Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “control algorithm”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Design and Performance Evaluation of a Resistive Control Using a Hydraulic PTO System for the TALOS Wave Energy Converter

This study is focused on developing a numerical model to evaluate the performance of a hydraulic PTO system for the TALOS Wave Energy Converter. The WEC device is described and the architecture of the hydraulic PTO system is presented with detail. The WEC is modeled using WEC-Sim, and the PTO is modeled using the Simscape Fluids library from Simulink. The hydraulic PTO is based on a constant pressure configuration that is suitable for WEC passive control. The hydraulic system is composed by a set of rectifying valves and two hydraulic accumulators that reduce the stiffness of the system and also serve as energy storage devices. One of the advantages of this hydraulic PTO architecture is the possibility of controlling the electric generator to operate around the optimal efficiency operating point. The main components of the hydraulic PTO are off-the-shelf devices that are commercially available, which will facility a future deployment of the designed system. The design variables used for this study are the accumulator size, the maximum pressure in the accumulators, the hydraulic motor maximum displacement, and the shaft speed in the electric generator. The performance of the system is evaluated individually, using sinusoidal inputs that replicates regular wave conditions. In addition to this, the numerical model of the PTO is coupled to a WEC-Sim simulation of the TALOS Wave Energy Converter with six PTOs to generate a wave-to-wire model. The main objective of this work is to present a comprehensive design methodology that could serve as a guideline for future research efforts focused on implementing control algorithms on multi degree of freedom WECs.

hydraulic systems↗

Composable optimization and control toolkit for scientific applications

Applications of Artificial Intelligence (AI) and Machine Learning (ML) can improve the computational efficiency and scientific research output. In order to improve interoperability and reuse of AI/ML software, a composable approach is required. This talk presents a composable approach for scientific workflow development that allows seamless integration of various modules developed by independent researchers. These practices will reduce redundant software development by allowing re-use of workflow modules across projects, teams, departments and facilities. We will present three use cases that follow the composable approach namely, Scientific Optimization and Control Toolkit (SOCT), SciDAC QuantOm workflow, and JLab Nuclear Physics experimental workflows. This talk will dive deeper into SOCT and present the details of the composable code development for optimization and control algorithms using reinforcement learning.

Rajput, Kishansingh↗

A safe reinforcement learning algorithm for supervisory control of power plants

Traditional control theory-based methods require tailored engineering for each system and constant fine-tuning. In power plant control, one often needs to obtain a precise representation of the system dynamics and carefully design the control scheme accordingly. Model-free Reinforcement learning (RL) has emerged as a promising solution for control tasks due to its ability to learn from trial-and-error interactions with the environment. It eliminates the need for explicitly modeling the environment’s dynamics, which is potentially inaccurate. However, the direct imposition of state constraints in power plant control raises challenges for standard RL methods. To address this, we propose a chance-constrained RL algorithm based on Proximal Policy Optimization for supervisory control. Our method employs Lagrangian relaxation to convert the constrained optimization problem into an unconstrained objective, where trainable Lagrange multipliers enforce the state constraints. In conclusion, our approach achieves the smallest distance of violation and violation rate in a load-follow maneuver for an advanced Nuclear Power Plant design.

constrained optimization↗

Data-Enabled Predictive Control for Building HVAC Systems

Model predictive control is widely used as a control technology for the computation of optimal control inputs of building heating, ventilating, and air conditioning (HVAC) systems. However, both the benefits and widespread adoption of model predictive control (MPC) are hindered by the effort of model creation, calibration, and accuracy of the predictions. In this paper, we apply the data-enabled predictive control (DeePC) algorithm for designing controls for building HVAC systems. The algorithm solely depends on input/output data from the system to predict future state trajectories without the need for system identification. The algorithm relies on the idea that a vector space of all input–output trajectories of a discrete-time linear time-invariant (LTI) system is spanned by time-shifts of a single measured trajectory, given the input signal is persistently exciting. Closed-loop simulations using EnergyPlus are performed to demonstrate the approach. The simulated building modeled in EnergyPlus is a modified commercial large office prototype building served by an air handling unit-variable air volume HVAC system. Temperature setpoints of zones are used as control variables to minimize the HVAC energy cost of the building considering a time-of-use electricity rate structure. Furthermore, sensitivity analysis is conducted to gain insights into the effect of parameter tuning on DeePC performance. Simulation results are used to illustrate the performance of the algorithm and compare the algorithm with model-based MPC and occupancy-based setpoint controller. Overall, DeePC achieves similar performance compared to MPC for lower engineering effort.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Implementation and test of an automated control hunting fault correction algorithm in a fault detection and diagnostics tool

