Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “different dimensions”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Flame Spread Across Liquids: Experimental Results

The goal of our research on flame spread across a pool of liquid fuel is the quantitative identification of the mechanisms that control the rate and nature of flame spread when the initial temperature of the liquid pool is below the fuel's flash point temperature. Besides numerous experiments in drop towers and 1 g laboratories, we have flown five microgravity (mu-g) experiments on sounding rockets. As described in earlier papers, the first three flights examined the effect of forced opposed airflow over a 2.5 cm deep x 2 cm wide x 30 cm long pool of 1-butanol in mu-g. It was found that the flame spread is much slower and steadier than in 1 g where flame spread has a pulsating character. It was speculated that the flame spread in mu-g resembled the character of pseudo-uniform spread in 1 g; Ito et al later confirmed this conclusively in 1 g experiments. Much of the mu-g flame is also farther from the surface, dimmer, and with less soot, when compared to the 1 g flame. Three-dimensional liquid-phase flow patterns that control the liquid preheating were discovered in both 1 g and mu-g. Our numerical model, restricted to two dimensions, had predicted faster, pulsating flame spread in mu-g for opposed airflow. In examining the differences in the dimensionality of the model and experiment, it was noted that the experiment allowed gas expansion in the lateral direction (across the width of the pool), for which the model could not account. Such lateral expansion could reduce the expansion in the forward and upward directions. Because only these latter directions could be modeled, it was decided to artificially reduce the gas thermal expansion in the predictions. When this was done, satisfactory agreement could be obtained between the predicted and observed spread rates and the steadiness of the spread in microgravity. In 1 g, however, the predicted flame spread character also changed to pseudo-uniform, which disagreed with our 1 g experiments where the spread is pulsating. It was then speculated that gas-phase buoyant flow might oppose the lateral gas expansion, so that the 1 g experiments retained their pulsating flame spread character. If this speculation was valid, a difference in lateral gas expansion should be observable when comparing 1 g and mu-g experiments. Specifically, it was anticipated that greater flow divergence caused by lateral expansion would be measured in mu-g in the absence of a buoyant flow directed towards the flame.

Ross, H. D.↗

Hypergravity Loading the Cultured Osteoblasts: Modeling and Experimental Analysis of Cellular Morphology and the Cytoskeleton

Bone forming cells, osteoblasts, respond to various mechanical forces, including mechanical strain and fluid-induced shear stress. This study examined whether osteoblasts detect changes in gravity as a mechanical force, as assessed by cellular morphology and dimensions of the cytoskeletal network. We used modeling to evaluate how gravity influences cell morphology given theoretical differences in densities between the surrounding medium, cytoplasm, and nucleus. A mechanical model was built based on analysis of axisymmetric shell structures (Fast4 software) to study the effects of 10 times gravity (10G) on cell height. The model indicated 0.02% decrease in overall cell height when the medium was 10% denser than the nucleus or cytoplasm, 5.9 x 10(exp-5)% decrease when the nucleus was 10% denser than the cytoplasm or medium, and 1.3 x 10(exp-5)% decrease when the cell cytoplasm was 10% denser than the nucleus or medium. To experimentally evaluate the influence of gravity, cultured primary fetal rat osteoblasts were grown to near confluence and centrifuged at 10G for 3 hours. Actin, microtubules, and nuclei were fluorescently labeled and analyzed by confocal microscopy to determine overall microtubule and actin network height. Centrifugation led to an apparent reduction in height of both the microtubule (-16%) and the actin (-20%) networks relative to stationary controls. Thus, both modeling and experiments indicate that hypergravity reduces the height of the osteoblast cell layer and their microtubule and actin networks. This combination of modeling and experimental analyses will help us to better understand the mechanical loading of osteoblasts.

