Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “deformation estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Imaging a Free-Geometry Magma Reservoir Using FEM-Based Linear Inverse Modeling of InSAR Data: Application to Rabaul Caldera, Papua New Guinea

We test an innovative inversion scheme using Green’s functions from an array of pressure sources embedded in finite-element method (FEM) models to image, without assuming an a-priori geometry, the composite and complex shape of a volcano deformation source. We invert interferometric synthetic aperture radar (InSAR) data to estimate the pressurization and shape of the magma reservoir of Rabaul caldera, Papua New Guinea. The results image the extended shallow magmatic system responsible for a broad and long-term subsidence of the caldera between 2007 February and 2010 December. Elastic FEM solutions are integrated into the regularized linear inversion of InSAR data of volcano surface displacements in order to obtain a 3-D image of the source of deformation. The Green’s function matrix is constructed from a library of forward line-of-sight displacement solutions for a grid of cubic elementary deformation sources. Each source is sequentially generated by removing the corresponding cubic elements from a common meshed domain and simulating the injection of a fluid mass flux into the cavity, which results in a pressurization and volumetric change of the fluidfilled cavity. The use of a single mesh for the generation of all FEM models avoids the computationally expensive process of non-linear inversion and remeshing a variable geometry domain. Without assuming an a-priori source geometry other than the configuration of the 3-D grid that generates the library of Green’s functions, the geodetic data dictate the geometry of the magma reservoir as a 3-D distribution of pressure (or flux of magma) within the source array. The inversion of InSAR data of Rabaul caldera shows a distribution of interconnected sources forming an amorphous, shallow magmatic system elongated under two opposite sides of the caldera. The marginal areas at the sides of the imaged magmatic system are the possible feeding reservoirs of the ongoing Tavurvur volcano eruption of andesitic products on the east side and of the past Vulcan volcano eruptions of more evolved materials on the west side. The interconnection and spatial distributions of sources correspond to the petrography of the volcanic products described in the literature and to the dynamics of the single and twin eruptions that characterize the caldera. The ability to image the complex geometry of deformation sources in both space and time can improve our ability to monitor active volcanoes, widen our understanding of the dynamics of active volcanic systems and improve the predictions of eruptions.

Inverse theory↗

Imaging the Complex Geometry of a Magma Reservoir Using Fem-Based Linear Inverse Modeling of InSAR Data: Application to Rabaul Caldera, Papua New Guinea

We test an innovative inversion scheme using Green’s functions from an array of pressure sources embedded in finite-element method (FEM) models to image, without assuming an a-priori geometry, the composite and complex shape of a volcano deformation source. We invert interferometric synthetic aperture radar (InSAR) data to estimate the pressurization and shape of the magma reservoir of Rabaul caldera, Papua New Guinea. The results image the extended shallow magmatic system responsible for a broad and long-term subsidence of the caldera between 2007 February and 2010 December. Elastic FEM solutions are integrated into the regularized linear inversion of InSAR data of volcano surface displacements in order to obtain a 3-D image of the source of deformation. The Green’s function matrix is constructed from a library of forward line-of-sight displacement solutions for a grid of cubic elementary deformation sources. Each source is sequentially generated by removing the corresponding cubic elements from a common meshed domain and simulating the injection of a fluid mass flux into the cavity, which results in a pressurization and volumetric change of the fluid-filled cavity. The use of a single mesh for the generation of all FEM models avoids the computationally expensive process of non-linear inversion and remeshing a variable geometry domain. Without assuming an a-priori source geometry other than the configuration of the 3-D grid that generates the library of Green’s functions, the geodetic data dictate the geometry of the magma reservoir as a 3-D distribution of pressure (or flux of magma) within the source array. The inversion of InSAR data of Rabaul caldera shows a distribution of interconnected sources forming an amorphous, shallow magmatic system elongated under two opposite sides of the caldera. The marginal areas at the sides of the imaged magmatic system are the possible feeding reservoirs of the ongoing Tavurvur volcano eruption of andesitic products on the east side and of the past Vulcan volcano eruptions of more evolved materials on the west side. The interconnection and spatial distributions of sources correspond to the petrography of the volcanic products described in the literature and to the dynamics of the single and twin eruptions that characterize the caldera. The ability to image the complex geometry of deformation sources in both space and time can improve our ability to monitor active volcanoes, widen our understanding of the dynamics of active volcanic systems and improve the predictions of eruptions.

