On an Information and Control Architecture for Future Electric Energy Systems
Not Available
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
Network segmentation of a power grid's communication system can make the grid more resilient to cyberattacks. Here we develop a novel trilevel programming model to optimally segment a grid communication system, taking into account the actions of an information technology (IT) administrator, attacker, and grid operator. The IT administrator is allowed to segment existing networks, and the attacker is given a budget to inflict damage on the grid by attacking the segmented communication system. Finally, the grid operator can redispatch the grid after the attack to minimize damage. The resulting problem is a trilevel interdiction problem that we solve using a branch and bound algorithm for bilevel problems. We demonstrate the benefits of optimal network segmentation through case studies on the 9-bus Western System Coordinating Council (WSCC) system and the 30-bus IEEE system. These examples illustrate that network segmentation can significantly reduce the threat posed by a cyberattacker.
Industrial control systems are subject to cyber attacks that produce physical consequences. These attacks can be both hard to detect and protracted. Here, we focus on deception-based sensor bias attacks made against a hierarchical control system where the attacker attempts to be stealthy. We develop a a data-driven, optimization-based attacker model and use the Koopman operator to represent the system dynamics in a domain-aware and computationally efficient manner. Using this model, we compute several different attacks against a high-fidelity commercial building emulator and compare the impacts of those attacks to each other. Finally, we discuss some computational considerations and identify avenues for future research.
Industrial Control Systems (ICS) are crucial for monitoring physical processes that support essential cyber-enabled services like power generation. The use of proprietary communication and lack of effective intrusion detection mechanisms pose constraints for efficient operation. Therefore, there is a need to modernize these systems with decentralized technologies like Edge Computing and 5G. However, integrating 5G and Edge Computing into large-scale ICS networks presents implementation and performance challenges. To address these challenges, this paper proposes an integrated ICS architecture that combines 5G and Edge Computing technologies with traditional ICS protocols. The objective is to minimize implementation and operational difficulties while improving the monitoring of physical processes and enabling robust intrusion detection. The proposed architecture outlines the necessary components, services, and communication protocols required for the integration of 5G and Edge Computing.
Not Available
Not Available
Smart buildings, especially Grid-interactive Efficient Buildings (GEBs), suffer from cyber-attacks and physical faults due to the integration of a large number of sensors and controls, connected devices, and associated communication networks. This study demonstrated a real-time advanced building resilient platform, called CYber Defense and REsilient System (CYDRES), which is deployable for existing and emerging Building Automation Systems (BASs). CYDRES aims to empower GEBs with cyber-attack-immune capabilities through multi-layer prevention and adaptation mechanisms to monitor, detect, and respond to cyber-attacks and physical operational faults. CYDRES is demonstrated through real-time experiments in a Hardware-in-the-Loop (HIL) testbed.
This dataset holds simulated PCAP (packet capture) data from the SCEPTRE validation demonstration model as a set of pairwise communications between devices via specific protocols. All connections should be assumed to be symmetric, as this data is an aggregation of the true PCAP. A mapping is also provided associating each IP address with its true device type.
