Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “data protection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Analysis of Air-Purifying Respirator (APR) and Powered Air-Purifying Respirator (PAPR) Cartridge Performance Testing on a Hanford AX Tank Farm Exhauster Slipstream Volume 2: Raw Analytical Data

As the Tank Operations Contractor for U.S. Department of Energy operations at the Hanford site in Washington State, Washington River Protection Solutions (WRPS) is responsible for managing highly radioactive wastes stored in tanks at Hanford. To protect workers at Hanford Tank Farms, WRPS tests air-purifying respirator (APR) and powered air-purifying respirator (PAPR) chemical cartridges commonly used at the tank farms. The tests were conducted to determine the period of time the cartridges would provide adequate performance for APRs and PAPRs when workers are exposed to a mixture of Chemicals of Potential Concern (COPC) from any vapors exiting headspaces in the storage tanks. Occupational Safety and Health Administration (OSHA) Standard 29 Code of the Federal Regulations (CFR) 1910.134(d)(3)(iii)(b)(2) specifies that for protection against gases and vapors, employers shall implement a schedule for cartridges to ensure that change-outs occur before the end of service life. The change schedule can be based on objective information or data that ensures cartridge change-outs occur before the end of their service life. The primary function of the WRPS Cartridge Test Program is to obtain objective data to determine service lives for the APR and PAPR cartridges used at Hanford Tank Farms. WRPS contracted with Pacific Northwest National Laboratory to analyze the test data and offer an independent analysis and any recommendations. This report summarizes data analysis of APR and PAPR cartridge testing on a vapor slipstream from the Hanford AX tank farm exhauster. Volume 1 of this report documents the testing, data analysis, results, conclusions, and recommendations resulting from the cartridge testing on AX exhauster slipstream vapors. Volume 2 provides an introduction to the raw data, including analytical laboratory analysis results that supported the analysis and conclusions documented in Volume 1.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Powered Air-Purifying Respirator (PAPR) Cartridge Performance Testing on Hanford Tanks SX-101 and SX-104: Volume 2 Raw Analytical Data

As the Tank Operations Contractor for U.S. Department of Energy operations at the Hanford site in Washington State, Washington River Protection Solutions (WRPS) is responsible for managing highly radioactive wastes stored in tanks at Hanford. WRPS tests of cartridges used in air-purifying respirators (APR) and powered air-purifying respirators (PAPR) commonly used at Hanford Tank Farms. The tests are conducted to determine the period of time the cartridges would provide adequate performance for APRs and PAPRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from any vapors exiting headspaces in the storage tanks. Occupational Safety and Health Administration (OSHA) Standard 29 Code of the Federal Regulations (CFR) 1910.134(d)(3)(iii)(b)(2) specifies that for protection against gases and vapors, employers shall implement a schedule for cartridges to ensure that change-outs occur before the end of service life. The change schedule can be based on objective information or data that ensures cartridge change-outs occur before the end of their service life. The primary function of the WRPS Cartridge Test Program is to obtain objective data to determine service lives for the APR and PAPR cartridges used at Hanford Tank Farms. WRPS contracted with Pacific Northwest National Laboratory to analyze the test data and offer an independent analysis and any recommendations. This report summarizes data analysis of PAPR cartridge testing on headspace vapors from Hanford SX-101 and SX-104 single-shell tanks. Two different PAPR cartridges—one from MSA Safety Inc. (Pittsburgh, Pennsylvania) and another from 3M (Maplewood, Minnesota)—were assessed on each tank headspace source on separate days. These data represent the first PAPR cartridge testing under the recent WRPS program, as testing to date had been focused on APR cartridges. Volume 1 of this report documents the testing, data analysis, results, conclusions, and recommendations resulting from the PAPR testing on SX-101 and SX-104 headspace vapors. Volume 2 provides an introduction to the raw data, including analytical laboratory analysis results that supported the analysis and conclusions documented in Volume 1.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Air-Purifying Respirator (APR) and Powered Air-Purifying Respirator (PAPR) Cartridge Performance Testing on Hanford Tanks BY-108 and BY-110 Volume 2: Raw Analytical Data

