Optimization of a fuel ignition testing device for maximum data quality and utility
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Explore the source record for details and available documents.
Human performance in orbit is currently limited by several factors beyond the intrinsic awkwardness of motor control in weightlessness. Cognitive functioning can be affected by such factors as cumulative sleep loss, stress and the psychological effects of long-duration small-group isolation. When an astronaut operates a scientific experiment, the performance decrement associated with such factors can lead to lost or poor quality data and even the total loss of a scientific objective, at great cost to the sponsors and to the dismay of the Principal Investigator. In long-duration flights, as anticipated on the International Space Station and on any planetary exploration, the experimental model is further complicated by long delays between training and experiment, and the large number of experiments each crew member must perform. Although no documented studies have been published on the subject, astronauts report that an unusually large number of simple errors are made in space. Whether a result of the effects of microgravity, accumulated fatigue, stress or other factors, this pattern of increased error supports the need for a computerized decision-making aid for astronauts performing experiments. Artificial intelligence and expert systems might serve as powerful tools for assisting experiments in space. Those conducting space experiments typically need assistance exactly when the planned checklist does not apply. Expert systems, which use bits of human knowledge and human methods to respond appropriately to unusual situations, have a flexibility that is highly desirable in circumstances where an invariably predictable course of action/response does not exist. Frequently the human expert on the ground is unavailable, lacking the latest information, or not consulted by the astronaut conducting the experiment. In response to these issues, we have developed "Principal Investigator-in-a-Box," or [PI], to capture the reasoning process of the real expert, the Principal Investigator, and combine that with real-time data available in space in order to advise the astronaut about how to proceed in real time. [PI] advises the astronaut during the progress of an experiment in much the same way a real Principal Investigator might do while looking over the astronaut's shoulder. In its original application, [PI] mimicked several of the tasks of the Principal Investigator, including data quality monitoring, troubleshooting, prescheduling, protocol management and "interesting data" detection. The proposed research focuses on the efficacy of this technique as applied to the data quality monitoring and troubleshooting aspects of [PI].
ABSTRACT Introduction Presently, traumatic brain injury (TBI) triage in field settings relies on symptom-based screening tools such as the updated Military Acute Concussion Evaluation. Objective eye-tracking may provide an alternative means of neurotrauma screening due to sensitivity to neurotrauma brain-health changes. Previously, the US Army Medical Research and Development Command Non-Invasive NeuroAssessment Devices (NINAD) Integrated Product Team identified 3 commercially available eye-tracking devices (SyncThink EYE-SYNC, Oculogica EyeBOX, NeuroKinetics IPAS) as meeting criteria toward being operationally effective in the detection of TBI in service members. We compared these devices to assess their relative performance in the classification of mild traumatic brain injury (mTBI) subjects versus normal healthy controls. Materials and Methods Participants 18 to 45 years of age were assigned to Acute mTBI, Chronic mTBI, or Control group per study criteria. Each completed a TBI assessment protocol with all 3 devices counterbalanced across participants. Acute mTBI participants were tested within 72 hours following injury whereas time since last injury for the Chronic mTBI group ranged from months to years. Discriminant analysis was undertaken to determine device classification performance in separating TBI subjects from controls. Area Under the Curves (AUCs) were calculated and used to compare the accuracy of device performance. Device-related factors including data quality, the need to repeat tests, and technical issues experienced were aggregated for reporting. Results A total of 63 participants were recruited as Acute mTBI subjects, 34 as Chronic mTBI subjects, and 119 participants without history of TBI as controls. To maximize outcomes, poorer quality data were excluded from analysis using specific criteria where possible. Final analysis utilized 49 (43 male/6 female, mean [x̅] age = 24.3 years, SD [s] = 5.1) Acute mTBI subjects, and 34 (33 male/1 female, x̅ age = 38.8 years, s = 3.9) Chronic mTBI subjects were age- and gender-matched as closely as possible with Control subjects. AUCs obtained with 80% of total dataset ranged from 0.690 to 0.950 for the Acute Group and from 0.753 to 0.811 for the Chronic mTBI group. Validation with the remaining 20% of dataset produced AUCs ranging from 0.600 to 0.750 for Acute mTBI group and 0.490 to 0.571 for the Chronic mTBI group. Conclusions Potential eye-tracking detection of mTBI, per training model outcomes, ranged from acceptable to excellent for the Acute mTBI group; however, it was less consistent for the Chronic mTBI group. The self-imposed targeted performance (AUC of 0.850) appears achievable, but further device improvements and research are necessary. Discriminant analysis models differed for the Acute versus Chronic mTBI groups, suggesting performance differences in eye-tracking. Although eye-tracking demonstrated sensitivity in the Chronic group, a more rigorous and/or longitudinal study design is required to evaluate this observation. mTBI injuries were not controlled for this study, potentially reducing eye-tracking assessment sensitivity. Overall, these findings indicate that while eye-tracking remains a viable means of mTBI screening, device-specific variability in data quality, length of testing, and ease of use must be addressed to achieve NINAD objectives and DoD implementation.
