Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “customize”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

A Custom Radiopaque Thermoresponsive Chemotherapy-Loaded Hydrogel for Intratumoural Injection: An In Vitro and Ex Vivo Assessment of Imaging Characteristics and Material Properties

Purpose: Thermoresponsive hydrogels are gels which have different properties at varying temperatures. The objective of this study was to assess the material characteristics, imaging properties and chemotherapeutic drug release profile of a novel radiopaque thermoresponsive hydrogel in vitro, which is liquid at room temperature but solidifies at body temperature, to determine potential suitability for intratumoural delivery. Materials and Methods: An iodinated radiopaque thermoresponsive hydrogel was formulated using iodixanol at a range of concentrations and assessed for sol–gel transition, radiopacity and imaging using CT and US. A lead formulation containing iodixanol at a concentration of 9.22% weight by weight (w/w, g of iodixanol per g of hydrogel) was evaluated in vitro for injectability, disintegration and dual drug release of cisplatin and paclitaxel from the hydrogel formulation. Results: Radiopacity of the hydrogel increased in a concentration-dependent manner, but the highest concentration of iodixanol evaluated in this study (13.83% w/w) adversely affected the sol–gel transition of the hydrogel; therefore, 9.22% w/w iodixanol hydrogel was identified as the lead formulation. This formulation was readily visible on both CT and US. The formulation was hand injectable through a range of clinically relevant devices, had a sustained disintegration profile for up to 28 days and was able to deliver a sustained release of chemotherapeutic drug for up to 10 days. Conclusions: Favourable in vitro and ex vivo imaging and material characteristics of this thermoresponsive gel are demonstrated, suggesting potential interventional oncology applications for image-guided intratumoural delivery of sustained-release chemotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Demand response event simulator and risk-aware bidding tool for industrial customers

Incentive Based Demand Response (IBDR) program participation delivers financial benefits to the consumers and resiliency benefits to the electricity grid. Effectively participating in these programs as an industrial consumer requires bidding strategies that balance financial risk with operational constraints. Existing bidding tools tend not to fully incorporate stochastic IBDR event modeling, program specific baseline and payment/penalty calculations, or demand reduction process control schemes that account for the cascading impacts of shutdown in complex facilities. Here, this work presents an IBDR event simulator and risk-aware bidding framework tool integrating three key components: a flexible, parameterized demand response event generator that rigorously accounts for program structures and stochasticity, a demand response operational simulation model that generates explicit control strategies for load reduction, and a Monte Carlo simulator to evaluate financial risk for varied capacity bids. A case study at a wastewater treatment plant participating in PG&E's Capacity Bidding Program demonstrates the framework's utility. In the peak capacity price month of August, optimal bidding by the wastewater treatment plant nets a mean IBDR benefit of $101,000 (67% of the August electricity bill) with 0.4% probability of a financial loss. This framework enables industrial operators to make informed bidding decisions, negotiate better program terms with demand response load aggregators, and analyze energy flexibility investments at their facilities. Ultimately, this work reduces participation barriers in IBDR programs and supports the broader goal of enhancing grid reliability and renewable energy integration.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A custom high-stability pulse generator for the test of a novel in-situ magnetic sensor developed to detect radiation damage in undulators

High-performance analog-to-digital converters (ADC) have been widely applied in many areas of science. For instance, magnetic field measurements based on the Faraday’s induction law require high-precision voltmeters to measure induced voltages. In this study in the context of free-electron lasers technology, the Magnetic Measurements Team at SLAC National Accelerator Laboratory proposed a novel in-situ radiation damage detection system (RDDS) for detecting small field variations in undulators. The system measures the flux change in a flexible printed-circuit coil attached to the magnet array during the undulator gap movement. The gap movement changes the magnetic field, which induces a voltage signal in the coil that is measured and integrated with an ADC. Although the system is capable of detecting relative flux changes better than 100 ppm, drift in the ADC’s gain or offset can cause apparent changes in the relative flux. This paper describes the first attempt to developed a high-precision verification circuit to perform ADC testing in the framework of the novel RDDS. The circuit generates a reference voltage pulse with a voltage–time integral relative precision better than 50 ppm for a few hundreds of mVs — the typical order of magnitude measured with the RDDS. The circuit’s design combines a fast and precise switch with a low-noise voltage reference. Long-term measurements allowed statistical analysis and showed that averaging the voltage–time integral of ten pulses gives the required 50 ppm stability. Moreover, reproducibility tests confirmed that the circuit’s output is invariable under small power supply instabilities and equipment shutdown. Instruments and applications designed to quantify the magnetic field by integrating voltage signals may use the pulse generator proposed in this paper for verification purposes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advanced manufacturing of 3D custom boron-carbide collimators designed for complex environments for neutron scattering