Searby, N. D.↗

Vasomotor tone does not affect perfusion heterogeneity and gas exchange in normal primate lungs during normoxia

To determine whether vasoregulation is an important cause of pulmonary perfusion heterogeneity, we measured regional blood flow and gas exchange before and after giving prostacyclin (PGI(2)) to baboons. Four animals were anesthetized with ketamine and mechanically ventilated. Fluorescent microspheres were used to mark regional perfusion before and after PGI(2) infusion. The lungs were subsequently excised, dried inflated, and diced into approximately 2-cm(3) pieces (n = 1,208-1,629 per animal) with the spatial coordinates recorded for each piece. Blood flow to each piece was determined for each condition from the fluorescent signals. Blood flow heterogeneity did not change with PGI(2) infusion. Two other measures of spatial blood flow distribution, the fractal dimension and the spatial correlation, did not change with PGI(2) infusion. Alveolar-arterial O(2) differences did not change with PGI(2) infusion. We conclude that, in normal primate lungs during normoxia, vasomotor tone is not a significant cause of perfusion heterogeneity. Despite the heterogeneous distribution of blood flow, active regulation of regional perfusion is not required for efficient gas exchange.

Non-NASA Center↗

Mechanosensitive channels in bacteria as membrane tension reporters

The purpose of this short review is to discuss recent data on the molecular structure and mechanism of gating of MscL, a mechanosensitive channel of large conductance from Escherichia coli. MscL is the first isolated molecule shown to convert mechanical stress of the membrane into a simple response, the opening of a large aqueous pore. The functional complex appears to be a stable homo-pentamer of 15-kDa subunits, the gating transitions in which are driven by stretch forces conveyed through the lipid bilayer. We have measured the open probability of MscL and the kinetics of transitions as a function of membrane tension. The parameters extracted from the single-channel current recordings and dose-response curves such as the energy difference between the closed, open, and intermediate conducting states, and the transition-related changes in protein dimensions suggest a large conformational rearrangement of the channel complex. The estimations show that in native conditions MscL openings could be driven primarily by forces of osmotic nature. The thermodynamic and spatial parameters reasonably correlate with the available data on the structure of a single MscL subunit and multimeric organization of the complex. Combined with the functional analysis of mutations, these data give grounds to hypotheses on the nature of the channel mechanosensitivity.

Review↗

GENOA-PFA: Progressive Fracture in Composites Simulated Computationally

GENOA-PFA is a commercial version of the Composite Durability Structural Analysis (CODSTRAN) computer program that simulates the progression of damage ultimately leading to fracture in polymer-matrix-composite (PMC) material structures under various loading and environmental conditions. GENOA-PFA offers several capabilities not available in other programs developed for this purpose, making it preferable for use in analyzing the durability and damage tolerance of complex PMC structures in which the fiber reinforcements occur in two- and three-dimensional weaves and braids. GENOA-PFA implements a progressive-fracture methodology based on the idea that a structure fails when flaws that may initially be small (even microscopic) grow and/or coalesce to a critical dimension where the structure no longer has an adequate safety margin to avoid catastrophic global fracture. Damage is considered to progress through five stages: (1) initiation, (2) growth, (3) accumulation (coalescence of propagating flaws), (4) stable propagation (up to the critical dimension), and (5) unstable or very rapid propagation (beyond the critical dimension) to catastrophic failure. The computational simulation of progressive failure involves formal procedures for identifying the five different stages of damage and for relating the amount of damage at each stage to the overall behavior of the deteriorating structure. In GENOA-PFA, mathematical modeling of the composite physical behavior involves an integration of simulations at multiple, hierarchical scales ranging from the macroscopic (lamina, laminate, and structure) to the microscopic (fiber, matrix, and fiber/matrix interface), as shown in the figure. The code includes algorithms to simulate the progression of damage from various source defects, including (1) through-the-thickness cracks and (2) voids with edge, pocket, internal, or mixed-mode delaminations.