Inverse theory↗

Collapse of the electron gas from three to two dimensions in Kohn-Sham density functional theory

Here under pressure, a quasi-2D electron gas can collapse toward the true 2D limit. In this limit, the exact exchange-correlation energy per electron has a known finite limit, but general-purpose semilocal approximate density functionals, like the local density approximation (LDA) and Perdew-Burke-Ernzerhof generalized gradient approximation (PBE GGA), are known to diverge to minus infinity. Here we consider a model density for a non-interacting electron gas confined to a thickness $L$ by infinite-barrier walls, with a fixed 2D density $1/(\pi (r_s^{\text{2D}})^2)$, and $r_s^{\text{2D}}=4$ Bohr. We estimate that LDA, PBE, and the strongly constrained and appropriately normed (SCAN) meta-GGA are accurate for the exchange-correlation energy over a wide quasi-2D range, $1.5< L/r_s^{\text{2D}} < 3.85$, but not for smaller $L$. Of these functionals, only SCAN tends to a finite limit when $L$ tends to 0. Since the non-interacting kinetic energy, treated exactly in Kohn-Sham theory, dominates in this limit within a deformable jellium model, all of the general-purpose functionals can estimate the pressure required to achieve any thickness (with SCAN and LDA better than PBE). This pressure vanishes around $L/r_s^{\text{2D}} = 3.85$, where the 3D electron density is roughly that of the valence electrons in metallic potassium, and reaches about 20 GPa at $L/r_s^{\text{2D}} = 1.5$ and 400 GPa at $L/r_s^{\text{2D}} = 0.6$.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SU-E-J-01: 3D Fluoroscopic Image Estimation From Patient-Specific 4DCBCT-Based Motion Models

Purpose: 3D motion modeling derived from 4DCT images, taken days or weeks before treatment, cannot reliably represent patient anatomy on the day of treatment. We develop a method to generate motion models based on 4DCBCT acquired at the time of treatment, and apply the model to estimate 3D time-varying images (referred to as 3D fluoroscopic images). Methods: Motion models are derived through deformable registration between each 4DCBCT phase, and principal component analysis (PCA) on the resulting displacement vector fields. 3D fluoroscopic images are estimated based on cone-beam projections simulating kV treatment imaging. PCA coefficients are optimized iteratively through comparison of these cone-beam projections and projections estimated based on the motion model. Digital phantoms reproducing ten patient motion trajectories, and a physical phantom with regular and irregular motion derived from measured patient trajectories, are used to evaluate the method in terms of tumor localization, and the global voxel intensity difference compared to ground truth. Results: Experiments included: 1) assuming no anatomic or positioning changes between 4DCT and treatment time; and 2) simulating positioning and tumor baseline shifts at the time of treatment compared to 4DCT acquisition. 4DCBCT were reconstructed from the anatomy as seen at treatment time. In case 1) the tumor localization error and the intensity differences in ten patient were smaller using 4DCT-based motion model, possible due to superior image quality. In case 2) the tumor localization error and intensity differences were 2.85 and 0.15 respectively, using 4DCT-based motion models, and 1.17 and 0.10 using 4DCBCT-based models. 4DCBCT performed better due to its ability to reproduce daily anatomical changes. Conclusion: The study showed an advantage of 4DCBCT-based motion models in the context of 3D fluoroscopic images estimation. Positioning and tumor baseline shift uncertainties were mitigated by the 4DCBCT-based motion models, while they caused errors when using 4DCT-based motion models. Partially funded by Varian research grant.

