Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “direct electron detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

OBES "One Pager"

We are developing and utilizing photon dichroic and spin resolved techniques to investigate electron correlation in complex systems. These materials include potential spintronic device sources such as Fe/GaAs and f electronic materials such as non-magnetic {delta}-Pu. We are pursuing Double Polarization Photoelectron Dichroism measurements of the Fano Effect, using spin resolving detection in photoelectron spectroscopy, to test the nature of electron correlation in Pu. (See Pubs 2, 4 & 5.) If successful, we will solve the riddle of Pu electronic structure that has remained unresolved for the last 60 years. We are also developing a Bremstrahlung Isochromat Spectroscopy (BIS) capability to permit the direct measurement of the unoccupied electronic structure of Pu, which is another missing piece in the puzzle of Pu electronic structure.

36 MATERIALS SCIENCE↗

Direct determination of lead-210 by liquid-scintillation counting

Soft betas, the internal conversion electrons, and unconverted gamma rays from lead-210 are efficiently detected in a liquid scintillation counting system with efficiency of 97 percent. The counter is interfaced with a multichannel pulse height analyzer. The spectra obtained is stored on paper tape and plotted on an x-y plotter.

Fairman, W. D.↗

Axions and high-energy cosmic rays: can the relic axion density be measured?

In a previous work we investigated the propagation of fast moving charged particles in a spatially constant but slowly time dependent pseudoscalar background, such as the one provided by cold relic axions. The background induces cosmic rays to radiate in the low-energy spectrum. While the energy loss caused by this mechanism on the primary cosmic rays is negligible, we investigate the hypothetical detection of the photons radiated and how they could provide an indirect way of verifying the cosmological relevance of axions. Assuming that the cosmic ray flux is of the form J(E) ∼ E{sup −γ} we find that the energy radiated via this mechanism has a power spectrum k to the power of minus gamma minus 1 over 2 for proton primaries and k to the power of minus gamma over 2 for electron primaries, which dominate for low values of k where the effect is maximized. Unfortunately this radiation is shadowed by the synchrotron radiation background making the observation of this effect very difficult. Yet its detection would constitute direct evidence of the presence of a cold axion background.

79 ASTRONOMY AND ASTROPHYSICS↗

Beyond Contrast Transfer: Spectral SNR as a Finite-Dose Metric for STEM Phase Retrieval

The contrast transfer function (CTF) is widely used to evaluate phase retrieval methods in scanning transmission electron microscopy (STEM), including center-of-mass imaging, parallax imaging, direct ptychography, and iterative ptychography. However, the CTF reflects only the maximum usable signal, neglecting the effects of finite electron fluence and the Poisson-limited nature of detection. As a result, it can significantly overestimate practical performance, especially in low-dose regimes. Here, we employ the spectral signal-to-noise ratio (SSNR), as a finite-dose statistical framework to evaluate the recoverable signal as a function of spatial frequency. Using numerical reconstructions of white-noise objects, we show that center-of-mass, parallax, and direct ptychography exhibit dose-independent SSNRs, with close-form analytic expressions. In contrast, iterative ptychography exhibits a surprising dose dependence: at low fluence, its SSNR converges to that of direct ptychography; at high fluence, it saturates at a value consistent with the maximum detective quantum efficiency predicted by recent quantum Fisher information bounds. The results highlight the limitations of CTF-based evaluation and motivate SSNR as a more accurate, finite-dose metric for assessing STEM phase retrieval methods.

