At least 307 records · Page 17

The role of gas flow distributions on CO 2 mineralization within monolithic cemented composites: coupled CFD-factorial design approach

The carbonation kinetics of monolithic cementing composites are strongly affected by gas transport which is, in turn, influenced by microstructural resistances and the presence of liquid water within pore networks. The non-uniform gas flow distribution within the CO 2 mineralization reactor can impart mass transfer resistance in the monolith microstructure, which affects the uptake of CO 2 (“carbonation”) of the cementing composites. This paper demonstrates how the gas spatial distribution (velocity and flow rate; quantified by CFD analysis) and processing conditions (temperature, relative humidity, and flow rate; quantified by factorial design) affect drying and carbonation, and in turn, the engineering properties of a representative ‘monolithic’ carbonate-cemented concrete component (i.e., herein concrete masonry unit: CMUs, also known as concrete block). It is shown that the gas flow distribution affects drying front penetration and results in moisture and carbonation gradients within the monolith. Particularly, variations in drying kinetics caused by non-uniformity of the contacting gas velocity impose gradients in moisture saturation, which results in increasing microstructural resistance to CO 2 transport. The resultant non-uniform carbonate-mineral formation (i.e., carbonate cementation), if not controlled, can produce gradients in mechanical properties and may alter failure patterns upon loading. Finally, these insights inform the optimal design of gas flow distribution systems and processing conditions within CO 2 mineralization reactors for the manufacturing of low-CO 2 concrete components using CO 2 -dilute industrial flue gas streams.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Speciation mapping of the oxidation layer on aged uranium dioxide using scanning transmission x-ray spectromicroscopy

In this study, UO 2 was aged in humid air and prepared as a thin section using a focused ion beam (FIB) instrument. The specimen was measured using synchrotron radiation spectromicroscopy techniques at the Beamline 11.0.2 STXM end station of the Advanced Light Source (ALS). Non-negative matrix factorization (NMF) methods were used to identify and map three component x-ray absorption near-edge structure (XANES) spectra in the oxygen K-edge data, revealing a surface layer of U 4 O 9 with a thickness of 206 ± 21 nm, and the bulk of the sample remaining as UO 2 . Uranium N 4,5 -edge XANES spectromicroscopy supports these results. The diffusion-controlled parabolic rate constant for UO 2 oxidation to U 4 O 9 was calculated from the observed layer thickness and compared to literature values. Complementary transmission electron microscopy (TEM) was used to image the sample and identify the phases present in various regions, confirming the STXM results.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Strip sensor performance in prototype modules built for ATLAS ITk

ATLAS experiment is preparing an upgrade of its detector for High-Luminosity LHC (HL-LHC) operation. The upgrade involves installation of the new all-silicon Inner Tracker (ITk). In the context of the ITk preparations, more than 80 strip modules were built with prototype barrel sensors. They were tested with electrical readout on a per-channel basis. In general, an excellent performance was observed, consistent with previous ASIC-level and sensor-level tests. However, the lessons learned included two phenomena important for the future phases of the project. First was the need to store and test the modules in a dry environment due to humidity sensitivity of the sensors. The second was an observation of high noise regions for 2 modules. The high noise regions were tested further in several ways, including monitoring the performance as a function of time and bias voltage. Additionally, direct sensor-level tests were performed on the affected channels. The inter-strip resistance and bias resistance tests showed low values, indicating a temporary loss of the inter-strip isolation. A subsequent recovery of the noise performance was observed. Here we present the test details, an analysis of how the inter-strip isolation affects the module noise, and the relationship with sensor-level quality control tests.

