Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “deformation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Hot deformation induced defects and performance enhancement in FeSb{sub 2} thermoelectric materials

The effect of hot deformation induced defects and texture on thermoelectric properties of FeSb{sub 2} bulk crystals has been investigated. The transport properties of the samples along both parallel and perpendicular direction of pressing were measured from 3 K to 300 K. The results showed that thermal conductivity of the deformed samples was significantly reduced. After twice deformation, the thermal conductivity of the sample along the perpendicular direction of pressing was decreased to 4 W/mK, which was only one third of that before deformation. Transmission electron microscopy observation revealed the presence of high density of lattice defects in the deformed samples. The lattice thermal conductivity was analyzed using the Debye-Callaway approximation, and the results showed that the deformation induced lattice imperfections play an important role in enhancing phonon scattering. In addition, both the electrical resistivity and Seebeck coefficient exhibited a weak anisotropy in the deformed samples. The figure of merit ZT of the bulk FeSb{sub 2} was significantly improved from 0.010 to 0.021 after deformation.

36 MATERIALS SCIENCE↗

Temperature-dependent mechanical deformation of silicon at the nanoscale: Phase transformation versus defect propagation

This study uses high-temperature nanoindentation coupled with in situ electrical measurements to investigate the temperature dependence (25–200 °C) of the phase transformation behavior of diamond cubic (dc) silicon at the nanoscale. Along with in situ indentation and electrical data, ex situ characterizations, such as Raman and cross-sectional transmission electron microscopy, have been used to reveal the indentation-induced deformation mechanisms. We find that phase transformation and defect propagation within the crystal lattice are not mutually exclusive deformation processes at elevated temperature. Both can occur at temperatures up to 150 °C but to different extents, depending on the temperature and loading conditions. For nanoindentation, we observe that phase transformation is dominant below 100 °C but that deformation by twinning along (111) planes dominates at 150 °C and 200 °C. This work, therefore, provides clear insight into the temperature dependent deformation mechanisms in dc-Si at the nanoscale and helps to clarify previous inconsistencies in the literature.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

PLATFORM DEFORMATION PHASE CORRECTION FOR THE AMiBA-13 COPLANAR INTERFEROMETER

We present a new way to solve the platform deformation problem of coplanar interferometers. The platform of a coplanar interferometer can be deformed due to driving forces and gravity. A deformed platform will induce extra components into the geometric delay of each baseline and change the phases of observed visibilities. The reconstructed images will also be diluted due to the errors of the phases. The platform deformations of The Yuan-Tseh Lee Array for Microwave Background Anisotropy (AMiBA) were modeled based on photogrammetry data with about 20 mount pointing positions. We then used the differential optical pointing error between two optical telescopes to fit the model parameters in the entire horizontal coordinate space. With the platform deformation model, we can predict the errors of the geometric phase delays due to platform deformation with a given azimuth and elevation of the targets and calibrators. After correcting the phases of the radio point sources in the AMiBA interferometric data, we recover 50%-70% flux loss due to phase errors. This allows us to restore more than 90% of a source flux. The method outlined in this work is not only applicable to the correction of deformation for other coplanar telescopes but also to single-dish telescopes with deformation problems. This work also forms the basis of the upcoming science results of AMiBA-13.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Deformation pathway and defect generation in crystals: a combined group theory and graph theory description

The generation and motion of crystalline defects during plastic deformation are critical processes that determine the mechanical properties of a crystal. The types of defect generated are not only related to the symmetry of a crystal but also associated with the symmetry-breaking process during deformation. Proposed here is a new mathematical framework to capture the intrinsic coupling between crystal symmetry and deformation-induced symmetry breaking. Using a combination of group theory and graph theory, a general approach is demonstrated for the systematic determination of the types of crystalline defect induced by plastic deformation, through the construction of a crystal deformation group and a deformation pathway graph. The types of defect generated in the deformation of a face-centered cubic crystal are analyzed through the deformation pathway graph and compared with experimental observations.