STEM phase retrieval↗

Band offsets of a ruthenium gate on ultrathin high-{kappa} oxide films on silicon

Valence-band and conduction-band edges of ultrathin oxides (SiO{sub 2}, HfO{sub 2}, Hf{sub 0.7}Si{sub 0.3}O{sub 2}, and Al{sub 2}O{sub 3} grown on silicon) and their shifts upon sequential metallization with ruthenium have been measured using synchrotron-radiation-excited x-ray, ultraviolet, and inverse photoemissions. From these techniques, the offsets between the valence-band and conduction-band edges of the oxides, and the ruthenium metal gate Fermi edge have been directly measured. In addition the core levels of the oxides and the ruthenium have been characterized. Upon deposition, Ru remains metallic and no chemical alteration of the underlying oxide gates, or interfacial SiO{sub 2} in the case of the high-{kappa} thin films, can be detected. However a clear shift of the band edges is measured for all samples due to the creation of an interface dipole at the ruthenium-oxide interface. Using the energy gap, the electron affinity of the oxides, and the ruthenium work function that have been directly measured on these samples, the experimental band offsets are compared to those predicted by the induced gap states model.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The MIGDAL experiment: Measuring a rare atomic process to aid the search for dark matter

We present the Migdal In Galactic Dark mAtter expLoration (MIGDAL) experiment aiming at the unambiguous observation and study of the so-called Migdal effect induced by fast-neutron scattering. It is hoped that this elusive atomic process can be exploited to enhance the reach of direct dark matter search experiments to lower masses, but it is still lacking experimental confirmation. Our goal is to detect the predicted atomic electron emission which is thought to accompany nuclear scattering with low, but calculable, probability, by deploying an Optical Time Projection Chamber filled with a low-pressure gas based on CF 4 . Initially, pure CF 4 will be used, and then in mixtures containing other elements employed by leading dark matter search technologies — including noble species, plus Si and Ge. High resolution track images generated by a Gas Electron Multiplier stack, together with timing information from scintillation and ionisation readout, will be used for 3D reconstruction of the characteristic event topology expected for this process — an arrangement of two tracks sharing a common vertex, with one belonging to a Migdal electron and the other to a nuclear recoil. Different energy-loss rate distributions along both tracks will be used as a powerful discrimination tool against background events. In this article we present the design of the experiment, informed by extensive particle and track simulations and detailed estimations of signal and background rates. In pure CF 4 we expect to observe 8.9 (29.3) Migdal events per calendar day of exposure to an intense D–D (D–T) neutron generator beam at the NILE facility located at the Rutherford Appleton Laboratory (UK). With our nominal assumptions, 5σ median discovery significance can be achieved in under one day with either generator.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Porous material neutron detector

A neutron detector employs a porous material layer including pores between nanoparticles. The composition of the nanoparticles is selected to cause emission of electrons upon detection of a neutron. The nanoparticles have a maximum dimension that is in the range from 0.1 micron to 1 millimeter, and can be sintered with pores thereamongst. A passing radiation generates electrons at one or more nanoparticles, some of which are scattered into a pore and directed toward a direction opposite to the applied electrical field. These electrons travel through the pore and collide with additional nanoparticles, which generate more electrons. The electrons are amplified in a cascade reaction that occurs along the pores behind the initial detection point. An electron amplification device may be placed behind the porous material layer to further amplify the electrons exiting the porous material layer.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Precision measurement of Compton scattering in silicon with a skipper CCD for dark matter detection

Experiments aiming to directly detect dark matter through particle recoils can achieve energy thresholds of $\mathcal{O}(1\,\mathrm{eV})$. In this regime, ionization signals from small-angle Compton scatters of environmental $\gamma$-rays constitute a significant background. Monte Carlo simulations used to build background models have not been experimentally validated at these low energies. We report a precision measurement of Compton scattering on silicon atomic shell electrons down to 23$\,$eV. A skipper charge-coupled device (CCD) with single-electron resolution, developed for the DAMIC-M experiment, was exposed to a $^{241}$Am $\gamma$-ray source over several months. Features associated with the silicon K, L$_{1}$, and L$_{2,3}$-shells are clearly identified, and scattering on valence electrons is detected for the first time below 100$\,$eV. We find that the relativistic impulse approximation for Compton scattering, which is implemented in Monte Carlo simulations commonly used by direct detection experiments, does not reproduce the measured spectrum below 0.5$\,$keV. The data are in better agreement with $ab$$initio$ calculations originally developed for X-ray absorption spectroscopy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-Resolution Laser-Induced Graphene. Flexible Electronics beyond the Visible Limit

