 km atm of methane and about 7.5 aerosol optical depths for a real part of the refractive index equal to 1.7 and an average particle size of 0.25 microns.

Rages, K.↗

Comparison of mode estimation methods and application in molecular clock analysis

BACKGROUND: Distributions of time estimates in molecular clock studies are sometimes skewed or contain outliers. In those cases, the mode is a better estimator of the overall time of divergence than the mean or median. However, different methods are available for estimating the mode. We compared these methods in simulations to determine their strengths and weaknesses and further assessed their performance when applied to real data sets from a molecular clock study. RESULTS: We found that the half-range mode and robust parametric mode methods have a lower bias than other mode methods under a diversity of conditions. However, the half-range mode suffers from a relatively high variance and the robust parametric mode is more susceptible to bias by outliers. We determined that bootstrapping reduces the variance of both mode estimators. Application of the different methods to real data sets yielded results that were concordant with the simulations. CONCLUSION: Because the half-range mode is a simple and fast method, and produced less bias overall in our simulations, we recommend the bootstrapped version of it as a general-purpose mode estimator and suggest a bootstrap method for obtaining the standard error and 95% confidence interval of the mode.

Evolution, Molecular↗

Transmission and Distribution Real-Time Analysis Software for Monitoring and Control: Design and Simulation Testing

The US electric grid is facing operational, stability, and security challenges. Transmission system operators need some measure of visibility into distribution system renewable generation. Distribution system generation needs to support transmission system voltage. The grid is experiencing an expansion in measurement systems. How to take full advantage of this expansion and defend against attacks, both cyber and physical, poses additional challenges. This paper introduces software designed to meet these challenges. At the center of the software is an Integrated System Model (ISM) that spans from transmission to secondary distribution. The ISM is employed in real-time abnormality detection, voltage stability forecasting, and multi-mode control. The software architecture along with selected analysis modules is presented. Testing results are presented for: 1—attacks on utility infrastructure; 2—energy savings from optimal control; 3—distribution system control response during a low voltage transmission system event; 4—cyber-attacks on PV inverters, where physical inverters are used in hardware-in-the-simulation-loop studies. Contributions of this work include real-time analysis that spans from three-phase transmission through secondary distribution; an approach for detecting abnormalities that employs measurements from three independent measurement systems; and a multi-mode distribution system control that responds to cyber-attacks, physical attacks, equipment failures, and transmission system needs.

14 SOLAR ENERGY↗

Analysis of fission product distribution and composition in the TRISO layers of AGR-2 fuel

The Advanced Gas Reactor Fuel Qualification and Development Program's second irradiation experiment focuses on the performance of fuel particles produced in an industrial-scale coating system. Ongoing post-irradiation examination efforts include exploration of tristructural-isotropic (TRISO)-coated particle fuel in the as-irradiated state and subjected to elevated temperatures to simulate accident conditions (safety testing). Scanning electron microscopy (SEM) analysis with energy dispersive x-ray spectroscopy (EDS) was used to show the distribution of fission products within the TRISO layers. The SEM analysis showed a variation of fission product distribution within the TRISO layers based on irradiation temperature, burnup, individual particle fission product inventory retention, safety testing history and kernel composition. Finally, a key observation is that particles which likely experienced higher temperature showed a greater diversity and distribution of fission products and actinides in the IPyC and SiC layers, implying that temperature is a dominant variable influencing the transport of radionuclides in TRISO particles.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Transonic airfoil and wing design using Navier-Stokes codes

An iterative design method has been implemented into 2D and 3D Navier-Stokes codes for the design of airfoils or wings with given target pressure distributions. The method begins with the analysis of an initial geometry, and obtains the analysis pressure distributions of that geometry. The differences between analysis pressures and target pressures are used to drive geometry changes through the use of a streamline curvature method. This paper describes the procedure that makes the iterative design method work for Navier-Stokes codes. Examples of 2D airfoil design, and 3D wing design are included. It is demonstrated that the method is highly effective for airfoil or wing design at flow conditions where no substantial separation occurs. Problems encountered in the airfoil design with shock induced flow separations are discussed.