47 OTHER INSTRUMENTATION↗

Hamilton: Flexible, Open Source $10 Wireless Sensor System for Energy Efficient Building Operation

Sensors for improving building performance are rapidly populating the market, driven in part by the drive to reduce greenhouse gas emissions resulting from energy production as well as improve the interior environment for healthy and more productive spaces. UC Berkeley has led wireless sensor development over the past 25 years (e.g., Telos mote), with the Hamilton (named after Alexander Hamilton on the US $10 bill) as the most recent. The Hamilton sensor was designed as a low-cost high-performance sensor that is modular and interoperable. The objective of the Hamilton project was to create, evaluate and establish the technological foundations for secure and easy to deploy building energy efficiency applications utilizing pervasive, low-cost wireless sensors integrated with traditional Building Management Systems (BMS), consumer-sector building components, and powerful data analytics. The project included iterative hardware design, incorporating a high-performance database (BTrDb, http://btrdb.io/), creating and iterating the development of secure data middleware (BOSSwave, WAVE/WAVEMQ), working with and pushing the development of an open-source tiny operating system RiotOS, and implementing and improving protocols such as Thread/OpenThread and TCP/IP. The hardware benefited from careful design to drive down the cost; the design included a System-on-a-Chip (SoC), chip antenna, single crystal and five passive components. Careful design of the operating system created a low-power design to enable a long life with small batteries. The hardware included several sensors: temperature, radiant temperature, relative humidity, magnetometer, accelerometer, and light, with an optional occupancy (Passive InfraRed) sensor. The project was the basis of several applications, both internal to the research team and other researchers and professionals at other institutions. Several applications used the sensor hardware as the basis for other complex devices. Other applications used the sensors to improve building performance through interoperating with the building Heating Ventilation and Air-Conditioning (HVAC) system, such as using occupancy and/or distributed temperature sensing to reduce HVAC zone energy while still providing thermal comfort and to reduce peak loads in small commercial buildings. We demonstrated cloud-based energy analytics, implemented a schedule and a Model Predictive Controller in a small commercial building to optimize HVAC energy, occupancy and electricity price. Initial integration of these technological innovations was performed through the creation of execution containers containing the WAVE agent and various driver, proxy, or building system function logic. The research added to the understanding of efficient sensor hardware, secure middleware, time-series data management (high performance database), efficient communication protocols, and interoperating with applications and building systems. The project showed the technical effectiveness and economic feasibility of creating a low-cost, modular, and easy-to-deploy sensor. Through conversations with multiple end users, the research team discovered that many customers wanted data management and services in addition to the sensors. HamiltonIOT developed packages of sensors, border router, and data services to provide a seamless “plug-and-play” sensor deployment. Some customers were willing to pay for higher quality sensors (such as light); some customers wanted a robust enclosure (waterproof).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Interplay between Facets and Defects during the Dissociative and Molecular Adsorption of Water on Metal Oxide Surfaces

Both surface terminations and defects play a central role in determining how water interacts with metal oxides, thereby setting important properties of the interface that govern reactivity such as the type and distribution of hydroxyl groups. However, the interconnections between facets and defects remain poorly understood, limiting the usefulness of conventional notions such as that hydroxylation is controlled by metal cation exposure at the surface. Here, using hematite (α-Fe 2 O 3 ) as a model system, we show how oxygen vacancies overwhelm surface cation-dependent hydroxylation behavior. Synchrotron-based ambient-pressure X-ray photoelectron spectroscopy was used to monitor the adsorption of molecular water and its dissociation to form hydroxyl groups in situ on (001), (012), or (104) facet-engineered hematite nanoparticles. Supported by density functional theory calculations of the respective surface energies and oxygen vacancy formation energies, the findings show how oxygen vacancies are more prone to form on higher energy facets and induce surface hydroxylation at extremely low relative humidity values of 5 x10 - 5 %. Further, when these vacancies are eliminated, the extent of surface hydroxylation across the facets is as expected from the areal density of exposed iron cations at the surface. These findings help answer fundamental questions about the nature of reducible metal oxide-water interfaces in natural and technological settings and lay the groundwork for rational design of improved oxide-based catalysts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Laboratory Testing and Performance Characterization of the High Efficiency Dehumidification System (HEDS) Technology