Scattered-beam collimation is a very useful method to reduce unwanted backgrounds and to boost the desired sample signal instead. This approach is of particular interest for samples contained within a complex environment that gives rise to much unwanted parasitic scatter. As neutron scattering instrument and techniques advances, small samples are becoming of more and more interest, which necessitates optimized collimation. Here, in this work, we describe a concept for the design and fabrication of advanced scattered-beam collimation 3D printed from B 4 C specifically tailored for samples contained within a complex environment. This concept is demonstrated through the use of a diamond anvil cell for high pressure experimentation, a technique that very typically requires small samples. The collimators here are designed through a modeling procedure via Monte Carlo neutron ray tracing that encompasses the entire system: the instrument, the complex environment and the collimator. Since the first approach of simply scaling up of the print-size was not successful, a novel concept of a multi-part alternate-blade collimator was developed. This approach addresses printing constraints but gives greater flexibility in design. Its performance is computationally compared against an unprintable progressively tighter blade collimator to assess the effect of alternating blades. No strong difference was observed. Its performance was validated through experimentation at the Spallation Neutron Source. The results emphasize the critical importance of ultra-high precision alignment while showing good overall agreement between simulation and experiment and underscore the feasibility of the method and its real-world application.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A methodology for customizing implantation profiles of light ions using a single thin foil energy degrader

We report a method was developed to quantify the spatial distribution and implantation depth of energy-degraded light ions with a thin foil rotating energy degrader for use during multiple ion beam irradiation. The methodology covers three physical phenomena: ions passing through the thin foil, ions travelling through the vacuum to the target, and ion implantation into the target, and accounts for the distribution of ions both in depth and in plane. The processes of energy straggling and scattering were calculated using SRIM. The effects of raster-scanning, and the geometry of the system were implemented in scripts handling the SRIM output files. Elastic backscattering (EBS) using 2.38 MeV H+ protons was used to measure the helium depth profiles after implantation with and without thin foil energy degradation. Defect analysis with transmission electron microscopy confirmed the implantation profiles measured with EBS and calculated with SRIM.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

3D printed polymer gaskets for custom-form batteries

Additive manufacturing (AM) processes, like 3D printing, help to facilitate complex and customizable battery geometries which can provide design freedom and enhance volumetric energy density within electronic devices. AM materials must have the thermal and mechanical properties that enable printability, and when used in batteries, AM materials must also be chemically and electrochemically compatible with the battery chemistry. The compatibility between AM materials and the battery is of particular importance for the cell packaging materials which must be inert and are often overlooked. This study systematically studies AM-compatible polymeric materials for use as gaskets in lithium-ion cells. The materials investigated include three thermoplastics suitable for material extrusion printing: polylactic acid (PLA), polycarbonate, and polypropylene/polyethylene copolymer (PPPEC); and two photoresins suitable for vat photopolymerization (VPP) printing: an acrylate-based photoresin and a polyethylene glycol diacrylate photoresin. The AM gasket materials were tested in comparison to a conventional commercial polypropylene gasket. Mechanical testing (swell measurements and material stiffness) and electrochemical testing (linear sweep voltammetry and galvanostatic cycling of full cells) demonstrated that PLA and the VPP polymers were the least compatible with the lithium-ion battery chemistry, despite their prevalent use in studies of AM batteries, and that PPPEC was the most compatible.

3D printing↗