Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “data transfers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Real-time sensor measurements to evaluate impacts of load cycling on high-temperature fire-side corrosion in a PC boiler

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of coal-fired utility boilers in this project but can be applied to many other industries and applications as well. This project leveraged the existing electrochemical noise-based monitoring system and the new sensor design is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data is transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, the three mMPMS were installed at a full-scale pulverized coal-fired plant, PacifiCorp’s Hunter 3. The systems were demonstrated over 20,000 hours at the plant during regular operation. Also, the sensor data was fed to the plant’s advanced process control system to evaluate the corrosion control by the operation changes and utilized to understand the impacts of load cycling with different ramping up and down speeds. At the end of the project, the systems were converted to the permanent installation at the power plant to be used with the advanced process control system installed at the plant.

Advanced Sensors, Corrosion, Ash Deposition, Optim↗

High-Temperature Multi-Process Sensor Development and Demonstration at Coalfired Power Plants

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of coal-fired utility boilers in this project but can be applied to many other industries and applications as well. This project leveraged the existing electrochemical noise-based monitoring system and the new sensor design is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data is transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, the three mMPMS were installed at a full-scale pulverized coal-fired plant, PacifiCorp’s Hunter 3. The systems were demonstrated over 20,000 hours at the plant during regular operation. Also, the sensor data was fed to the plant’s advanced process control system to evaluate the corrosion control by the operation changes and utilized to understand the impacts of load cycling with different ramping up and down speeds. At the end of the project, the systems were converted to the permanent installation at the power plant to be used with the advanced process control system installed at the plant.

Advanced Sensors, Corrosion, Ash Deposition, Optim↗

Full-scale Demonstration of Multi-process Sensor at a Cycling PC-fired Boiler

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of coal-fired utility boilers in this project but can be applied to many other industries and applications as well. This project leveraged the existing electrochemical noise-based monitoring system and the new sensor design is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data is transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, the three mMPMS were installed at a full-scale pulverized coal-fired plant, PacifiCorp’s Hunter 3. The systems were demonstrated over 20,000 hours at the plant during regular operation. Also, the sensor data was fed to the plant’s advanced process control system to evaluate the corrosion control by the operation changes and utilized to understand the impacts of load cycling with different ramping up and down speeds. At the end of the project, the systems were converted to the permanent installation at the power plant to be used with the advanced process control system installed at the plant.

Advanced Sensors, Corrosion, Ash Deposition, Optim↗

High-Temperature Multi-Process Sensor Development and Demonstration at a Full-scale PC Combustion System

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of coal-fired utility boilers in this project but can be applied to many other industries and applications as well. This project leveraged the existing electrochemical noise-based monitoring system and the new sensor design is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data is transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, the three mMPMS were installed at a full-scale pulverized coal-fired plant, PacifiCorp’s Hunter 3. The systems were demonstrated over 20,000 hours at the plant during regular operation. Also, the sensor data was fed to the plant’s advanced process control system to evaluate the corrosion control by the operation changes and utilized to understand the impacts of load cycling with different ramping up and down speeds. At the end of the project, the systems were converted to the permanent installation at the power plant to be used with the advanced process control system installed at the plant.

Advanced Sensors, Corrosion, Ash Deposition, Optim↗

Nanosecond Gated CMOS Camera (NSGCC) ICD (Rev. 2.1)