The high efficiency dehumidification system (HEDS) is a unique air handling unit (AHU) design with two water coils. Connected in series, these water coils can sensibly reheat the airstream after it is cooled and dehumidified, thereby mitigating (or sometimes eliminating) the need for conventional sensible reheat with additional energy from hot water, electric resistance or steam coils. Another unique design feature is the size of the HEDS primary cooling coil. While typical AHU cooling coils have a 6-row geometry, the HED's cooling coil has a deeper 10-row geometry enabling discharge air dew point temperatures at or below 55 degrees F despite warmer chilled water supply temperatures approaching (sometimes exceeding) 50 degrees F. The ability to meet acceptable discharge air dew points with warmer chilled water supply temperatures improves both operational efficiency and system resilience against chilled water plant operational or control issues. This report summarizes the 59 steady-state test results that form a comprehensive performance map of the HEDS technology including its reheat capability. The breadth of outdoor air conditions and flow rates over which the HEDS technology was tested and characterized encompasses the unit 1) operating as a dedicated outdoor air system or mixed air system and 2) controlled with constant air volume or variable air volume fan control.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

An Integrated Deposition and Passivation Strategy for Controlled Crystallization of 2D/3D Halide Perovskite Films

Abstract This work introduces a simplified deposition procedure for multidimensional (2D/3D) perovskite thin films, integrating a phenethylammonium chloride (PEACl)‐treatment into the antisolvent step when forming the 3D perovskite. This simultaneous deposition and passivation strategy reduces the number of synthesis steps while simultaneously stabilizing the halide perovskite film and improving the photovoltaic performance of resulting solar cell devices to 20.8%. Using a combination of multimodal in situ and additional ex situ characterizations, it is demonstrated that the introduction of PEACl during the perovskite film formation slows down the crystal growth process, which leads to a larger average grain size and narrower grain size distribution, thus reducing carrier recombination at grain boundaries and improving the device's performance and stability. The data suggests that during annealing of the wet film, the PEACl diffuses to the surface of the film, forming hydrophobic (quasi‐)2D structures that protect the bulk of the perovskite film from humidity‐induced degradation.

2D/3D perovskites↗

Which Combinations of Environmental Conditions and Microphysical Parameter Values Produce a Given Orographic Precipitation Distribution?

This study applies an idealized modeling framework, alongside a Bayesian Markov chain Monte Carlo (MCMC) algorithm, to explore which combinations of upstream environmental conditions and cloud microphysical parameter values can produce a particular precipitation distribution over an idealized two-dimensional, bell-shaped mountain. Simulations focus on orographic precipitation produced when an atmospheric river interacts with topography. MCMC-based analysis reveals that different combinations of parameter values produce a similar precipitation distribution, with the most influential parameters being relative humidity (RH), horizontal wind speed (U), surface potential temperature (θ sfc ), and the snow fall speed coefficient (A s ). RH, U, and A s exhibit interdependence: changes in one or more of these factors can be mitigated by compensating changes in the other(s) to produce similar orographic precipitation rates. The results also indicate that the parameter sensitivities and relationships can vary for spatial subregions and given different environmental conditions. In particular, high θ sfc values are more likely to produce the target precipitation rate and spatial distribution, and thus the ensemble of simulations shows a preference for liquid precipitation at the surface. The results presented here highlight the complexity of orographic precipitation controls, and have implications for flood and water management, observational efforts, and climate change.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ultra-Low SWaP CO 2 Sensing for Demand Control Ventilation (Final Report)