36 MATERIALS SCIENCE↗

SU-E-J-195: Quantification of Rotations and Deformations in Head and Heck Radiotherapy

Purpose: To quantify the magnitude of patient rotations and deformations over the course of head and neck radiotherapy. Methods: 45 CBCT images acquired weekly were selected retrospectively from 5 head and neck cancer patients. CBCT images were registered to the corresponding planning CT images using translation, rigid-body, and cubic B-spline deformable transformations. Elastix ( elastix.isi.uu.nl ), an open-source public domain registration algorithm, was used for all registrations with mutual information as similarity metric and gradient descent as optimization. Four-level multiresolution approach was employed with 2 cm B-spline grid spacing at the finest resolution. Registration qualities were visually verified. Rotational occurrences were quantified from the rigid-body registrations. The magnitude of deformations in planning target volumes (PTV) and organs were quantified from the deformation vector fields with rigid registrations as baseline. Results: The measured rotations (mean±std) were 1.0±1.0 deg, - 0.3±1.0 deg, and 0.1±0.8 deg in the sagittal, coronal, and axial plains respectively. The estimated magnitudes of deformations (mean±std) were 3.4±2.1 mm for PTVs, 2.9±1.2 mm for parotid glands, 2.8±1.2 mm for mandible, and 2.2±1.1 mm for spinal cord. The overall deformation in the body contour was 4.3±4.3 mm. The organ spatial deviation due to rotation was small and approximately 8.4% of that from deformations. Results varied among patients. Conclusion: Rotations occurred about 1.0 deg (1SD) in the H'N area. Daily geometric deviation of target volumes was considerable and mainly from tissue deformation than rotations. Proper safety margin is necessary for adequate target coverage. Online plan adaptation may mitigate the daily differences between the plan and actual patient poses. Partially supported by a grant from Varian Medical Systems, Palo Alto, CA.

60 APPLIED LIFE SCIENCES↗

WE-G-18A-05: Cone-Beam CT Reconstruction with Deformed Prior Image

Purpose: Prior image can be incorporated into image reconstruction process to improve the quality of on-treatment cone-beam CT (CBCT) from sparseview or low-dose projections. However, the deformation between the prior image and on-treatment CBCT are not considered in current prior image based reconstructions (e.g., prior image constrained compressed sensing (PICCS)). The purpose of this work is to develop a deformed-prior-imagebased- reconstruction strategy (DPIR) to address the mismatch problem between the prior image and target image. Methods: The deformed prior image is obtained by a projection based registration approach. Specifically, the deformation vector fields (DVF) used to deform the prior image is estimated through matching the forward projection of the prior image and the measured on-treatment projection. The deformed prior image is then used as the prior image in the standard PICCS algorithm. Simulation studies on the XCAT phantom was conducted to evaluate the performance of the projection based registration procedure and the proposed DPIR strategy. Results: The deformed prior image matches the geometry of on-treatment CBCT closer as compared to the original prior image. Using the deformed prior image, the quality of the image reconstructed by DPIR from few-view projection data is greatly improved as compared to the standard PICCS algorithm. The relative image reconstruction error is reduced to 11.13% in the proposed DPIR from 17.57% in the original PICCS. Conclusion: The proposed DPIR approach can solve the mismatch problem between the prior image and target image, which overcomes the limitation of the original PICCS algorithm for CBCT reconstruction from sparse-view or low-dose projections.

60 APPLIED LIFE SCIENCES↗

TH-CD-206-09: Learning-Based MRI-CT Prostate Registration Using Spare Patch-Deformation Dictionary

Purpose: To enable MRI-guided prostate radiotherapy, MRI-CT deformable registration is required to map the MRI-defined tumor and key organ contours onto the CT images. Due to the intrinsic differences in grey-level intensity characteristics between MRI and CT images, the integration of MRI into CT-based radiotherapy is very challenging. We are developing a learning-based registration approach to address this technical challenge. Methods: We propose to estimate the deformation between MRI and CT images in a patch-wise fashion by using the sparse representation technique. Specifically, we assume that two image patches should follow the same deformation if their patch-wise appearance patterns are similar. We first extract a set of key points in the new CT image. Then, for each key point, we adaptively construct a coupled dictionary from the training MRI-CT images, where each coupled element includes both appearance and deformation of the same image patch. After calculating the sparse coefficients in representing the patch appearance of each key point based on the constructed dictionary, we can predict the deformation for this point by applying the same sparse coefficients to the respective deformations in the dictionary. Results: This registration technique was validated with 10 prostate-cancer patients’ data and its performance was compared with the commonly used free-form-deformation-based registration. Several landmarks in both images were identified to evaluate the accuracy of our approach. Overall, the averaged target registration error of the intensity-based registration and the proposed method was 3.8±0.4 mm and 1.9±0.3 mm, respectively. Conclusion: We have developed a novel prostate MR-CT registration approach based on patch-deformation dictionary, demonstrated its clinical feasibility, and validated its accuracy. This technique will either reduce or compensate for the effect of patient-specific treatment variation measured during the course of radiotherapy, is therefore well-suited for a number of MRI-guided adaptive radiotherapy, and potentially enhance prostate radiotherapy treatment outcome.

