Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “detector response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Neutron Next-Event Estimators Kinematics (Rev.2)

This paper reviews the kinematics of neutron elastic and inelastic scattering with moving and stationary targets for contributions to Neutron Next-Event Estimators (NEEs). NEEs are often used for simulating the response of detectors in locations that have few random walk particles. Contributions to NEEs from collisions differ from sampling the outgoing particle state in standard random walk collisions as the location of the estimator is fixed, thus fixing the scattering angle between the incoming and outgoing directions. To calculate contributions to NEEs, the outgoing energies and probabilities of scatter toward the estimator must be calculated. This paper presents the most general case that encompasses elastic and inelastic scattering with both moving and stationary targets. The moving target case is required for elastic scattering with thermal motion due to the free gas thermal treatment approximation. The stationary target equations are presented for comparison with equations presented in canonical Monte Carlo texts.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Field Emission Mitigation in CEBAF SRF Cavities Using Deep Learning

The Continuous Electron Beam Accelerator Facility (CEBAF) operates hundreds of superconducting radio frequency (SRF) cavities in its two main linear accelerators. Field emission can occur when the cavities are set to high operating RF gradients and is an ongoing operational challenge. This is especially true in newer, higher gradient SRF cavities. Field emission results in damage to accelerator hardware, generates high levels of neutron and gamma radiation, and has deleterious effects on CEBAF operations. So, field emission reduction is imperative for the reliable, high gradient operation of CEBAF that is required by experimenters. Here we explore the use of deep learning architectures via multilayer perceptron to simultaneously model radiation measurements at multiple detectors in response to arbitrary gradient distributions. These models are trained on collected data and could be used to minimize the radiation production through gradient redistribution. This work builds on previous efforts in developing machine learning (ML) models, and is able to produce similar model performance as our previous ML model without requiring knowledge of the field emission onset for each cavity.

Ahammed, K.↗

SCALE 6.3 Validation: Radiation Shielding

Safe and reliable use of scientific and engineering computer codes requires validation for the types of applications in which they will be used. An example in the nuclear reactor engineering and licensing field is radiation transport employed in shielding analyses. The validity of computer codes for shielding applications is demonstrated in this report for SCALE version 6.3.0. Representative benchmarks corresponding to shielding analyses are selected for the validation study. Typical measurement results analyzed from these benchmarks include neutron fluxes, detector count rates, detector energy response functions, neutron and gamma dose rates, neutron activation rates and activities, neutron leakage fluxes, and skyshine dose rates. Thousands of points of comparison between measurement and calculation are presented in this work. Other than rare outliers typically explained by either a lack of information or large uncertainties in the experiment conditions, material, or dimensions, the Monaco with Automated Variance Reduction using Importance Calculations (MAVRIC) radiation transport computer code with built-in variance reduction methods distributed with the SCALE computer code system agrees well with the measurement results. In selected benchmarks, MAVRIC is also compared to Monte Carlo N- Particle® (MCNP® ) 1 calculations. Both computer codes generally agree well within the estimated uncertainties. With the release of SCALE 6.3.0, Shift was integrated as an alternative transport solver in MAVRIC, denoted MAVRIC-Shift. Although the traditional MAVRIC using Monaco was used primarily in this validation study, many results have also been generated using MAVRIC-Shift. Agreement between MAVRIC-Monaco and MAVRIC-Shift is generally very good. The benchmarks presented in this report were obtained from reliable sources such as the International Criticality Safety Benchmark Evaluation Project Handbook, the Shielding Integral Benchmark Archive & Database, and other shielding validation work found in the literature. Additional datapoints and benchmarks will be added to future versions of this report to expand the shielding validation suite.