The complex interdependencies of cyber systems (sensors and communications), physical grids and associated electricity market operations make protecting electric power grids a significant challenge. The energy sector is constantly under new, targeted, advanced and dangerous cyber-attacks that have the potential to result in the loss of human life. These threats are further exacerbated by our need to modernize the grid. One focus of cyber security research in smart grids is the securing of the SCADA system through advanced intrusion detection systems (IDS) and bad data detection algorithms in state estimation. These methods either require full knowledge of the system topology and parameters or fail to understand the physical behaviors under attack. WISP (Watching grid Infrastructure Stealthily through Proxies) is designed to provide additional protection to the power grid using only publicly available data. In particular, WISP exploits the spatio-temporal nature of the real time locational marginal prices (LMPs), in conjunction with other information such as bids, weather, outages and load data to analyze anomalous power pricing behaviors and then correlate those observations to localize regions of interest and identify potential cyber events. WISP is non-intrusive as the tool is deployed as a service in the Cloud or on premise and provides reliable information to system operators for enhanced situational awareness, without impeding energy delivery functions. The WISP technology comprises three modules: the data-driven anomaly detection core, the vulnerability and risk analysis and the root cause analysis. The data-driven anomaly detection core performs the tasks of feature selection, anomaly detection and attack region localization. The vulnerability and risk analysis module provides system level information of the vulnerable variables and times, assisting the operators in selecting monitoring and protection nodes. The root cause analysis module takes the detection results and identifies potential operational conditions that contribute to the detected anomalies. In Phase I, we have demonstrated the feasibility and effectiveness of WISP. We developed a realistic electricity market simulator capable of generating normal and attack market data under various operational conditions. We developed a series of cyber-attack detection and analysis algorithms and evaluated them under multiple data sources. Finally, we integrated all modules into an end-to-end software, providing functions for data management, data analytics and visualization. Specifically, we have achieved: (i) real-time data acceptance from external utility interfaces with >99% acceptance rate; (ii) high performance anomaly detection algorithms with >98% detection accuracy and <0.1% false alarm rate; and (iii) ultra-low computing delay <50 milliseconds. Additionally, our team developed algorithms to identify the vulnerable variables in electricity market operations and root cause analysis functions to identify major contributors to the price spikes. These ancillary modules are necessary when deploying WISP in real world industry environment. In Phase II, we have demonstrated the effectiveness of WISP software on realistic largescale power systems. We performed red team testing for the Phase I WISP software and identified software vulnerabilities and implemented corresponding mitigation solutions. We adapted the electricity market simulator for the Texas synthetic 2000-bus system and generated datasets for the false data injection attacks. We created database and visualization interfaces for the Texas system and the ISO New England system. We performed software optimization in terms of operation efficiency, computing speed and detection accuracy. Finally, we tested the software on the Texas system and the ISO New England system and evaluated the detection performance. Overall, we achieved above 89% detection rate, below 3% false alarm rate and below 37 seconds of end-to-end detection delay.
This document supports the application of Cyber-Informed Engineering (CIE) within the context of Enterprise Risk Management (ERM) to enhance cyber-resilience. It highlights that many critical infrastructure organizations use ERM to manage business risks and emphasizes the importance of evaluating critical systems and assets. The proposed approach can be adopted independently of formal ERM processes and offers a starting point for integrating CIE alongside existing or new ERM practices. Both CIE and ERM are iterative, and their alignment fosters continuous improvement and supports the engineering and operations cultures of an organization.
This report summarizes the activities of this project, which aims at design and testing a scalable, robust, and online framework that provides secure monitoring of photovoltaic generation in the face of potential cyber-attacks.
This presentation is an overview of FEMP Resilient and Secure Infrastructure and Facilities. An educational and interactive workshop centered on resilient and secure federal infrastructure and facilities, with a focus on inverter-based resources at Federal sites, building automation systems, and Federal supply chains. This workshop will illustrate an all-hazards scenario and discuss how Federal agencies can be positioned to resist these real-world scenarios.
This report summarizes the outcomes of Award DE-CR0000023, “Oakland University Cybersecurity Center,” a 31-month project funded by the U.S. Department of Energy Office of Cybersecurity, Energy Security, and Emergency Response (CESER). The project addressed cybersecurity risks facing small and medium-sized manufacturers (SMMs) transitioning to Industry 4.0. The project integrated customer discovery, applied research, and cybersecurity training development. A total of 51 cybersecurity assessments identified significant gaps in baseline practices, incident response, and workforce capability. Research efforts produced a scalable mitigation framework tailored to SMM environments, and workforce analysis identified persistent talent gaps. Eight cybersecurity training modules were developed and deployed via Oakland University’s Professional and Continuing Education (PACE) platform. All objectives were completed, with 98.93% federal budget utilization and cost share exceeding requirements. The project establishes a scalable model for strengthening cybersecurity resilience and workforce capacity across U.S. manufacturing supply chains.