60 APPLIED LIFE SCIENCES↗

Hot Deformation and Processing Maps of B{sub 4}C/6061Al Nanocomposites Fabricated by Spark Plasma Sintering

We developed 3 vol.% B{sub 4}C/6061Al nanocomposites by spark plasma sintering. We then characterized their flow and hot deformation behaviors using isothermal compression tests at deformation temperatures of 673-823 K and strain rates of 0.001-1 s{sup −1}. Results indicated that their steady flow characteristic can be described by the Zener–Hollomon parameter (Z) as a hyperbolic-sine function of flow stress. Based on pinning effect from B{sub 4}C nanoparticles, the estimated activation energy was calculated to be 274.80 kJ/mol. At the unstable deformation condition (723 K/1 s{sup −1}) with high Z, flow localization appeared; the main softening mechanisms involved are dynamic recovery and dynamic recrystallization (DRX). At the stable deformation condition (823 K/0.001 s{sup −1}) with low Z, adequate DRX occurred. Based on the processing map and microstructure evolution, the optimum hot working conditions for B{sub 4}C/6061Al nanocomposites were determined to be a deformation temperature of 773-823 K and a strain rate of 0.001-0.003 s{sup −1}. These working conditions were verified by a hot extrusion test.

36 MATERIALS SCIENCE↗

Near Real-Time Assessment of Anatomic and Dosimetric Variations for Head and Neck Radiation Therapy via Graphics Processing Unit–based Dose Deformation Framework

Purpose: The purpose of this study was to systematically monitor anatomic variations and their dosimetric consequences during intensity modulated radiation therapy (IMRT) for head and neck (H&N) cancer by using a graphics processing unit (GPU)-based deformable image registration (DIR) framework. Methods and Materials: Eleven IMRT H&N patients undergoing IMRT with daily megavoltage computed tomography (CT) and weekly kilovoltage CT (kVCT) scans were included in this analysis. Pretreatment kVCTs were automatically registered with their corresponding planning CTs through a GPU-based DIR framework. The deformation of each contoured structure in the H&N region was computed to account for nonrigid change in the patient setup. The Jacobian determinant of the planning target volumes and the surrounding critical structures were used to quantify anatomical volume changes. The actual delivered dose was calculated accounting for the organ deformation. The dose distribution uncertainties due to registration errors were estimated using a landmark-based gamma evaluation. Results: Dramatic interfractional anatomic changes were observed. During the treatment course of 6 to 7 weeks, the parotid gland volumes changed up to 34.7%, and the center-of-mass displacement of the 2 parotid glands varied in the range of 0.9 to 8.8 mm. For the primary treatment volume, the cumulative minimum and mean and equivalent uniform doses assessed by the weekly kVCTs were lower than the planned doses by up to 14.9% (P=.14), 2% (P=.39), and 7.3% (P=.05), respectively. The cumulative mean doses were significantly higher than the planned dose for the left parotid (P=.03) and right parotid glands (P=.006). The computation including DIR and dose accumulation was ultrafast (∼45 seconds) with registration accuracy at the subvoxel level. Conclusions: A systematic analysis of anatomic variations in the H&N region and their dosimetric consequences is critical in improving treatment efficacy. Nearly real-time assessment of anatomic and dosimetric variations is feasible using the GPU-based DIR framework. Clinical implementation of this technology may enable timely plan adaptation and improved outcome.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Process–structure–property relationships in bimodal machined microstructures using robust structure descriptors