Control hunting due to improper proportional–integral–derivative (PID) parameters in the building automation system (BAS) is one of the most common faults identified in commercial buildings. It can cause suboptimal performance and early failure of heating, ventilation, and air conditioning (HVAC) equipment. Commercial fault detection and diagnostics (FDD) software represents one of the fastest growing market segments in smart building technologies in the United States. Implementation of PID retuning procedures as an auto-correction algorithm and integration into FDD software has the potential to mitigate control hunting across a heterogeneous portfolio of buildings with different BAS in a scalable way. This paper presents the development, implementation, and field testing of an automated control hunting fault correction algorithm based on lambda tuning open-loop rules. The algorithm was developed in a commercial FDD software and successfully tested among nine variable air volume boxes in an office building in the United States. The paper shows the feasibility of using FDD tools to automatically correct control hunting faults, discusses scalability considerations, and proposes a path forward for the HVAC industry and academia to further improve this technology.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Stochastic Model Predictive Control With Gaussian Wind Direction Preview for Wake Steering

This article addresses the problem of wake steering control for wind farms that explicitly consider the tradeoff between farm-level power generation and yaw duty cycle under variable and uncertain wind conditions. A novel stochastic model predictive control (MPC) algorithm is presented, which utilizes a stochastic model of the freestream wind field components in a receding horizon framework to compute optimal yaw set points that maximize the expected value of the farm power while constraining the yaw actuation. Different configurations of the algorithm are evaluated using a steady-state wind farm simulator. The proposed stochastic MPC algorithm can plan control actions over a future prediction horizon based on probabilistic estimates of the incoming wind magnitude and direction.

17 WIND ENERGY↗

Optimization-Based Fast-Frequency Estimation and Control of Low-Inertia Microgrids

The lack of inertial response from non-synchronous, inverter-based generation in microgrids makes the power system vulnerable to a large rate of change of frequency (ROCOF) and frequency excursions. Energy storage systems (ESSs) can be utilized to provide fast-frequency support to prevent such large excursions in the system. However, fast-frequency support is a power-intensive application that has a significant impact on the ESS lifetime. In this paper, a framework that allows the ESS operator to provide fast-frequency support as a service is proposed. The framework maintains the desired quality-of-service (limiting the ROCOF and frequency) while taking into account the ESS lifetime and physical limits. The framework utilizes moving horizon estimation (MHE) to estimate the frequency deviation and ROCOF from noisy phase-locked loop (PLL) measurements. These estimates are employed by a model predictive control (MPC) algorithm that computes control actions by solving a finite-horizon, online optimization problem. Additionally, this approach avoids oscillatory behavior induced by delays that are common when using low-pass filters as with traditional derivative-based (virtual inertia) controllers. MATLAB/Simulink simulations on a test system from Cordova, Alaska, show the effectiveness of the MHE-MPC approach to reduce frequency deviations and ROCOF of a low-inertia microgrid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Software Control Program For Transportable Microgrid State-of-charge Balancing And Frequency Stability Controls

