Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cooling system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Shuttle cryogenic supply system optimization study. Volume 4: Cryogenic cooling in environmental control systems

An analysis of cryogenic fluid cooling in the environmental control system of the space shuttle was conducted. The technique for treating the cryogenic fluid storage and supply tanks and subsystems as integrated systems was developed. It was concluded that a basic incompatibility exists between the heat generated and the cryogen usage rate and cryogens cannot be used to absorb the generated heat. The use of radiators and accumulators to provide additional cooling capability is recommended.

Source record↗

Space station freedom resource nodes internal thermal control system

This paper presents an overview of the design and operation of the internal thermal control system (ITCS) developed for Space Station Freedom by the NASA-Johnson Space Center and McDonnell Douglas Aerospace to provide cooling for the resource nodes, airlock, and pressurized logistics modules. The ITCS collects, transports and rejects waste heat from these modules by a dual-loop, single-phase water cooling system. ITCS performance, cooling, and flow rate requirements are presented. An ITCS fluid schematic is shown and an overview of the current baseline system design and its operation is presented. Assembly sequence of the ITCS is explained as its configuration develops from Man Tended Capability (MTC), for which node 2 alone is cooled, to Permanently Manned Capability (PMC) where the airlock, a pressurized logistics module, and node 1 are cooled, in addition to node 2. A SINDA/FLUINT math model of the ITCS is described, and results of analyses for an MTC and a PMC case are shown and discussed.

Merhoff, Paul↗

EVA space suit Evaporative Cooling/Heating Glove System (ECHGS)

A new astronaut glove, the Evaporative Cooling/Heating Glove System (ECHGS), was designed and developed to allow the handling of objects between -200 F and +200 F. Active heating elements, positioned at each finger pad, provide additional heat to the finger pads from the rest of the finger. A water evaporative cooling system provides cooling by the injection of water to the finger areas and the subsequent direct evaporation to space. Thin, flexible insulation has been developed for the finger areas to limit thermal conductivity. Component and full glove tests have shown that the glove meets and exceeds the requirements to hold a 11/2 inch diameter bar at + or - 200 F for three minutes within comfort limits. The ECHGS is flexible, lightweight and comfortable. Tactility is reasonable and small objects can be identified especially by the fingertips beyond the one half width active elements.

Coss, F. A.↗

Solar System Controller

In designing a control for Bethany College's solar heating and cooling system, Apollo Energy Control, Inc. used Marshall Space Flight Center's doe solar and heating and cooling technology. The technology helped the company design a highly reliable, simply operated system with substantial savings in engineering time.

Source record↗

Advanced spacecraft fuel cell systems

The development and characteristics of advanced spacecraft fuel cell systems are discussed. The system is designed to operate on low pressure, propulsion grade hydrogen and oxygen. The specific goals are 10,000 hours of operation with refurbishment, 20 pounds per kilowatt at a sustained power of 7 KW, and 21 KW peaking capability for durations of two hours. The system rejects waste heat to the spacecraft cooling system at power levels up to 7 KW. At higher powers, the system automatically transfers to open cycle operation with overboard steam venting.

Thaller, L. H.↗

Residential solar-heating/cooling system

Report documents progress of residential solar-heating and cooling system development program at 5-month mark of anticipated 17-month program. System design has been completed, and development and component testing has been initiated. Report includes diagrams, operation overview, optimization studies of subcomponents, and marketing plans for system.

Source record↗

Compact Liquid Deaerator

Gases are removed from liquids by a new deaerator that takes up only 5 inches (12.7 cm) at top of a medium-sized storage tank. Deaerator has a multiple cascading header that exposes more fluid at lower pressures than typical commercial deaerators. Potential applications are in hydraulic systems for aircraft and heavy machinery, in cooling systems where deaerated liquid is needed to prevent cavitation of pump.

Yamauchi, S. T.↗

Modular Cooling Components

Three modular heat-transfer components designed for use together or separately. Simple mechanical connections facilitate assembly of these and related heat-transfer components into cooling systems of various configurations, such as to cool laboratory equipment rearranged for different experiments. Components are clamp-on cold plate, cold plate attached to flexible heat pipe, and thermal-bus receptacle. Clamp-on cold plate moved to any convenient location for attachment of equipment cooled by it, then clamped onto thermal bus. Heat from equipment conducted through plate and into coolant. Thermal-bus receptacle integral with thermal bus. Includes part of thermal bus to which clamp-on cold plate attached, plus tapered socket into which condenser end of flexible heat pipe plugged. Thermal-bus receptacle includes heat-pipe wick structure using coolant in bus to enhance transfer of heat from cold plate.

