Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cryogenics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Thermodynamic Vent System for an On-Orbit Cryogenic Reaction Control Engine

A report discusses a cryogenic reaction control system (RCS) that integrates a Joule-Thompson (JT) device (expansion valve) and thermodynamic vent system (TVS) with a cryogenic distribution system to allow fine control of the propellant quality (subcooled liquid) during operation of the device. It enables zero-venting when coupled with an RCS engine. The proper attachment locations and sizing of the orifice are required with the propellant distribution line to facilitate line conditioning. During operations, system instrumentation was strategically installed along the distribution/TVS line assembly, and temperature control bands were identified. A sub-scale run tank, full-scale distribution line, open-loop TVS, and a combination of procured and custom-fabricated cryogenic components were used in the cryogenic RCS build-up. Simulated on-orbit activation and thruster firing profiles were performed to quantify system heat gain and evaluate the TVS s capability to maintain the required propellant conditions at the inlet to the engine valves. Test data determined that a small control valve, such as a piezoelectric, is optimal to provide continuously the required thermal control. The data obtained from testing has also assisted with the development of fluid and thermal models of an RCS to refine integrated cryogenic propulsion system designs. This system allows a liquid oxygenbased main propulsion and reaction control system for a spacecraft, which improves performance, safety, and cost over conventional hypergolic systems due to higher performance, use of nontoxic propellants, potential for integration with life support and power subsystems, and compatibility with in-situ produced propellants.

Hurlbert, Eric A.↗

Cryogenic Applications of Commercial Electronic Components

We have developed a range of techniques useful for constructing analog and digital circuits for operation in a liquid Helium environment (4.2K), using commercially available low power components. The challenges encountered in designing cryogenic electronics include finding components that can function usefully in the cold and possess low enough power dissipation so as not to heat the systems they are designed to measure. From design, test, and integration perspectives it is useful for components to operate similarly at room and cryogenic temperatures; however this is not a necessity. Some of the circuits presented here have been used successfully in the MUSTANG and in the GISMO camera to build a complete digital to analog multiplexer (which will be referred to as the Cryogenic Address Driver board). Many of the circuit elements described are of a more general nature rather than specific to the Cryogenic Address Driver board, and were studied as a part of a more comprehensive approach to addressing a larger set of cryogenic electronic needs.

Buchanan, Ernest D.↗

Cryogenic Moisture Uptake in Foam Insulation for Space Launch Vehicles

Rigid polyurethane foams and rigid polyisocyanurate foams (spray-on foam insulation), like those flown on Shuttle, Delta IV, and will be flown on Ares-I and Ares-V, can gain an extraordinary amount of water when under cryogenic conditions for several hours. These foams, when exposed for eight hours to launch pad environments on one side and cryogenic temperature on the other, increase their weight from 35 to 80 percent depending on the duration of weathering or aging. This effect translates into several thousand pounds of additional weight for space vehicles at lift-off. A new cryogenic moisture uptake apparatus was designed to determine the amount of water/ice taken into the specimen under actual-use propellant loading conditions. This experimental study included the measurement of the amount of moisture uptake within different foam materials. Results of testing using both aged specimens and weathered specimens are presented. To better understand cryogenic foam insulation performance, cryogenic moisture testing is shown to be essential. The implications for future launch vehicle thermal protection system design and flight performance are discussed.

Fesmire, James E.↗

Aerogel Blanket Insulation Materials for Cryogenic Applications

Aerogel blanket materials for use in thermal insulation systems are now commercially available and implemented by industry. Prototype aerogel blanket materials were presented at the Cryogenic Engineering Conference in 1997 and by 2004 had progressed to full commercial production by Aspen Aerogels. Today, this new technology material is providing superior energy efficiencies and enabling new design approaches for more cost effective cryogenic systems. Aerogel processing technology and methods are continuing to improve, offering a tailor-able array of product formulations for many different thermal and environmental requirements. Many different varieties and combinations of aerogel blankets have been characterized using insulation test cryostats at the Cryogenics Test Laboratory of NASA Kennedy Space Center. Detailed thermal conductivity data for a select group of materials are presented for engineering use. Heat transfer evaluations for the entire vacuum pressure range, including ambient conditions, are given. Examples of current cryogenic applications of aerogel blanket insulation are also given. KEYWORDS: Cryogenic tanks, thermal insulation, composite materials, aerogel, thermal conductivity, liquid nitrogen boil-off