61 RADIATION PROTECTION AND DOSIMETRY↗

Response of CR-39 nuclear track detectors to protons with non-normal incidence

This paper presents data from experiments with protons at non-normal incidence to CR-39 nuclear track detectors, analyzing the properties of detection efficiency, proton track diameter, track contrast, and track eccentricity. Understanding the CR-39 response to protons incident at an angle is important for designing charged particle detectors for inertial confinement fusion (ICF) applications. This study considers protons with incident energies less than 3 MeV. In this regime, an incident angle of 10° has no effect on CR-39 detection efficiency, and >85% detection efficiency is preserved up through 25° in the range of 1.0 MeV–2.1 MeV. For ICF applications, incident angles above 30° are deemed impractical for detector design due to significant drops in proton detection at all energies. We observe significant reductions in detection efficiency compared to theoretical predictions, particularly at low energies where proton tracks are etched away. The proton track diameter measured by the scan system is observed to decrease with higher incident angles. The track diameters are analyzed with two fitting models, and it is shown that the diameter–energy relation can be fit with the existing models at angles up to 30° . The optical contrast of the tracks tends to increase with the angle, meaning that the tracks are fainter, and a larger increase is observed for higher energies. Eccentricity, a measure of how elongated proton tracks are, increases with the incident angle and drops after the critical angle. The lowest energy tracks remain nearly circular even at higher angles.

47 OTHER INSTRUMENTATION↗

Response of CR-39 nuclear track detectors to protons with non-normal incidence

This paper presents data from experiments with protons at non-normal incidence to CR-39 nuclear track detectors, analyzing the properties of detection efficiency, proton track diameter, track contrast, and track eccentricity. Understanding the CR-39 response to protons incident at an angle is important for designing charged particle detectors for inertial confinement fusion (ICF) applications. This study considers protons with incident energies less than 3 MeV. In this regime, an incident angle of 10° has no effect on CR-39 detection efficiency, and >85% detection efficiency is preserved up through 25° in the range of 1.0 MeV–2.1 MeV. For ICF applications, incident angles above 30° are deemed impractical for detector design due to significant drops in proton detection at all energies. We observe significant reductions in detection efficiency compared to theoretical predictions, particularly at low energies where proton tracks are etched away. The proton track diameter measured by the scan system is observed to decrease with higher incident angles. The track diameters are analyzed with two fitting models, and it is shown that the diameter–energy relation can be fit with the existing models at angles up to 30°. The optical contrast of the tracks tends to increase with the angle, meaning that the tracks are fainter, and a larger increase is observed for higher energies. Eccentricity, a measure of how elongated proton tracks are, increases with the incident angle and drops after the critical angle. The lowest energy tracks remain nearly circular even at higher angles.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

(Cd,Mg)Te crystals for picosecond-response optical-to-x-ray radiation detectors

We demonstrate a photodetector sensitive to both optical and x-ray picosecond pulses based on our in-house grown cadmium magnesium telluride (Cd,Mg)Te single crystal. Specifically, we developed In-doped Cd0.96Mg0.04Te material and discuss its femtosecond optical photoresponse, as well as the detector performance, such as <100-pA dark current and up to 0.22-mA/W responsivity for 780-nm wavelength optical radiation. The detector exposed to Ti fluorescence (K alpha) x-ray pulses at 4.5 keV, generated by a free-electron laser beam with the central energy of 9.8 keV and <100 fs pulse width, exhibited readout-electronics-limited 200-ps full-width-at-half-maximum photoresponse, demonstrating that it is suitable for coarse timing in free-electron laser x-ray/optical femtosecond pump–probe spectroscopy applications.

Instruments & Instrumentation↗

Scintillation properties of diamond powders and feasibility of using them in thermal neutron detectors

Diamond offers unique properties for radiation detection, including high radiation hardness, very low gamma sensitivity, and fast response. Conventional diamond detectors rely on charge collection, but this approach requires ultra-pure single crystals and suffers from radiation-induced degradation. Here, in this work, we demonstrate an alternative approach using diamonds as scintillators for detection of charged particles and thermal neutrons. Prototypes were fabricated from commercially available diamond powders bonded to glass substrates and coupled with 6 LiF converters and silicon photomultipliers (SiPMs) and conventional PMTs. We characterized their scintillation properties under alpha particle excitation, x-ray photoluminescence, and thermal neutrons. The tryout detectors exhibit strong scintillation light signals, nanosecond-scale response times, and neutron detection efficiencies up to approximately 14 %, evaluated by comparison to conventional 3 He detector with known efficiency. These results demonstrate the feasibility of cost-effective, lightweight and robust diamond scintillation detectors for applications in space and planetary science, nuclear security, safeguards and environmental monitoring requiring efficient, robust, gamma-blind neutron detectors.

