Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “device operation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Influential Factors for Liquid Acquisition Device Screen Selection for Cryogenic Propulsion Systems

This paper presents the influential factors which govern screen selection for liquid acquisition devices (LADs) operating in microgravity conditions for future in-space cryogenic propulsion engines and cryogenic propellant depots. Space flight requirements, which include mass flow rate, acceleration level and direction, and thermal environment, dictate screen selection for a particular mission. The five influential factors include bubble point pressure, flow-through-screen pressure drop, wicking rate, screen compliance, and material compatibility. Governing equations and analytical models for these parameters are developed from first principles. A comprehensive survey of the historical data on coarser LAD meshes over four decades of work is conducted, and liquid hydrogen data for finer Dutch Twill meshes (325 x 2300, 450 x 2750, 510 x 3600) from recently concluded experiments is also presented to validate analytical models. Each of these parameters is measurable from ground based tests, making it facile to predict flight system performance. Therefore analytical models in this paper will be valuable for future LAD designs for both cryogenic and storable propulsion systems. Additionally, analysis will be given on the impact of the factors on liquid hydrogen systems.

Fuel Depot↗

Proof-of-Concept Experiments on a Gallium-Based Ignitron for Pulsed Power Applications

Ignitrons are electrical switching devices that operate at switching times that are on the order of microseconds, can conduct high currents of thousands of amps, and are capable of holding off tens of thousands of volts between pulses. They consist of a liquid metal pool within an evacuated tube that serves both the cathode and the source of atoms and electrons for an arc discharge. Facing the liquid metal pool is an anode suspended above the cathode, with a smaller ignitor electrode tip located just above the surface of the cathode. The ignitron can be charged to significant voltages, with a potential difference of thousands of volts between anode and cathode. When an ignition pulse is delivered from the ignitor electrode to the cathode, a small amount of the liquid metal is vaporized and subsequently ionized, with the high voltage between the anode and cathode causing the gas to bridge the gap between the two electrodes. The electrons and ions move rapidly towards the anode and cathode, respectively, with the ions liberating still more atoms from the liquid metal cathode surface as a high-current plasma arc discharge is rapidly established. This arc continues in a self-sustaining fashion until the potential difference between the anode and cathode drops below some critical value. Ignitrons have been used in a variety of pulsed power applications, including the railroad industry, industrial chemical processing, and high-power arc welding. In addition, they might prove useful in terrestrial power grid applications, serving as high-current fault switches, quickly shunting dangerous high-current or high-voltage spikes safely to ground. The motivation for this work stemmed from the fact that high-power, high-reliability, pulsed power devices like the ignitron have been used for ground testing in-space pulsed electric thruster technologies, and the continued use of ignitrons could prove advantageous to the future development and testing of such thrusters. Previous ignitron designs have used mercury as the liquid metal cathode, owing to its presence as a liquid at room temperatures and a vapor pressure of 10 Pa (75 mtorr) at room temperature. While these are favorable properties, there are obvious environmental and personal safety concerns with the storage, handling, and use of mercury and its compounds. The purpose of the present work was to fabricate and test an ignitron that used as its cathode an alternate liquid metal that was safe to handle and store. To that end, an ignitron test article that used liquid gallium as the cathode material was developed and tested. Gallium is a metal that has a melting temperature of 29.76 C, which is slightly above room temperature, and a boiling point of over 2,300 C at atmospheric pressure. This property makes gallium the element with the largest relative difference between melting and boiling points. Gallium has a limited role in biology, and when ingested, it will be subsequently processed by the body and expelled rather than accumulating to toxic levels. The next section of this Technical Memorandum (TM) provides background information on the development of mercury-based ignitrons, which serves as the starting point for the development of the gallium-based variant. Afterwards, the experimental hardware and setup used in proof-of-concept testing of a basic gallium ignitron are presented. Experimental data, consisting of discharge voltage and current waveforms as well as high-speed imaging of the gallium arc discharge in the gallium ignitron test article, are presented to demonstrate the efficacy of the concept. Discussion of the data and suggestions on improvements for future iterations of the design are presented in the final two sections of this TM.

Ali, H. K.↗

Adjustable cutting guide aligns and positions stacks of material

Adjustable guide tool aligns and positions stacks of material for cutting at various angles. The device adapts its shape to stacks of any corner angle, adjusts to any cutting angle, and quickly aligns the stacks for repeated cutting. With this device, an operator need not place his hands under the knife during alignment.

Thiel, A. M.↗

Small, efficient power supply for xenon lamps

Device, which operates from 28 V dc, has four sections, a preregulator, a dc-to-dc converter, a current regulator, and a high voltage starter. The unique characteristics of the individual sections are described.