Coffman, B. E.↗

Internship at NASA Kennedy Space Center's Cryogenic Test laboratory

NASA's Kennedy Space Center (KSC) is known for hosting all of the United States manned rocket launches as well as many unmanned launches at low inclinations. Even though the Space Shuttle recently retired, they are continuing to support unmanned launches and modifying manned launch facilities. Before a rocket can be launched, it has to go through months of preparation, called processing. Pieces of a rocket and its payload may come in from anywhere in the nation or even the world. The facilities all around the center help integrate the rocket and prepare it for launch. As NASA prepares for the Space Launch System, a rocket designed to take astronauts beyond Low Earth Orbit throughout the solar system, technology development is crucial for enhancing launch capabilities at the KSC. The Cryogenics Test Laboratory at Kennedy Space Center greatly contributes to cryogenic research and technology development. The engineers and technicians that work there come up with new ways to efficiently store and transfer liquid cryogens. NASA has a great need for this research and technology development as it deals with cryogenic liquid hydrogen and liquid oxygen for rocket fuel, as well as long term space flight applications. Additionally, in this new era of space exploration, the Cryogenics Test Laboratory works with the commercial sector. One technology development project is the Liquid Hydrogen (LH2) Ground Operations Demonstration Unit (GODU). LH2 GODU intends to demonstrate increased efficiency in storing and transferring liquid hydrogen during processing, loading, launch and spaceflight of a spacecraft. During the Shuttle Program, only 55% of hydrogen purchased was used by the Space Shuttle Main Engines. GODU's goal is to demonstrate that this percentage can be increased to 75%. Figure 2 shows the GODU layout when I concluded my internship. The site will include a 33,000 gallon hydrogen tank (shown in cyan) with a heat exchanger inside the hydrogen tank attached to a refrigerator capable of removing 850 Watts at 20 Kelvin (shown in green). The refrigerator and most of its supporting equipment will be kept in a standard shipping container (shown in pink). Currently, GODU is in the fabrication process and some of the large components have already been purchased.

Holland, Katherine↗

Vent System Analysis for the Cryogenic Propellant Storage Transfer Ground Test Article

To test and validate key capabilities and technologies required for future exploration elements such as large cryogenic propulsion stages and propellant depots, NASA is leading the efforts to develop and design the Cryogenic Propellant Storage and Transfer (CPST) Cryogenic Fluid Management (CFM) payload. The primary objectives of CPST payload are to demonstrate: 1) in-space storage of cryogenic propellants for long duration applications; and 2) in-space transfer of cryogenic propellants. The Ground Test Article (GTA) is a technology development version of the CPST payload. The GTA consists of flight-sized and flight-like storage and transfer tanks, liquid acquisition devices, transfer, and pressurization systems with all of the CPST functionality. The GTA is designed to perform integrated passive and active thermal storage and transfer performance testing with liquid hydrogen (LH2) in a vacuum environment. The GTA storage tank is designed to store liquid hydrogen and the transfer tank is designed to be 5% of the storage tank volume. The LH2 transfer subsystem is designed to transfer propellant from one tank to the other utilizing pressure or a pump. The LH2 vent subsystem is designed to prevent over-pressurization of the storage and transfer tanks. An in-house general-purpose computer program was utilized to model and simulate the vent subsystem operation. The modeling, analysis, and the results will be presented in the final paper.