47 OTHER INSTRUMENTATION↗

Detector thickness effects on nanosecond-gated imager response

Hybrid CMOS multi-frame imagers with exposure times down to ~2 ns have made significant impacts in high energy density physics and inertial confinement fusion research. The detector thickness is a key parameter in both detector quantum efficiency and temporal response. The Icarus hybrid CMOS imager has been fabricated with Si detector thicknesses of 8, 25, and 100 µm. The temporal response of imaging sensors with exposure time down to 2 ns has been examined and compared to directly measured photodiode current. The 100-μm thick variant displays extended features related to charge carrier collection and is more susceptible to field collapse. Here, we also demonstrate charge collection time effects on spatial response.

47 OTHER INSTRUMENTATION↗

Studies on the response of a water-Cherenkov detector of the Pierre Auger Observatory to atmospheric muons using an RPC hodoscope

Extensive air showers, originating from ultra-high energy cosmic rays, have been successfully measured through the use of arrays of water-Cherenkov detectors (WCDs). Sophisticated analyses exploiting WCD data have made it possible to demonstrate that shower simulations, based on different hadronic-interaction models, cannot reproduce the observed number of muons at the ground. The accurate knowledge of the WCD response to muons is paramount in establishing the exact level of this discrepancy. In this work, we report on a study of the response of a WCD of the Pierre Auger Observatory to atmospheric muons performed with a hodoscope made of resistive plate chambers (RPCs), enabling us to select and reconstruct nearly 600 thousand single muon trajectories with zenith angles ranging from 0$^\circ$ to 55$^\circ$. Comparison of distributions of key observables between the hodoscope data and the predictions of dedicated simulations allows us to demonstrate the accuracy of the latter at a level of 2%. As the WCD calibration is based on its response to atmospheric muons, the hodoscope data are also exploited to show the long-term stability of the procedure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Digital pulse analysis for fast neutron recoil spectroscopy with a 4 He scintillation detector

Helium-4-based fast neutron scintillation detectors are an attractive alternative to pulse-shape discrimination-capable organic scintillators for fast neutron detection and spectroscopy, as the response of the detectors to gamma rays is intrinsically limited to low energy deposition. Consequently, the neutron recoil distribution can be measured with these detectors without the need for pulse shape analysis. In this work, the response of an Arktis S670 4 He scintillation detector to D-D, D-T, and 252 Cf neutrons was measured. The detector has a unique construction and readout mechanism, with multiple output channels observing the same scintillation event, and an analysis method was developed to aggregate the outputs from all channels into a single list. The D-D and D-T neutron responses were used to perform a two-point energy calibration, which yielded a near-zero intercept, suggesting that the 4 He scintillation medium behaves linearly to a higher energy than previously reported, and that a two-point calibration is sufficient for nuclear recoil energies below 9 MeV. As a result, the detector was measured to have 16.7-ns FWHM time resolution when using the developed custom analysis, a reduction of 4.9 ns when compared to the conventional pulse analysis.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Algorithms for coordinate reconstruction in position-sensitive virtual Frisch-grid detectors

Arrays of position-sensitive virtual Frisch-grid (VFG) CdZnTe (CZT) detectors provide a cost-effective solution for integrating large-area arrays for gamma-ray imaging and spectroscopy. These detectors employ high-aspect ratio CZT crystals (bars) with thicknesses up to 50 mm and cross-sections of up to 10 × 10 mm 2 . Despite the long drift distances of charge carriers in such crystals, the detectors have demonstrated excellent performance, achieving energy resolutions better than 1 % full width at half maximum (FWHM) at 662 keV and 3D position resolutions finer than 1 mm. The high spatial resolution is a critical feature of these detectors, as it enables correction of response non-uniformities caused by crystal defects, which remain present even in the highest-quality CZT material. Dislocations and dislocation walls are the primary defects responsible for variations in charge carrier losses as they drift from the interaction points toward the charge-collecting electrodes. The mechanism by which these defects affect carrier transport is generally well understood. Dislocations and sub-grain boundaries act as sinks for carrier-trapping centers, primarily impurities and secondary phases such as tellurium inclusions and precipitates. Here, these regions exhibit significantly higher carrier-trapping rates, leading to variations in the μτ-products. Because the locations of these micron-sized regions are fixed within the detector volume, fluctuations in the total collected charge arise from the random distribution of interaction sites. This results in non-uniform detector responses and degradation of energy resolution. However, by measuring the interaction-site locations with sufficient precision, charge-loss variations can be accurately corrected, allowing recovery of nearly intrinsic energy resolution.