Machining is a severe plastic deformation process that subjects materials to high rates of deformation and elevated temperatures. Dynamic recrystallization during severe plastic deformation drives grain refinement into the sub-micron range but the ductility and thermal stability of these structures is poor. In contrast, bimodal microstructures consisting of both fine and coarse grains have been shown to exhibit attractive strength and ductility properties at these temperatures. In this paper, we study the process–structure–property relationships for pure copper subject to a machining process where the cutting speeds are varied. Further, we investigate the role of thermal effects by varying the post-deformation cooling rates. Microstructures generated under these deformation conditions are quantified using angularly resolved chord length statistics. The derived metrics are found to be robust descriptors of the studied microstructures as they automatically capture complex features such as unimodal and bimodal distributions of grain structure, grain constituent length scales, and morphological anisotropy induced by shear deformation. The uniaxial equivalent yield strength of the generated structures are estimated using spherical nanoindentation and inverse modeling techniques. Lastly, we present a methodology for identifying the constrained property-process inverse mapping for machining using a Bayesian framework and the established forward process–structure–property mapping.

36 MATERIALS SCIENCE↗

CT image construction of a totally deflated lung using deformable model extrapolation

Purpose: A novel technique is proposed to construct CT image of a totally deflated lung from a free-breathing 4D-CT image sequence acquired preoperatively. Such a constructed CT image is very useful in performing tumor ablative procedures such as lung brachytherapy. Tumor ablative procedures are frequently performed while the lung is totally deflated. Deflating the lung during such procedures renders preoperative images ineffective for targeting the tumor. Furthermore, the problem cannot be solved using intraoperative ultrasound (U.S.) images because U.S. images are very sensitive to small residual amount of air remaining in the deflated lung. One possible solution to address these issues is to register high quality preoperative CT images of the deflated lung with their corresponding low quality intraoperative U.S. images. However, given that such preoperative images correspond to an inflated lung, such CT images need to be processed to construct CT images pertaining to the lung's deflated state. Methods: To obtain the CT images of deflated lung, we present a novel image construction technique using extrapolated deformable registration to predict the deformation the lung undergoes during full deflation. The proposed construction technique involves estimating the lung's air volume in each preoperative image automatically in order to track the respiration phase of each 4D-CT image throughout a respiratory cycle; i.e., the technique does not need any external marker to form a respiratory signal in the process of curve fitting and extrapolation. The extrapolated deformation field is then applied on a preoperative reference image in order to construct the totally deflated lung's CT image. The technique was evaluated experimentally using ex vivo porcine lung. Results: The ex vivo lung experiments led to very encouraging results. In comparison with the CT image of the deflated lung we acquired for the purpose of validation, the constructed CT image was very similar. The intensity mean absolute difference between these two images was calculated to be at 1%. Tumor center as well as a number of anatomical fiducial markers were traced in different corresponding slices of the two images. The average misalignment obtained for the constructed CT image was (0.64, 0.39, 0.11) mm, which indicates a very desirable accuracy for lung brachytherapy applications. Conclusions: The image construction accuracy obtained in this research is suitable for intraoperative tasks; e.g., tumor localization and fusing with real time navigation data in lung brachytherapy. These applications involve image registration with intraoperative U.S. images in order to enhance their poor quality. The proposed technique is also useful for preoperative tasks such as planning of lung brachytherapy treatment.

60 APPLIED LIFE SCIENCES↗

Predicting human blood viscosity in silico

Cellular suspensions such as blood are a part of living organisms and their rheological and flow characteristics determine and affect majority of vital functions. The rheological and flow properties of cell suspensions are determined by collective dynamics of cells, their structure or arrangement, cell properties and interactions. We study these relations for blood in silico using a mesoscopic particle-based method and two different models (multi-scale/low-dimensional) of red blood cells. The models yield accurate quantitative predictions of the dependence of blood viscosity on shear rate and hematocrit. We explicitly model cell aggregation interactions and demonstrate the formation of reversible rouleaux structures resulting in a tremendous increase of blood viscosity at low shear rates and yield stress, in agreement with experiments. The non-Newtonian behavior of such cell suspensions (e.g., shear thinning, yield stress) is analyzed and related to the suspension’s microstructure, deformation and dynamics of single cells. We provide the flrst quantitative estimates of normal stress differences and magnitude of aggregation forces in blood. Finally, the flexibility of the cell models allows them to be employed for quantitative analysis of a much wider class of complex fluids including cell, capsule, and vesicle suspensions.