The current trend in Big Data Analytics and in particular Health information technology is towards building sophisticated models, methods and tools for business, operational and clinical intelligence, but the critical issue of data quality required for these models is not getting the attention it deserves. The objective of the paper is to highlight the issues of data quality in the context of Big Data Healthcare Analytics.
Not provided.
Despite challenges with data quality and scope, low-cost sensor networks have skyrocketed in popularity over the last 15 years, making air quality data available on refined spatial scales. More recently, studies have leveraged both high and low-quality instruments to create stronger “hybrid” models, with most studies focusing on particulate matter. Low-cost measurements typically represent ground-level emissions only, providing context for human health issues from climate change-driven events such as wildfires. Since low-cost sensors’ capabilities are localized, daily events and microclimates tend to dominate the data rather than larger regional or atmospheric trends. Likewise, their low cost explains their high uncertainty. In contrast, some regulatory-grade instruments produce column measurements as well, providing reliable information on a broader scope. To bridge this gap while expanding into gas-phase measurements, we deployed 12 air quality sensor packages in California, USA during the 2022 wildfire season. These INSTEP (Inexpensive Network Sensor Technology Exploring Pollution) monitors measure carbon monoxide (CO), carbon dioxide (CO2), ozone (O3), nitrogen dioxide (NO2), and several hydrocarbons including methane (CH4) and formaldehyde (HCHO). Half of the monitors were co-located with remote sensing spectrometers: NASA Pandora and Total Column Carbon Observing Network (TCCON). The overlap in pollutants includes NO2, O3, and HCHO between the INSTEP monitors and the Pandora column measurements. TCCON covers column CO, CO2, and CH4, rounding out our comparison. Most of the monitors were distributed throughout the San Francisco Bay area, and an additional three were located within 100 km of Los Angeles. The sites ranged in geographic and population characteristics, including desert, mountainous, coastal, and urban locations. Since varying environmental conditions such as temperature and pressure are known to challenge sensor performance, we will apply newer sensor “calibration” techniques meant to combat this. We will normalize our sensor signals by z-scoring them prior to applying a single calibration model in the form of multivariate linear regression or an artificial neural network. While this technique has been validated for the hydrocarbon and ozone sensor types (metal oxide), it has not yet been tested on electrochemical and non-dispersive infrared sensors, which are also used in the INSTEP monitors. This will serve as a test to see if this normalization technique – or another – is most effective in accounting for environmental differences among sensors. Related data analysis efforts have found success with a variety of geospatial analysis techniques, including weighted network models in which high-quality instruments are given higher weights than their low-cost counterparts. Our preliminary analysis will focus on kriging, which uses a Gaussian algorithm to assign weights, providing estimated pollution levels at locations between monitors. Smoke trajectory and evolution will also be considered using both measurement types. We also aim to baseline subtract our emission estimates from each region to determine which portion of emissions are regional and local, further characterizing burn differences in northern and southern California fires. Future directions include using INSTEP jointly with TEMPO satellite data, and mobile deployments on aircraft and uncrewed aerial vehicles (UAV).
An algorithm is introduced to generate the optimal schedule of observations for a multi-user, multi-tasking automatic robotic telescope. The schedule is optimal m that it will take the highest possible quality data, perform the largest number of tasks, and fairly serve multiple users in terms of data quality, allocated telescope time, and observation priorities. In addition, the algorithm addresses problems due to overloading and underloading the telescope. The algorithm, which employs dynamic-programming-based decision theory, is analytically proven to produce the optimal schedule using set theory. Simulations conducted using actual astronomical data are presented which show significant improvement over existing scheduling techniques. Once completed the new scheduling algorithm will be tested on the Tennessee State University/Harvard-Smithsonian Center for Astrophysics 32-inch automatic Photoelectric Telescope at Fairborn Observatory, Arizona.