60 APPLIED LIFE SCIENCES↗

Deformation properties of lead isotopes

The deformation properties of a long lead isotopic chain up to the neutron drip line are analyzed on the basis of the energy density functional (EDF) in the FaNDF{sup 0} Fayans form. The question of whether the ground state of neutron-deficient lead isotopes can have a stable deformation is studied in detail. The prediction of this deformation is contained in the results obtained on the basis of the HFB-17 and HFB-27 Skyrme EDF versions and reported on Internet. The present analysis reveals that this is at odds with experimental data on charge radii and magnetic moments of odd lead isotopes. The Fayans EDF version predicts a spherical ground state for all light lead isotopes, but some of them (for example, {sup 180}Pb and {sup 184}Pb) prove to be very soft—that is, close to the point of a phase transition to a deformed state. Also, the results obtained in our present study are compared with the predictions of some other Skyrme EDF versions, including SKM*, SLy4, SLy6, and UNE1. By and large, their predictions are closer to the results arising upon the application of the Fayans functional. For example, the SLy4 functional predicts, in just the same way as the FaNDF{sup 0} functional, a spherical shape for all nuclei of this region. The remaining three Skyrme EDF versions lead to a deformation of some light lead isotopes, but their number is substantially smaller than that in the case of the HFB-17 and HFB-27 functionals. Moreover, the respective deformation energy is substantially lower, which gives grounds to hope for the restoration of a spherical shape upon going beyond the mean-field approximation, which we use here. Also, the deformation properties of neutron-rich lead isotopes are studied up to the neutron drip line. Here, the results obtained with the FaNDF{sup 0} functional are compared with the predictions of the HFB-17, HFB-27, SKM*, and SLy4 Skyrme EDF versions. All of the EDF versions considered here predict the existence of a region where neutron-rich lead isotopes undergo deformations, but the size of this region is substantially different for the different functionals being considered. Once again, it is maximal for the HFB-17 and HFB-27 functionals, is substantially narrower for the FaNDF{sup 0} functional, and is still narrower for the SKM* and SLy4 functionals. The two-neutron drip line proved to be A{sub drip}{sup 2n} = 266 for all of the EDF versions considered here, with the exception of SKM*, for which it is shifted to A{sub drip}{sup 2n}(SKM*) = 272.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Effect of Annealing on the Impact Resistance and Fracture Mechanism of PNC-60 Sinters After Cold Plastic Deformation

Compaction of sintered metal powders by free upsetting at room temperature dangerously reduces their plastic properties, particularly the fracture toughness. The reason for the occurrence of two unfavorable phenomena accompanying this deformation route is sought. The first phenomenon depends on the initial porosity of the preform and the amount of cold work resulting in the destruction of bonds and violation of continuity between sintered powder particles. The second phenomenon is the deformation of the metal matrix, which reduces the plasticity of the sintered product. To correctly assess the effect of changes occurring in the matrix as a result of deformation, it is necessary to use the properly defined sintered matrix hardening parameter discussed in this study. The adverse effects of cold forming can be eliminated by annealing the deformed sinters at a temperature below the sintering point and above the recrystallization temperature. The annealing temperature causes favorable changes in the structure and increases the impact resistance of the deformed sinters depending on the degree of deformation of the sintered matrix and the initial porosity of the preform. Annealing at a properly selected temperature restores the ductility of the metal matrix and improves the integrity of the sintered material impaired by the effect of deformation. Annealing also causes favorable changes in the porosity morphology, removing defects in the form of gaps and resulting in the spheroidization of voids. With an appropriately selected initial porosity and degree of deformation, subsequent annealing of sinters compacted by free cold upsetting provides products with strength properties comparable to sinters with the same density and subjected to single compaction and sintering but with considerably higher fracture toughness.