59 BASIC BIOLOGICAL SCIENCES↗

Low-energy collective modes of deformed superfluid nuclei within the finite-amplitude method

The major challenge for nuclear theory is to describe and predict global properties and collective modes of atomic nuclei. Of particular interest is the response of the nucleus to a time-dependent external field that impacts the low-energy multipole and β -decay strength, as well as individual nuclear excitations. We propose a method to compute low-lying collective modes in deformed nuclei within the finite-amplitude method (FAM) based on the quasiparticle random-phase approximation (QRPA). By using the analytic property of the response function, we find the QRPA amplitudes by computing the residua of the FAM amplitudes by means of a contour integration around the QRPA poles in a complex frequency plane. We use superfluid nuclear density functional theory with Skyrme energy density functionals, the FAM-QRPA approach, and the conventional matrix formulation of the QRPA. We demonstrate that the complex-energy FAM-QRPA method reproduces low-lying collective states obtained within the conventional matrix formulation of the QRPA theory. Illustrative calculations are performed for the isoscalar monopole strength in deformed 24 Mg and for low-lying $K = 0$ quadrupole vibrational modes of deformed Yb and Er isotopes. The proposed FAM-QRPA approach, in addition to providing a quick estimate of various strength functions, allows one to efficiently calculate the individual QRPA amplitudes of the low-lying collective modes in spherical and deformed nuclei throughout the entire nuclear landscape, in particular shape-vibrational and pairing-vibrational modes and β -decay rates. It can also be employed in microscopic approaches to large-amplitude nuclear collective motion based on the adiabatic self-consistent collective coordinate method.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

WE-G-BRD-06: Volumetric Cine MRI (VC-MRI) Estimated Based On Prior Knowledge for On-Board Target Localization

Purpose: To develop a technique to generate on-board VC-MRI using patient prior 4D-MRI, motion modeling and on-board 2D-cine MRI for real-time 3D target verification of liver and lung radiotherapy. Methods: The end-expiration phase images of a 4D-MRI acquired during patient simulation are used as patient prior images. Principal component analysis (PCA) is used to extract 3 major respiratory deformation patterns from the Deformation Field Maps (DFMs) generated between end-expiration phase and all other phases. On-board 2D-cine MRI images are acquired in the axial view. The on-board VC-MRI at any instant is considered as a deformation of the prior MRI at the end-expiration phase. The DFM is represented as a linear combination of the 3 major deformation patterns. The coefficients of the deformation patterns are solved by matching the corresponding 2D slice of the estimated VC-MRI with the acquired single 2D-cine MRI. The method was evaluated using both XCAT (a computerized patient model) simulation of lung cancer patients and MRI data from a real liver cancer patient. The 3D-MRI at every phase except end-expiration phase was used to simulate the ground-truth on-board VC-MRI at different instances, and the center-tumor slice was selected to simulate the on-board 2D-cine images. Results: Image subtraction of ground truth with estimated on-board VC-MRI shows fewer differences than image subtraction of ground truth with prior image. Excellent agreement between profiles was achieved. The normalized cross correlation coefficients between the estimated and ground-truth in the axial, coronal and sagittal views for each time step were >= 0.982, 0.905, 0.961 for XCAT data and >= 0.998, 0.911, 0.9541 for patient data. For XCAT data, the maximum-Volume-Percent-Difference between ground-truth and estimated tumor volumes was 1.6% and the maximum-Center-of-Mass-Shift was 0.9 mm. Conclusion: Preliminary studies demonstrated the feasibility to estimate real-time VC-MRI for on-board target localization before or during radiotherapy treatments. National Institutes of Health Grant No. R01-CA184173; Varian Medical System.