The Ultra-Fast X-ray Imager (UXI) program is an ongoing effort at Sandia National Laboratories to create high speed, multi-frame, time-gated Read Out Integrated Circuits (ROICs), and a corresponding suite of photodetectors to image a wide variety of High Energy Density (HED) physics experiments on both Sandia’s Z-Machine and LLNL’s National Ignition Facility (NIF). Several cameras have been designed over the length of the program; one of the most recent is the Icarus, which is an improvement on past imagers (Furi and Hippogriff). A second sensor that can be connected is the Daedalus sensor. The Icarus is a 1024 × 512-pixel array with either 25 μm or 8 µm spatial resolution containing four frames of storage per pixel and has improved timing generation and distribution components while achieved 2 ns time gating. The Daedalus sensor is also a 1024 x 512-pixel array with 25 µm special resolution containing three frames of storage per pixel and has an increased set of features for a wider variety of applications from interlacing of rows in each frame to configurability of all shutters. See Section 14 for details regarding the Icarus implementation of the firmware and Section 15 for details regarding the Daedalus implementation. Due to the unique test environments UXI sensors are targeted for, full custom hardware was required to physically mount an Icarus or Daedalus sensor, manage its various functions, and read out pixel data for transfer to a host computer. Beyond experimental functionality, the hardware also needed to accommodate sensor characterization requirements. Lawrence Livermore National Laboratory’s ‘Version 4.0 Board’ was the result of these efforts. It mounts all the components required to fully utilize the Icarus and Daedalus sensors including analog to digital converters to convert pixel data and various system voltages to digital form for readout and analysis, DAC channels for remote configuration of critical bias voltages, static random-access memories to buffer pixel data, RS422 and Gigabit Ethernet communications for remote access, and an FPGA to tie these components together. This document describes the FPGA electrical interfaces in detail to allow the reader a greater understanding of the device, and to facilitate implementation of custom software to control and manage it. The Version 4.0 Board is a continuation of the Nano-second Gated CMOS hardware design that retains much of the functionality of the Version 1.0 Board while adding features including a DAC instead of digital potentiometers, as well as sensors for pressure and radiation. The Version 4.0 board is intended for applications requiring tight form-factor enclosures. It is composed of two stacking boards; one holds the FPGA and regulators to power the various components of the board while the other contains the mating connector to the sensor, image-readoff ADCs, the DAC, and other components.

42 ENGINEERING↗

KBase Silver Case Study: Determining Media Formulation Requirements for Isolation of Microbiome Constituents

KBase has powerful tools for extracting microbial genomes from metagenomes and performing phylogenomic analysis and metabolic modeling. These tools can be used to predict key media ingredients for isolating uncultured members of microbiomes. Essential to this process are high-quality genomes extracted from metagenomic assemblies, and Kbase has a tool for assessing the quality of genomes too. Below we identify growth factors for a myxobacteria ("slime bacteria") yet to be isolated from the rhizosphere of Miscanthus xgiganteus (hybrid of "Silvergrass"), cultivated at the Kellogg Biological Station in Michigan. Data was transferred with Globus from JGI-IMG. This narrative and the "KBase Gold Case Study: Can you find Delftia?" make up the Silver and Gold Narrative Set for teaching metagenomics concepts to students in the BIT 477/577 course at North Carolina State University. This tutorial will guide the user through the process of extracting and annotating high-quality genomes from a metagenomic data, performing phylogenomic analysis, building a metabolic model, and using these to predict nutrient requirments for growth and isolation of corresponding microbes.

59 BASIC BIOLOGICAL SCIENCES↗

Creation Synthetic Data to Train a Digital Twin to Predict Reactor Operations

Understanding techniques to strengthen the nuclear safeguards regime is crucial in preventing nuclear proliferation due to recent advancements in the nuclear energy industry such as Generation IV reactors and microreactors. Prior to the construction of a nuclear power plant, it is necessary to understand the proliferation potential of the plant's reactor. Digital twins serve as a unique solution to recognizing reactor behavior indicative of nuclear proliferation. A digital twin is defined as a virtual model that works in unison to represent a physical asset, with a transference of data between the virtual and physical assets [1]. This work serves as validation for training a digital twin on synthetic data fabricated via means of Serpent reactor physics and point kinetics equations simulations. In this case this work is based on parameters of Idaho State University's AGN-201 reactor. The synthetic data can then be utilized to train machine learning models in the future to further investigate the utility of these methods. The accuracy of the predicted data is measured against real operational data to verify the reliability of the synthetic data creation methods and decide whether these methods should be used in the future to inform inspectors of a reactor's proliferation potential.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Direct reactions with the AT-TPC