Eastman, G. Yale↗

In-Orbit Selection of Cryocooler Drive Frequencies for XRISM/Resolve

The XRISM/Resolve instrument cooling system uses adiabatic demagnetization refrigerators (ADRs) to cool the detectors to 50 mK and two types of cryocoolers to reduce heat load on the He tank, Joule-Thomson and Stirling cryocoolers. Resolve was designed with tunable cryocooler frequencies so that any mechanical interference and its effect on performance could be minimized. Measurements at different cryocooler drive frequencies were used to quantify the interference and narrow the acceptable range of frequency options. For Resolve the choice of cryocooler drive frequencies dramatically influences the instrument performance. Poor choices have been shown to degrade ADR cooling power and degrade the spectroscopic performance of the instrument. However, good choices have been shown to be free of undesirable features, allowing the instrument to satisfy its performance requirements with significant margin. Thus, the choice of drive frequencies is a critical factor for overall instrument performance. The drive frequencies of the Joule-Thomson cooler operating near 52 Hz, and the Stirling coolers operating near 15 Hz were adjusted in three distinct scan sequences to efficiently narrow the candidate frequency options. The frequency choices were based on stability of the 50 mK control thermometer, changes in the ADR demagnetization rate, and changes in detector noise. Scans across the drive frequency range of each cryocooler were performed multiple times during ground testing. Surprisingly, the results were not repeatable across test campaigns and did not conform to any discernable trend, but they were repeatable when remeasured within a single cool-down cycle. The conclusion was that the good/bad drive frequencies changed during Dewar warmup/cooldown, and possibly after mechanical vibration tests. Therefore, the settings could not be finalized before launch, and scans during instrument commissioning were necessary. This paper describes the cryocooler frequency scan measurements and compares the results during instrument commissioning to those performed during ground tests.

Gary A. Sneiderman↗

In-Orbit Selection of Cryocooler Drive Frequencies for XRISM/Resolve

The XRISM/Resolve instrument cooling system uses adiabatic demagnetization refrigerators (ADRs) to cool the detectors to 50 mK and Joule-Thomson and Stirling cryocoolers to reduce heat load on the He tank supporting the ADRs. Resolve was designed with tunable cryocooler drive frequencies so that interference could be avoided. The cryocooler generated micro-vibration changes with drive frequency and that micro-vibration causes interference and degrades instrument performance. Poor drive frequency choices have been shown to dramatically impact ADR cooling power, temperature stability, detector noise, and degrading spectroscopic performance. However, some choices are free of these features, allowing the instrument to satisfy its performance requirements with significant margin. Thus, the choice of drive frequencies is critical to achieving peak instrument performance. The drive frequencies of the Joule-Thomson cooler, near 52 Hz, and the Stirling coolers, near 15 Hz, were adjusted in three scan sequences while measuring interference to narrow candidate frequency options. Choices were based on stability of the 50 mK control thermometer, changes in the ADR demagnetization rate, and changes in detector noise. These scans were performed routinely during ground testing. Surprisingly though, the results were not repeatable after the Dewar was warmed and re-cooled but were repeatable when remeasured during the same test campaign. Since the good/bad drive frequencies change during Dewar warmup/cooldown, and possibly after vibration events, the drive frequencies could not be finalized before launch. This paper describes the cryocooler frequency scan measurements and compares the results during instrument commissioning to those performed during ground tests.

XRISM↗

In-Orbit Selection of Cryocooler Drive Frequencies for XRISM/Resolve

The XRISM/Resolve instrument cooling system uses adiabatic demagnetization refrigerators (ADRs) to cool the detectors to 50 mK and two types of cryocoolers to reduce heat load on the He tank, Joule-Thomson and Stirling cryocoolers. Resolve was designed with tunable cryocooler frequencies so that any mechanical interference and its effect on performance could be minimized. Measurements at different cryocooler drive frequencies were used to quantify the interference and narrow the acceptable range of frequency options. For Resolve the choice of cryocooler drive frequencies dramatically influences the instrument performance. Poor choices have been shown to degrade ADR cooling power and degrade the spectroscopic performance of the instrument. However, good choices have been shown to be free of undesirable features, allowing the instrument to satisfy its performance requirements with significant margin. Thus, the choice of drive frequencies is a critical factor for overall instrument performance. The drive frequencies of the Joule-Thomson cooler operating near 52 Hz, and the Stirling coolers operating near 15 Hz were adjusted in three distinct scan sequences to efficiently narrow the candidate frequency options. The frequency choices were based on stability of the 50 mK control thermometer, changes in the ADR demagnetization rate, and changes in detector noise. Scans across the drive frequency range of each cryocooler were performed multiple times during ground testing. Surprisingly, the results were not repeatable across test campaigns and did not conform to any discernable trend, but they were repeatable when remeasured within a single cool-down cycle. The conclusion was that the good/bad drive frequencies changed during Dewar warmup/cooldown, and possibly after mechanical vibration tests. Therefore, the settings could not be finalized before launch, and scans during instrument commissioning were necessary. This paper describes the cryocooler frequency scan measurements and compares the results during instrument commissioning to those performed during ground tests.