60 APPLIED LIFE SCIENCES↗

Plastic deformation in nanoindentation of tantalum: A new mechanism for prismatic loop formation

Here, the mechanisms of deformation under a nanoindentation in tantalum, chosen as a model body-centered cubic (bcc) metal, are identified and quantified. Molecular dynamics (MD) simulations and indentation experiments are conducted for [1 0 0], [1 1 0] and [1 1 1] normals to surface orientations. The simulated plastic deformation proceeds by the formation of nanotwins, which rapidly evolve into shear dislocation loops. It is shown through a dislocation analysis that an elementary twin (three layers) is energetically favorable for a diameter below ~7 nm, at which point a shear loop comprising a perfect dislocation is formed. MD simulations show that shear loops expand into the material by the advancement of their edge components. Simultaneously with this advancement, screw components of the loop cross-slip and generate a cylindrical surface. When opposite segments approach, they eventually cancel by virtue of the attraction between them, forming a quasi-circular prismatic loop composed of edge dislocation segments. This “lasso”-like mechanism by which a shear loop transitions to a prismatic loop is identified for both [0 0 1] and [1 1 1] indentations. The prismatic loops advance into the material along $\langle$1 1 1$\rangle$ directions, transporting material away from the nucleation site. Analytical calculations supplement MD and experimental observations, and provide a framework for the improved understanding of the evolution of plastic deformation under a nanoindenter. Dislocation densities under the indenter are estimated experimentally (~1.2 × 10 15 m -2 ), by MD (~7 × 10 15 m -2 ) and through an analytical calculation (2.6–19 × 10 15 m -2 ). Considering the assumptions and simplifications, this agreement is considered satisfactory. MD simulations also show expected changes in pile-up symmetry after unloading, compatible with crystal plasticity.

36 MATERIALS SCIENCE↗

Atomic and Molecular Adsorption on Ag(111)

The adsorption of atomic (H, C, N, O, S) and molecular (OH, CH x , NH x , CO, NO, CN, N 2 , HNO, NOH, HCN, x = 1–3) species at 1/4 monolayer coverage on an extended Ag(111) surface was studied here using periodic density functional theory. Geometries and energies were calculated self-consistently using the PW91 functional; nonself-consistent energies using the RPBE functional are also provided. We analyze the binding energies, binding geometries, estimated diffusion barriers, harmonic vibrational frequencies, and energetic and geometric deformation parameters of these adsorbates, comparing them to experimental and theoretical results whenever possible. PW91 gives binding energies that match experimental binding energies more closely than RPBE, which consistently predicts weaker binding than PW91. The data were then used to construct and analyze thermochemistry-only potential energy pathways for the hydrocarbon-assisted and hydrogen-assisted selective catalytic reduction (SCR) of nitric oxide (NO). These analyses provide preliminary insights into the possible mechanistic paths of the SCR of NO on Ag(111). Specifically, we show that deep dehydrogenation leading to the formation of atomic intermediates is not favored on Ag(111).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Monitoring natural gas storage using Synthetic Aperture Radar: are the residuals informative?

Estimates of line-of-sight (LOS) displacements from Interferometric Synthetic Aperture Radar (InSAR) observations serve as the basis of the long-term monitoring of an operating natural gas storage site at Honor Rancho in California. Here, an inversion algorithm is used to estimate the portion of the signal that is attributable to deformation within the gas storage reservoir, located at a depth of around 3 km. Removing this contribution produces residuals that are used to characterize the background variation is surface deformation at the gas storage facility and to determine a threshold that can signify unusually large residuals. An application to almost 7 yr of InSAR data, from 2011 until 2018, indicates that there are intervals of heightened residuals as well as brief episodes of anomalously large misfits. An examination of the spatial distributions of the individual residual LOS displacements indicates larger displacements in an alluvial valley just south of the reservoir, with rapid spatial variations in sign, indicating a rather shallow origin. Furthermore, the two anomalous events also involve rapid spatial variations in the LOS displacement residuals directly above the storage facility. The results demonstrate that the technique of extracting residuals after removing the reservoir signal is a useful approach, even in the case of this deep reservoir, and is a promising method for long-term monitoring.