As the Tank Operations Contractor for U.S. Department of Energy operations at the Hanford site in Washington State, Washington River Protection Solutions (WRPS) is responsible for managing highly radioactive wastes stored in tanks at Hanford. WRPS tests air-purifying respirator (APR) and powered air-purifying respirator (PAPR) chemical cartridges commonly used by workers at Hanford Tank Farms to determine the period of time that the cartridges would provide adequate performance for APRs and PAPRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from any vapors exiting headspaces in the storage tanks. The Occupational Safety and Health Administration (OSHA) Standard promulgated in Title 29 of the Code of the Federal Regulations (CFR) 1910.134(d)(3)(iii)(b)(2) specifies that for protection against gases and vapors, employers shall implement a schedule for cartridges to ensure that change-outs occur before the end of service life. The change schedule can be based on objective information or data that ensures cartridge change-outs occur before the end of their service life. The primary function of the WRPS Cartridge Test Program is to obtain objective data to determine service lives for the APR and PAPR cartridges used at Hanford Tank Farms. WRPS contracted with Pacific Northwest National Laboratory to analyze the test data and offer an independent analysis and any recommendations. This report summarizes data analysis of APR and PAPR cartridge testing on BY-110 and BY-108 headspace vapors, respectively. Two different APR cartridges from SCOTT Safety (Monroe, North Carolina) were assessed for the BY-110 headspace vapors, and two different PAPR cartridges—one from MSA Safety Inc. (Pittsburgh, Pennsylvania) and another from 3M (Maplewood, Minnesota)—were assessed for the BY-108 headspace vapors. Volume 1 of this report documents the testing, data analysis, results, conclusions, and recommendations resulting from the cartridge testing of vapors from the BY-110 and BY-108 headspaces. Volume 2 provides an introduction to the raw data, including analytical laboratory analysis results that supported the analysis and conclusions documented in Volume 1.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Energetic Tug-of-War between Pt and Leaky TiO 2 : Positive and Negative Effects on the Function of Molecularly-Modified p -Si(111)|TiO 2 |Pt Photocathodes

Photoelectrochemical solar energy conversion to chemical products is a promising avenue towards renewable fuels, and TiO 2 deposition on semiconductor photocathodes is a widespread surface protection strategy. However, the electronic, thermodynamic, and kinetic effects of protection layers on interfacial energetics remains poorly understood. Here, electrochemical data (photocurrent onset and flatband potentials) of p-Si(111)|TiO 2 |Pt is collected in contact with an outer-sphere redox couple. We find that onset potentials shift negatively as a function of increasing oxide thickness, but this effect is not reflected in the flatband potentials. This reveals the mechanism of these shifts is kinetic rather than thermodynamic,and suggests that hole leakage through the TiO 2 is responsible. When Pt nanoparticles are deposited onto the TiO 2 , positive shifts in both the onset and flatband potentials are observed, revealing Pt catalysts are beneficial for more than just increased catalytic rates. These results highlight the importance of understanding the effects of surface modifications on the energetics at the interface in both catalytic and simple electron transfer systems.

14 SOLAR ENERGY↗

Diverse array of neutralizing antibodies elicited upon Spike Ferritin Nanoparticle vaccination in rhesus macaques