XRISM↗

Cryogenic probe station for use in automated microwave and noise figure measurements

A cryogenic measurement system capable of performing on-wafer RF testing of semiconductor devices and circuits has been developed. This 'CryoProbe Station' can wafer-probe devices and circuits at cryogenic temperatures, thus eliminating the need for wire bonds. The system operates under vacuum created by a sorption pump. It uses an open cycle cooling system that can be cooled with either liquid nitrogen or liquid helium. Presently, it can reach temperatures, as low as 80 K and 37 K for each of the coolants, respectively. The temperature can be raised using a heater and it is stabilized to within 0.2 K by use of a temperature controller. The CryoProbe Station features a 1 by 2 inch stage that can hold large circuits and calibration standards simultaneously. The system is used with a Hewlett Packard 8510C Automatic Network Analyzer (ANA) to obtain S-parameter data over the frequency range 0.045-26.5 GHz. S-parameter data on HEMT (high electron mobility transistors) devices has been obtained with this station. With the use of DEEMBED software from NIST, detailed transmission line studies have been performed. Although the CryoProbe Station is designed for frequencies up to 26.5 GHz, useful transmission line data has been obtained for frequencies as high as 40 GHz. The CryoProbe station has also been used with the ATN noise figure measurement system to perform automatic, temperature dependent noise figure measurements.

Taub, Susan R.↗

Solar heating and cooling demonstration project at the Florida solar energy center

The retrofitted solar heating and cooling system installed at the Florida Solar Energy Center is described. The system was designed to supply approximately 70 percent of the annual cooling and 100 percent of the heating load. The project provides unique high temperature, nonimaging, nontracking, evacuated tube collectors. The design of the system was kept simple and employs five hydronic loops. They are energy collection, chilled water production, space cooling, space heating and energy rejection. Information is provided on the system's acceptance test results operation, controls, hardware and installation, including detailed drawings.

Source record↗

Weight trends for a fully reusable advanced single-stage shuttle

The rate at which subsystem weights grow with vehicle gross weight is assessed and is shown to be critical to the efficiency of large Earth to orbit transports. The overall trend, however, is a reduction in the inerts as a percentage of gross weight as the vehicle size is increased. For this reason, the larger the vehicle, the greater the payload weight delivered per pound of vehicle manufactured. Other critical issues addressed include the effects of wing loading and wing size on wing weight, the effect of entry planform loading on thermal protection system weight, the impact of power demand on cooling system and prime power weight, and tank fineness ratio on insulation weight. The effects of body shape and various internal packaging arrangements on weight and balance are also discussed. The greatest impact on overall vehicle weight is body shape and internal packaging, and could account for weight savings of up to 30 percent in body structure. Other subsystems are important, but the savings are much smaller in relation to overall vehicle weight--individually less than one percent.

Macconochie, I. O.↗

Weight trends for a fully reusable advanced single-stage Shuttle

The rate at which subsystem weights grow with vehicle gross weight is assessed and is shown to be critical to the efficiency of large earth-to-orbit transports. Some subsystems grow as the square of vehicle size, others grow as the cube of vehicle size, and still others remain nearly constant irrespective of vehicle size. The overall trend, however, is a reduction in the inerts as a percentage of gross as the vehicle size is increased. For this reason, the larger the vehicle, the greater the payload weight delivered per pound of vehicle manufactured. Other critical issues addressed include the effects of wing loading and wing size on wing weight, the effect of entry planform loading on thermal protection system weight, the impact of power demand on cooling system and prime power weight, and tank fineness ratio on insulation weight. The effects of body shape and various internal packaging arrangements on weight and balance are also discussed. Of greatest impact on overall vehicle weight is body shape and internal packaging and could account for weight savings of up to 30 percent in body structure. Other subsystems are important but the savings are much smaller in relation to overall vehicle weight - individually less than one percent.

Macconochie, I. O.↗

A comparison of superconductor and manganin technology for electronic links used in space mission applications

The electronic link connecting cryogenically cooled radiation detectors to data acquisition and signal processing electronics at higher temperatures contributes significantly to the total heat load on spacecraft cooling systems that use combined mechanical and cryogenic liquid cooling. Using high transition temperature superconductors for this link has been proposed to increase the lifetime of space missions. Herein, several YBCO (YBa2Cu3O7) superconductor-substrate combinations were examined and total heat loads were compared to manganin wire technology in current use. Using numerical solutions to the heat-flow equations, it is shown that replacing manganin technology with YBCO thick film technology can extend a 7-year mission by up to 1 year.

Caton, R.↗