Goodwin, J. E.↗

Tissue holder for experimental and Demonstration Surgery

Development of device for holding anatomical tissues during operations is discussed. Device consists of plastic dish with hemispherical recess in center to hold excised eyes. Low vacuum applied to underside of recess insures holding of part.

Kuchta, F. J.↗

A space qualified radiation source holder

A radiation source holder was developed to permit controlled exposure of biological material to a gamma-emitting radiation source during flight in a recoverable earth-orbiting satellite. A unique spring drive mechanism, activated by real time commands from the ground station, moved the Sr-85 source from a shielded position to the exposed position and then back to the shielded condition before reentry and recovery. A fail-safe feature utilized the reentry deceleration force to ensure that the source would be in a shielded position during the recovery operations. The device was successfully flown on Biosatellite 2.

Polaski, L. J.↗

Integrated p-channel MOS gyrator

Several circuits can be integrated into one chip for applications which require more than one gyrator. They can also be integrated with other p-channel MOS circuits to eliminate need for external connections. Devices can operate at economical low-power levels, because they use FET amplifiers that do not degrade with decreases in supply.

Hochmair, E. S.↗

A high-speed spectrograph shutter

Device can operate in close-open-close mode. Beam splitter placed behind static-slit assembly allows use of more than one camera. Each frame in particular series may be conveniently varied in exposure time and spacing. This can be done independent of other frames in the series. In ''open'' position, shutter transmits light over wide wavelength range.

Miller, M. H.↗

Hermetic-coaxial package design for microwave transistors

Semiconductor package has been developed for high power semiconductor devices that operate in the GHz-frequency range at several watts. Package includes stud, insulating ring, electrically conductive washer, insulating washer, braze ring, and cap. It is mechanically strong and can be used with variety of circuits.

Jacobson, D. S.↗

Effect of timed secondary-air injection on automotive emissions

A single cylinder of an automotive V-8 engine was fitted with an electronically timed system for the pulsed injection of secondary air. A straight-tube exhaust minimized any mixing other than that produced by secondary-air pulsing. The device was operated over a range of engine loads and speeds. Effects attributable to secondary-air pulsing were found, but emission levels were generally no better than using the engine's own injection system. Under nontypical fast-idle, no-load conditions, emission levels were reduced by roughly a factor of 2.

Coffin, K. P.↗

Reliability improvement of 1 mil aluminum wire bonds for semiconductors, technical performance summary

The reliability of semiconductor devices as influenced by the reliability of wire bonds used in the assembly of the devices is investigated. The specific type of failure dealt with involves fracture of wire bonds as a result of repeated flexure of the wire at the heel of the bond when the devices are operated in an on-off mode. The mechanism of failure is one of induced fracture of the wire. To improve the reliability of a chosen transistor, one-mil diameter wires of aluminum with various alloy additions were studied using an accelerated fatigue testing machine. In addition, the electroprobe was used to study the metallurgy of the wires as to microstructure and kinetics of the growth of insoluble phases. Thermocompression and ultrasonic bonding techniques were also investigated.

Source record↗

Specimen mass measurement

The Skylab specimen mass measurement device was operated throughout the altitude test in close simulation of the 56-day Skylab mission. It performed operational specimen measurements well until it was passed out of the chamber for replacement of the specimen hold-down and was autoclaved prior to return. Fecal measurements were typically made with less than one percent error.

Thornton, W. E.↗

A microprocessor-controlled CCD star tracker

The STELLAR (Star Tracker for Economical Long Life Attitude Reference) utilizes an image sensing Charge-Coupled Device (CCD) operating under microprocessor control. This approach results in a new type of high-accuracy star tracker which can be adapted to a wide variety of different space flight applications through software changes only. The STELLAR determines two-axis star positions by computing the element and the interelement interpolated centroid positions of the star images. As many as 10 stars may be tracked simultaneously, providing significantly increased stability and accuracy. A detailed description of the STELLAR is presented along with measurements of system performance obtained from an operating breadboard model.

Salomon, P. M.↗

Constant-power source for resistive load

Device uses operational amplifiers, dividers, subtractor, pulsed reference amplifier, and associated integrated-circuit components to deliver constantly-adjustable continual power to variable-resistance load for specialized low-power instrumentation applications.

Nagle, E. M.↗

On the determination of series resistance and diode quality factor of solar cells

The series resistance and diode quality factor are used for evaluation of solar cell performance. These parameters are normally deduced from the terminal I-V characteristics under forward bias. The method produces a smaller series resistance and a larger value for diode quality factor than appropriate for the device when operating as a solar cell. It is suggested that the diode quality factor be determined from measured saturated photocurrent, open circuit voltage characteristics and the series resistance be measured with an r-f bridge or calculated from a measurement of the surface sheet resistance.

Anderson, R. L.↗