The repeat emergence of SARS-CoV-2 variants of concern (VoC) with decreased susceptibility to vaccine-elicited antibodies highlights the need to develop next-generation vaccine candidates that confer broad protection. Here we describe the antibody response induced by the SARS-CoV-2 Spike Ferritin Nanoparticle (SpFN) vaccine candidate adjuvanted with the Army Liposomal Formulation including QS21 (ALFQ) in non-human primates. By isolating and characterizing several monoclonal antibodies directed against the Spike Receptor Binding Domain (RBD), N-Terminal Domain (NTD), or the S2 Domain, we define the molecular recognition of vaccine-elicited cross-reactive monoclonal antibodies (mAbs) elicited by SpFN. We identify six neutralizing antibodies with broad sarbecovirus cross-reactivity that recapitulate serum polyclonal antibody responses. In particular, RBD mAb WRAIR-5001 binds to the conserved cryptic region with high affinity to sarbecovirus clades 1 and 2, including Omicron variants, while mAb WRAIR-5021 offers complete protection from B.1.617.2 (Delta) in a murine challenge study. Our data further highlight the ability of SpFN vaccination to stimulate cross-reactive B cells targeting conserved regions of the Spike with activity against SARS CoV-1 and SARS-CoV-2 variants.

59 BASIC BIOLOGICAL SCIENCES↗

Structure-function analysis of microRNA 3'-end trimming by Nibbler

Nibbler (Nbr) is a 3'-to-5' exoribonuclease whose catalytic 3'-end trimming activity impacts microRNA (miRNA) and PIWI-interacting RNA (piRNA) biogenesis. Here, we report on structural and functional studies to decipher the contributions of Nbr’s N-terminal domain (NTD) and exonucleolytic domain (EXO) in miRNA 3'-end trimming. We have solved the crystal structures of the NTD core and EXO domains of Nbr, both in the apo-state. The NTD-core domain of Aedes aegypti Nbr adopts a HEAT-like repeat scaffold with basic patches constituting an RNA-binding surface exhibiting a preference for binding double-strand RNA (dsRNA) over single-strand RNA (ssRNA). Structure-guided functional assays in Drosophila S2 cells confirmed a principal role of the NTD in exonucleolytic miRNA trimming, which depends on basic surface patches. Gain-of-function experiments revealed a potential role of the NTD in recruiting Nbr to Argonaute-bound small RNA substrates. The EXO domain of A. aegypti and Drosophila melanogaster Nbr adopt a mixed α/β-scaffold with a deep pocket lined by a DEDDy catalytic cleavage motif. We demonstrate that Nbr’s EXO domain exhibits Mn2+-dependent ssRNA-specific 3'-to-5' exoribonuclease activity. Modeling of a 3' terminal Uridine into the catalytic pocket of Nbr EXO indicates that 2'-O-methylation of the 3'-U would result in a steric clash with a tryptophan side chain, suggesting that 2'-O-methylation protects small RNAs from Nbr-mediated trimming. Overall, our data establish that Nbr requires its NTD as a substrate recruitment platform to execute exonucleolytic miRNA maturation, catalyzed by the ribonuclease EXO domain.

59 BASIC BIOLOGICAL SCIENCES↗

Study of electron-induced chemical transformations in polymers

In extreme ultraviolet (EUV) photoresist exposure, the primary and secondary electrons drive chemistry rather than the EUV photons themselves. These electrons have a wide range of energies below approximately 80 eV, which are capable of complex network of reactions during exposure. To better understand the ability of electrons of different energies within the EUV primary and secondary electron range, we want to characterize and compare the chemistry induced in pure polymer films by direct exposure to electrons. Thin films of poly(tert-butyl methacrylate), poly(methyl methacrylate), and poly(4-hydroxystyrene) were exposed to a 20 to 80 eV electron beam. Outgassing during exposure was characterized in-situ using a quadrupole residual gas analyzer. The thickness changes were measured using ellipsometry and chemical bond structure data were collected using Fourier-transform infrared spectroscopy (FTIR) after exposure to compare different exposure conditions. Poly(4-hydroxystyrene) demonstrated stability during electron exposures. Exposures of the other two materials led to outgassing of protecting groups, the intensity of which decayed in time. Outgassing, FTIR, and thickness loss data exhibited approximately linear relationships to each other.