Murthy, Pappu L. N.↗

Qualification and Reliability for MEMS and IC Packages

Advanced IC electronic packages are moving toward miniaturization from two key different approaches, front and back-end processes, each with their own challenges. Successful use of more of the back-end process front-end, e.g. microelectromechanical systems (MEMS) Wafer Level Package (WLP), enable reducing size and cost. Use of direct flip chip die is the most efficient approach if and when the issues of know good die and board/assembly are resolved. Wafer level package solve the issue of known good die by enabling package test, but it has its own limitation, e.g., the I/O limitation, additional cost, and reliability. From the back-end approach, system-in-a-package (SIAP/SIP) development is a response to an increasing demand for package and die integration of different functions into one unit to reduce size and cost and improve functionality. MEMS add another challenging dimension to electronic packaging since they include moving mechanical elements. Conventional qualification and reliability need to be modified and expanded in most cases in order to detect new unknown failures. This paper will review four standards that already released or being developed that specifically address the issues on qualification and reliability of assembled packages. Exposures to thermal cycles, monotonic bend test, mechanical shock and drop are covered in these specifications. Finally, mechanical and thermal cycle qualification data generated for MEMS accelerometer will be presented. The MEMS was an element of an inertial measurement unit (IMU) qualified for NASA Mars Exploration Rovers (MERs), Spirit and Opportunity that successfully is currently roaring the Martian surface

inertial measurement unit↗

Detection and Height Measurement of Tenuous Clouds and Blowing Snow in ICESat-2 ATLAS Data

Tenuous atmospheric layers, such as high, thin cirrus clouds and blowing snow over Antarctica, play an important role in the climate system, affecting energy fluxes between the Earth and the atmosphere. Our knowledge of the structure of the atmosphere is largely derived from atmospheric satellite measurements. Yet tenuous layers can be hard to detect in satellite lidar data, especially in daylight data characterized by high solar background. In this study, we introduce an approach to detect tenuous atmospheric layers in the atmospheric lidar measurements of NASA's ICESat-2. The density-dimension algorithm for ICESat-2 atmospheric data (DDA-atmos) identifies atmospheric layers while automatically adapting to different background conditions of night, twilight, and daylight data. This capability, demonstrated for tenuous clouds and blowing snow, offers a data-based solution to an important climate modeling problem. Atmospheric layer boundaries, detection confidence, and density fields resultant from the DDA-atmos are reported in ICESat-2 atmospheric data product ATL09.

Ute Herzfeld↗

Coaxial tube array space transmission line characterization

The coaxial tube array tether/transmission line used to connect an SP-100 nuclear power system to the space station was characterized over the range of reactor-to-platform separation distances of 1 to 10 km. Characterization was done with respect to array performance, physical dimensions and masses. Using a fixed design procedure, a family of designs was generated for the same power level (300 kWe), power loss (1.5 percent), and meteoroid survival probability (99.5 percent over 10 yr). To differentiate between vacuum insulated and gas insulated lines, two different maximum values of the E field were considered: 20 kV/cm (appropriate to vacuum insulation) and 50 kV/cm (compressed SF6). Core conductor, tube, bumper, standoff, spacer and bumper support dimensions, and masses were also calculated. The results of the characterization show mainly how transmission line size and mass scale with reactor-to-platform separation distance.

Switzer, Colleen A.↗

Coaxial tube array space transmission line characterization

The coaxial tube array tether/transmission line used to connect an SP-100 nuclear power system to the space station was characterized over the range of reactor-to-platform separation distances of 1 to 10 km. Characterization was done with respect to array performance, physical dimensions and masses. Using a fixed design procedure, a family of designs was generated for the same power level (300 kWe), power loss (1.5 percent), and meteoroid survival probability (99.5 percent over 10 yr). To differentiate between vacuum insulated and gas insulated lines, two different maximum values of the E field were considered: 20 kV/cm (appropriate to vacuum insulation) and 50 kV/cm (compressed SF6). Core conductor, tube, bumper, standoff, spacer and bumper support dimensions, and masses were also calculated. The results of the characterization show mainly how transmission line size and mass scale with reactor-to-platform separation distance.

Switzer, Colleen A.↗

Fractal dimension in nonhyperbolic chaotic scattering

In chaotic scattering there is a Cantor set of input-variable values of zero Lebesgue measure (i.e., zero total length) on which the scattering function is singular. For cases where the dynamics leading to chaotic scattering is nonhyperbolic (e.g., there are Kolmogorov-Arnol'd-Moser tori), the nature of this singular set is fundamentally different from that in the hyperbolic case. In particular, for the nonhyperbolic case, although the singular set has zero total length, strong evidence is presented to show that its fractal dimension is 1.