Yu, N. J.↗

Validation of Power Distribution Models using Load Flow Analysis in an ADMS Environment

Electric utilities are facing the need for better monitoring, analysis, and control of their distribution systems. An accurate mathematical model is a key to both the development of cutting-edge, scalable model-based algorithms and the assessment of emerging technologies such as distributed energy resources (DER) for grid planning and operation. However, the constantly evolving nature of power distribution systems poses challenges to maintaining accurate models. In this paper, we propose a novel load flow based approach to validate power distribution models. Networked equipment models described according to the Common Information Model (CIM) standard and a measurement model are used to formulate the distribution load flow problem. First, a system admittance matrix (Ybus) is derived from device-level CIM parameters. Next, the operational parameters (dynamic Ybus and nodal injections) are extracted from the measurement model using sensor configuration and equipment state. An iterative power flow method is then used to compute nodal voltages and branch flows that are compared against the measurement data to find any inconsistencies in the networked equipment model. This approach is implemented within GridAPPS-D, an open-source standards-based platform for advanced distribution management system (ADMS) application development, and demonstrated on the IEEE 13-bus, 123-bus, and 8500-node test feeders.

Common information model, model validation, power ↗

Monitoring the long-term performance of organic redox flow battery by a distribution of relaxation time analysis

Organic redox flow batteries hold great promise as an energy storage technology, but their intricate chemistry makes them vulnerable to various degradation mechanisms. Monitoring this degradation is essential for identifying the limiting processes within the cells. Electrochemical impedance spectroscopy (EIS) offers a straightforward, in-situ method for measuring the total resistance of an operating cell. However, to pinpoint the limiting processes during long-term cycling, EIS data must be complemented by other techniques. Distribution of relaxation time (DRT) analysis is particularly effective for differentiating resistance components. Here, in this study, we perform a comprehensive analysis of resistance evolution and the separation of anode and cathode contributions during long-term cycling of a full cell employing 7,8-dihydroxyphenazine-2-sulfonic acid (DHPS) as the anolyte. Separate analyses of the DHPS anolyte and ferri-/ferrocyanide catholyte were conducted using a symmetric cell setup. The relaxation times derived from symmetric cells facilitate the identification of peaks in the DRT profiles from the full cell. Importantly, the DRT profiles indicate a correlation between the evolution of charge transfer resistance and the chemical degradation of DHPS. The methodologies and results outlined in this study offer significant insights for developing diagnostic tools applicable to other types of redox flow batteries.

Distribution of relaxation time↗

Dark energy survey internal consistency tests of the joint cosmological probes analysis with posterior predictive distributions

Beyond ΛCDM, physics or systematic errors may cause subsets of a cosmological data set to appear inconsistent when analysed assuming ΛCDM. Here, we present an application of internal consistency tests to measurements from the Dark Energy Survey Year 1 (DES Y1) joint probes analysis. Our analysis relies on computing the posterior predictive distribution (PPD) for these data under the assumption of ΛCDM. We find that the DES Y1 data have an acceptable goodness of fit to ΛCDM, with a probability of finding a worse fit by random chance of p = 0.046. Using numerical PPD tests, supplemented by graphical checks, we show that most of the data vector appears completely consistent with expectations, although we observe a small tension between large- and small-scale measurements. A small part (roughly 1.5 per cent) of the data vector shows an unusually large departure from expectations; excluding this part of the data has negligible impact on cosmological constraints, but does significantly improve the p-value to 0.10. The methodology developed here will be applied to test the consistency of DES Year 3 joint probes data sets.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Preliminary analysis of the span-distributed-load concept for cargo aircraft design

A simplified computer analysis of the span-distributed-load airplane (in which payload is placed within the wing structure) has shown that the span-distributed-load concept has high potential for application to future air cargo transport design. Significant increases in payload fraction over current wide-bodied freighters are shown for gross weights in excess of 0.5 Gg (1,000,000 lb). A cruise-matching calculation shows that the trend toward higher aspect ratio improves overall efficiency; that is, less thrust and fuel are required. The optimal aspect ratio probably is not determined by structural limitations. Terminal-area constraints and increasing design-payload density, however, tend to limit aspect ratio.