Mueller, Maximillian↗

LLNL Kimberlina 1.2 NUFT Simulations June 2018 (v2)

This dataset contains the output 6,000, 3-dimensional reactive multi-phase flow and transport aquifer simulations of brine and CO2 leakage into a protective aquiver in California’s San Joaquin Valley and input data files detailing the geologic mesh, aquifer physical properties and CO2 and brine injection rates. This data set was generated as an ongoing effort with the US DOE National Risk Assessment Partnership (NRAP) to evaluate the effectiveness of monitoring techniques to detect brine and CO2 leakage from legacy wells into underground sources of drinking water overlaying a CO2 storage reservoir. Each simulation contains a unique set of input parameters, generated stochastically. The outputs consist of these upper three geologic layers (from top): the Etchegoin, Macoma-Chanac, Santa Margarita-McLure formations. These simulations span the several distances (1, 3 and 6 km or wells W31-0.2, W31-0.5 and W31-1.0, respectively) from the CO2 injector, initiated from bottom hole pressure and saturation to calculate wellbore leakage from the storage reservoir, with low and high regional groundwater gradients and wellbore leakage into 5 leaky nodes. The dataset includes 1,000 unique simulations for each distance, which each contain a unique aquifer heterogeneity, aquifer and caprock permeability, and two model generations are included with a high permeability (prod07) and hybrid permeability (prod09). The range of permeability distributions is listed in Table 1. Each model generation consists of 3,000 simulations. Included in the dataset are the leakage rates determined from 2D wellbore models which utilize the pressure and CO2 saturation from LBL's reservoir simulations, NUFT mesh files with distributed lithology, NUFT rocktab files which describe the material properties for the geologic layers and the NUFT input files and post-processed output 'ntab' files. Each ntab file contains spatial (rows) and temporal (columns) model output tables for each model cell, the locations (x,y,z) and dimensions for each cells (dx, dy, dz). Table 1. Permeability distribution ranges for prod07 and prod09 model generations Geologic Layer: Permeability Range (log10 m^2) prod07 prod09 Etchegoin -12.92 to -10.92 -13.70 to -11.44 Macoma-Chanac -12.72 to -10.72 -13.50 to -11.24 Santa Margarita-McLure -12.70 to -10.70 -13.48 to -11.22 The input files used to generate the model include which are included in the dataset are: Time series of CO2 leakage input into the model (ex: Q_brn.W31-0.2.sim1000.layers123.tab) Time series of CO2 leakage input into the model (ex: Q_CO2.W31-0.2.sim1000.layers123.tab) Physical properties of the aquifer materials detailing the aquifer porosity, solid density, partitioning coefficients, permeabilities and van-Genuchten parameters detailed in a NUFT rocktab file: (ex: sim1000.usnt.rocktab) Numerical mesh and geologic data assigned to each model cell detailed in a NUFT genmsh format (ex: sim1000.mesh_k16.prod07.trans.genmsh) The primary output parameters are: pH (use absolute value) Change in TDS (mg/kg) Change in Pressure (Pa) Change CO2 gas saturation (fraction range 0.0-1.0) for example, the directory /p/lscratchh/mansoor1/nrap/kimberlina/prod09/mainfiles/sim1000/W31- 0.2 contains: sim1000.W31-0.2.trans.pH.red.ntab sim1000.W31-0.2.no_bg.trans.TDS.red.ntab sim1000.W31-0.2.usnt.P.deltabg.red.ntab sim1000.W31-0.2.usnt.CO2_sat.deltabg.red.ntab Each row in the NTAB files consist of model output per numerical grid cell. Each output file contains 33 columns (variables), including the information of numerical records, geologic location and sizes and the simulated parameter values over time. The