This presentation shows the preliminary results from real-time simulation of steam/CO2 co-electrolysis SOEC models.
SuperLab 2.0 (a five-lab demonstration) is a collaborative, national-scale experiment showcasing the coordination of geographically distributed energy assets in real time. The demonstration integrates 25 physical and digital assets, spanning wind, photovoltaics, batteries, electrolyzers, DC fast chargers, microgrid controllers, building automation systems, small modular reactors, control centers, and gas turbines, across five U.S. Department of Energy (DOE) national laboratories: National Laboratory of the Rockies (NLR), Idaho National Laboratory, National Energy Technology Laboratory, Lawrence Berkeley National Laboratory, and Sandia National Laboratories. These assets are unified using Energy Sciences Network (ESnet), a low-latency, high-performance DOE network, and are controlled via a centralized energy controller hosted at NLR's Advanced Research on Integrated Energy Systems facility. The demonstration validates the ability to stress-test hybrid energy systems under dynamic scenarios to de-risk advanced control strategies for greater resilience and flexibility.
We consider the problem of signal reconstruction for a system under sparse signal corruption by a malicious agent. The reconstruction problem follows the standard error coding problem that has been studied extensively in the literature. We include a new challenge of robust estimation of the attack support. The problem is then cast as a constrained optimization problem merging promising techniques in the area of deep learning and estimation theory. A pruning algorithm is developed to reduce the "false positive" uncertainty of data-driven attack localization results, thereby improving the probability of correct signal reconstruction. Sufficient conditions for the correct reconstruction and the associated reconstruction error bounds are obtained for both exact and inexact attack support estimation. Moreover, a simulation of a water distribution system is presented to validate the proposed techniques.
The resilience of safety-critical systems is gaining importance due to the rise in cyber and physical threats, especially within critical infrastructure. Traditional static resilience metrics may not capture dynamic system states, leading to inaccurate assessments and ineffective responses to cyber threats. This work aims to develop a data-driven, adaptive method for resilience metric learning. We propose a data-driven approach using inverse reinforcement learning (IRL) to learn a single, adaptive resilience metric. The method infers a reward function from expert control actions. Unlike previous approaches using static weights or fuzzy logic, this work applies adversarial inverse reinforcement learning (AIRL), training a generator and discriminator in parallel to learn the reward structure and derive an optimal policy. The proposed approach is evaluated on multiple scenarios: optimal communication network rerouting, power distribution network reconfiguration, and cyber–physical restoration of critical loads using the IEEE 123-bus system. The adaptive, learned resilience metric enables faster critical load restoration in comparison to conventional RL approaches.
Communication networks in power systems are a major part of the smart grid paradigm. It enables and facilitates the automation of power grid operation as well as self-healing in contingencies. Such dependencies on communication networks, though, create a roam for cyber-threats. An adversary can launch an attack on the communication network, which in turn reflects on power grid operation. Attacks could be in the form of false data injection into system measurements, flooding the communication channels with unnecessary data, or intercepting messages. Using machine learning-based processing on data gathered from communication networks and the power grid is a promising solution for detecting cyber threats. In this paper, a co-simulation of cyber-security for cross-layer strategy is presented. The advantage of such a framework is the augmentation of valuable data that enhances the detection as well as identification of anomalies in the operation of the power grid. The framework is implemented on the IEEE 118-bus system. The system is constructed in Mininet to simulate a communication network and obtain data for analysis. A distributed three controller software-defined networking (SDN) framework is proposed that utilizes the Open Network Operating System (ONOS) cluster. According to the findings of our suggested architecture, it outperforms a single SDN controller framework by a factor of more than ten times the throughput. This provides for a higher flow of data throughout the network while decreasing congestion caused by a single controller’s processing restrictions. Furthermore, our CECD-AS approach outperforms state-of-the-art physics and machine learning-based techniques in terms of attack classification. The performance of the framework is investigated under various types of communication attacks.