Whitehead, A. H., Jr.↗

Unraveling the convoluted and dynamic interphasial mechanisms on Li metal anode

Accurate understanding of the chemistry of solid-electrolyte interphase (SEI) is key to developing new electrolytes for high-energy batteries using lithium metal (Li-0) anodes(1). SEI is generally believed to be formed by the reactions between Li-0 and electrolyte(2,3). However, our new study shows this is not the whole story. Through synchrotron-based X-ray diffraction and pair distribution function analysis, we reveal a much more convoluted formation mechanism of SEI, which receives considerable contributions from electrolyte, cathode, moisture and native surface species on Li-0, with highly dynamic nature during cycling. Using isotope labelling, we traced the origin of LiH to electrolyte solvent, moisture and a new source: the native surface species (LiOH) on pristine Li-0. When lithium accessibility is very limited as in the case of anode-free cells, LiOH develops into plate-shaped large crystals during cycling. Alternatively, when the lithium source is abundant, as in the case of Li||NMC811 cells, LiOH reacts with Li-0 to form LiH and Li2O. While the desired anion-derived LiF-rich SEI is typically found in the concentrated electrolytes or their derivatives, we found it can also be formed in low-concentration electrolyte via the crosstalk effect, emphasizing the importance of formation cycle protocol and opening up opportunities for low-cost electrolyte development.

Polzin, Bryant J.↗

Robust Distributed State Estimator for Interconnected Transmission and Distribution Networks (Final Report RPPR-1)

This project’s objective is to develop a combined transmission and distribution state estimator which accounts for very large system size and model complexity (by way of distributing the computations) and large number of solar PV units connected to the distribution system on multiple feeders. The project not only provides a robust formulation and solution to this problem but also tests the solution by implementing it on a well-established large utility system. It introduces several improvements with respect to the state of the art in existing state estimation software: (a) The developed state estimator (SE) allows robust and accurate monitoring of bidirectional flows in distribution systems which result due to the distributed energy sources which are not observable and thus not incorporated in generation dispatch; (b) Large utility systems with tens of thousands of transmission buses and hundreds of thousands of distribution nodes are difficult to model as a single integrated system. This shortcoming is addressed by developing a “scalable distributed computational framework” which allows splitting the ultra large system models into several small subsystems and coordinating their solution by a robust and practical state estimation formulation; (c) Measurement errors irrespective of their locations are detected and removed by the developed state estimator. Historically, transmission and distribution systems were analyzed and operated as two independent systems. Given the non-transposed short feeder sections, unevenly loaded phases, strictly radial configuration and unidirectional power flows in the absence of remote generation, distribution system analysis was customized to account for these characteristics. However, some of these assumptions are no longer valid (non-radial configuration, bidirectional power flows) and thus distribution system analysis should be revisited. Furthermore, in the past, the interaction between the transmission and distribution systems was quite passive, where distribution substations were modeled as lumped loads in the transmission system model. With substantial generation injected by renewable generation located in the distribution systems, such modeling will no longer be accurate. The developed state estimator facilitates proper monitoring of the interactions between the transmission and distribution systems and enables smart dispatch of these units which are made observable by the state estimator.

24 POWER TRANSMISSION AND DISTRIBUTION↗

HPCC Methodologies for Structural Design and Analysis on Parallel and Distributed Computing Platforms

In this grant, we have proposed a three-year research effort focused on developing High Performance Computation and Communication (HPCC) methodologies for structural analysis on parallel processors and clusters of workstations, with emphasis on reducing the structural design cycle time. Besides consolidating and further improving the FETI solver technology to address plate and shell structures, we have proposed to tackle the following design related issues: (a) parallel coupling and assembly of independently designed and analyzed three-dimensional substructures with non-matching interfaces, (b) fast and smart parallel re-analysis of a given structure after it has undergone design modifications, (c) parallel evaluation of sensitivity operators (derivatives) for design optimization, and (d) fast parallel analysis of mildly nonlinear structures. While our proposal was accepted, support was provided only for one year.