Lau, Yun-Tung↗

An approximate Kalman filter for ocean data assimilation: An example with an idealized Gulf Stream model

A practical method of data assimilation for use with large, nonlinear, ocean general circulation models is explored. A Kalman filter based on approximation of the state error covariance matrix is presented, employing a reduction of the effective model dimension, the error's asymptotic steady state limit, and a time-invariant linearization of the dynamic model for the error integration. The approximations lead to dramatic computational savings in applying estimation theory to large complex systems. We examine the utility of the approximate filter in assimilating different measurement types using a twin experiment of an idealized Gulf Stream. A nonlinear primitive equation model of an unstable east-west jet is studied with a state dimension exceeding 170,000 elements. Assimilation of various pseudomeasurements are examined, including velocity, density, and volume transport at localized arrays and realistic distributions of satellite altimetry and acoustic tomography observations. Results are compared in terms of their effects on the accuracies of the estimation. The approximate filter is shown to outperform an empirical nudging scheme used in a previous study. The examples demonstrate that useful approximate estimation errors can be computed in a practical manner for general circulation models.

Fukumori, Ichiro↗

Application of a novel finite difference method to dynamic crack problems

A versatile finite difference method (HEMP and HEMP 3D computer programs) was developed originally for solving dynamic problems in continuum mechanics. It was extended to analyze the stress field around cracks in a solid with finite geometry subjected to dynamic loads and to simulate numerically the dynamic fracture phenomena with success. This method is an explicit finite difference method applied to the Lagrangian formulation of the equations of continuum mechanics in two and three space dimensions and time. The calculational grid moves with the material and in this way it gives a more detailed description of the physics of the problem than the Eulerian formulation.

Chen, Y. M.↗

Parallel, iterative solution of sparse linear systems: Models and architectures

A model of a general class of asynchronous, iterative solution methods for linear systems is developed. In the model, the system is solved by creating several cooperating tasks that each compute a portion of the solution vector. A data transfer model predicting both the probability that data must be transferred between two tasks and the amount of data to be transferred is presented. This model is used to derive an execution time model for predicting parallel execution time and an optimal number of tasks given the dimension and sparsity of the coefficient matrix and the costs of computation, synchronization, and communication. The suitability of different parallel architectures for solving randomly sparse linear systems is discussed. Based on the complexity of task scheduling, one parallel architecture, based on a broadcast bus, is presented and analyzed.

Reed, D. A.↗

Parallel, iterative solution of sparse linear systems - Models and architectures

Solving large, sparse, linear systems of equations is a fundamental problem in large scale scientific and engineering computation. A model of a general class of asynchronous, iterative solution methods for linear systems is developed. In the model, the system is solved by creating several cooperating tasks that each compute a portion of the solution vector. A data transfer model predicting both the probability that data must be transferred between two tasks and the amount of data to be transferred is presented. This model is used to derive an execution time model for predicting parallel execution time and an optimal number of tasks given the dimension and sparsity of the coefficient matrix and the costs of computation, synchronization, and communication. The suitability of different parallel architectures for solving randomly sparse linear systems is discussed. Based on the complexity of task scheduling, one parallel architecture, based on a broadcast bus, is presented and analyzed.

Reed, D. A.↗

Relaxation algorithms for the Euler equations

The alternating direction implicit central-difference scheme algorithms may be replaced by successive-line-relaxation (SLR) procedures that are stable in three dimensions. Several Beamand Warming-type codes are presently modified on the basis of SLR solution procedures in order to compute the flows over a cylinder, a NACA-0012 airfoil, and a shock wave reflecting off a plate. Since the codes are written in a 'delta form', the implementation of relaxation procedures that rely only on the corrections is relatively easy; the steady state residual computation and any artificial viscosity terms may be left unchanged.