In this project PARC and Energy ETC aimed to develop an ultra-low cost, size, weight, and power (SWaP) printed CO 2 sensor system for occupancy detection to enable Demand Control Ventilation (DCV) on a per-room basis. The CO 2 sensor technology is based on the temperature variation when CO 2 reversibly physisorbs to a highly conductive and high surface area sorbent surface, and is compatible with integration with PARC innovations in printed sensors and flexible electronics, for which PARC is a globally leading research center. The printed CO 2 sensor itself is designed to be compatible with PARC’s “peel-and-stick” platform of ultra-low power, low-cost, distributed sensors, and to facilitate real-time DCV based on overall indoor air quality (IAQ). Previously, PARC has developed flexible hybrid electronics (FHE) compatible materials to measure humidity, temperature, light, strain, and gases such as carbon monoxide, methane, ammonia, and hydrogen sulfide. Through this project, PARC developed FHE-compatible materials to measure CO 2 . Thus, with one <$15 FHE “peel-and-stick” based sensor node, a building management system (BMS) will be able to capture a complete picture of the indoor environment. This includes IAQ, light, temperature, and other comfort factors that impact building operations. Combined with optimized DCV, this low-cost sensor capability can be a key enabler of annual primary energy savings of ~ 0.3-0.4 Quad in commercial buildings while ensuring healthy IAQ. Energy ETC is a leader in supplier-agnostic BMS deployments and will design the commissioning and deployment procedures to maximize system interoperability.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Composite PEMs from Electrospun Crosslinkable Poly(Phenylene Sulfonic Acid)s (Final Technical Report)

The main objective of this project is to fabricate and demonstrate superior fuel cell performance of an electrospun composite all-hydrocarbon, non-PFSA membrane. The project builds on two earlier, DOE-funded studies demonstrating high proton conductivity, even at very low humidity of crosslinkable poly(phenylenesulfonic acid), cPPSA, solution cast films, and high durability of electrospun perfluorosulfonic acid (PFSA) composite membranes. Most project milestones were fully met but the best membrane conductivity and fuel cell performance were obtained with membranes that did not contain electrospun sulfonated polyphenylene, as initially planned. Instead, an excellent performance was achieved with membranes fabricated by pore-filling, either with electrospun poly(phenyl sulfone) scaffolds or with commercial, expanded polytetrafluoroethylene scaffolds. Fuel cell testing demonstrated performance better than that of Nafion 211 or Nafion XL, particularly at lower cell humidification levels with significantly lower hydrogen crossover. No accelerated stress testing was performed, due to the initial numerous difficulties with controlling the copolymerization reaction, which took excessive amount of time to overcome. Potential scale-up of the proposed composite membrane technology can aid in boosting the fuel cell power output and simplification of the cell hydration system.

08 HYDROGEN↗

Roll-to-Roll, Dual-Layer Slot Die Coating of Chitin and Cellulose Oxygen Barrier Films for Renewable Packaging

Cellulose and chitin are the two most abundant naturally produced biopolymers and are being extensively studied as candidates for renewable oxygen barrier films used in packaging. It has been shown that bilayers formed from cellulose nanocrystals (CNCs) and chitin nanofibers (ChNFs) exhibit oxygen barrier properties similar to polyethylene terephthalate (PET). However, this prior work explored only coating each layer individually in sequence through techniques such as spray coating. Here, we demonstrate the viability of dual-layer slot die coating of CNC/ChNF bilayers onto cellulose acetate (CA) substrates. The dual-layer slot die method enables significantly lower oxygen permeability versus spray coating while using a roll-to-roll system that applies the bilayer in a single pass. This work discusses suspension properties, wetting, and drying conditions required to achieve well-controlled ChNF/CNC bilayers. Spray-coated bilayer films were on average 25% thinner than the dual-layer bilayer film; however, the thickness-normalized oxygen permeability (OP) of the dual-layer-coated ChNF/CNC bilayer film on CA was 20 times better than that of the spray-coated bilayers. Additionally, it has been shown that ChNF contributes to the wetting and barrier properties. Values of OP for the slot die-coated bilayers under optimized drying conditions were as low as 1.2 cm 3 ∙μm∙m -2 ∙d -1 ∙kPa -1 , corresponding to a normalized oxygen transmission rate of 0.32 cm 3 ∙m -2 ∙d -1 at 23 °C and 50% relative humidity. It is also noted that the adhesive properties of the dual-layer coating are also improved when films are air-dried and that ChNF contributes to the wetting and barrier properties.