first 13 variables are about numerical records and relative geologic information for a simulation grid: 1. index: simulation index 2. i: the ith grid of x-axis 3. j: the ith grid of y-axis 4. k: the ith grid of z-axis 5. element_ref: element reference 6. nuft_ind: nuft index 7. x: grid location in the x axis direction 8. y: grid location in the y axis direction 9. z: grid location in the z axis direction 10. dx: grid length in the x axis direction 11. dy: grid length in the y axis direction 12. dz: grid length in the z axis direction 13. volume: volume of the simulation grid The remainder (14, 15, 16...) variables are the simulated parameter values over time, take Pressure as an example, are: 14. 0.0y: initial pressure per cell. 15. 10.0y: simulated pressure at the end of the 10th year. 16. 20.0y: simulated pressure at the end of the 20th year. ... (repeated for every 10 years until 200 years)... The model extends 10,000 m, 5,000 m and 1,411 m in the x,y and z dimensions, respectively. The mesh consists of 164,832 cells with mesh dimensions of 101 x 51 x 32 (nx, ny, nz), with cell dimensions ranging from 100 m laterally (along x and y-axis) and model layers are as designated in the z-axis: Layer 1: atmosphere (1e-30 m thick) Layer 2: upper caprock (10 m thick) Layers 3-13: Etchegoin (536.23 m thck) Layers 14-27: Macoma-Chanac (679.04 m thick) Layers 28-32: Santa Margarita-McLure (185.94 m thick) The wellbore is placed along node i=51, j=26, and extends vertically along 5 nodes from the top to the bottom of the model. Special instructions when extracting files: Each Gzip archive (ex: prod07.sim1000-sim00099.tar.gz) contains 100 simulations. Gzip archives should be transferred into base directories (ie. In Linux: mkdir prod07; mv prod07.*.tar.gz prod07/.) before extracting, or files will be overwritten. Each sub-simulation tree should have the following file structure pattern (using the linux 'tree' command): |-- prod07 | |-- sim0001 | |-- W31-0.2 | | |-- Q_brn.W31-0.2.sim0001.layers123.tab | | |-- Q_co2.W31-0.2.sim0001.layers123.tab | | |-- sim0001.W31-0.2.no_bg.trans.TDS.red.ntab | | |-- sim0001.W31-0.2.trans.pH.red.ntab | | |-- sim0001.W31-0.2.usnt.CO2_sat.deltabg.red.ntab | | |-- sim0001.W31-0.2.usnt.P.deltabg.red.ntab | |-- W31-0.5 | | |-- Q_brn.W31-0.5.sim0001.layers123.tab | | |-- Q_co2.W31-0.5.sim0001.layers123.tab | | |-- sim0001.W31-0.5.no_bg.trans.TDS.red.ntab | | |-- sim0001.W31-0.5.trans.pH.red.ntab | | |-- sim0001.W31-0.5.usnt.CO2_sat.deltabg.red.ntab | | |-- sim0001.W31-0.5.usnt.P.deltabg.red.ntab | |-- W31-1.0 | | |-- Q_brn.W31-1.0.sim0001.layers123.tab | | |-- Q_co2.W31-1.0.sim0001.layers123.tab | | |-- sim0001.W31-1.0.no_bg.trans.TDS.red.ntab | | |-- sim0001.W31-1.0.trans.pH.red.ntab | | |-- sim0001.W31-1.0.usnt.CO2_sat.deltabg.red.ntab | | |-- sim0001.W31-1.0.usnt.P.deltabg.red.ntab | |-- sim0001.mesh_k16.prod07.trans.genmsh Disclaimer This document was prepared as an account of work sponsored by an agency of the United States government. Neither the United States government nor Lawrence Livermore National Security, LLC, nor any of their employees makes any warranty, expressed or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States government or Lawrence Livermore National Security, LLC. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States government or Lawrence Livermore National Security, LLC, and shall not be used for advertising or product endorsement purposes. Lawrence Livermore National Laboratory is operated by Lawrence Livermore National Security, LLC, for the U.S. Department of Energy, National Nuclear Security Administration under Contract DE-AC52-07NA27344. This report was reviewed and released as LLNL-MI-753464.

