High Dose and Dose Rate 60 Co γ-Irradiation of High-Density Polyethylene
We have irradiated high-density polyethylene ribbons and cylinders to ~200 kGy at a dose rate of ~5 kGy day -1 , using a 60 Co source. The radiolytically-generated gas consists almost entirely of H 2 . Based on the time- and dose-dependence of the outgassing, we have determined the radiation- chemical yield for the evolved H 2 , as well as the diffusion coefficient of H 2 in HDPE. We find that the evolved gas yield G evolved depends on the interplay of sample geometry, experimental timescale, and the diffusion coefficient of H 2 in HDPE. When these factors facilitate completion of diffusion prior to gas quantification, such as for sub-mm-thickness ribbons, we measure a time- and dose-invariant value of G evolved = 0.0076 cm 3 std. H 2 J -1 that is in agreement with literature reports. When sample geometry and experiment timescale do not permit completion of diffusion, we measure a time- and dose-dependent value of G evolved . We have developed a model for the transient outgassing behavior of the cylinders, and fitted it to the experimental data. Based on these fits, we estimate a room-temperature diffusivity of D H 2 /HDPE ≈ 1.67 ± 0.12 x 10 -6 cm 2 s -1 for H 2 in HDPE, in good agreement with literature values. At present, the effects of dose rate and γ-photon energy on HDPE gas yield are not known and require further investigation.