A deterministic state-of-charge (SOC) balancing approach software control code is introduced as an integral secondary management to primary control layer of an islanded small microgrid or nanogrid system made up of multiple grid-forming inverter/battery/solar combination systems, where each set of batteries with each inverter are on independent DC buses (i.e. non-paralleled on the DC sides). A DERMS-level control approach, algorithm and automation controller program was developed to improve coordination and enable microgrid asset compliance and SOC balancing, enabling provision of a system-level power stability support architecture, load support, and asset scalability. The architecture is configured to treat each unit or micro/nano-grid as a node in a microgrid network, allowing for autonomous DERMS control regarding load and SOC balancing and power stability. As the network grows with the addition of units, greater coordination efforts may be required. The ideal small network microgrid ranges from 2-10 inverter/battery units before additional control parameters must be considered in the existing architecture. The control approach focuses on a deterministic state-of-charge analysis as the primary level control process followed by a secondary control loop using a forced frequency-watt droop strategy to conform off-the-shelf components into behaving under a leader-follower configuration. Adopting this control scheme has been shown to allow for a balanced, unit-coordinated microgrid network, enabling stable power flow. The deterministic state-of-charge approach is introduced as an integral primary control layer of an islanded small network microgrid. A standard strategy for SOC balancing is implementing a battery management system (BMS) to control SOC on the DC side. An alternative approach is to determine how to coordinate sending and receiving power on the AC side with multiple units. The latter approach assesses all the integrated units in the microgrid network. Once the individual units are identified, further system data is required to calculate each unit's total kWh, provided information about its capability to supply or consume kWh and availability. The secondary control layer in the multi-layered small network microgrid methodology uses the primary layer’s decision to initiate frequency setpoint changes, initializing the SOC balancing. The secondary control layer considers numerous system-dependent variables to enable a charging and discharging profile based on adjustable frequency setpoints. The combined architecture will result in stable, coordinated power flow enhancing an AC microgrid's functionalities.

Myers, KurtS [Idaho National Laboratory (INL), Ida↗

Low-latency quantum control using AI algorithms on cryogenic microelectronics platforms

Superconducting quantum computers are a particular technology that involve the realization of qubits by means of LC circuits with a Josephson junction. As shown in Fig. 1, this latter addition has the effect of introducing a nonlinearity (anharmonicity) that makes the frequency spacing between each energy level non-uniform. This is a desired effect for separating the two lowest levels, used for computation, from the higher ones, that are theoretically infinite and which are not desired to be used.

97 MATHEMATICS AND COMPUTING↗

Comparative Analysis of ANN and LSTM Prediction Accuracy and Cooling Energy Savings through AHU-DAT Control in an Office Building

This paper proposes the optimal algorithm for controlling the HVAC system in the target building. Previous studies have analyzed pre-selected algorithms without considering the unique data characteristics of the target building, such as location, climate conditions, and HVAC system type. To address this, we compare the accuracy of cooling load prediction using ANN and LSTM algorithms, widely used in building energy research, to determine the optimal algorithm for HVAC control in the target building. We develop a simulation model calibrated with actual data to ensure data reliability and compare the energy consumption of the existing HVAC control method and the two algorithms-based methods. Results show that the ANN algorithm, with a CV(RMSE) of 12.7%, has a higher prediction accuracy than the LSTM algorithm, CV(RMSE) of 17.3%, making it a more suitable algorithm for HVAC control. Furthermore, implementing the ANN-based approach results in a 3.2% cooling energy reduction from the optimal control of Air Handling Unit (AHU) Discharge Air Temperature (DAT) compared to the fixed DAT at 12.8 °C in a representative day. This study demonstrates that ML-based HVAC system control can effectively reduce cooling energy consumption in HVAC systems, providing an effective strategy for energy conservation and improved HVAC system efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Model Based Predictive Control for Frequency Support in Multi-port Autonomous Reconfigurable Solar Plants

Primary frequency support functionality can be an added advantage for any new grid integrated power electronics resource. With increased penetration of power electronics resources, inertial and primary frequency response capabilities are decreasing. In this research paper, an advanced model-based predictive control (MBPC) algorithm for providing frequency support to a new topology of integrated photovoltaic(PV), batterybased energy storage systems (ESS), and high-voltage direct current (HV dc) systems called multi-port autonomus reconfigurable solar (MARS) plants is based on the synchronverter-based control. The simulation of MARS-HV dc system with proposed control strategy is simulated and validated for MARS connected to low short circuit ratio (SCR) grids in PSCAD/EMTDC simulation environment. The control algorithm proposed showcases better performance in terms of frequency nadir improvement and frequency steady state improvemnt with respect to no frequency control.

Marthi, Phani Ratna Vanamali↗