Laser-induced graphene (LIG) is a multifunctional graphene foam that is commonly direct-written with an infrared laser into a carbon-based precursor material. Here, a visible 405 nm laser is used to directly convert polyimide into LIG. This enabled the formation of LIG with a spatial resolution of ~12 μm and a thickness of <5 μm. The spatial resolution enabled by the relatively smaller focused spot size of the 405 nm laser represents a >60% reduction in LIG feature sizes reported in prior publications. This process occurs in situ in an SEM chamber, thus allowing direct observation of LIG formation. The reduced size of the LIG features enables the direct-write formation of flexible electronics that are not visible to the unaided eye. A humidity sensor is demonstrated which could detect human breath with a response time of 250 ms. With the growing interest in LIG for flexible electronics and sensors, finer features can greatly expand its utility.

36 MATERIALS SCIENCE↗

Performance of a Quintuple-GEM Based RICHDetector Prototype

Cerenkov technology is often the optimal choice for particle identification in high energy particle collision applications. Typically, the most challenging regime is at high pseudorapidity (forward) where particle identification must perform well at high laboratory momenta. For the upcoming electron ion collider (EIC), the physics goals require hadron (π, K, p) identification up to ~50 GeV/c. In this region Cerenkov ring-imaging (RICH) is the most viable solution. The speed of light in a radiator medium is inversely proportional to the refractive index. Hence, for particle identification (PID) reaching out to high momenta a small index of refraction is required. Unfortunately, the lowest indices of refraction also result in the lowest light yield ([(dNγ)/dx] ∝ sin2(θC)) driving up the radiator length and thereby the overall detector cost. In this paper we report on a successful test of a compact RICH detector (1 meter radiator) capable of delivering in excess of 10 photoelectrons per ring with a low index radiator gas (CF4). The detector concept is a natural extension of the PHENIX hadron-blind detector (HBD) achieved by adding focusing capability at low wavelength and adequate gain for high efficiency detection of single-electron induced avalanches. Our results indicate that this technology is indeed a viable choice in the forward direction of the EIC. The setup and results are described within.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Observation of a current-driven plasma instability at the outer zone-plasma sheet boundary.

Several spacecraft experimenters have reported on the detection of large temporal variations in trapped electron fluxes near L = 5 to 6 at midlatitudes in the night hemisphere. In this report we describe in detail the particle, wave, and field changes measured when Ogo 5 traversed an outer-zone trapping boundary of this type on September 7, 1968. It is shown that thermal proton concentrations and E greater than 50-keV electron fluxes abruptly decreased when electrons with (1-4) keV mean energy were detected. It is also shown that currents flowed along the average geomagnetic field direction near the plasma boundaries and that these were accompanied by intense VLF electrostatic waves. It is proposed that turbulent resistivity produced by current-driven plasma instabilities allows parallel dc electric fields to develop along this boundary.

Scarf, F. L.↗

Direct detection optical intersatellite link at 220 Mbps using AlGaAs laser diode and silicon APD with 4-ary PPM signaling

A newly developed 220 Mbps free-space 4-ary pulse position modulation (PPM) direct detection optical communication system is described. High speed GaAs integrated circuits were used to construct the PPM encoder and receiver electronic circuits. Both PPM slot and word timing recovery were provided in the PPM receiver. The optical transmitter consisted of an AlGaAs laser diode (Mitsubishi ML5702A, lambda=821nm) and a high speed driver unit. The photodetector consisted of a silicon avalanche photodiode (APD) (RCA30902S) preceded by an optical interference filter (delta lambda=10nm). Preliminary tests showed that the self-synchronized PPM receiver could achieve a receiver bit error rate of less than 10(exp -6) at 25 nW average received optical signal power or 360 photons per transmitted information bit. The relatively poor receiver sensitivity was believed to be caused by the insufficient electronic bandwidth of the APD preamplifier and the poor linearity of the preamplifier high frequency response.