36 MATERIALS SCIENCE↗

Deformation Mechanism Map of Cu/Nb Nanoscale Metallic Multilayers as a Function of Temperature and Layer Thickness

The mechanical properties and deformation mechanisms of Cu/Nb nanoscale metallic multilayers (NMMs) manufactured by accumulative roll bonding are studied at 25°C and 400°C. Cu/Nb NMMs with individual layer thicknesses between 7 nm and 63 nm were tested by in situ micropillar compression inside a scanning electron microscope. Yield strength, strain-rate sensitivities and activation volumes were obtained from the pillar compression tests. The deformed micropillars were examined under scanning and transmission electron microscopy in order to examine the deformation mechanisms active for different layer thicknesses and temperatures. The paper suggests that room temperature deformation was determined by dislocation glide at larger layer thicknesses and interface-related mechanisms at the thinner layer thicknesses. The high-temperature compression tests, in contrast, revealed superior thermo-mechanical stability and strength retention for the NMMs with larger layer thicknesses with deformation controlled by dislocation glide. A remarkable transition in deformation mechanism occurred as the layer thickness decreased, to a deformation response controlled by diffusion processes along the interfaces, which resulted in temperature-induced softening. Finally, a deformation mechanism map, in terms of layer thickness and temperature, is proposed from the results obtained in this investigation.

36 MATERIALS SCIENCE↗

Enhancing workability in sheet production of high silicon content electrical steel through large shear deformation

Enhanced workability, as characterized by the magnitude and heterogeneity of accommodated plastic strains during sheet processing, is demonstrated in high Si content Fe-Si alloys containing 4 and 6.5 wt% Si using two single-step, simple-shear deformation techniques – peeling and large strain extrusion machining (LSEM). The model Fe-Si material system was selected for its intrinsically poor material workability, and well-known applications potential in next-generation electric machines. In a comparative study of the deformation characteristics of the shear processes with conventional rolling, two distinct manifestations of workability are observed. For rolling, the relatively diffuse and unconfined deformation zone geometry leads to cracking at low strains, with sheet structures characterized by extensive deformation twinning and banding. Workpiece pre-heating is required to improve the workability in rolling. In contrast, peeling and LSEM produce continuous sheet at large plastic strains without cracking, the result of more confined deformation geometries that enhances the workability. Peeling, however, results in heterogeneous, shear-banded microstructures, pointing to a second type of workability issue – flow localization – that limits sheet processing. This shear banding is to a large extent facilitated by unrestricted flow at the sheet surface, unavoidable in peeling. With additional confinement of this free surface deformation and appropriately designed deformation zone geometry, LSEM is shown to suppress shear banding, resulting in continuous sheet with homogeneous microstructure. Thus LSEM is shown to produce the greatest enhancement in process workability for producing sheet. In conclusion, these workability findings are explained and discussed based on differences in process mechanics and deformation zone geometry.

36 MATERIALS SCIENCE↗

Characterization of mechanical properties and deformation behavior of highly irradiated 316L stainless steel from target modules at the Spallation Neutron Source using digital image correlation analysis

Tensile specimens with irradiation doses ranging from approximately 0.7 to 7.6 displacements per atom (dpa) were fabricated from 316L samples removed from Spallation Neutron Source (SNS) target vessels after service. Tensile tests were performed in conjunction with digital image correlation (DIC) characterization, which permitted detailed analysis of the strain distribution and deformation behavior of the specimen gauge sections during testing. The results show, while considerable hardening (500–700 MPa increase in yield strength) occurred in the 316L SNS target material with increasing dose, appreciable ductility (19–23% total elongation) remained in the material after irradiation to 7.6 dpa in the mixed neutron/proton environment of the SNS target region. The DIC data showed the strain distribution and deformation behavior of all irradiated specimens were nonuniform during testing. Strain localization in the form of deformation bands or “hotspots” was observed during testing, and in some specimens, the bands propagated as deformation waves along the gauge section. The “traveling wave” deformation behavior affected the amount of elongation each specimen achieved, and the scatter in the elongation data was attributed to the large variation in deformation behavior observed among different specimens. Bands of localized strain, or deformation bands, oriented at specific angles were observed in two-dimensional plots of the strain distribution in the gauge sections of some specimens. Overall, this paper describes the experimental procedures, results, and deformation behavior of tensile specimens from SNS targets after service and illustrates the value of DIC characterization during tensile testing of irradiated materials.