Direct reactions are crucial tools for accessing properties of the atomic nucleus. Fundamental and exotic phenomena such as collective modes, pairing, weakbinding effects and evolution of single-particles energies can be investigated in peripheral collisions between a heavy nucleus and a light target. The necessity of using inverse kinematics to reveal how these structural properties change with isospin imbalance renders direct reactions a challenging technique when using the missing mass method. In this scenario, Active Target Time Projection Chambers (AT-TPC) have demonstrated an outstanding performance in enabling these types of reactions even under conditions of very low beam intensities. The AT-TPC of the Facility for Rare Isotope Beams (FRIB) is a next generation multipurpose Active Target. When operated inside a solenoidal magnet, direct reactions benefit from the measurement of the magnetic rigidity that enables particle identification and the determination of the excitation energy with high resolution without the need of auxiliary detectors. Additionally, the AT-TPC can be coupled to a magnetic spectrometer improving even further its spectroscopic investigation capability. In this contribution, we discuss inelastic scattering and transfer reaction data obtained via the AT-TPC and compare them to theory. In particular, we present the results for the 14 C(p,p′) and 12 Be (p,d) 11 Be reactions. For 14 C, we compare the experimental excitation energy of the first 1 – excited state with coupled-cluster calculationsbased on nuclear interactions from chiral effective field theory and with available shell-model predictions. For 12 Be, we determine the theoretical spectroscopic factors of the 12 Be (p,d) 11 Be transfer reaction in the shell modeland compare them to the experimental excitation spectrum from a qualitative standpoint.

active target↗

Remote Instrumentation and Data Acquisition

This poster outlines the development and implementation of a remote data acquisition system for waveform analysis using a Rohde & Schwarz oscilloscope. The project involved capturing waveform data, and transferring it to a local machine for visualization and analysis. The core logic was developed in C++ with a focus on object oriented programming and the use of polymorphism so the main application can interact with any instrument without knowing its exact type, simplifying the overall logic and making it easier to add or swap out components without changing the rest of the codebase.. The system issues Standard Commands for Programmable Instruments (SCPI) via a socket connection and parses the oscilloscope s ASCII waveform data. The C++ application was containerized using Docker for ease of portability, and reproducibility. Emphasis was placed on secure networking practices, error handling, and effective data capture. The report describes the technical steps taken, challenges encountered, and future work, providing insight into the practical integration of hardware interfacing with remote computational environments.

Parikh, Jaymil [Illinois U., Urbana]↗

Remote Instrumentation and Data Acquisition: An Internship Research Report

This report outlines the development and implementation of a remote data acquisition system for waveform analysis using a Rohde & Schwarz oscilloscope. The project involved capturing waveform data, and transferring it to a local machine for visualization and analysis. The core logic was developed in C++ with a focus on object oriented programming and the use of polymorphism so the main application can interact with any instrument without knowing its exact type, simplifying the overall logic and making it easier to add or swap out components without changing the rest of the codebase.. The system issues Standard Commands for Programmable Instruments (SCPI) via a socket connection and parses the oscilloscope’s ASCII waveform data. The C++ application was containerized using Docker for ease of portability, and reproducibility. Emphasis was placed on secure networking practices, error handling, and effective data capture. The report describes the technical steps taken, challenges encountered, and lessons learned, providing insight into the practical integration of hardware interfacing with remote computational environments.

Parikh, Jaymil [Fermilab]↗

TEMPI: An Interposed MPI Library with Canonical Representation of MPI Datatypes [Poster]

TEMPI provides a transparent non-contiguous data-handling layer compatible with various MPIs. MPI Datatypes are a powerful abstraction for allowing an MPI implementation to operate on non-contiguous data. CUDA-aware MPI implementations must also manage transfer of such data between the host system and GPU. The non-unique and recursive nature of MPI datatypes mean that providing fast GPU handling is a challenge. The same noncontiguous pattern may be described in a variety of ways, all of which should be treated equivalently by an implementation. This work introduces a novel technique to do this for strided datatypes. Methods for transferring non-contiguous data between the CPU and GPU depends on the properties of the data layout. This work shows that a simple performance model can accurately select the fastest method. Unfortunately, the combination of MPI software and system hardware available may not provide sufficient performance. The contributions of this work are deployed on OLCF Summit through an interposer library which does not require privileged access to the system to use

97 MATHEMATICS AND COMPUTING↗

User-Oriented Improvements in the MOOSE framework in support of Multiphysics Simulation

The MOOSE Framework is a foundational capability used by NEAMS to create over 15 different simulation tools for advanced nuclear reactors. Due to this ubiquity, improvements to the framework in support of modeling and simulation goals are critical to the program. These improvements can take many forms including optimization, improved user experience, streamlined APIs, parallelism, and new capability. The work transcribed in the report was in direct support of the simulation tools and is already deployed or will be deployed in the coming months. The capabilities implemented were, in the same order as this report, chainable execution objects or executors, support for transfers between applications at the same level in a coupling scheme, support for boundary/subdomain restricted transfers, support for transfers between applications with different coordinate or unit systems, support for MOOSE applications in the NEAMS workbench, deployment of MOOSE application of the INL HPC OnDemand platform, addition of a triangular meshing library in libMesh and increased support of face variables.