Wornom, S. F.↗

The Effect of Solution Conditions on the Nucleation Kinetics of Tetragonal Lysozyme Crystals

An understanding of protein crystal nucleation rates and the effect of solution conditions upon them, is fundamental to the preparation of protein crystals of the desired size and shape for X-ray diffraction analysis. The ability to predict the effect of supersaturation, temperature, pH and precipitant concentration on the number and size of crystals formed is of great benefit in the pursuit of protein structure analysis. In this study we experimentally examine the effect of supersaturation, temperature, pH and sodium chloride concentration on the nucleation rate of tetragonal chicken egg white lysozyme crystals. In order to do this batch crystallization plates were prepared at given solution concentrations and incubated at three different temperatures over the period of one week. The number of crystals per well with their size and dimensions were recorded and correlated against solution conditions. Duplicate experiments indicate the reproducibility of the technique. Although it is well known that crystal numbers increase with increasing supersaturation, large changes in crystal number were also correlated against solution conditions of temperature, pH and salt concentration over the same supersaturation ranges. Analysis of these results enhance our understanding of the effect of solution conditions such as the dramatic effect that small changes in charge and ionic strength can have on the number of tetragonal lysozyme crystals that form and grow in solution.

Judge, Russell A.↗

Predictors of Behavior and Performance in Extreme Environments: The Antarctic Space Analogue Program

To determine which, if any, characteristics should be incorporated into a select-in approach to screening personnel for long-duration spaceflight, we examined the influence of crewmember social/ demographic characteristics, personality traits, interpersonal needs, and characteristics of station physical environments on performance measures in 657 American men who spent an austral winter in Antarctica between 1963 and 1974. During screening, subjects completed a Personal History Questionnaire which obtained information on social and demographic characteristics, the Deep Freeze Opinion Survey which assessed 5 different personality traits, and the Fundamental Interpersonal Relations Orientation-Behavior (FIRO-B) Scale which measured 6 dimensions of interpersonal needs. Station environment included measures of crew size and severity of physical environment. Performance was assessed on the basis of combined peer-supervisor evaluations of overall performance, peer nominations of fellow crewmembers who made ideal winter-over candidates, and self-reported depressive symptoms. Social/demographic characteristics, personality traits, interpersonal needs, and characteristics of station environments collectively accounted for 9-17% of the variance in performance measures. The following characteristics were significant independent predictors of more than one performance measure: military service, low levels of neuroticism, extraversion and conscientiousness, and a low desire for affection from others. These results represent an important first step in the development of select-in criteria for personnel on long-duration missions in space and other extreme environments. These criteria must take into consideration the characteristics of the environment and the limitations they place on meeting needs for interpersonal relations and task performance, as well as the characteristics of the individuals and groups who live and work in these environments.

Palinkas, Lawrence A.↗

Mars Immunoassay Life Detection Instrument (MILDI)

The direct detection of organic biomarkers for living or fossil microbes on Mars by an in situ instrument is a worthy goal for future lander missions. We have proposed an instrument based on immunological reactions to specific antibodies to cause activation of fluorescent stains. Antibodies are raised or acquired to a variety of general and specific substances that might be in Mars soil. These antibodies are then combined with various fluorescent stains and applied to small numbered spots on a small (two to three centimeters) test plate where they become firmly attached after drying. On Mars, a sample of soil from a trench or drill core is extracted with water and/or an organic solvent that is then applied to the test plate. Any substance, which has an antibody on the test plate, will react with its antibody and activate its fluorescent stain. A small ultraviolet light source will illuminate the test plate, which is observed with a small CCD camera. The numbered spots that fluoresce indicate the presence of the tested-for substance, and the intensity indicates relative amounts. The entire instrument can be quite small and light, on the order of ten cm in each dimension. A possible choice for light source may be small UV lasers at several wavelengths. Up to 1000 different sample spots can be placed on a plate 3 cm on a side, but a more practical number might be 100. Each antibody can have a redundant position for independent verification of reaction. Some of the wells or spots can contain simply standard fluorescent stains used to detect live cells, dead cells, DNA, etc. These the stains in these spots may be directly activated; no antibodies are necessary.

McKay, David↗