Sun, Xiaoli↗

The Large-Area Time-Of-Flight (TOF) Upgrade for the STAR Detector

The STAR experiment at RHIC concentrates on the tracking of charged hadrons via ionization in gas- and silicon-based detectors, and the detection of electrons and photons via calorimetry, in a wide and azimuthally complete acceptance that's unique at RHIC. STAR's ability to directly identify the tracked charged hadrons is however limited to low momenta. Approximately half of the charged particles in the event at higher momenta cannot be directly identified, which hampers the physics reach of STAR in a number of key areas. To address this blind spot, STAR is presently constructing a large-area ({approx}50 m{sup 2}) Time-Of-Flight (TOF) system. This system is based on Multi-gap Resistive Plate Chambers (MRPCs). Prototype TOF systems based on this technology were operated in STAR during RHIC Runs 3 through 6, and the first 5 final-system trays were operated in the recent RHIC Run 8. A new 'start detector' for this system has also been constructed and operated in STAR. The performance of these detectors in STAR, and an update on the status of the construction of the full system, is discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Direct Signal-to-Noise Quality Comparison between an Electronic and Conventional Stethoscope aboard the International Space Station

Introduction: Evaluation of heart, lung, and bowel sounds is routinely performed with the use of a stethoscope to help detect a broad range of medical conditions. Stethoscope acquired information is even more valuable in a resource limited environments such as the International Space Station (ISS) where additional testing is not available. The high ambient noise level aboard the ISS poses a specific challenge to auscultation by stethoscope. An electronic stethoscope's ambient noise‐reduction, greater sound amplification, recording capabilities, and sound visualization software may be an advantage to a conventional stethoscope in this environment. Methods: A single operator rated signal‐to‐noise quality from a conventional stethoscope (Littman 2218BE) and an electronic stethoscope (Litmann 3200). Borborygmi, pulmonic, and cardiac sound quality was ranked with both stethoscopes. Signal‐to‐noise rankings were preformed on a 1 to 10 subjective scale with 1 being inaudible, 6 the expected quality in an emergency department, 8 the expected quality in a clinic, and 10 the clearest possible quality. Testing took place in the Japanese Pressurized Module (JPM), Unity (Node 2), Destiny (US Lab), Tranquility (Node 3), and the Cupola of the International Space Station. All examinations were conducted at a single point in time. Results: The electronic stethoscope's performance ranked higher than the conventional stethoscope for each body sound in all modules tested. The electronic stethoscope's sound quality was rated between 7 and 10 in all modules tested. In comparison, the traditional stethoscope's sound quality was rated between 4 and 7. The signal to noise ratio of borborygmi showed the biggest difference between stethoscopes. In the modules tested, the auscultation of borborygmi was rated between 5 and 7 by the conventional stethoscope and consistently 10 by the electronic stethoscope. Discussion: This stethoscope comparison was limited to a single operator. However, we believe the results are noteworthy. The electronic stethoscope out preformed the traditional stethoscope in each direct comparison. Consideration should be made to incorporate an electronic stethoscope into current and future space vehicle medical kits.

Marshburn, Thomas↗

Observing a light dark matter beam with neutrino experiments

We consider the sensitivity of fixed-target neutrino experiments at the luminosity frontier to light stable states, such as those present in models of MeV-scale dark matter. To ensure the correct thermal relic abundance, such states must annihilate via light mediators, which in turn provide an access portal for direct production in colliders or fixed targets. Indeed, this framework endows the neutrino beams produced at fixed-target facilities with a companion 'dark matter beam', which may be detected via an excess of elastic scattering events off electrons or nuclei in the (near-)detector. We study the high-luminosity proton fixed-target experiments at LSND and MiniBooNE, and determine that the ensuing sensitivity to light dark matter generally surpasses that of other direct probes. For scenarios with a kinetically-mixed U(1){sup '} vector mediator of mass m{sub V}, we find that a large volume of parameter space is excluded for m{sub DM}{approx}1-5 MeV, covering vector masses 2m{sub DM} < or approx. m{sub V} < or approx. m{sub {eta}} and a range of kinetic mixing parameters reaching as low as {kappa}{approx}10{sup -5}. The corresponding MeV-scale dark matter scenarios motivated by an explanation of the galactic 511 keV line are thus strongly constrained.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Detection of traveling ionospheric disturbances induced by atmospheric gravity waves using the global positioning system