Hedayat, A↗

Cryogenics Research and Engineering Experience

Energy efficient storage, transfer and use of cryogens and cryogenic propellants on Earth and in space have a direct impact on NASA, government and commercial programs. Research and development on thermal insulation, propellant servicing, cryogenic components, material properties and sensing technologies provides industry, government and research institutions with the cross-cutting technologies to manage low-temperature applications. Under the direction of the Cryogenic Testing Lab at Kennedy Space Center, the work experience acquired allowed me to perform research, testing, design and analysis of current and future cryogenic technologies to be applied in several projects.

Toro Medina, Jaime A.↗

Cryogenic Propellant Storage and Transfer Technology Demonstration: Advancing Technologies for Future Mission Architectures Beyond Low Earth Orbit

As part of U.S. National Space Policy, NASA is seeking an innovative path for human space exploration, which strengthens the capability to extend human and robotic presence throughout the solar system. NASA is laying the groundwork to enable humans to safely reach multiple potential destinations, including the Moon, asteroids, Lagrange points, and Mars and its environs. In support of this, NASA is embarking on the Technology Demonstration Mission Cryogenic Propellant Storage and Transfer (TDM CPST) Project to test and validate key cryogenic capabilities and technologies required for future exploration elements, opening up the architecture for large cryogenic propulsion stages and propellant depots. The TDM CPST will provide an on-orbit demonstration of the capability to store, transfer, and measure cryogenic propellants for a duration that enables long term human space exploration missions beyond low Earth orbit. This paper will present a summary of the cryogenic fluid management technology maturation effort, infusion of those technologies into flight hardware development, and a summary of the CPST preliminary design.

Chojnacki, Kent T.↗

TankSIM: A Cryogenic Tank Performance Prediction Program

Accurate prediction of the thermodynamic state of the cryogenic propellants in launch vehicle tanks is necessary for mission planning and successful execution. Cryogenic propellant storage and transfer in space environments requires that tank pressure be controlled. The pressure rise rate is determined by the complex interaction of external heat leak, fluid temperature stratification, and interfacial heat and mass transfer. If the required storage duration of a space mission is longer than the period in which the tank pressure reaches its allowable maximum, an appropriate pressure control method must be applied. Therefore, predictions of the pressurization rate and performance of pressure control techniques in cryogenic tanks are required for development of cryogenic fluid long-duration storage technology and planning of future space exploration missions. This paper describes an analytical tool, Tank System Integrated Model (TankSIM), which can be used for modeling pressure control and predicting the behavior of cryogenic propellant for long-term storage for future space missions. It is written in the FORTRAN 90 language and can be compiled with any Visual FORTRAN compiler. A thermodynamic vent system (TVS) is used to achieve tank pressure control. Utilizing TankSIM, the following processes can be modeled: tank self-pressurization, boiloff, ullage venting, and mixing. Details of the TankSIM program and comparisons of its predictions with test data for liquid hydrogen and liquid methane will be presented in the final paper.

Bolshinskiy, L. G.↗

Vented Chill / No-Vent Fill of Cryogenic Propellant Tanks

Architectures for extended duration missions often include an on-orbit replenishment of the space vehicle's cryogenic liquid propellants. Such a replenishment could be accomplished via a tank-to-tank transfer from a dedicated tanker or a more permanent propellant depot storage tank. Minimizing the propellant loss associated with transfer line and receiver propellant tank thermal conditioning is essential for mass savings. A new methodology for conducting tank-to-tank transfer while minimizing such losses has been demonstrated. Charge-Hold-Vent is the traditional methodology for conducting a tank-to-tank propellant transfer. A small amount of cryogenic liquid is introduced to chill the transfer line and propellant tank. As the propellant absorbs heat and undergoes a phase change, the tank internal pressure increases. The tank is then vented to relieve pressure prior to another charge of cryogenic liquid being introduced. This cycle is repeated until the transfer lines and tank are sufficiently chilled and the replenishment of the propellant tank is complete. This method suffers inefficiencies due to multiple chill and vent cycles within the transfer lines and associated feed system components. Additionally, this system requires precise measuring of cryogenic fluid delivery for each transfer, multiple valve cycling events, and other complexities associated with cycled operations. To minimize propellant loss and greatly simplify on-orbit operations, an alternate methodology has been designed and demonstrated. The Vented Chill / No Vent Fill method is a simpler, constant flow approach in which the propellant tank and transfer lines are only chilled once. The receiver tank is continuously vented as cryogenic liquid chills the transfer lines, tank mass and ullage space. Once chilled sufficiently, the receiver tank valve is closed and the tank is completely filled. Interestingly, the vent valve can be closed prior to receiver tank components reaching liquid saturation temperature. An incomplete fill results if insufficient energy is removed from the tank's thermal mass and ullage space. The key to successfully conducting the no vent fill is to assure that sufficient energy is removed from the system prior to closing the receiver tank vent valve. This paper will provide a description of the transfer methodology and test article, and will provide a discussion of test results.