09 BIOMASS FUELS↗

Impact of Proton Activity on Fuel-Cell Performance (CRADA Final Report)

The key attribute that is being investigated is the dependence of the oxygen-reduction and hydrogen-oxidation reaction kinetics on proton activity. The influence of proton activity on the kinetics is also important in the determination of limiting factors that impact overall fuel-cell performance. At lower humidities, which are required to simplify fuel-cell water and thermal management (especially for higher-temperature operation) and enable next generation fuel cells, the ionomer water content will be different than that in today’s fuel cells. Such changes in water content directly impact the activity and concentration of protons. Thus, it is necessary to quantify this impact of proton activity on the reaction kinetics, and to determine means to mitigate any detrimental impacts to enable high performance. To realize the above goals of understanding the intrinsic interactions of proton activity on hydrogen-oxidation and oxygen-reduction kinetics, systematic investigations were carried out and a novel technique, a rapid microelectrode with environmental control, was realized. The experimental campaign at LBNL worked alongside that of TokyoTech and both were complemented by mathematical modeling of the key phenomena. The results demonstrated a robust method to analyze the kinetic behavior and an impact of proton activity, although greater delineation in terms of ion concentration versus activity was not obtained fully due in part to limited lab access during the COVID pandemic.

30 DIRECT ENERGY CONVERSION↗

Performance of Fire Danger Indices and Their Utility in Predicting Future Wildfire Danger Over the Conterminous United States

Abstract Predicting current and future wildfire frequency and size is central to wildfire control and management. Multiple fire danger indices (FDIs) that incorporate weather and fuel conditions have been developed and utilized to support wildfire predictions and risk assessment. However, the scale‐dependent performance of individual FDIs remains poorly understood, which leads to large uncertainty in the estimated fire sizes under climate change. Here, we calculate four commonly used FDIs over the conterminous United States using high‐resolution (4 km) climate and fuel data sets for the 1984–2019 period. The relationships of these four FDIs to the observed wildfire sizes show that higher values of FDIs correlate to larger total fire sizes; this correlation is more robust at larger spatial scales. Sensitivity analysis indicates that the daily minimum relative humidity and precipitation are the most important drivers of the annual mean fire danger. In the instances of extreme fire danger, wind speed becomes a critical factor and should be considered in the calculation of the FDI. To assess the impact of climate change on future fire size, we calculate the present‐day and end‐of‐century FDIs using the 12 km regional climate model simulations. The four FDIs generally predict consistent changes in future fire potential, suggesting an overall higher fire potential in conjunction with a prolonged wildfire season in future climate. Regionally, the four FDIs also reveal similar seasonal patterns as the enhancement arises mostly in spring and summer over the southwest US while in summer and fall over the northern and eastern US.

54 ENVIRONMENTAL SCIENCES↗

Submicrometer spectromicroscopy of UO 2 aged under high humidity conditions

We report the oxidation of uranium dioxide is a complicated process, depending on factors including humidity, temperature, and microstructure. To further determine the characteristics of this process, UO 2 particles were allowed to age and agglomerate under 98% relative humidity at room temperature for 378 days. A focused ion beam (FIB) section of this agglomeration was then measured at the O K-edge, U N 5 -edge, and C K-edge using the scanning transmission x-ray microscope (STXM) at the Advanced Light Source. O K-edge and U N 5 -edge x-ray absorption measurements allowed for the elemental and chemical species mapping of the agglomerates and indicated the formation of schoepite at the submicrometer scale in specific locations. Non-negative matrix factorization was employed to elucidate the main components at the O K-edge, which were uranyl (schoepite) formed primarily at the interface of the sample with controlled atmosphere, a UO 2 -like bulk component present in the majority of the sample, and an oxygen species present at the surface of the FIB section, which is likely adsorbed water. STXM spectromicroscopy measurements at the U N 5 -edge measurements also confirmed the location of oxidized uranium. This analysis is a valuable insight into the formation of schoepite on UO 2 and shows the sensitivity to and utility of STXM spectromicroscopy for uranium speciation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fluorine-Free Precise Polymer Electrolyte for Efficient Proton Transport: Experiments and Simulations