97 MATHEMATICS AND COMPUTING↗

ThunderSecure: deploying real-time intrusion detection for 100G research networks by leveraging stream-based features and one-class classification network

Nowadays, data generated by large-scale scientific experiments are on the scale of petabytes per month. These data are transferred through dedicated high-bandwidth networks (40/100G) across distributed sites for processing, storage, and analysis. Like general purpose networks, research networks experience intrusions. However, monitoring anomalies in such high-speed network traffics is challenging given current cyber-infrastructure. Moreover, traditional network intrusion detection systems (NIDS) are signature based. However, anomaly patterns are difficult to define and that rulesets are often not updated frequently enough to reflect the changes of attack behaviors. We present ThunderSecure, a high-throughput, unsupervised learning-based intrusions detection system for 100G research networks. ThunderSecure implements an efficient packet processing and detection pipeline using multi-cores and GPUs. It extracts statistical and temporal features from real-time network data streams and feeds them to a one-class anomaly detection network. A baseline of normal distribution will be created based on the training observation. Testing traffic deviated from the learned profile will be marked as anomalies. We trained ThunderSecure on hundreds of billions of science data packets mirrored from two 100G network connections at Fermi National Accelerator Laboratory. The detection performance was evaluated on traffic captured from the same research network days and weeks after the training with different types of attack flows injected. Results show that ThunderSecure can recognize science data traffic captured long after the training and made nearly certain detection on the segment of the streams where anomalous flows were injected.

100G research network↗

Distributed ADMM Using Private Blockchain for Power Flow Optimization in Distribution Network With Coupled and Mixed-Integer Constraints

The optimization problem for scheduling distributed energy resources (DERs) and battery energy storage systems (BESS) integrated with the power grid is important to minimize energy consumption from conventional sources in response to demand. Conventionally this optimization problem is solved in a centralized manner, limiting the size of the problem that can be solved and creating a high communication overhead because all the data is transferred to the central controller. These limitations are addressed by the proposed distributed consensus-based alternating direction method of multiplier (DC-ADMM) optimization algorithm, which decomposes the optimization problem into subproblems with private cost function and constraints. The distribution feeder is partitioned into low coupling subnetworks/regions, which solves the private subproblem locally and exchanges information with the neighboring regions to reach consensus. The relaxation strategy is employed for mixed-integer and coupled constraints introduced in the optimal power flow (OPF) problem by stationary and transportable BESS because DC-ADMM convergence is only guaranteed for strict convex problems. The information exchange and synchronization between subnetworks/regions are vital for distributed optimization. In this work, both of these aspects are addressed by the blockchain. The smart contract deployed on the blockchain network acts as a mediator for secure data exchange and synchronization in distributed computation. The blockchain-based distributed optimization problem’s effectiveness is tested for a 0.5-MW laboratory microgrid for one hour ahead and day-ahead for the IEEE 123-bus and EPRI J1 test feeders, and results are compared with a centralized solution.

25 ENERGY STORAGE↗

Transfer-Learnt Energy Models for Predicting Electricity Consumption in Buildings with Limited and Sparse Field Data

Modeling energy consumption is critical for energy-efficient utilization of the electric appliances in a building, smart grid programs (like demand-response), and many other smart home applications. State-of-the-art energy modeling techniques either rely on theoretical models, or extensive instrumentation of the building envelope to gather ``big" data to train a deep neural network. While theoretical models are often limited by their estimation accuracy, it is not always feasible to gather a significant amount of field data. In this paper, we explore transfer learning-based strategies to train much more accurate model for energy estimation when using a sparse field data. We transferred knowledge, in the form of data and parameters, from the simulation framework to the field data. We evaluated the efficacy of our approach on field data collected from six commercial buildings and our results indicate that transfer learning-based models trained over one month data can perform comparative (and in some cases better) than the state-of-the-art machine learning and deep learning solutions.