Dual beam depth profiling strategy has been widely adopted in ToF-SIMS depth profiling, in which two basic operation modes, interlaced mode and non-interlaced mode, are commonly used. Generally, interlaced mode is recommended for conductive or semi-conductive samples, whereas non-interlaced mode is recommended for insulating samples, where charge compensation can be an issue. Recent publications, however, show that the interlaced mode can be used effectively for glass depth profiling, despite the fact that glass is an insulator. In this study, we provide a simple guide for choosing between interlaced mode and non-interlaced mode for insulator depth profiling. Two representative cases are presented: (1) depth profiling of a leached glass sample, and (2) depth profiling of a single crystal MgO sample. In brief, the interlaced mode should be attempted first, because (1) it may provide reasonable-quality data, and (2) it is time-saving for most cases, and (3) it introduces low H/C/O background. If data quality is the top priority and measurement time is flexible, non-interlaced mode is recommended because interlaced mode may suffer from low signal intensity and poor mass resolution. A big challenge is tracking trace H/C/O in a highly insulating sample (e.g., MgO), because non-interlaced mode may introduce strong H/C/O background but interlaced mode may suffer from low signal intensity. Meanwhile, a C or Au coating is found to be very effective to improve the signal intensity. Surprisingly, the best analyzing location is not on the C or Au coating, but at the edge (outside) of the coating.
There is an urgency to advancing wastewater technologies due to aging water infrastructure and emerging regulations. A crosscutting working group proposes a conceptual design for a test bed network to understand and evaluate wastewater technologies to drive acceptance and deployment of new technologies to enhance performance. The working group includes contributors from the U.S. Department of Energy, the U.S. Environmental Protection Agency, the U.S. National Science Foundation, and the Water Research Foundation (formerly known as the Water Environment & Reuse Foundation). Upgrading today's aging wastewater treatment infrastructure to a new generation of water resource recovery facilities (WRRFs) requires the development and deployment of innovative technologies. The path to technology adoption depends on expensive, time consuming, and often repetitive cycles of testing and validation. Existing water resource recovery technology testing facilities (e.g., test beds) are underutilized and cannot, by themselves, broaden technology uptake. It has been proposed that technology adoption could be accelerated by a network linking these test facilities with innovators, manufacturers, utilities, regulators, policymakers, and educators. This document proposes a structure for a National Test bed Network (TBN) for water resource recovery. The concepts for its operation are explored herein. This document identifies drivers to launch a TBN and critical needs for successful implementation of the network. An important driver to technology implementation at WRRFs is the relationship between local utilities and state regulators. The TBN could provide access to validated performance data and facilitate deployment. To link the stakeholders and accelerate deployment, the TBN will require standards for methods, data quality, data management, and data security. These standards will enable validation of performance and will expand the “toolbox” that utilities and regulators could consider. Design, set up, and launch of this toolbox is beyond the scope of operations of utilities and regulators and will likely require external support to achieve full operation. Herein, a pathway is proposed to achieve this full operation. This document defines the function of a WRRF TBN. It also proposes a structure for the TBN to achieve its stated goals and mission. Finally, this document summarizes findings from several sources, including a series of workshops about the TBN concept, operators of test beds in ancillary industries, and discussions with regulators and permitting agencies. A description of this work was published in the peer-reviewed literature (Mihelcic 2017).
The radiometric data quality of the LANDSAT 4 multispectral scanner (MSS) was examined using several LANDSAT 4 frames. It was found that LANDSAT 4 MSS produces high-quality data of the caliber experienced with previous LANDSATS. For example, the detector equalization procedure worked well, leaving a residual banding effect of about 0.3 digital counts RMS, close to the theoretical minimum value of quantization error. Nevertheless, artifacts of the data were found, two of which were not experienced in previous MSS data. A low-level coherent noise effect was observed in all bands, with a magnitude of about 0.5 digital counts and a frequency of approximately 28 KHz (representing a wavelength of about 3.6 pixels); a substantial increase in processing complexity would be required to reduce this artifact in the data. Also, a substantial scan-length variation (of up to six pixels) was noted in MSS data when the TM sensor was operating; the LANDSAT 4 correction algorithms being applied routinely by the EROS Data Center to produce a p-type data should remove most of this variation. Between-satellite calibrations were examined in paired LANDSAT 3 and LANDSAT 4 MSS data sets, which were closely matched in acquisition time and place. Radiometric comparisons showed that all bands were highly linear in digital counts, and a well-determined linear transformation between the MSS's was established.