aquifer↗

Underground Test Area (UGTA) Sampling Plan for Corrective Action Units 101 and 102: Central and Western Pahute Mesa, Nevada National Security Site, Nevada

The purpose of this groundwater sampling plan (referred to herein as “the Plan”) is to describe the approach for collecting and analyzing groundwater samples to meet the objectives of the U.S. Department of Energy (DOE), Environmental Management (EM) Nevada Program’s Underground Test Area (UGTA) Activity. The Plan is focused on the Central and Western Pahute Mesa corrective action units (CAUs 101 and 102). The remaining UGTA CAUs are in the final stage of the UGTA strategy (Closure Report [CR] stage), and monitoring requirements for these CAUs are described in their respective CRs. The Plan supersedes the Nevada National Security Site Integrated Groundwater Sampling Plan and its ensuing Record of Technical Change (ROTC) (DOE/EMNV, 2019b). The Plan is designed to ensure compliance with the UGTA Quality Assurance Plan (QAP) and its ensuing ROTC (DOE/EMNV, 2018), and the Federal Facility Agreement and Consent Order (FFACO) (1996, as amended). The Plan is implemented by the Environmental Program Services (EPS) contractor. Implementation of the Plan provides data to complete corrective actions prescribed by the FFACO to protect the public from groundwater contaminated by historical underground nuclear testing. The Plan’s scope comprises sample collection and analysis requirements for assessing the extent of groundwater contamination from underground nuclear testing. Sampling wells located in the communities surrounding the Nevada National Security Site (NNSS) is performed by other organizations (e.g., management and operating [M&O] contractor) and is therefore not included within the Plan. The results of the community sampling are presented in the annual NNSS environmental reports.

54 ENVIRONMENTAL SCIENCES↗

A Proposed Geospatial Data Preservation Strategy for DOE's Office of Legacy Management

Identifying and planning preservation and curation activities associated with geospatial data will improve the ability of the U.S. Department of Energy Office of Legacy Management (LM) to support their core mission of protecting human health and the environment. This report documents the development LM's strategy for preserving and curating geospatial data within the context of LM's data-lifecycle-management framework. The strategy consists of preservation and curation elements, specific activities, and key enabling factors that ensure LM's geospatial data is maintained. Preservation elements enable the effective preservation of LM's geospatial data and recognizes that strategies need to be flexible to adapt to ongoing changes in scale, technology, and standards. Key enabling factors are intended to highlight critical data management responsibilities that must be addressed by LM to meet its preservation and curation objectives. A summary of best practices for geospatial data preservation is provided as part of the strategy.

97 MATHEMATICS AND COMPUTING↗

CO2-Locate: A Dynamic Database and Tool for Accessing National Oil and Gas Well Data to Inform Carbon Storage Projects

The CO2-Locate Database is a growing compilation of publicly available wellbore resources that have been merged based on common attributes across data sources with an attribute schema developed to be consistent across disparate resources, reduce data gaps, and eliminate record redundancy. The first version of CO2-Locate has been published to Energy Data eXchange (EDX) and includes the integrated public wells dataset as well as additional geospatial summary layers of key wellbore characteristics to protect proprietary resources. Additionally, the CO2-Locate database has been deployed into a web application, enabling easy access, data filtering capabilities, and visualization of U.S. wellbore infrastructure by stakeholders to inform injection site selection and risk assessments.

Dyer, Alec S. [NETL Site Support Contractor, Natio↗

Alleviation of CCCP-induced mitochondrial injury by augmenter of liver regeneration via the PINK1/Parkin pathway-dependent mitophagy