03 NATURAL GAS↗

Effects of Mn content on the deformation behavior of Fe-Mn-Al-C TWIP steels — A computational study

This paper presents a double-slip/double-twin polycrystal plasticity model using finite element solution to investigate the kinetics of deformation twinning of low-to-medium manganese (Mn) twinning-induced plasticity (TWIP) steels. Empirical equations are employed to estimate the stacking fault energy (SFE) of TWIP steels and the critical resolved shear stress (CRSS) for dislocation slip and deformation twinning, respectively. The results suggest that the evolution of twinning in Fe-xMn-1.4Al-0.6C (x=11.5, 13.5, 15.5, 17.5 and 19.5) TWIP steels, and its relation to the Mn content, can explain the effect of Mn on mechanical properties.the stress-strain. By comparing the double-slip/double-twin model to a double-slip model, the predicted results essentially reveal that the interaction behavior between dislocation slip and deformation twinning can lead to an additional work hardening. Also, numerical simulations are carried out to study the influence of boundary conditions on deformation behavior and twin formation. The nucleation and growth of twinning are found to depend on internal properties (e.g., mismatch orientation of grains and stress redistribution) as well as on external constraints (e.g., the applied boundary conditions) of the material.

Wang, Yuan↗

A software-based x-ray scatter correction method for breast tomosynthesis

Purpose: To develop a software-based scatter correction method for digital breast tomosynthesis (DBT) imaging and investigate its impact on the image quality of tomosynthesis reconstructions of both phantoms and patients. Methods: A Monte Carlo (MC) simulation of x-ray scatter, with geometry matching that of the cranio-caudal (CC) view of a DBT clinical prototype, was developed using the Geant4 toolkit and used to generate maps of the scatter-to-primary ratio (SPR) of a number of homogeneous standard-shaped breasts of varying sizes. Dimension-matched SPR maps were then deformed and registered to DBT acquisition projections, allowing for the estimation of the primary x-ray signal acquired by the imaging system. Noise filtering of the estimated projections was then performed to reduce the impact of the quantum noise of the x-ray scatter. Three dimensional (3D) reconstruction was then performed using the maximum likelihood-expectation maximization (MLEM) method. This process was tested on acquisitions of a heterogeneous 50/50 adipose/glandular tomosynthesis phantom with embedded masses, fibers, and microcalcifications and on acquisitions of patients. The image quality of the reconstructions of the scatter-corrected and uncorrected projections was analyzed by studying the signal-difference-to-noise ratio (SDNR), the integral of the signal in each mass lesion (integrated mass signal, IMS), and the modulation transfer function (MTF). Results: The reconstructions of the scatter-corrected projections demonstrated superior image quality. The SDNR of masses embedded in a 5 cm thick tomosynthesis phantom improved 60%-66%, while the SDNR of the smallest mass in an 8 cm thick phantom improved by 59% (p < 0.01). The IMS of the masses in the 5 cm thick phantom also improved by 15%-29%, while the IMS of the masses in the 8 cm thick phantom improved by 26%-62% (p < 0.01). Some embedded microcalcifications in the tomosynthesis phantoms were visible only in the scatter-corrected reconstructions. The visibility of the findings in two patient images was also improved by the application of the scatter correction algorithm. The MTF of the images did not change after application of the scatter correction algorithm, indicating that spatial resolution was not adversely affected. Conclusions: Our software-based scatter correction algorithm exhibits great potential in improving the image quality of DBT acquisitions of both phantoms and patients. The proposed algorithm does not require a time-consuming MC simulation for each specific case to be corrected, making it applicable in the clinical realm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantitative cone-beam CT imaging in radiation therapy using planning CT as a prior: First patient studies