Rhys, Noah O.↗

Inferential Framework for Autonomous Cryogenic Loading Operations

We address problem of autonomous cryogenic management of loading operations on the ground and in space. As a step towards solution of this problem we develop a probabilistic framework for inferring correlations parameters of two-fluid cryogenic flow. The simulation of two-phase cryogenic flow is performed using nearly-implicit scheme. A concise set of cryogenic correlations is introduced. The proposed approach is applied to an analysis of the cryogenic flow in experimental Propellant Loading System built at NASA KSC. An efficient simultaneous optimization of a large number of model parameters is demonstrated and a good agreement with the experimental data is obtained.

Luchinsky, Dmitry G.↗

Cryogenic Parametric Characterization of Gallium Nitride Switches

This report presents the parametric characterization results of four GaN field-effect transistor (FET) devices from three manufacturers, one of which is a cascode device, and compares those results to a Si power metal-oxide-semiconductor fieldeffect transistor (MOSFET) and a SiC power MOSFET. The devices were first characterized at ambient temperature, then at cryogenic temperatures down to -196 C (LN2 temperature), and finally at ambient temperature again in the event that the device parameters were permanently affected by the cryogenic temperatures. In general, the results indicate that the GaN devices show significant improvement overall at cryogenic temperatures in the parameters characterized, such as onresistance and leakage currents, compared to the Si and SiC devices. The results show that the SiC device tested should not be used at cryogenic temperatures due to the significant increase in on-resistance. The results also show that the GaN and Si parameters characterized were either not affected by the cryogenic temperatures or changed by no more than +/-20 percent post LN2 submersion. The device that exhibited the most parametric change post LN2 submersion was the SiC power MOSFET in its leakage currents.

Gonzalez, Marcelo C.↗

Cryogenic Heat Transfer System

Disclosed herein is a cryogenic heat transfer system capable of transferring 50 W or more at cryogenic temperatures of 100.degree. K or less for use with cryocooler systems. In an embodiment, a cryogenic heat transfer system comprises a refrigerant contained within an inner chamber bound by a condenser in fluid communication with an evaporator through at least one flexible conduit, the condenser in thermal communication with the cold station of a cryocooler, and the evaporator positionable in thermal communication with a heat source, typically a radiation shield of a cryogenic chamber. A process to remove heat from a cryogenic chamber is also disclosed.

Chui, Talso C.↗

Comparative Analysis of Two Cryogenic Force Balance Calibration Systems

Cryogenic wind-tunnel facilities face unique challenges in the calibration and operation of various measurement systems and instrumentation. Instruments that are subjected to the cryogenic conditions of the test plenum require careful design and calibration procedures to maintain instrument performance. NASA’s National Transonic Facility (NTF) and the European Transonic Windtunnel (ETW) are two cryogenic wind-tunnel facilities, each with the ability to calibrate force measurement systems (FMS) at cryogenic conditions. These facilities have different methodologies and processes for calibrating these systems. This paper discusses differences in the methodologies and processes and compares the results of two separate cryogenic calibrations of the NTF-118A force balance that were completed at both wind-tunnel facilities.