The occurrence of liver diseases is attributed to mitochondrial damage. Mitophagy selectively removes dysfunctional mitochondria, thereby preserving mitochondrial function. Augmenter of liver regeneration (ALR) protects the mitochondria from injury. However, whether ALR protection is associated with mitophagy remains unclear. In this study, mitochondrial damage was induced by carbonyl cyanide 3-chlorophenylhydrazone (CCCP), and long-form ALR (lfRNA)-mediated protection against this damage was investigated. Treatment of HepG2 cells with CCCP elevated the level of intracellular ROS, inhibited ATP production, and increased the mitochondrial membrane potential and cell apoptotic rate. However, in lfALR-transfected cells, CCCP-induced cell injury was clearly alleviated, the apoptosis and ROS levels clearly declined, and the ATP production was significantly enhanced as compared with that in vector-Tx cells. Furthermore, lfALR overexpression promoted autophagy and mitophagy via a PINK1/Parkin-dependent pathway, whereas knockdown of ALR suppressed mitophagy. In lfALR-transfected cells, the phosphorylation of AKT was decreased, thus, downregulating the phosphorylation of the transcription factor FOXO3a at Ser315. In contrast, the phosphorylation of AMPK was enhanced, thereby upregulating the phosphorylation of FOXO3a at Ser413. Consequently, FOXO3a′s nuclear translocation and binding to the promoter region of PINK1 was enhanced, and the accumulation of PINK1/Parkin in mitochondria increased. Meanwhile, short-form ALR (sfALR) also increased PINK1 expression through FOXO3a with the similar pathway to lfALR. In conclusion, our data suggest a novel mechanism through which both lfALR and sfALR protect mitochondria by promoting PINK1/Parkin-dependent mitophagy through FOXO3a activation.

60 APPLIED LIFE SCIENCES↗

A High-Fidelity Cyber-Physical Testbed-Based Benchmarking Dataset For Testing Operational Technology Specific Intrusion Detection Systems

Quality datasets serve a critical purpose in cyber security research. Data is needed to understand system behavior and develop security controls to protect critical systems. However, for critical infrastructure operational environments there is a lack of available datasets to study because of the high cost and specialized capabilities necessary to generate them. This paper documents the development of a dataset of high fidelity hardware in the loop laboratory simulated models of electric and natural gas distribution systems with real cyber attack test cases. A deep dive discussion for the experimental setup and controls for generating the data is provided along with observations from using the data in evaluating intrusion detection approaches.

Ashok, Aditya↗

Analysis of Air-Purifying Respirator (APR) Cartridge Performance Testing on Hanford Tanks SX-101 and SX-104: Volume 2 - Raw Analytical Data

As the Tank Operations Contractor for U.S. Department of Energy operations at the Hanford site in Washington State, Washington River Protection Solutions (WRPS) is responsible for managing highly radioactive wastes stored in tanks at Hanford. To protect workers at Hanford Tank Farms, WRPS tests air-purifying respirator (APR) and powered air-purifying respirator (PAPR) chemical cartridges commonly used at the tank farms. The tests were conducted to determine the period of time the cartridges would provide adequate performance for APRs and PAPRs when workers are exposed to a mixture of Chemicals of Potential Concern (COPC) from any vapors exiting headspaces in the storage tanks. Occupational Safety and Health Administration (OSHA) Standard 29 Code of the Federal Regulations (CFR) 1910.134(d)(3)(iii)(b)(2) specifies that for protection against gases and vapors, employers shall implement a schedule for cartridges to ensure that change-outs occur before the end of service life. The change schedule can be based on objective information or data that ensures cartridge change-outs occur before the end of their service life. The primary function of the WRPS Cartridge Test Program is to obtain objective data to determine service lives for the APR and PAPR cartridges used at Hanford Tank Farms. WRPS contracted with Pacific Northwest National Laboratory to analyze the test data and offer an independent analysis and any recommendations. This report summarizes data analysis of APR cartridge testing on headspace vapors from Hanford SX-101 and SX-104 single-shell tanks. Volume 1 of this report documents the testing, data analysis, results, conclusions, and recommendations resulting from the APR testing on SX-101 and SX-104 headspace vapors. Volume 2 provides an introduction to the raw data, including analytical laboratory analysis results that supported the analysis and conclusions documented in Volume 1.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Annual PM2.5 and cardiovascular mortality rate data: Trends modified by county socioeconomic status in 2,132 US counties