Jain, Milan↗

Real-time Intrusion Detection for High-bandwidth Research Networks using Unsupervised Deep Learning

Nowadays, data generated by large-scale scientific experiments are on the scale of petabytes per month. These data are transferred through dedicated high-bandwidth networks across distributed collaboration sites for processing, storage, and analysis. Like general purpose networks, research networks experience attacks. However, monitoring traffic in such high-bandwidth network environments is challenging with conventional deep packet inspection (DPI)- based network intrusion detection systems (NIDS). Recently, machine learning (ML) algorithms have shown potential in detecting anomalous patterns with better generalizability and faster speed. Compared to the general purpose networks, traffic movement in research network is less volatile and more likely to benefit from the ML-based anomaly analysis. We present ThunderSecure, an efficient AI-powered system for detecting anomalies in 100G research networks. ThunderSecure implements a high-throughput packet processing infrastructure using multi-cores and GPUs. It takes time-series statistics from a variety of network measurements and uses 2D Convolutional Neural Network (CNN) to explore both spatial and temporal dependencies in network data stream. Patterns of science data traffic are learned with a one-class neural network, which blends an Adversarial Autoencoder (AAE) with Gaussian mixture density estimation. Testing traffic flows exhibiting significant deviations from the learned baseline of normality are marked as anomalies. We trained ThunderSecure on hundreds of billions of science data packets recorded from a 100G research network at Fermi National Accelerator Laboratory. The detection performance was evaluated on traffic captured from the same research network days and weeks after the training with different types of attack flows injected. To the best of our knowledge, this is the first ML work in the area of network anomaly detection that has been validated on such extreme scale datasets. Results show that ThunderSecure can recognize science data traffic that are captured long after the training and make nearly certain detection on those with anomalous flows injected, even in the case when the anomaly-to-normal mixing ratio is 0.1%.