Toro, Kenneth G.↗

NASA Team Investigates an Enhanced Approach for Conducting Tank-to-Tank Transfers of Cryogens for Micro-Gravity Applications

NASA is putting emphases on reusable cryogenic systems to enable returning astronauts to the lunar surface, and eventually on to Mars. Such systems will require replenishing cryogens on-orbit via a cryogenic tanker or propellant depot, and potentially on the lunar and Martian surfaces with the utilization of in-situ resources. Replenishing cryogens on-orbit requires a tank-to-tank transfer which presents challenges due to thermal environments and the absence of gravity. If the transfer process is initiated with the receiving tank empty and at atmospheric temperature, it then must be chilled to cryogenic temperature to enable filling. Likewise, the transfer lines and associated hardware must be prechilled to assure liquid is transferred. Since prechilling results in propellant loss, it is preferred to minimize this process in interest of saving propellant mass. To simplify the operations associated with propellant transfer and explore potential mass savings, NASA has been experimenting with a new methodology which uses a Vented Chill/No-Vent Fill (VC/NVF) approach, and enhances the process using a 3-D printed spray injector augmented with a Thermodynamic Vent System (TVS).

Jonathan R Stephens↗

Solid-State Thermodynamic Vent System for Control of Cryogenic Propellants

A Solid-State Thermodynamic Vent System (STVS) is a novel Cryogenic Fluid Management (CFM) technology for spacecraft cryogenic propellant tanks that may reduce boiloff while providing greater control over the propellent condition. By exploiting the vacuum-induced cryocooling potential of cryogen-saturated silica aerogel material, an internal STVS heat exchanger expels some sacrificial cryogenic propellant to the vacuum of space to produce cooling within the storage tank. This cooling is transferred directly to the stored fluid, thereby reducing boiloff and increasing hold times. The primary STVS project objective was to design and build a bespoke STVS heat exchanger that employed aerogel blanket material and perform a ground demonstration of the technology using liquid nitrogen (LN2) as the cryogenic propellant. This demonstration aimed to prove that an STVS can have a positive influence on the tank boiloff, shown through a reduction in mass flow rate out of the system during operation, and exercise control over the tank pressure. Testing proved the effectiveness of the concept by reducing the LN2 boiloff rate and tank pressure by roughly 70% and 77% respectively during a single pump-down cycle, which sacrificed around 1.8 kg of propellant.

Propellant Production↗

Cryogenics and Fluids at NASA-Goddard Space Flight Center

Abstract: Spacecraft thermal design presents unique thermal and fluid challenges caused by a variety of harsh spacecraft thermal environments. In addition, at cryogenic temperatures (i.e., less than 123 K (-150° C), and sometimes as low as 50 milliKelvin), more challenges arise, such as the increasing importance of mitigating thermal radiation, the effects of coefficient of thermal expansion mismatches between different materials, changes in the physics behavior of materials, and increasing thermodynamic difficulty of lifting heat up large temperature gradients. In this talk, Dr. Rueger will present a broad overview of spacecraft thermal environments; cryogenic design practices; components of interest for the Cryogenics and Fluids Branch (e.g., cryocoolers, adiabatic demagnetization refrigerators, heat switches, and superconducting leads); cryogenic considerations in some current NASA mission examples (e.g., the DragonFly mission to Titan and the X-ray Imaging and Spectroscopy Mission); and capabilities of the Cryogenics and Fluids Branch at NASA.

Paul Rueger↗

Magnetically Latching Cryogenic Fluid Coupler for Lunar Surface Operations

Envisioning future lunar exploration and habitation necessitates addressing numerous needs related to sustaining human life and managing resources on the lunar surface. One of these needs is proficient cryogenic fluid management, which is particularly challenging in the dusty lunar environment. To address the need for a robust and environmentally tolerant cryogenic management solution, the CryoMag Coupler was developed as demonstrative solution. The CryoMag is a low-force cryogenic coupler that facilitates the mating, latching, and de-mating of cryogenic connections by way of a magnetic interface, providing a dust-tolerant solution to manage cryogenic fluids in the challenging lunar environment. This paper details the design and testing of this Coupler.

Nic Heersema↗