Designing polymers with controlled nanoscale morphologies and scalable synthesis is of great interest in the development of fluorine-free materials for proton-exchange membranes in fuel cells. This study focuses on a precision polyethylene with phenylsulfonic acid branches at every fifth carbon, p5PhSA, with a high ion-exchange capacity (4.2 mmol/g). The polymers self-assemble into hydrophilic and hydrophobic co-continuous nanoscale domains. In the hydrated state, the hydrophilic domain, composed of polar sulfonic acid moieties and water, serves as a pathway for efficient mesoscopic proton conductivity. The morphology and proton transport of p5PhSA are evaluated under hydrated conditions using in situ X-ray scattering and electrochemical impedance spectroscopy techniques. Additionally, at 40 °C and 95% relative humidity, the proton conductivity of p5PhSA is 0.28 S/cm, which is four times greater than Nafion 117 under the same conditions. Atomistic molecular dynamics (MD) simulations are also used to elucidate the interplay between the structure and the water dynamics. The MD simulations show strong nanophase separation between the percolated hydrophilic and hydrophobic domains over a wide range of water contents. The percolated hydrophilic nanoscale domain facilitates the rapid proton transport in p5PhSA and demonstrates the potential of precise hydrocarbon-based polymers as processible and effective proton-exchange membranes.

36 MATERIALS SCIENCE↗

The hygrothermal performance of continuous and cavity wood fiber insulation

Wood fiber insulation is an emerging material known for its effective thermal performance and moisture management properties, making it a compelling alternative to conventional insulation. Its vapor permeability and ability to regulate indoor humidity contribute to improved building durability and comfort, particularly in varying climate conditions. The goal of this project is to characterize the hygrothermal performance of a new wood fiber insulation product line in U.S. climate zones and to facilitate the design and construction of the product in residential and light commercial building envelopes. This study investigates the thermal and hygrothermal performance of wood fiber insulation, both as continuous and cavity insulation. The research employs an exhaustive simulation task and an environmental chamber test of a wood fiber insulation. Over 400 simulations were conducted to study the hygrothermal characteristics of bio-based wood fiber insulation in various building envelope configurations across four climate zones. Environmental chamber tests were conducted under controlled winter conditions representative of Climate Zone 5A (Chicago, IL) to complement the simulation results. The chamber tests focused on the hygrothermal performance of the wood fiber insulation and the sheathing board to assess the insulation's ability to manage moisture in a cold climate. Simulation and environmental chamber test results were analyzed to evaluate the insulation's consistency and efficacy across diverse climatic zones. Results show that with a proper moisture control strategy, both cavity and continuous wood fiber insulation can work properly in both new and retrofit constructions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Hygrothermal Performance of Continuous and Cavity Wood Fiber Insulation

Wood fiber insulation is an emerging material known for its effective thermal performance and moisture management properties, making it a compelling alternative to conventional insulation. Its vapor permeability and ability to regulate indoor humidity contribute to improved building durability and comfort, particularly in varying climate conditions. The goal of this project is to characterize the hygrothermal performance of a new wood fiber insulation product line in U.S. climate zones and to facilitate the design and construction of the product in residential and light commercial building envelopes. This study investigates the thermal and hygrothermal performance of wood fiber insulation, both as continuous and cavity insulation. The research employs an exhaustive simulation task and an environmental chamber test of a wood fiber insulation. Over 400 simulations were conducted to study the hygrothermal characteristics of bio-based wood fiber insulation in various building envelope configurations across four climate zones. Environmental chamber tests were conducted under controlled winter conditions representative of Climate Zone 5A (Chicago, IL) to complement the simulation results. The chamber tests focused on the hygrothermal performance of the wood fiber insulation and the sheathing board to assess the insulation's ability to manage moisture in a cold climate. Simulation and environmental chamber test results were analyzed to evaluate the insulation's consistency and efficacy across diverse climatic zones. Results show that with a proper moisture control strategy, both cavity and continuous wood fiber insulation can work properly in both new and retrofit constructions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