This article contains data on county-level socioeconomic status for 2132 US counties and each county's average annual cardiovascular mortality rate (CMR) and fine particulate matter (PM2.5) concentration for 21 years (1990e2010). County CMR, PM2.5, and socioeconomic data were obtained from the US National Center for Health Statistics, US Environmental Protection Agency's Community Multiscale Air Quality modeling system, and the US Census, respectively. Annual socioeconomic indices were created using seven county-level measures from the 1990, 2000, and 2010 US Census using factor analysis. Quintiles of this index were used to generate categories of county socioeconomic status. This national data set contains data for annual PM2.5 and CMR changes over a time-period when there was a significant reduction in US air pollutants (following the enactment of the 1970 Clean Air Act). These data are associated with the article “The contribution of improved air quality to reduced cardiovascular mortality: Declines in socioeconomic differences over time” [1]. Data are stored in a comma separated value format and can be downloaded from the USEPA ScienceHub data repository (https://doi.org/10.23719/ 1506014).

Socioeconomic status↗

DOE CESER 6 GHz Interference Study

DOE CESER has sponsored Idaho National Laboratory (INL) to conduct an objective and independent study of potential 6 GHz interference from outdoor operation of unlicensed devices in the 6 GHz band on fixed service (FS) microwave communication links operated by electrical sector incumbents in that band. INL is collaborating with University of Notre Dame (UND), Electric Power Research Institute (EPRI), Lockard & White, Southern Company, and AT&T, to gather data with real-world 6 GHz interference experiments and identify (1) the potential for interference from unlicensed devices and (2) the interference necessary to cause harm to the incumbents. In addition to the functional assessment, a security assessment of the FCC mandated Automatic Frequency Coordination (AFC) System to regulate use of unlicensed 6 GHz standard power devices is also being conducted. A major objective is to create a science-based and defensible methodology used to produce the necessary data and to derive objective conclusions. This proven methodology can then be used to produce objective data and conclusions for other spectrum bands with similar incumbent uses including 4.4 – 4.9 GHz and 7.125 – 7.4 GHz, identified in the reconciliation bill that was adopted on July 4, 2025, as well as the National Spectrum Strategy discussions that are ongoing. This report contains 6 GHz field experiments and findings in the following real-world scenarios with commercial unlicensed standard power (SP) 6 GHz devices regulated by Automated Frequency Coordination (AFC): • University of Notre Dame (UND) Stadium with a capacity of 80,000 spectators, where Wi-Fi operating in 6 GHz has been deployed recently • Southern Company 6 GHz FS microwave link between Columbus and Fortson, Georgia Following are the following key findings from this study. 1. The AFC is under-protective of FS when line-of-sight exists along the path centerline. Data collected at Southern’s 6 GHz fixed link site shows significant erosion of as much as 21.4-24.4 dB of under-protection that can lead to potential service degradation under typical operating conditions. This first key finding is most likely the result of erroneous use of the RF propagation model. INL will collaborate with EPRI and the AFC Functional Requirements Working Group to submit a change request to the WinnForum TS-1014 standard towards correct use of the propagation model by the AFC. 2. There is additive interference effect of about 3 dB from nearly equal power interferers measured from simultaneous operation of two SP AP's operating co-channel with the FS receive from different locations along the path. This second key finding should be used to add the impact of additive interference of operation of multiple APs in the same geographical area, to the next generation of AFCs. INL will collaborate with FCC on the need for the AFC to consider additive interference. We also recommend that additional experiments are conducted on 6 GHz spectrum interference to further improve the AFC operation as the number of outdoor Wi-Fi devices continues to increase. These proposed steps and recommendations will make the co-existence of the incumbents and the 6 GHz outdoor Wi-Fi providers possible without any impact on the incumbents with a win-win outcome for all.

6 GHz↗