47 OTHER INSTRUMENTATION↗

Measuring Light Yield with Isolated Protons in MicroBooNE

Liquid Argon Time Projection Chambers (LArTPCs) are precision detectors used extensively in neutrino physics. The MicroBooNE experiment at Fermilab is one of the experiments employing this technique and has collected 5 years of data from 2015-2021. The primary signal in LArTPCs is ionisation, but argon also emits large quantities of scintillation light, which can be used for calorimetry, timing and background rejection. Prompt scintillation light in MicroBooNE is recorded with an array of 32 PhotoMultiplier Tubes (PMTs). To enable the full use of scintillation light in the experiment, it is important to characterize the efficiency of light collection in the detector, i.e. the light yield. We present a new method of measuring the light yield using isolated proton interactions, which enables a position-dependent light yield measurement to map the response of the detector across its volume. This method can be used to calibrate the light response in large-scale LArTPC detectors as well as to test assumptions used in simulating scintillation light.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Quantification of LEU Holdup using gamma ray imaging and inverse transport solver

Holdup is the residual amount of special nuclear material (SNM) remaining in a processing facility after the bulk materials have been cleaned out. In commercial uranium processing facilities, quantification of holdup is a major challenge because of the highly variable shapes and sizes of the deposits. Any method that attempts to generalize and calibrate deposit shapes in order to quantify holdup will be prone to high uncertainties. Uncertainties on the order of ±50% are typical in holdup results. In international safeguards applications, a ±50% uncertainty can result in a large amount of material unaccounted for (MUF) thereby increasing the difficulty of detecting material diversion and facility misuse. An imaging-based methodology has been developed with the objective of significantly reducing this uncertainty by using the true deposit shape, instead of relying on oversimplified geometric assumptions. The project is a collaboration between ORNL, Y-12, and the University of Tennessee, Knoxville, TN. Uranium sources of known masses were measured using the Germanium Gamma-ray Imager (GeGI), a high-resolution imaging spectrometer, creating a pixelated map for each spectral bin. Two different gamma imaging methods are employed in this work: coded aperture imaging and Compton imaging. A validated MonteCarlo model of the detector has been developed using the GEANT4 code for determining the intrinsic response of the detector, its enclosure, and the coded aperture mask. An inverse transport solver based on the Markov Chain Monte-Carlo approach known as Differential Evolution Adaptive Metropolis (DREAM) is employed to use the measurement data from the image pixels (coded aperture or Compton) to solve for the mass of 235 U in the deposit. A reliable method based on the DREAM solver has been developed to flag the infinite thickness condition of a uranium deposit. The project team is working towards improving the image reconstruction for Compton imaging so that a better localization of the source can be achieved. Besides treating the coded aperture and Compton imaging methods independently, the project is also evaluating a combined method that uses the Compton scatter data from a coded aperture measurement. GEANT4 simulations are being performed to evaluate the combined approach. The impact on the DREAM optimization as the source thickness progressively approaches infinite thickness is being evaluated. A number of uranium sources available at ORNL have been measured, and the DREAM results have been tested and validated for the coded aperture imaging. A similar effort will be carried out to validate the Compton based method once the development of algorithms for better localization are complete. The imaging based quantification is very amenable to unattended monitoring of holdup accumulation at key measurement points. A proof of concept measurement has been completed to demonstrate this capability The current work used the high energy resolution imager GeGI. However, the approach and methodologies are applicable to other imagers such as the cadmium zin telluride (CZT) based imager manufactured by H3D, Inc.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