36 MATERIALS SCIENCE↗

Study on hot deformation behavior and workability of squeeze-cast 20 vol%SiCw/6061Al composites using processing map

Highlights: • Prasad’s and Murty’s criteria were better than Gegel’s criterion in predicting the flow instability for the composites. • Partial melting and DRX at high temperature and high strain rate improved the workability of the composites. • The softening mechanism changed from DRV to DRX with the increase of deformation temperature and strain rate. • The safe deformation region of the composites was at higher temperature of 450-500°C and higher strain rate of 0.1-1s{sup -1}. • The safe deformation region predicted by processing maps was validated by uniaxial upsetting and two-directional forging. - Abstract: The hot deformation behavior and workability of squeeze-cast 20 vol%SiCw/6061Al composites were investigated by isothermal compression test and development of processing map, which was verified by uniaxial upsetting and two-directional forging of big cylindrical billets. Due to dispersed strengthening caused by SiC whiskers, the activation energy of 20 vol%SiCw/6061Al composites was much higher than the self-diffusion activation energy of pure Al. Both the DMM and MDMM were reliable in predicting the safe deformation regions. The instability regions predicted by the Prasad's and Murty's instability criterion were smaller than the actual ones, while the Gegel's instability criterion was not appropriate in predicting the instability regions of 20 vol%SiCw/6061Al composites. The optimum deformation region was at higher temperature of 450–500 °C and higher strain rate of 0.1–1 s{sup − 1}, in which the compressed samples exhibited perfect surface without cracks and microstructure with few of cavities due to the occurrence of partial melting and dynamic recrystallization. With the increase of deformation temperature and strain rate, the deformation mechanism changed from dynamic recovery to dynamic recrystallization. Squeezing casting technique with high filtration pressure may also contribute to the increase of strain rate of DRX, which was helpful for hot forging of Al matrix composites with high productivity.

36 MATERIALS SCIENCE↗

Hot deformation behavior and flow stress modeling of a Ni-based superalloy

The deformation behavior of a novel Ni-based superalloy was investigated using isothermal compression on a Gleeble system at temperatures between 1050 and 1210 °C with strain rates between 0.001 and 0.1 s –1 . Flow-stress curves and electron backscatter diffraction maps were employed to experimentally identify the various flow mechanisms operative during deformation. Deformation at temperatures below 1130 °C presented strong work hardening with limited restoration during dynamic softening leading to partially recrystallized microstructures. Increasing the deformation temperature to and above 1130°C enhanced the driving force for dislocation and grain boundary mobility thereby enabling dynamic recovery (DRV) and dynamic recrystallization (DRX) mechanisms to better operate. Here, the influence of the strain rate was more evident during deformation at these temperatures. Increasing the strain rate from 0.001 s –1 to 0.1 s –1 resulted in a transition in dominant softening mechanism from DRV to DRX. Flow stress modeling using the Zener-Hollomon parameter was performed to obtain the activation energy and the constitutive equation for hot deformation of the alloy. Strong changes in flow behavior affected the accuracy of the flow stress model, and thus, the model was used alternatively to identify deformation parameters associated with various flow regimes. In doing so, the activation energy and the other equation constants were obtained for each deformation mechanism observed experimentally.

36 MATERIALS SCIENCE↗

Automated identification of deformation twin systems in Mg WE43 from SEM DIC

In this study, the application of machine learning and computer vision approaches to microscale deformation data for the automated identification of deformation twinning systems, and their associated twin area, is introduced. Deformation data was obtained during in-situ SEM compression testing of a WE43 Mg alloy using digital image correlation (DIC) modified for use with electron microscopy. A 5.7 mm × 3.4 mm area of interest was analyzed, generating ~100 million data points of deformation. Experimental twin trace directions were determined by applying k-means clustering, morphological thinning, and Hough transforms to the deformation data. The identification of deformation twinning was achieved by consideration of the twin trace direction, its strain value, and its evolution. The deformation map was divided into areas corresponding to individual active twin systems, enabling the analysis of microstructure dependence of deformation behavior and twinning activity. The performance of the proposed twinning identification approach was evaluated by accuracy, precision, and sensitivity metrics. The effect of the tuning parameters used in the algorithm on the performance is also discussed.