Farhat, Charbel↗

Scaled Implementation of Smart Charge Management for Electric Vehicles

Smart charge management (SCM) has become a critical strategy for mitigating potential grid impacts and reducing electricity costs for all customers. This study will evaluate the economics of implementing light-duty EV SCM at scale across the United States. This work will enhance distribution system analysis by estimating SCM implementation costs, exploring viable business cases, and developing a framework for national-level applications. The primary methodology involves leveraging detailed grid modeling from a specific service territory and using spatial extrapolation techniques to generalize findings to other regions. The analysis will develop key metrics to quantify the costs and benefits of SCM, including implementation costs relative to strategy and scale, the cost of distribution system upgrades with and without SCM, and the percentage of peak-load reduction. The objective is to produce a comprehensive report and a parameterized framework that enables utilities to self-assess the value of SCM in their own service territories. This will support the development of cost-effective charging strategies, accelerate the energization of new EV chargers, and facilitate the seamless integration of EVs into the nation's power grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Remote Sensing, Uncertainty Quantification, and a Theory of Data Systems; Workshop Report

The purpose of the workshop was to invite statisticians, applied mathematicians, computer scientists, data system architects, experts in remote sensing technology, and Climate and Earth System scientists to review, discuss, and plan research on issues related to large-scale, efficient analysis of distributed data using spatial statistical methods. Our motivation in organizing this event was to catalyze interchange among experts on the fast-emerging problem of analysis of distributed data. As part of SAMSI's 2017-2018 Program on Mathematical and Statistical Methods for Climate and the Earth System, a Working Group on Remote Sensing was established to address statistical and mathematical research problems in the analysis of remote sensing data. The Working Group has five subgroups: 1) Spatial Retrieval Methodology (the so-called \Spatial-X" subgroup); 2) Spatial Analysis for Hyperspectral Data (the so-called \Spatial-Y" subgroup); 3) Emulators for Complex Forward Models; 4) Optimization for Remote Sensing Retrievals; and 5) Theory of Data Systems (ToDS). The ToDS subgroup spent the first half of this academic year formulating a framework in which to consider the joint problem of a) optimizing statistical methods for environments where data are distributed and too large to move to a central location, and b) the design of data system infrastructures within which to implement those statistical methods. To x ideas, the Workshop focused on spatial statistical methods. To date there are many new spatial statistical methods designed with massive data sets in mind, in the literature. However, very few have been implemented for remote sensing data, and none have been implemented in operational settings like those used by NASA and NOAA. A major impediment to their use in these cases is that the data are not only massive, but are stored in different physical locations. These data must be brought together in some way in order to estimate spatial covariance functions, but moving data to a central location for analysis is tedious at best and impossible at worst. Some remote data reduction is almost certainly necessary, but how much? What are the consequences for inference? The fundamental issue underlying these questions is how to navigate the trade-space between costs and uncertainty in the estimates or inferences that are ultimately produced.

Braverman, Amy↗

Cost and Efficiency Analysis for Hybrid AC/DC Distribution System Planning with PV and Battery

Distribution system planning is one of the main tasks for the electric utilities. Cost and energy efficiency are two main concerns in the distribution planning process. In this work, cost and efficiency analyses are conducted for the hybrid AC and DC distribution grids for the planning purposes. The IEEE 34-bus feeder has been applied for the case studies. The investment cost, operation and maintenance cost, replacement cost, etc., have been considered in the life cycle cost analysis. Power losses of both the AC and DC section are calculated with an open source simulation tool, the Open Distribution Simulator Software (OpenDSS). The proposed framework can be applied to quantitatively evaluate the cost and efficiency of hybrid AC and DC distribution grids and help comparing different planning options.

AC/DC hybrid system planning↗