Natural and man-made events like earthquakes and nuclear explosions launch atmospheric gravity waves (AGW) into the atmosphere. Since the particle density decreases exponentially with height, the gravity waves increase exponentially in amplitude as they propagate toward the upper atmosphere and ionosphere. As atmospheric gravity waves approach the ionospheric heights, the neutral particles carried by gravity waves collide with electrons and ions, setting these particles in motion. This motion of charged particles manifests itself by wave-like fluctuations and disturbances that are known as traveling ionospheric disturbances (TID). The perturbation in the total electron content due to TID's is derived analytically from first principles. Using the tilted dipole magnetic field approximation and a Chapman layer distribution for the electron density, the variations of the total electron content versus the line-of-sight direction are numerically analyzed. The temporal variation associated with the total electron content measurements due to AGW's can be used as a means of detecting characteristics of the gravity waves. As an example, detection of tsunami generated earthquakes from their associated atmospheric gravity waves using the Global Positioning System is simulated.

Bassiri, Sassan↗

Linear and third- and fifth-order nonlinear spectroscopies of a charge transfer system coupled to an underdamped vibration

We study hole, electron, and exciton transports in a charge transfer system in the presence of underdamped vibrational motion. We analyze the signature of these processes in the linear and third-, and fifth-order nonlinear electronic spectra. Calculations are performed with a numerically exact hierarchical equations of motion method for an underdamped Brownian oscillator spectral density. We find that combining electron, hole, and exciton transfers can lead to non-trivial spectra with more structure than with excitonic coupling alone. Traces taken during the waiting time of a two-dimensional (2D) spectrum are dominated by vibrational motion and do not reflect the electron, hole, and exciton dynamics directly. We find that the fifth-order nonlinear response is particularly sensitive to the charge transfer process. While third-order 2D spectroscopy detects the correlation between two coherences, fifth-order 2D spectroscopy (2D population spectroscopy) is here designed to detect correlations between the excited states during two different time periods.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Increased Photochemical Efficiency in Cyanobacteria via an Engineered Sucrose Sink

In plants, a limited capacity to In plants, a limited capacity to utilize or export the end-products of the Calvin–Benson cycle (CB) from photosynthetically active source cells to non-photosynthetic sink cells can result in reduced carbon capture and photosynthetic electron transport (PET), and lowered photochemical efficiency. The down-regulation of photosynthesis caused by reduced capacity to utilize photosynthate has been termed ‘sink limitation’. Recently, several cyanobacterial and algal strains engineered to overproduce target metabolites have exhibited increased photochemistry, suggesting that possible source–sink regulatory mechanisms may be involved. Here, we directly examined photochemical properties following induction of a heterologous sucrose ‘sink’ in the unicellular cyanobacterium Synechococcus elongatus PCC 7942. We show that total photochemistry increases proportionally to the experimentally controlled rate of sucrose export. Importantly, the quantum yield of PSII (ΦII) increases in response to sucrose export while the PET chain becomes more oxidized from less PSI acceptor-side limitation, suggesting increased CB activity and a decrease in sink limitation. Enhanced photosynthetic activity and linear electron flow are detectable within hours of induction of the heterologous sink and are independent of pigmentation alterations or the ionic/osmotic effects of the induction system. These observations provide direct evidence that secretion of heterologous carbon bioproducts can be used as an alternative approach to improve photosynthetic efficiency, presumably by by-passing sink limitation. Our results also suggest that engineered microalgal production strains are valuable alternative models for examining photosynthetic sink limitation because they enable greater control and monitoring of metabolite fluxes relative to plants.

59 BASIC BIOLOGICAL SCIENCES↗