36 MATERIALS SCIENCE↗

Importance of deformable image registration and biological dose summation in planning of radiotherapy retreatments

The purpose of this study is to evaluate the effect of nonrigid and fractionation-corrected dose summation on total doses in radiotherapy and to demonstrate the benefits of such dose summation on clinical decision-making for planning of retreatments. Dose summation of organs at risk (OARs) was investigated for 3 clinical cases with need of retreatment to the same site: head and neck, brain, and mediastinum. Three different summation methods over old and new radiotherapy treatment plans are presented and compared: (1) rigid raw sum with rigid registration of the planning images and direct dose summing; (2) deformable raw sum with deformable image registration and direct dose summing; and (3) deformable biological sum with deformable registration and takes into account the dose per fraction in biological manner in certain critical organs. In 2 cases, a user-defined dose downscaling is applied to take into account the time between the treatments and the healing from the radiation-induced effects. Of the 3 summation methods presented, the deformable biological sum was considered to offer the most biologically plausible account of the treatment. There were remarkable differences between near-maximum doses (D0.1cc) and dose-volume histogram (DVH) curves for OARs between different summation methods. The differences between deformable raw sum and rigid raw sum D0.1cc doses are in the range from −8 Gy to 2 Gy. Similarly, the deviation was from −14 Gy to 5 Gy for the deformable biological sum compared with the rigid raw sum. These differences come from incorrect summation of doses in the rigid raw sum case, and from the dose per fraction effect in biological summation. We conclude that computing the 3-dimensional deformable biological summation could be a valuable tool for treating patients with complex retreatments. It has the potential to assist the oncologist in refining plans for maximally curative doses while respecting appropriate tissue tolerances.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Role of B19' martensite deformation in stabilizing two-way shape memory behavior in NiTi

Deformation of a B19' martensitic, polycrystallineNi49.9Ti50.1 (at. %) shape memoryalloy and its influence on the magnitude and stability of the ensuing two-way shape memory effect (TWSME) was investigated by combined ex situ mechanical experimentation and in situneutron diffraction measurements at stress and temperature. The microstructural changes (texture, lattice strains, and phase fractions) during room-temperature deformation and subsequent thermal cycling were captured and compared to the bulk macroscopic response of the alloy. With increasing uniaxial strain, it was observed that B19' martensite deformed by reorientation and detwinning with preferred selection of the (1¯50) M and (010) M variants, (201¯) B19' deformation twinning, and dislocation activity. These mechanisms were indicated by changes in bulk texture from the neutron diffraction measurements. Partial reversibility of the reoriented variants and deformation twins was also captured upon load removal and thermal cycling, which after isothermal deformation to strains between 6% and 22% resulted in a strong TWSME. Consequently, TWSME functional parameters including TWSME strain, strain reduction, and transformation temperatures were characterized and it was found that prior martensite deformation to 14% strain provided the optimum condition for the TWSME, resulting in a stable two-way shape memory strain of 2.2%. Thus, isothermal deformation of martensite was found to be a quick and efficient method for creating a strong and stable TWSME in Ni₄₉.₉Ti₅₀.₁.

Benafan, O.↗

Surface dislocation nucleation controlled deformation of Au nanowires

We investigate deformation in high quality Au nanowires under both tension and bending using in-situ transmission electron microscopy. Defect evolution is investigated during: (1) tensile deformation of 〈110〉 oriented, initially defect-free, single crystal nanowires with cross-sectional widths between 30 and 300 nm, (2) bending deformation of the same wires, and (3) tensile deformation of wires containing coherent twin boundaries along their lengths. We observe the formation of twins and stacking faults in the single crystal wires under tension, and storage of full dislocations after bending of single crystal wires and after tension of twinned wires. The stress state dependence of the deformation morphology and the formation of stacking faults and twins are not features of bulk Au, where deformation is controlled by dislocation interactions. Instead, we attribute the deformation morphologies to the surface nucleation of either leading or trailing partial dislocations, depending on the Schmid factors, which move through and exit the wires producing stacking faults or full dislocation slip. The presence of obstacles such as neutral planes or twin boundaries hinder the egress of the freshly nucleated dislocations and allow trailing and leading partial dislocations to combine and to be stored as full dislocations in the wires. We infer that the twins and stacking faults often observed in nanoscale Au specimens are not a direct size effect but the result of a size and obstacle dependent transition from dislocation interaction controlled to dislocation nucleation controlled deformation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