Purpose: Quantitative cone-beam CT (CBCT) imaging is on increasing demand for high-performance image guided radiation therapy (IGRT). However, the current CBCT has poor image qualities mainly due to scatter contamination. Its current clinical application is therefore limited to patient setup based on only bony structures. To improve CBCT imaging for quantitative use, we recently proposed a correction method using planning CT (pCT) as the prior knowledge. Promising phantom results have been obtained on a tabletop CBCT system, using a correction scheme with rigid registration and without iterations. More challenges arise in clinical implementations of our method, especially because patients have large organ deformation in different scans. In this paper, we propose an improved framework to extend our method from bench to bedside by including several new components. Methods: The basic principle of our correction algorithm is to estimate the primary signals of CBCT projections via forward projection on the pCT image, and then to obtain the low-frequency errors in CBCT raw projections by subtracting the estimated primary signals and low-pass filtering. We improve the algorithm by using deformable registration to minimize the geometry difference between the pCT and the CBCT images. Since the registration performance relies on the accuracy of the CBCT image, we design an optional iterative scheme to update the CBCT image used in the registration. Large correction errors result from the mismatched objects in the pCT and the CBCT scans. Another optional step of gas pocket and couch matching is added into the framework to reduce these effects. Results: The proposed method is evaluated on four prostate patients, of which two cases are presented in detail to investigate the method performance for a large variety of patient geometry in clinical practice. The first patient has small anatomical changes from the planning to the treatment room. Our algorithm works well even without the optional iterations and the gas pocket and couch matching. The image correction on the second patient is more challenging due to the effects of gas pockets and attenuating couch. The improved framework with all new components is used to fully evaluate the correction performance. The enhanced image quality has been evaluated using mean CT number and spatial nonuniformity (SNU) error as well as contrast improvement factor. If the pCT image is considered as the ground truth, on the four patients, the overall mean CT number error is reduced from over 300 HU to below 16 HU in the selected regions of interest (ROIs), and the SNU error is suppressed from over 18% to below 2%. The average soft-tissue contrast is improved by an average factor of 2.6. Conclusions: We further improve our pCT-based CBCT correction algorithm for clinical use. Superior correction performance has been demonstrated on four patient studies. By providing quantitative CBCT images, our approach significantly increases the accuracy of advanced CBCT-based clinical applications for IGRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TH-C-18A-02: Machine Learning and STAPLE Based Simultaneous Longitudinal Segmentation of Bone and Marrow Structures From Dual Energy CT

Purpose: To develop a fully-automatic longitudinal bone and marrow segmentation method in the pelvic region from dual energy computed tomography (DECT). Methods: We developed a two-step automatic bone and marrow segmentation method for simultaneous longitudinal evaluation of patients with metastatic bone disease using dual energy CT (DECT). Our approach transforms the DECT images into a multi-material decomposition (MMD) model that represents the voxels as a mixture of multiple materials. A support vector machine (SVM) was trained using a single scan. In the first step of the longitudinal segmentation the trained SVM model detects bone and marrow structures on all available longitudinal scans. Segmentation is further refined through active contour segmentation. In the second step, the segmentations from the individual scans are merged by employing the simultaneous truth and performance level estimation (STAPLE) algorithm. The scans are registered using affine and deformable registration. We found that our approach improves the segmentation in all the scans under reliable registration performance between the same scans. Improving registration was not under the scope of this work. Results: We applied our approach to segment bone and marrow in DECT scans in the pelvic regions for multiple patients. Each patient had three to five follow up scans. All the patients in the analysis had artificial metal prostheses which introduced challenges for the registration. Our algorithm achieved reasonable accurate segmentation despite the presence of metal artifacts and high-density oral contrast in neighboring structures. Our approach obtained an overall segmentation accuracy of 80% using DICE metric. Conclusion: We developed a two-step automatic longitudinal segmentation technique for bone and marrow region structures in the pelvic areas from dual energy CT. Our approach achieves robust segmentation despite the presence of confounding structures with similar intensities as the bone and marrow regions due to uptake of oral contrast and metal artifacts.

60 APPLIED LIFE SCIENCES↗