Gong, Qian↗

A Novel Technique for Distributed Measuring of Strain in the Vadose Zone

Characterizing water content and pressure changes in the vadose zone is important to understanding a variety of geologic processes, ranging from permeability, to evapotranspiration, and aquifer recharge. Changes in water content, or pressure, cause strain in the solid porous medium of the vadose zone, and it is possible that measuring those strains could be used a characterization tool. The Coherence-length-gated Microwave Photonics Interferometry (CMPI) technique measures strain at high resolution along many intervals defined by pairs of reflectors distributed along an optical fiber. This technique has recently been developed at Clemson University, and it has the spatial, and temporal resolution to characterize the strains that are expected to occur with hydrologic changes in the vadose zone. However, the technique has never been used to measure strain in porous media, so its capabilities remain uncertain. The objective of this thesis is to evaluate the ability of using CMPI to measure strain changes in the vadose zone. The research approach consists of conducting laboratory tests using a column filled with sand that was subjected to changes in water content and pressure. An optical fiber with CMPI reflectors was deployed in a high surface area ribbon and used to measure strain along the axis of the column. The column was made from 8-inch, Schedule 40 PVC pipe (75 cm tall, 20 cm inner diameter) and filled with medium-grained sand (K = 2.5x10-6 m/s, porosity = 0.28, Coefficient of Uniformity = 2, van Genuchten (n = 4.34 and  = 0.00039 m-1), Young’s Modulus = 18 – 47 MPa). Five pressure and four temperature sensors attached to probes inserted into the wall. The optical fiber includes five reflectors spaced 10 cm apart on the inside and outside of the column along the vertical axis. Strain measurements are made between pairs of reflectors. The reflectors are created in 250-micron-diameter acrylate-coated single mode Corning SMF28e+ optical fiber using a femtosecond laser. The optical fiber was laminated between two pieces of polyester film creating a large surface area to transfer strain from the porous media to the optical fiber. The experiments were conducted by filling the column from the bottom or infiltrating water from the top. The water was allowed to equilibrate to room temperature prior to each test in order to limit thermoelastic strain. Five injection tests with a rate of 250 ml/min and three infiltration tests at varying rates were conducted, and the results show patterns of strain and pressure are generally similar. Hydrologic conditions define three zones based on the pressure magnitude and distribution. 1.) Ambient Zone where the pressure heads are quasi-static and the pressure gradient is roughly unity (head gradient of zero). This is the uppermost zone and is characterized by negative pressures. 2.) Transition Zone where the pressures increase from ambient to zero, are changing relatively rapidly and the pressure gradient is relatively steep (pressure head gradients of 2). The Transition zone is 10 to 15 cm thick. 3.) Positive Pressure Zone where the pressure is positive, the rate of change is slower than in the transition zone and the gradient is flatter (pressure head gradient 1.1 to 1.2). This is the lowest zone in the column. Injection of water causes the pressure to increase and the three zones to move upward. The Transition zone moves at a rate of approximately 0.0002 m/s +/- .00005, according to analyses of pressure profiles. This is the same as the average velocity of the water calculated as volumetric flux/effective porosity =5.4x10-5 m/s/0.28. Strain signals in the range of 10s  were observed with a noise level of generally less than 0.1  (signal to noise ratio of greater than 100) during injection and drainage. The spatial and temporal distributions of strain caused by injection depend on the location of the moving pressure zones. The locations of the different pressure zones were determined from pressure profiles at different times and these data were transferred to strain time series. This showed that strain in the Ambient pressure zone is either unchanged or slightly compressive, whereas strain in Transition zone is tensile and roughly proportional to the pressure change, and strain ranges from tensile to compressive in the Positive Pressure zone. In general, the strain is variable at the top of the Positive Pressure zone, but it appears to be consistently tensile lower in the zone. The spatial distribution of strain causes three distinct stages in the strain times series measured between pairs of CMPI reflectors. The strain is unchanged or slightly compressive during Stage 1, it increases (positive strain is tensile) approximately linearly at a rate of 0.02 to 0.03 μ/s during the Stage 2, and then flattens out in Stage 3. The strain increases again during Stage 4 of the time series. The pressure also changes in stages. It is unchanged during Stage 1 and then increases relatively rapidly at a rate of between 4 and 10 Pa/s during Stage 2 and continues to increase during Stages 3 and 4, but at a rate slightly slower than during Stage 2 (from 2.5 to 3.5 Pa/s). The rates of pressure and strain change are consistent with basic analyses. The rate of pressurization is similar to the calculated velocity of flow in the saturated zone, and this is similar to the measured velocity of the strain increase. The ratio of the pressurization rate and strain rate during Stage 2 (2.5 (Pa/s) /0.03 (μ/s)) is 80 MPa, which is approximately equal to the upper range expected considering the uniaxial compression and the Young’s Modulus of the sand. An interesting effect occurs when the upper surface of the sand becomes saturated. Significant compression (several 10s of ) occurs as the pressure and saturation increase at the upper surface. Compression occurs throughout the column, but the effect is greatest at the top of the column. The rate of compression is fastest slightly before ponding occurs, but it slows markedly and nearly stops when water starts to accumulate at the surface (ponding). This effect reverses when the surface of the sand is drained, resulting in tension throughout the column. The compression caused by this effect can be as large or larger than the tensile strain that accumulated during filling. This effect was unexpected because increasing pressure is normally associated with tensile strain. Nevertheless, this effect was observed consistently in all tests where the pressure changes at the upper surface, including tests where water was injected from below or infiltrated from above. This effect behaves as if the pore pressure at the upper surface of the sand exerts a normal force on the boundary (increasing pore pressure exerts a downward compression on the boundary). The results of these laboratory experiments indicate that CMPI can measure strain caused by fluid pressure changes in the vadose zone with a signal to noise ratio of 100 or more. Injection and drainage cause a strain signal that is complex, but repeatable. The magnitudes of the strain signal are consistent with magnitudes that are expected based on poroelastic calculations using independently measured properties of the sand. These results indicate that the CMPI technique with an optical fiber laminated in a polyester ribbon generates data that represent the strain distribution during hydrologic processes of imbibition and drainage in variably saturated sand. This suggests that distributed strain measurements using CMPI could be a viable approach for evaluating processes in the vadose zone, laying the groundwork for future field implementation.

47 OTHER INSTRUMENTATION↗

Federated Learning with Frequency Estimation for Smart Meter Systems

Federated learning (FL) is a powerful framework that enables multiple distributed clients to collaborate without the need to transfer their data to a central server. However, FL does not inherently guarantee the level of privacy that clients often require. In our review of recent studies on privacy-enhancing techniques in FL, we found that frequency estimation (FE) methods remain underexplored. To address this gap, we developed and integrated FE techniques on the client side, further examining the effects of incorporating an adaptive range and a shuffled model. We also analyzed the impact of varying hyper-parameters on privacy preservation. Our results provide clear guidance on the algorithms and configurations that are most effective for enhancing privacy in FL, particularly when using long short-term memory (LSTM) architectures.

Kotevska, Olivera [ORNL] (ORCID:0000000316772243)↗