X-ray diffraction at the National Ignition Facility

We report details of an experimental platform implemented at the National Ignition Facility to obtain in situ powder diffraction data from solids dynamically compressed to extreme pressures. Thin samples are sandwiched between tamper layers and ramp compressed using a gradual increase in the drive-laser irradiance. Pressure history in the sample is determined using high-precision velocimetry measurements. Up to two independently timed pulses of x rays are produced at or near the time of peak pressure by laser illumination of thin metal foils. The quasi-monochromatic x-ray pulses have a mean wavelength selectable between 0.6 Å and 1.9 Å depending on the foil material. The diffracted signal is recorded on image plates with a typical 2 θ x-ray scattering angle uncertainty of about 0.2° and resolution of about 1°. Analytic expressions are reported for systematic corrections to 2 θ due to finite pinhole size and sample offset. A new variant of a nonlinear background subtraction algorithm is described, which has been used to observe diffraction lines at signal-to-background ratios as low as a few percent. Variations in system response over the detector area are compensated in order to obtain accurate line intensities; this system response calculation includes a new analytic approximation for image-plate sensitivity as a function of photon energy and incident angle. This experimental platform has been used up to 2 TPa (20 Mbar) to determine the crystal structure, measure the density, and evaluate the strain-induced texturing of a variety of compressed samples spanning periods 2–7 on the periodic table.

47 OTHER INSTRUMENTATION↗

Doping liquid argon with xenon in ProtoDUNE Single-Phase: effects on scintillation light

Doping of liquid argon TPCs (LArTPCs) with a small concentration of xenon is a technique for light-shifting and facilitates the detection of the liquid argon scintillation light. In this paper, we present the results of the first doping test ever performed in a kiloton-scale LArTPC. From February to May 2020, we carried out this special run in the single-phase DUNE Far Detector prototype (ProtoDUNE-SP) at CERN, featuring 720 t of total liquid argon mass with 410 t of fiducial mass. A 5.4 ppm nitrogen contamination was present during the xenon doping campaign. The goal of the run was to measure the light and charge response of the detector to the addition of xenon, up to a concentration of 18.8 ppm. The main purpose was to test the possibility for reduction of non-uniformities in light collection, caused by deployment of photon detectors only within the anode planes. Light collection was analysed as a function of the xenon concentration, by using the pre-existing photon detection system (PDS) of ProtoDUNE-SP and an additional smaller set-up installed specifically for this run. In this paper we first summarize our current understanding of the argon-xenon energy transfer process and the impact of the presence of nitrogen in argon with and without xenon dopant. We then describe the key elements of ProtoDUNE-SP and the injection method deployed. Two dedicated photon detectors were able to collect the light produced by xenon and the total light. The ratio of these components was measured to be about 0.65 as 18.8 ppm of xenon were injected. We performed studies of the collection efficiency as a function of the distance between tracks and light detectors, demonstrating enhanced uniformity of response for the anode-mounted PDS. We also show that xenon doping can substantially recover light losses due to contamination of the liquid argon by nitrogen.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improved motional Stark effect signal processing using fast Fourier transform spectral analysis

A Fast Fourier Transform (FFT) based method has been developed, which improves the frequency response of the Motional Stark Effect (MSE) system by about a factor of 10 over the conventional analog lock-in method. The method uses fits to rigorously derived analytic expressions for the FFT spectral components of the MSE signal to accurately obtain the amplitudes and phases of the 2f1 and 2f2 photo-elastic modulator (PEM) frequencies that encode the polarization angle. Since no frequency filtering is used in the FFT method, the frequency response is limited by fundamental measurement properties: the frequency response of the detector, photon statistics, sample rate, and the ability to resolve the spectral components. In contrast, the frequency response of the analog lock-in is limited by a low pass filter with a cutoff of around 500 Hz. In the case of the DIII-D MSE system, the output of the photo-multiplier tube detector was sampled at 500 kHz and FFTs with as few as 100 points were used to obtain the amplitudes of the 2f1 and 2f2 PEM frequency components. This corresponds to a frequency response of 5 kHz, about ten times faster than the analog lock-in amplifier system. Details of the FFT method will be presented and compared to those of the analog lock-in system.

Makowski, M. A.↗

Energy response characterization of current-mode MeV Cherenkov aerogel detectors

Current-mode Cherenkov aerogel detectors have been used to measure time resolved spectra of MeV radiographic x-ray sources and have been considered to replace gas Cherenkov systems. The simulations of the Cherenkov response of aerogel detectors have uncertainties in how to model the complex structure of aerogels. Data from three sites—the Idaho electron beam, the Los Alamos Site electron beam and microtron sources at Los Alamos—have been used to calibrate the relative energy response of 15 aerogels, varying in density from 10 to 430 mg/cm 3 , from incident electrons with energies from 1 to 12 MeV. Detector simulations need to introduce density variation in the aerogels to match the collected data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